Engineering PapersSearch

SEARCH · Engineering Papers

Results for “linear accelerator,”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Energy recovery proton linear accelerator

High-power proton linear accelerators have important applications in both scientific research and industry. However, the operation of such accelerators with megawatt-level beam power is expensive and limits the broad availability of these facilities. In this Letter, we propose a novel energy recovery proton linear accelerator in which the final GeV-level proton beam is reinjected into the linear accelerator from the accelerator exit and is decelerated in the same accelerator down to about 2 MeV, close to the initial beam energy. This substantially reduces the power consumption of the proton linear accelerator and also avoids the need for a high-power beam dump. We demonstrate this concept through self-consistent simulations and show that the beam-beam effect between the forward-accelerating beam and the backward-decelerating beam would not be a limiting factor for the proposed concept. A potential application of this concept to an electron-ion collider based on energy recovery electron and ion accelerators is discussed.

Energy recovery linacs

Operations and maintenance manual for the linear accelerator (sled)

The Linear Accelerator, a sliding chair which is pulled along a stationary platform in a horizontal axis is described. The driving force is a motor controlled by a velocity loop amplifier, and the mechanical link to the chair is a steel cable. The chair is moved in forward and reverse directions as indicated by the direction of motor rotation. The system operation is described with emphasis on the electronic control and monitoring functions. Line-by-line schematics and wire lists are included.

Source record

Small scale electron linear accelerators for industrial applications

Linear accelerators (linacs), producing electron or X-ray radiation in the MeV range, are critical tools for industrial irradiation, medical device sterilization, food pasteurization, non-destructive testing, security, medical, and many other applications. Many of these applications require compact and flexible radiation sources. In this paper, we present new technologies for small-scale electron linear accelerators and examples of their practical implementations. Furthermore, these developments include low energy accelerators with self-shielding options and form factors, ranging from cabinet-size to hand-portable generators; medium-energy accelerators for novel radiotherapy and security applications; and high-energy 10 MeV linacs capable of reaching 20–35 kW beam power for emerging industrial and phytosanitary applications

43 PARTICLE ACCELERATORS

Response properties of pigeon otolith afferents to linear acceleration

In the present study, the sensitivity to sinusoidal linear accelerations in the plane of the utricular macula was tested in afferents. The head orientation relative to the translation axis was varied in order to determine the head position that elicited the maximal and minimal responses for each afferent. The response gain and phase values obtained to 0.5-Hz and 2-Hz linear acceleration stimuli were then plotted as a function of head orientation and a modified cosine function was fit to the data. From the best-fit cosine function, the predicted head orientations that would produce the maximal and minimal response gains were estimated. The estimated maximum response gains to linear acceleration in the utricular plane for the afferents varied between 75 and 1420 spikes s-1 g-1. The mean maximal gains for all afferents to 0.5-Hz and 2-Hz sinusoidal linear acceleration stimuli were 282 and 367 spikes s-1 g-1, respectively. The minimal response gains were essentially zero for most units. The response phases always led linear acceleration and remained constant for each afferent, regardless of head orientation. These response characteristics indicate that otolith afferents are cosine tuned and behave as one-dimensional linear accelerometers. The directions of maximal sensitivity to linear acceleration for the afferents varied throughout the plane of the utricle; however, most vectors were directed out of the opposite ear near the interaural axis. The response dynamics of the afferents were tested using stimulus frequencies ranging between 0.25 Hz and 10 Hz (0.1 g peak acceleration). Across stimulus frequencies, most afferents had increasing gains and constant phase values. These dynamic properties for individual afferents were fit with a simple transfer function that included three parameters: a mechanical time constant, a gain constant, and a fractional order distributed adaptation operator.

Non-NASA Center

Vestibular short latency responses to pulsed linear acceleration in unanesthetized animals

Linear acceleration transients were used to elicit vestibular compound action potentials in non-invasively prepared, unanesthetized animals for the first time (chicks, Gallus domesticus, n = 33). Responses were composed of a series of up to 8 dominant peaks occurring within 8 msec of the stimulus. Response amplitudes for 1.0 g stimulus ranged from 1 to 10 microV. A late, slow, triphasic, anesthesia-labile component was identified as a dominant response feature in unanesthetized animals. Amplitudes increased and latencies decreased as stimulus intensity was increased (MANOVA P less than 0.05). Linear regression slope ranges were: amplitudes = 1.0-5.0 microV/g; latencies = -300 to -1100 microseconds/g. Thresholds for single polarity stimuli (0.035 +/- 0.022 g, n = 11) were significantly lower than those of alternating polarity (0.074 +/- 0.028 g, n = 18, P less than 0.001). Bilateral labyrinthectomy eliminated responses whereas bilateral extirpation of cochleae did not significantly change response thresholds. Intense acoustic masking (100/104 dB SL) produced no effect in 2 animals, but did produce small to moderate effects on response amplitudes in 7 others. Changes were attributed to effects on vestibular end organs. Results of unilateral labyrinth blockade (tetrodotoxin) suggest that P1 and N1 preferentially reflect ipsilateral eighth nerve compound action potentials whereas components beyond approximately 2 msec reflect activity from vestibular neurons that depend on both labyrinths. The results demonstrate that short latency vestibular compound action potentials can be measured in unanesthetized, non-invasively prepared animals.

NASA Discipline Neuroscience

A temporary threshold shift for self-motion detection following sustained, oscillating linear acceleration

Thresholds for detecting linear motion (self-motion) increased following exposure of human observers to sustained linear oscillation (fatiguing stimulus) at 0.26 Hz and approximately 0.5 G peak-to-peak for durations up to 30 min. Recovery to preexposure levels took place over a period of 10 to 15 min following the sustained oscillation termination. Differences in threshold shift magnitudes following sustained oscillation in various orientations support the interpretation that the observed threshold shifts resulted from fatigue of the utricular otolith receptors. Threshold shifts were not obtained following exposure of the human observers to sustained, unidirectional linear acceleration (2G) for durations up to 10 min with a centrifuge. The results of this study suggest a previously unobserved response property of the otolith organs, namely, that these organs can be fatigued in a manner analogous to other receptor systems.

Parker, D. E.

The Role of Linear Acceleration in Visual-Vestibular Interactions and Implications in Aircraft Operations

While considerable attention has been given to visual-vestibular interaction (VVI) during angular motion of the head as might occur during an aircraft spin, much less attention has been given to VVI during linear motion of the head. Such interaction might occur, for example, while viewing a stationary or moving display during vertical take-off and landing operations Research into linear VVI, particularly during prolonged periods of linear acceleration, has been hampered by the unavailability of a programmable translator capable of large excursions We collaborated with Otis Elevator Co. and used their research tower and elevator, whose motion could be digitally programmed, to vertically translate human subjects over a distance of 92.3 meters with a peak linear acceleration of 2 meters/sec(exp 2) During pulsatile or sinusoidal translation, the subjects viewed moving stripes (optokinetic stimulus) or a fixed point source (light emitting diode, led, display), respectively and it was generally found that. The direction of linear acceleration relative to the cardinal head axes and the direction of the slow component of optokinetic nystagmus (OKN) determined the extent of VVI during concomitant stripe motion and linear acceleration. Acceleration along the z head axis (A(sub z)) produced the largest VVI, particularly when the slow component of OKN was in the same direction as eye movements produced by the linear acceleration and Eye movements produced by linear acceleration are suppressed by viewing a fixed target at frequencies below 10 Hz But, above this frequency the suppression produced by VVI is removed. Finally, as demonstrated in non-human primates, vergence of the eyes appears to modulate the vertical eye movement response to linear acceleration in humans.

Correia, Manning J.

Two-dimensional spatiotemporal coding of linear acceleration in vestibular nuclei neurons

Response properties of vertical (VC) and horizontal (HC) canal/otolith-convergent vestibular nuclei neurons were studied in decerebrate rats during stimulation with sinusoidal linear accelerations (0.2-1.4 Hz) along different directions in the head horizontal plane. A novel characteristic of the majority of tested neurons was the nonzero response often elicited during stimulation along the "null" direction (i.e., the direction perpendicular to the maximum sensitivity vector, Smax). The tuning ratio (Smin gain/Smax gain), a measure of the two-dimensional spatial sensitivity, depended on stimulus frequency. For most vestibular nuclei neurons, the tuning ratio was small at the lowest stimulus frequencies and progressively increased with frequency. Specifically, HC neurons were characterized by a flat Smax gain and an approximately 10-fold increase of Smin gain per frequency decade. Thus, these neurons encode linear acceleration when stimulated along their maximum sensitivity direction, and the rate of change of linear acceleration (jerk) when stimulated along their minimum sensitivity direction. While the Smax vectors were distributed throughout the horizontal plane, the Smin vectors were concentrated mainly ipsilaterally with respect to head acceleration and clustered around the naso-occipital head axis. The properties of VC neurons were distinctly different from those of HC cells. The majority of VC cells showed decreasing Smax gains and small, relatively flat, Smin gains as a function of frequency. The Smax vectors were distributed ipsilaterally relative to the induced (apparent) head tilt. In type I anterior or posterior VC neurons, Smax vectors were clustered around the projection of the respective ipsilateral canal plane onto the horizontal head plane. These distinct spatial and temporal properties of HC and VC neurons during linear acceleration are compatible with the spatiotemporal organization of the horizontal and the vertical/torsional ocular responses, respectively, elicited in the rat during linear translation in the horizontal head plane. In addition, the data suggest a spatially and temporally specific and selective otolith/canal convergence. We propose that the central otolith system is organized in canal coordinates such that there is a close alignment between the plane of angular acceleration (canal) sensitivity and the plane of linear acceleration (otolith) sensitivity in otolith/canal-convergent vestibular nuclei neurons.

NASA Discipline Neuroscience

Spatiotemporal processing of linear acceleration: primary afferent and central vestibular neuron responses

Spatiotemporal convergence and two-dimensional (2-D) neural tuning have been proposed as a major neural mechanism in the signal processing of linear acceleration. To examine this hypothesis, we studied the firing properties of primary otolith afferents and central otolith neurons that respond exclusively to horizontal linear accelerations of the head (0.16-10 Hz) in alert rhesus monkeys. Unlike primary afferents, the majority of central otolith neurons exhibited 2-D spatial tuning to linear acceleration. As a result, central otolith dynamics vary as a function of movement direction. During movement along the maximum sensitivity direction, the dynamics of all central otolith neurons differed significantly from those observed for the primary afferent population. Specifically at low frequencies (</=0.5 Hz), the firing rate of the majority of central otolith neurons peaked in phase with linear velocity, in contrast to primary afferents that peaked in phase with linear acceleration. At least three different groups of central response dynamics were described according to the properties observed for motion along the maximum sensitivity direction. "High-pass" neurons exhibited increasing gains and phase values as a function of frequency. "Flat" neurons were characterized by relatively flat gains and constant phase lags (approximately 20-55 degrees ). A few neurons ("low-pass") were characterized by decreasing gain and phase as a function of frequency. The response dynamics of central otolith neurons suggest that the approximately 90 degrees phase lags observed at low frequencies are not the result of a neural integration but rather the effect of nonminimum phase behavior, which could arise at least partly through spatiotemporal convergence. Neither afferent nor central otolith neurons discriminated between gravitational and inertial components of linear acceleration. Thus response sensitivity was indistinguishable during 0.5-Hz pitch oscillations and fore-aft movements. The fact that otolith-only central neurons with "high-pass" filter properties exhibit semicircular canal-like dynamics during head tilts might have important consequences for the conclusions of previous studies of sensory convergence and sensorimotor transformations in central vestibular neurons.

NASA Discipline Neuroscience

Perception of tilt (somatogravic illusion) in response to sustained linear acceleration during space flight

During the 1998 Neurolab mission (STS-90), four astronauts were exposed to interaural and head vertical (dorsoventral) linear accelerations of 0.5 g and 1 g during constant velocity rotation on a centrifuge, both on Earth and during orbital space flight. Subjects were oriented either left-ear-out or right-ear-out (Gy centrifugation), or lay supine along the centrifuge arm with their head off-axis (Gz centrifugation). Pre-flight centrifugation, producing linear accelerations of 0.5 g and 1 g along the Gy (interaural) axis, induced illusions of roll-tilt of 20 degrees and 34 degrees for gravito-inertial acceleration (GIA) vector tilts of 27 degrees and 45 degrees , respectively. Pre-flight 0.5 g and 1 g Gz (head dorsoventral) centrifugation generated perceptions of backward pitch of 5 degrees and 15 degrees , respectively. In the absence of gravity during space flight, the same centrifugation generated a GIA that was equivalent to the centripetal acceleration and aligned with the Gy or Gz axes. Perception of tilt was underestimated relative to this new GIA orientation during early in-flight Gy centrifugation, but was close to the GIA after 16 days in orbit, when subjects reported that they felt as if they were 'lying on side'. During the course of the mission, inflight roll-tilt perception during Gy centrifugation increased from 45 degrees to 83 degrees at 1 g and from 42 degrees to 48 degrees at 0.5 g. Subjects felt 'upside-down' during in-flight Gz centrifugation from the first in-flight test session, which reflected the new GIA orientation along the head dorsoventral axis. The different levels of in-flight tilt perception during 0.5 g and 1 g Gy centrifugation suggests that other non-vestibular inputs, including an internal estimate of the body vertical and somatic sensation, were utilized in generating tilt perception. Interpretation of data by a weighted sum of body vertical and somatic vectors, with an estimate of the GIA from the otoliths, suggests that perception weights the sense of the body vertical more heavily early in-flight, that this weighting falls during adaptation to microgravity, and that the decreased reliance on the body vertical persists early post-flight, generating an exaggerated sense of tilt. Since graviceptors respond to linear acceleration and not to head tilt in orbit, it has been proposed that adaptation to weightlessness entails reinterpretation of otolith activity, causing tilt to be perceived as translation. Since linear acceleration during in-flight centrifugation was always perceived as tilt, not translation, the findings do not support this hypothesis.

STS-90 Shuttle Project

Encoding of head acceleration in vestibular neurons. I. Spatiotemporal response properties to linear acceleration

1. Extracellular recordings were made in and around the medial vestibular nuclei in decerebrated rats. Neurons were functionally identified according to their semicircular canal input on the basis of their responses to angular head rotations around the yaw, pitch, and roll head axes. Those cells responding to angular acceleration were classified as either horizontal semicircular canal-related (HC) or vertical semicircular canal-related (VC) neurons. The HC neurons were further characterized as either type I or type II, depending on the direction of rotation producing excitation. Cells that lacked a response to angular head acceleration, but exhibited sensitivity to a change in head position, were classified as purely otolith organ-related (OTO) neurons. All vestibular neurons were then tested for their response to sinusoidal linear translation in the horizontal head plane. 2. Convergence of macular and canal inputs onto central vestibular nuclei neurons occurred in 73% of the type I HC, 79% of the type II HC, and 86% of the VC neurons. Out of the 223 neurons identified as receiving macular input, 94 neurons were further studied, and their spatiotemporal response properties to sinusoidal stimulation with pure linear acceleration were quantified. Data were obtained from 33 type I HC, 22 type II HC, 22 VC, and 17 OTO neurons. 3. For each neuron the angle of the translational stimulus vector was varied by 15, 30, or 45 degrees increments in the horizontal head plane. In all tested neurons, a direction of maximum sensitivity was identified. An interesting difference among neurons was their response to translation along the direction perpendicular to that that produced the maximum response ("null" direction). For the majority of neurons tested, it was possible to evoke a nonzero response during stimulation along the null direction always had response phases that varied as a function of stimulus direction. 4. These spatiotemporal response properties were quantified in two independent ways. First, the data were evaluated on the basis of the traditional one-dimensional principle governed by the "cosine gain rule" and constant response phase at different stimulus orientations. Second, the response gain and phase values that were empirically determined for each orientation of the applied linear stimulus vector were fitted on the basis of a newly developed formalism that treats neuronal responses as exhibiting two-dimensional spatial sensitivity. Thus two response vectors were determined for each neuron on the basis of its response gain and phase at different stimulus directions in the horizontal head plane.(ABSTRACT TRUNCATED AT 400 WORDS).

NASA Discipline Neuroscience

A Novel Approach for Computing Rigid Body Motion Using Linear Accelerations

Here, a novel approach is presented for computing general rigid body motion based on a few known linear accelerations. This method utilizes linear acceleration data obtained from three distinct points on the body, all within a body-fixed reference frame. The only requirement is that the three chosen points must not be collinear. A system of differential-algebraic equations is derived, combining principles of rigid body kinematics with theory of the rotation group SO(3). These equations provide a framework for numerically computing various motion parameters, including angular velocity, angular acceleration, body orientation, velocity field, acceleration field, and displacement field. By numerically solving this system of equations, we can fully characterize rigid body motion in three-dimensional space. A numerical example is provided to demonstrate the practical implementation and efficacy of the proposed technique, illustrating its potential for accurate motion computation in various applications.

42 ENGINEERING