Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “legal dose of record”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

Intern Sized Poster for Dosimetry Research

Federal regulations mandate that personal dosimetry devices — like optically stimulated luminescence (OSLs) — must be worn by all US Department of Energy (DOE) and associated radiation workers to track their occupational dose. Unfortunately, the inadvertent passage of OSLs through x-ray security scanners can compromise their validity. With the advent of high energy, advanced resolution security technology used in airports, this once insignificant issue now requires that Radiological Control (RadCon) be able to accurately discern non-occupational dose to effected OSLs. This presentation will discuss the principles, methods, and, rather surprising, models for establishing the corrective dose estimates at the Idaho National Laboratory (INL), and its implication across the DOE.

61 RADIATION PROTECTION AND DOSIMETRY↗

Intern Sized Poster for Dosimetry Research

Federal regulations mandate that personal dosimetry devices — like optically stimulated luminescence (OSLs) — must be worn by all US Department of Energy (DOE) and associated radiation workers to track their occupational dose. Unfortunately, the inadvertent passage of OSLs through x-ray security scanners can compromise their validity. With the advent of high energy, advanced resolution security technology used in airports, this once insignificant issue now requires that Radiological Control (RadCon) be able to accurately discern non-occupational dose to effected OSLs. This presentation will discuss the principles, methods, and, rather surprising, models for establishing the corrective dose estimates at the Idaho National Laboratory (INL), and its implication across the DOE.

61 RADIATION PROTECTION AND DOSIMETRY↗

X-ray Security Imaging on Personal Dosimetry

Federal regulations mandate that personal dosimetry devices — like optically stimulated luminescence (OSLs) — must be worn by all US Department of Energy (DOE) and associated radiation workers to track their occupational dose. Unfortunately, the inadvertent passage of OSLs through x-ray security scanners can compromise their validity. With the advent of high energy, advanced resolution security technology used in airports, this once insignificant issue now requires that Radiological Control (RadCon) be able to accurately discern non-occupational dose to effected OSLs. This presentation will discuss the principles, methods, and, rather surprising, models for establishing the corrective dose estimates at the Idaho National Laboratory (INL), and its implication across the DOE.

61 RADIATION PROTECTION AND DOSIMETRY↗

Impairment of Human Ocular Tracking with Low-Dose Alcohol

Previous studies have documented adverse effects of alcohol on oculomotor performance. For example, moderate-dose alcohol (yielding a Blood Alcohol Concentration or BAC of 0.04-0.1%) has been shown to decrease steady-state pursuit gain (Fransson et al., 2010, Clin Neurophysiol, 121(12): 2134; Moser et al., 1998, J Neurol, 245(8): 542; Roche & King, 2010, Psychopharmacology, 212(1): 33), to increase saccade latency (Moser et al., 1998, J Neurol, 245(8): 542; Roche & King, 2010, Psychopharmacology, 212(1): 33), to decrease peak saccadic velocity (Fransson et al., 2010, Clin Neurophysiol, 121(12): 2134; Roche & King, 2010, Psychopharmacology, 212(1): 33), and to increase the frequency of catch-up saccades (Moser et al., 1998, J Neurol, 245(8): 542). Here, we administered two doses of ethanol on different days, yielding moderate (0.06%) and low (0.02%) levels of initial BAC, to examine the effects on human ocular tracking over BACs ranging from 0.00 to 0.07%. Twelve subjects (8 females) participated in a 5-day study. Three days of at-home measurements of daily activity and sleep were monitored, followed by two laboratory days where, ~5 hours after awakening, we administered one of the two possible single doses of alcohol. Using a previously published paradigm (Liston & Stone, 2014, J Vis, 14(14): 12), we measured oculomotor performance multiple times throughout the day with three pre-dosing baseline runs and bi-hourly post-dosing test runs until the subject recorded a BAC of 0.00% for two hours. BAC was measured before each run using an Alco-Sensor IV breathalyzer (Intoximeters, Inc., St. Louis, MO). For each of the oculometric measures, for each subject, we computed the within-subject % deviation for each test run from their baseline averaged across their three pre-dosing runs. We then averaged the data across subjects in 0.01% BAC bins. Finally, we used linear regression to compute the slope and x-intercept (threshold) of the mean binned % deviation as a function of BAC. We found that pursuit initiation was impaired at very low BAC levels, with significant (p < 0.002) linear trends in latency (+1.3%/0.01%BAC) and initial acceleration (-4.6%/0.01%BAC) with extrapolated absolute thresholds at or below 0.01% BAC. We also found that steady-state tracking was impaired showing significant (p < 0.002) linear trends in gain (- 3.8%/0.01%BAC) and catch-up saccade amplitude (+9.1%/0.01%BAC), again with extrapolated absolute thresholds around 0.01% BAC. We also found a significant (p < 0.02) increase in pursuit direction noise (+9.8%/0.01%BAC) with an extrapolated absolute threshold below 0.01% BAC. Many aspects of ocular tracking are impaired in a dose-dependent manner beginning at a BAC level around 0.01%, with significant effects at levels lower than previously reported and up to 8-times lower than the legal limit for driving in most states.

human performance↗