Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “leakage rate”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Effect of vadose zone on the steady-state leakage rates from landfill barrier systems

Leakage rates are evaluated for a landfill barrier system having a compacted clay liner (CCL) underlain by a vadose zone of variable thickness. A numerical unsaturated flow model SEEP/W is used to simulate the moisture flow regime and steady-state leakage rates for the cases of unsaturated zones with different soil types and thicknesses. The results of the simulations demonstrate that harmonic mean hydraulic conductivity of coarse textured vadose zones is 3-4 orders of magnitude less than saturated hydraulic conductivity; whereas, the difference is only one order of magnitude for fine textured vadose zones. For both coarse and fine textured vadose zones, the effective hydraulic conductivity of the barrier system and the leakage rate to an underlying aquifer increases with increasing thickness of the vadose zone and ultimately reaches an asymptotic value for a coarse textured vadose zone thickness of about 10 m and a fine textured vadose zone thickness of about 5 m. Therefore, the fine and coarse textured vadose zones thicker than about 5 m and 10 m, respectively, act as an effective part of the barrier systems examined. Although the thickness of vadose zone affects the effective hydraulic conductivity of the overall barrier system, the results demonstrated that the hydraulic conductivity of the CCL is the dominant factor controlling the steady-state leakage rates through barrier systems having single low permeability clay layers.

42 ENGINEERING↗

3-60B Type-B shipping cask enhanced operational features to facilitate leakage rate testing - 15585

EnergySolutions is fabricating a new 3-60B Type B Shipping Cask that will be ready for use in spring 2015, designed for shipping Type B quantities of activated and/or non-fuel-bearing reactor or accelerator components. EnergySolutions, in consult with Leak Testing Specialists, Inc., has implemented an improved design of the 3-60B cask closures to better facilitate periodic and maintenance leakage rate testing and to allow end users to more easily perform pre-shipment leakage rate testing to confirm proper assembly of the cask closures. A typical Type B cask closure lid design incorporates a double O-ring configuration, where the inner O-ring provides containment and the outer O-ring is used for leakage rate testing of the containment O-ring seal. Leakage rate testing of a double O-ring configuration is typically accomplished by filling the cask cavity with helium, pulling a vacuum on the annular space between the two O-rings and monitoring for helium leakage through the containment O-ring. One issue is the potential for helium saturation of the O-ring elastomeric material, which can result in leakage rate test failures. The cask cavity volume is typically large, and takes a significant amount of time to fill with helium. As a result, the saturation time for certain elastomeric compounds may be exceeded, leading to potential false-negative leakage rate testing results. To avoid this, that the cask cavity typically is loaded with sealed container(s) to reduce the free volume and the fill time. The improved 3-60B cask closure lid incorporates a triple O-ring seal configuration that facilitates maintenance leak rate testing of the closure lid containment O-ring seal and eliminates the issues discussed above. The triple O-ring configuration uses the middle O-ring as the containment seal, with the inner and outer test O-rings creating relatively small annular volumes for testing purposes. These small annular volumes are quick to fill, minimizing the issue of Helium saturation of the O-ring material. This seal configuration also makes it possible to detect and replace a damaged O-ring seal during loading operations, or dress a damaged sealing surface, and perform the required maintenance leakage rate testing of the replacement O-ring at the plant site without the need to unload the cask and send it to a maintenance facility. Also, a second test port has been added to each O-ring annulus to allow leakage rate testing to be accomplished using a formal system calibration that complies with the requirements and recommendations of ASME Section V, Article 10 [4], ANSI N14.5-97 [2], and ANSI N14.5-2014 [3]. This provides a simple, reliable, and accurate means to perform leakage rate testing with a test confidence level that cannot be achieved without the second test port. The improved closure and test port design simplifies and shortens the time required to perform leakage testing, resulting in reduced operating costs, greater schedule security, and dose savings for the cask users. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Leakage Rate Testing Considerations and Implementation of ANSI N 14.5-2014 Standard within EnergySolutions Type (B) cask fleet - 18629

In March 2016, Nuclear Regulatory Commission (NRC) staff issued Information Notice 2016-04: 'ANSI N14.5-2014 Revision and leakage rate testing considerations'. American National Standards Institute (ANSI) N14.5, 'American National Standard for Radioactive Materials-Leakage Tests on Packages for Shipment', applies to leakage rate testing of Low Level Radioactive Waste (LLRW) Type B packages operated under 10CFR71. In their information notice NRC is encouraging Type B cask license holders and licensees (cask users) to adapt a new version of ANSI N 14.5 standard. Typically, leakage rate testing for Type B packages (or casks) is performed at different stages of cask development (design and fabrication leak tests) and operations (periodic/maintenance and pre-shipment leak tests) with the purpose to reasonably assure that the packaging will contain radioactive material under both normal and hypothetical accident conditions of transport described in 10CFR71. The standard was updated to provide a modern, robust and standardized approach for performance of leak rate testing on Type B casks by the industry stakeholders. Although implementation of new version of the leak testing standard may not be problematic for a modern Type B package designs, it may be extremely challenging to apply its principles to the existing legacy Type B casks which were designed/fabricated more then 20-30 years ago based on older requirements. Majority of such casks are not 'leak test' friendly. Some of legacy Type B packages may not readily available to meet newer ANSI N 14.5 standard requirements and will require implementation of alternative compensatory measures in lieu of the standard's requirements. In addition, the new standard mandates implementation of additional requirements for leak rate testing performance and personnel qualifications during routine maintenance of Type B casks by owner and during operations of casks by users. The focus of the paper will be to discuss ANSI N 14.5-2014 requirements and provide specific examples on how these requirements will impact the current leak rate test practices. This will be illustrated based on several Type B cask models operated within EnergySolutions fleet (both newer and legacy cask designs). Finally, the paper will cover considerations of the cask closure design features that have to be considered by Type B cask designers in order to ensure robustness of leak testing during design, fabrication and, most importantly, operation of a package. This information shall benefit both owners and users of Type B casks with respect to improvement of the cask designs and Type B cask operational experience. (author)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Air Leakage Rates in Typical Air Barrier Assemblies

Estimates for 2010 indicate that infiltration in residential buildings was responsible for 2.85 quads of energy (DOE 2014), which is about 3% of the total energy consumed in the US. One of the mechanisms being implemented to reduce this energy penalty is the use of air barriers as part of the building envelope. These technologies decrease airflow through major leakage sites such as oriented strand board (OSB) joints, and gaps around penetrations (e.g., windows, doors, pipes, electrical outlets) as indicated by Hun et al. (2014). However, most air barrier materials do not properly address leakage spots such as wall-to-roof joints and wall-to-foundation joints because these are difficult to seal, and because air barrier manufacturers usually do not provide adequate instructions for these locations. The present study focuses on characterizing typical air leakage sites in wall assemblies with air barrier materials.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Fission Matrix Capability for MCNP Monte Carlo

In a Monte Carlo criticality calculation, before the tallying of quantities can begin, a converged fission source (the fundamental eigenvector of the fission kernel) is required. Tallies of interest may include powers, absorption rates, leakage rates, or the multiplication factor (the fundamental eigenvalue of the fission kernel, k eff ). Just as in the power iteration method of linear algebra, if the dominance ratio (the ratio of the first and zeroth eigenvalues) is high, many iterations of neutron history simulations are required to isolate the fundamental mode of the problem. Optically large systems have large dominance ratios, and systems containing poor neutron communication between regions are also slow to converge. The fission matrix method, implemented into MCNP, addresses these problems.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Thermal and solubility effects on fault leakage during geologic carbon storage

Geologic carbon storage (GCS) is a promising method for reducing anthropogenic CO 2 emissions to the atmosphere. To safely deploy GCS in the field, it is necessary to assess risks and the effect of uncertainty on safe storage. The effect of uncertainty can be quantified using batches of simulations, but the high computational costs of high-resolution simulations necessitate use of reduced-order models (ROMs). Previous work involves ROMs for quantifying the risk of different potential leakage paths from storage reservoirs to shallow formations. However, previous studies on development of fault-leakage ROMs have limited numbers of uncertain parameters and do not explicitly examine impacts of CO 2 solubility and thermal stresses on fault reactivation, which can generate high-permeability pathways and compromise CO 2 storage. Here, we analyze an ensemble of simulations considering CO 2 leakage from a storage reservoir to a shallow aquifer through a fault while varying a number of uncertain parameters related to thermo-hydro-mechanical properties and CO 2 injection. We show the effects of solubility on: free-phase CO 2 -leakage rates, brine-leakage rates, and poroelastic fault destabilization. We find that CO 2 solubility is more important for estimating free-phase CO 2 -leakage rates compared to brine-leakage rates or poroelastic fault destabilization. We also find that thermal stresses and overpressures have different spatial distributions within the fault, indicating that the spatial variability of overpressures due to variation in flow parameters does not necessarily make the spatial variability of thermal stresses negligible. We suggest the use of the CO 2 phase-change path as a variable in future fault-leakage ROMs.

03 NATURAL GAS↗

Evaluation of mitigation strategies for radioactive fission gases in fluoride-salt-cooled high-temperature reactors

Here, the Fluoride-salt-cooled High-temperature Reactor (FHR) is a promising Generation IV nuclear reactor due to its improved safety design, near atmospheric working pressure, and high electric power conversion efficiency. However, control of radioactive fission gases, such as tritium, is a critical issue in FHRs due to the significantly larger production rate and potentially larger leakage rate of tritium compared to those in Light Water Reactors (LWRs). Therefore, this study proposes two mitigation strategies for tritium in FHRs: Double-Wall Heat eXchanger with a Tritium Carrier (DWHX-TC) option and Single-Wall Heat eXchanger with a Tritium Barrier (SWHX-TB) option. For the DWHX-TC option, two tube surface configurations, i.e., plain and fluted tubes, and four tritium carriers, i.e., helium, FLiBe, FLiNaK, and KF-ZrF 4 , are initially considered, among which the best tube configuration and promising tritium carrier are then selected and used for design optimization of the DWHX. For the SWHX-TB option, two cases, tritium barriers with and without cracks, are investigated in this study. In addition, the two mitigation strategies are evaluated by an in-house, one-dimensional, coupled HEat and MAss Transfer (HEMAT) code developed to predict the leakage rate of tritium in nuclear systems. Our analysis shows that (1) a double-wall configuration using fluted tubes as both the inner and outer tubes is better than other double-wall configurations investigated; (2) helium, as a tritium carrier, is superior to other candidates, including FLiBe, FLiNaK, and KF-ZrF 4 ; (3) the leakage rate of tritium (into the atmosphere) is reduced from 3400 Ci/day, taking the Advanced High-Temperature Reactor (AHTR) as a reference, to 4.0 Ci/day for an optimum design of the DWHX-TC option using helium as the tritium carrier and 1.7 Ci/day for an optimum design of the SWHX-TB option using 30-µm thick silicon carbide (SiC) as the tritium barrier (no cracks); and (4) potential cracks in tritium barriers may significantly deteriorate mass transfer performance of the SWHX-TB option. For example, a cracking rate of 0.1% leads to an increase of 694.1% in the leakage rate under the conditions investigated.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

TA [2] Continuous, regional methane emissions estimates in northern Pennsylvania gas fields using atmospheric inversions

Natural Gas (NG) production activities in the northeastern Marcellus shale have significantly increased in the last decade, possibly releasing large amounts of methane (CH 4 ) into the atmosphere from the operations at the productions sites and during the processing and transmission steps of the natural gas chain. Based on an intensive aircraft survey, leakage rates from the NG production were quantified in May 2015 and found to be in the order of 0.5% of the total production, higher than reported by the Environmental Protection Agency (EPA) but below the usually observed leakage rates over the shale gases in the US. Thanks to the high production rates on average at each well, leakage rates normalized by production appeared to be low in the northeastern Marcellus shale. This result confirms that natural gas production using unconventional techniques in this region is emitting relatively less CH 4 into the atmosphere than other shale reservoirs. The low emissions rate can be explained in part by the high productivity of wells drilled across the northeastern Marcellus region. We demonstrated here that atmospheric monitoring techniques can provide an independent quantification of NG leakage rates using aircraft measurements. The CH 4 analyzers were successfully calibrated at four sites across the region, measuring continuously the atmospheric CH 4 mixing ratios and isotopic 13 Ch 4 . Our preliminary findings confirm the low leakage rates from tower data collected over September 2015 to November 2016 compared to the aircraft mass-balance estimates in may 2015. However, several episodes revealing large releases of natural gas over several weeks showed that temporal variations in the emissions of CH 4 may increase the actual leakage rate over longer time periods.

03 NATURAL GAS↗

Dynamic risk assessment for geologic CO 2 sequestration

At a geologic CO 2 sequestration (GCS) site, geologic uncertainty usually leads to large uncertainty in the predictions of properties that influence metrics for leakage risk assessment, such as CO 2 saturations and pressures in potentially leaky wellbores, CO 2 /brine leakage rates, and leakage consequences such as changes in drinking water quality in groundwater aquifers. The large uncertainty in these risk-related system properties and risk metrics can lead to over-conservative risk management decisions to ensure safe operations of GCS sites. The objective of this work is to develop a novel approach based on dynamic risk assessment to effectively reduce the uncertainty in the predicted risk-related system properties and risk metrics. We demonstrate our framework for dynamic risk assessment on two case studies: a 3D synthetic example and a synthetic field example based on the Rock Springs Uplift (RSU) storage site in Wyoming, USA. Results show that the U.S. National Risk Assessment Partnership’s Open Source Integrated Assessment Model (NRAP-Open-IAM) coupled with a conformance evaluation can be used to effectively quantify and reduce the uncertainty in the predictions of risk-related system properties and risk metrics in GCS.

58 GEOSCIENCES↗

SU-E-T-628: Effect of Dose Rate and Leakage Correction for Dosimetric Leaf Gap Measurement

Purpose: To study the dose rate response of Mapcheck and quantify/correct dose rate/leakage effect on IMRT QA. Evaluate the dose rate/leakage effect on dosimetric leaf gap (DLG) measurement. Methods: Varian Truebeam Linac with HD120 MLC was used for all measurement, it is capable to adjust dose rate from 600MU/min to 5MU/min. Fluke Advanced Therapy Doisemter and PTW 30013 Farmer chamber for chamber measurement; SunNuclear Mapcheck2 with 5cm total buildup for diode measurement. DLG was measured with both chamber and diode.Diode response was measured by varies dose rate, while fixed mapcheck setup and total MU. MLC Leakage was measured with both chamber and diode. Mapcheck measurement was saved as movie file (mcm file), which include measurement updated every 50mSec. The difference between intervals can be converted to dose and dose rate and leakage response correction can be applied to them. Results: DLG measurement results with chamber and diode were showed as follows, the DLG value is 0.36 vs. 0.24mm respectively. Diode dose rate response drops from 100% at 600MU/min to 95.5% at 5MU/min as follows. MLC Leakage measured with diode is 1.021%, which is 9% smaller than 1.112% from chamber measurement. By apply the dose rate and leakage correction, the residue error reduced 2/3. Conclusions: Diode has lower response at lower dose rate, as low as 4.5% for 5MU/min; diode has lower energy response for low energy too, 5% lower for Co-60 than 6MV. It partially explains the leakage difference of 9% between chamber and diode. Lower DLG with diode is because of the lower response at narrower gap, in Eclipse however DLG need to increase to makeup lower response, which is over correction for chamber though. Correction can reduce error by 2/3, the rest 1/3 can be corrected by scatter effect, which is under study.

07 ISOTOPE AND RADIATION SOURCES↗

Above zone pressure interpretation for leaky well characterization and its identification from leaky caprock/fault

Pressure transient analysis has long been used for reservoir characterization. Above-zone (AZ) pressure has been recently investigated for inferring leakage pathway characteristics in leakage events from subsurface injection operations. The recorded pressure in the AZ should be purely related to leakage and therefore it can be safely inverted to deduce leakage characteristics. It is crucial to evaluate fluid leakage through abandoned wells to plan for further measurements of leakage prevention. However, the recorded AZ leakage signal may not be related to leaky well(s). Therefore, identification and spatial investigation of well leakage is required for leakage evaluation. Here in this paper, we propose a pressure interpretation method for early detection of leaky pathways, applying two observation points in the AZ. We distinguish leaky well, fault and caprock based on their corresponding flow regime identification. We show that the pressure difference of the two observation wells can be applied as a proxy for unknown leakage rate, which is crucial for leakage identification as well as characterization. Results show that the estimated location of the leaky well, leakage coefficient, and the leakage rate are in good agreement with the actual values. The estimated leakage coefficient of the leaky well can be used to evaluate well leakage in multiphase systems such as carbon dioxide leakage in deep saline aquifers.

02 PETROLEUM↗

SENSMG: First-Order Sensitivities of Neutron Reaction Rates, Reaction-Rate Ratios, Leakage, k eff , and α Using PARTISN

SENSMG is a tool for calculating the first-order sensitivities of reaction-rate ratios, k eff , and α in critical problems and reaction-rate ratios, reaction rates, and leakage in fixed-source problems to multigroup cross sections, isotope densities, material mass densities, and interface locations using the PARTISN multigroup discrete-ordinates code by implementing Generalized Perturbation Theory. SENSMG can be used for one-dimensional spherical and slab (r) and two-dimensional cylindrical (r-z) geometries. For fixed-source (leakage) problems, SENSMG relies on the MISC and/or SOURCES4C codes to compute neutron source rate densities from spontaneous fission and (α,n) sources. SENSMG is a combination of Python and Fortran and was developed under Linux. This computer code abstract describes all user inputs, the input file, and output files. Furthermore, this computer code abstract describes how SENSMG can be modified to support different computer platforms, PARTISN versions, or cross-section availability. Several verification problems are presented in which SENSMG results are compared with MCNP6, SCALE6.2, and direct perturbations (central differences).

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

SENSMG: First-Order Sensitivities of Neutron Reaction Rates, Reaction-Rate Ratios, Leakage, k eff , and α Using PARTISN

SENSMG is a tool for computing first-order sensitivities of neutron reaction rates, reaction-rate ratios, leakage, k eff , and α using the PARTISN multigroup discrete-ordinates code. SENSMG computes sensitivities to all of the transport cross sections and data (total, fission, nu, chi, and all scattering moments), two edit cross sections (absorption and capture), and the density for every isotope and energy group. It also computes sensitivities to the mass density for every material and derivatives with respect to all interface locations. The tool can be used for one-dimensional spherical (r) and two-dimensional cylindrical (r-z) geometries. The tool can be used for fixed-source and eigenvalue problems. The tool implements Generalized Perturbation Theory (GPT) as discussed by Williams and Stacey. Section II of this report describes the theory behind adjoint-based sensitivities, gives the equations that SENSMG solves, and defines the sensitivities that are output. Section III describes the user interface, including the input file and command line options. Section IV describes the output. Section V gives some notes about the coding that may be of interest. Section VI discusses verification, which is ongoing. Section VII lists needs and ideas for future work. Appendix A lists all of the input files whose results are presented in Sec. VI.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

NRAP-Open-IAM: Open Wellbore Component (V.2.0)

The Open Wellbore component of NRAP-Open-IAM is applicable to the calculation of Area of Review at a carbon storage site and fast estimation of dense gas dispersion from multiple continuous CO 2 surface leakage sources for risk assessment. The Open Wellbore Component of NRAP-Open-IAM is a lookup table model based on the drift-flux approach. The National Research Assessment Partnership’s second-generation integrated assessment model, NRAP-Open-IAM, is open-source software written in Python for use in performance and quantitative risk assessment of geologic carbon storage (GCS) systems. The look-up table for open well leakage is an updated version the previous model which provides finer resolution of reservoir depth and more accurate fluid properties than the previous open well look-up table, especially in calculating the gas (CO 2 -rich) phase properties. The component model input parameters include the reservoir transmissivity, aquifer transmissivity, brine salinity, well radius, and well top and bottom depths. The reservoir transmissivity and brine salinity were set to values consistent with the reservoir component, and the well top and bottom depths varied with location. The possible outputs from the Open Wellbore component are leakage rates of CO 2 and brine to either an aquifer or atmosphere, depending on the depth of the well top. Several python test scripts are presented that demonstrate that the Open Wellbore component works correctly. Use of the open wellbore model in NRAP-Open-IAM may result in a large CO 2 leakage rates, comparable to the leakage rates of CO 2 blow out.

54 ENVIRONMENTAL SCIENCES↗

New Air- and Water-Resistive Barriers -– Technology Verification

Infiltration and exfiltration are among the largest envelope-related contributors to the heating, ventilation, and air conditioning (HVAC) loads in commercial buildings. Air leakage is responsible for about 6% of the total energy used by the commercial building sector. New air sealing technologies have recently emerged that aim to improve the performance of air barrier systems by simplifying their installation procedure. These include the 3M 3015 primer-less self-adhered membrane, 3M 3015VP vapor permeable primer-less self-adhered membrane, and 3M 2085VP vapor permeable fluid-applied air barrier membrane. ORNL verified the performance of the 3M 3015, 3015VP and 2085VP air- and water- resistive barriers by conducting two field studies. The first one involved side-by-side evaluations in eight unoccupied test facilities in Cottage Grove, MN, that included the 3M membranes and commonly used air barrier materials such as a self-adhered membrane with primer and a mechanically-fastened membrane with taped joints. The facilities were monitored for 24 months and the collected data were used to calibrate simulation models that in turn were employed to calculate energy consumption and savings because of improvements in airtightness. After two years, results indicate that the test facilities with the new 3M technologies had leakage rates that were slightly lower than the buildings with traditional air barrier materials. The calibrated model for the test facility with the 3M 3015 membrane was used to calculate energy savings due to improved airtightness when compared to a building without an air barrier. Findings suggest that a building in Minneapolis, MN, or Fairbanks, AK, that has a properly installed air barrier system can have annual HVAC electricity use that is about 36% lower than if the building did not have an air barrier. Similarly, decreases in natural gas use can be about 25%. The second field evaluation involved the LifeSource building in Minneapolis, MN, and the Sierra Trading Post building in Woodbury, MN. Both of these were recently completed and use the 3M 3015 and 3015VP membranes as their air- and water- resistive barriers, respectively. Blower door test results show that LifeSource has an average air leakage rate of 0.06 cfm/ft 2 at 75 Pa, or 85% lower than the 0.4 cfm/ft 2 at 75 Pa specified in the 2015 International Energy Conservation Code (IECC). The leakage rate in the Sierra building is 0.15 cfm/ft 2 at 75 Pa or 63% than the IECC value. According to simulation results, LifeSource lowered its annual heating and cooling cost by about $\$$4600 or 10% when compared to a similar building that lacked an air barrier system. In the case of the Sierra building, savings were $5,900 or 41%. These field evaluations serve as examples of the level of building envelope airtightness that can be achieved by using air barrier materials that are properly installed, and illustrate the energy and financial savings that building envelopes with low air leakage rates could attain.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

(U) SENSMG: First-Order Sensitivities of Neutron Reaction Rates, Reaction-Rate Ratios, Leakage, k eff , α, and Subcritical Multiplication Using PARTISN

SENSMG is a tool for computing first-order sensitivities of neutron reaction rates, reaction-rate ratios, leakage, keff, α, and subcritical multiplication using the PARTISN multigroup discrete-ordinates code.1 SENSMG computes sensitivities to all of the transport cross sections and data (total, fission,a nu, chi, and all scattering moments), four edit cross sections (absorption, capture, elastic scattering, and inelastic scattering), and the density for every isotope and energy group. It also computes sensitivities to the mass density for every material and derivatives with respect to all interface locations and outer boundaries. The tool can be used for one-dimensional spherical and slab (r) and two-dimensional cylindrical (r-z) geometries.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗