Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “leakage rate”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Measurements of the atmospheric neutron leakage rate

The atmospheric neutron leakage rate in the energy range from 0.01 to 10,000,000 eV has been measured as a function of latitude, altitude, and time with a neutron detector on board the Ogo 6 satellite. The latitude dependence of the neutron leakage is in reasonable agreement with that predicted by Lingenfelter (1963) and Light et al. (1973) if the neutron energy spectrum has the shape calculated by Newkirk (1963). The change in the neutron latitude dependence with the cosmic ray modulation agrees with the predictions of Lingenfelter and Light et al. For several solar proton events enhancements were observed in the neutron counting rates at lambda greater than or equal to 70 deg. Such events, however, provide an insignificant injection of protons at E less than or equal to 20 MeV into the radiation belts. An isotropic angular distribution of the neutron leakage in the energy range from 0.1 keV to 10 MeV best fits the observed altitude dependence of the neutron leakage flux.

Lockwood, J. A.↗

3-60B Type-B shipping cask enhanced operational features to facilitate leakage rate testing - 15585

EnergySolutions is fabricating a new 3-60B Type B Shipping Cask that will be ready for use in spring 2015, designed for shipping Type B quantities of activated and/or non-fuel-bearing reactor or accelerator components. EnergySolutions, in consult with Leak Testing Specialists, Inc., has implemented an improved design of the 3-60B cask closures to better facilitate periodic and maintenance leakage rate testing and to allow end users to more easily perform pre-shipment leakage rate testing to confirm proper assembly of the cask closures. A typical Type B cask closure lid design incorporates a double O-ring configuration, where the inner O-ring provides containment and the outer O-ring is used for leakage rate testing of the containment O-ring seal. Leakage rate testing of a double O-ring configuration is typically accomplished by filling the cask cavity with helium, pulling a vacuum on the annular space between the two O-rings and monitoring for helium leakage through the containment O-ring. One issue is the potential for helium saturation of the O-ring elastomeric material, which can result in leakage rate test failures. The cask cavity volume is typically large, and takes a significant amount of time to fill with helium. As a result, the saturation time for certain elastomeric compounds may be exceeded, leading to potential false-negative leakage rate testing results. To avoid this, that the cask cavity typically is loaded with sealed container(s) to reduce the free volume and the fill time. The improved 3-60B cask closure lid incorporates a triple O-ring seal configuration that facilitates maintenance leak rate testing of the closure lid containment O-ring seal and eliminates the issues discussed above. The triple O-ring configuration uses the middle O-ring as the containment seal, with the inner and outer test O-rings creating relatively small annular volumes for testing purposes. These small annular volumes are quick to fill, minimizing the issue of Helium saturation of the O-ring material. This seal configuration also makes it possible to detect and replace a damaged O-ring seal during loading operations, or dress a damaged sealing surface, and perform the required maintenance leakage rate testing of the replacement O-ring at the plant site without the need to unload the cask and send it to a maintenance facility. Also, a second test port has been added to each O-ring annulus to allow leakage rate testing to be accomplished using a formal system calibration that complies with the requirements and recommendations of ASME Section V, Article 10 [4], ANSI N14.5-97 [2], and ANSI N14.5-2014 [3]. This provides a simple, reliable, and accurate means to perform leakage rate testing with a test confidence level that cannot be achieved without the second test port. The improved closure and test port design simplifies and shortens the time required to perform leakage testing, resulting in reduced operating costs, greater schedule security, and dose savings for the cask users. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Vent and relief valve maintains low leakage rate over broad temperature range

Low leakage rate, large diameter vent and relief valve operates satisfactorily over a large temperature range by a design that accommodates waviness and distortions due to thermal gradients. It is based on a fixed sealing member having an inclined lapped surface to which a flexible flow gate conforms.

Weitenbeck, R. G.↗

Leakage Rate Testing Considerations and Implementation of ANSI N 14.5-2014 Standard within EnergySolutions Type (B) cask fleet - 18629

In March 2016, Nuclear Regulatory Commission (NRC) staff issued Information Notice 2016-04: 'ANSI N14.5-2014 Revision and leakage rate testing considerations'. American National Standards Institute (ANSI) N14.5, 'American National Standard for Radioactive Materials-Leakage Tests on Packages for Shipment', applies to leakage rate testing of Low Level Radioactive Waste (LLRW) Type B packages operated under 10CFR71. In their information notice NRC is encouraging Type B cask license holders and licensees (cask users) to adapt a new version of ANSI N 14.5 standard. Typically, leakage rate testing for Type B packages (or casks) is performed at different stages of cask development (design and fabrication leak tests) and operations (periodic/maintenance and pre-shipment leak tests) with the purpose to reasonably assure that the packaging will contain radioactive material under both normal and hypothetical accident conditions of transport described in 10CFR71. The standard was updated to provide a modern, robust and standardized approach for performance of leak rate testing on Type B casks by the industry stakeholders. Although implementation of new version of the leak testing standard may not be problematic for a modern Type B package designs, it may be extremely challenging to apply its principles to the existing legacy Type B casks which were designed/fabricated more then 20-30 years ago based on older requirements. Majority of such casks are not 'leak test' friendly. Some of legacy Type B packages may not readily available to meet newer ANSI N 14.5 standard requirements and will require implementation of alternative compensatory measures in lieu of the standard's requirements. In addition, the new standard mandates implementation of additional requirements for leak rate testing performance and personnel qualifications during routine maintenance of Type B casks by owner and during operations of casks by users. The focus of the paper will be to discuss ANSI N 14.5-2014 requirements and provide specific examples on how these requirements will impact the current leak rate test practices. This will be illustrated based on several Type B cask models operated within EnergySolutions fleet (both newer and legacy cask designs). Finally, the paper will cover considerations of the cask closure design features that have to be considered by Type B cask designers in order to ensure robustness of leak testing during design, fabrication and, most importantly, operation of a package. This information shall benefit both owners and users of Type B casks with respect to improvement of the cask designs and Type B cask operational experience. (author)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Vacuum test fixture improves leakage rate measurements

Cylindrical chamber, consisting of two matching halves, forms a vacuum test fixture for measuring leakage rates of individual connections, brazed joints, and entrance ports used in closed fluid flow line systems. Once the chamber has been sufficiently evacuated, atmospheric pressure holds the two halves together.

Maier, H.↗

Space Station Freedom delta pressure leakage rate comparison test data analysis report

Results are provided of a series of tests performed to identify the relationship between gas leakage rates across a seal at various internal to external pressure ratios. The results complement and provide insight into the analysis technique used to obtain the results presented in MSFC SSF/DEV/EL91-008, 'Space Station Freedom (S.S. Freedom) Seal Flaw Study with Delta Pressure Leak Rate Comparison Test Report.'

Sorensen, E. B.↗

Air Leakage Rates in Typical Air Barrier Assemblies

Estimates for 2010 indicate that infiltration in residential buildings was responsible for 2.85 quads of energy (DOE 2014), which is about 3% of the total energy consumed in the US. One of the mechanisms being implemented to reduce this energy penalty is the use of air barriers as part of the building envelope. These technologies decrease airflow through major leakage sites such as oriented strand board (OSB) joints, and gaps around penetrations (e.g., windows, doors, pipes, electrical outlets) as indicated by Hun et al. (2014). However, most air barrier materials do not properly address leakage spots such as wall-to-roof joints and wall-to-foundation joints because these are difficult to seal, and because air barrier manufacturers usually do not provide adequate instructions for these locations. The present study focuses on characterizing typical air leakage sites in wall assemblies with air barrier materials.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Fission Matrix Capability for MCNP Monte Carlo

In a Monte Carlo criticality calculation, before the tallying of quantities can begin, a converged fission source (the fundamental eigenvector of the fission kernel) is required. Tallies of interest may include powers, absorption rates, leakage rates, or the multiplication factor (the fundamental eigenvalue of the fission kernel, k eff ). Just as in the power iteration method of linear algebra, if the dominance ratio (the ratio of the first and zeroth eigenvalues) is high, many iterations of neutron history simulations are required to isolate the fundamental mode of the problem. Optically large systems have large dominance ratios, and systems containing poor neutron communication between regions are also slow to converge. The fission matrix method, implemented into MCNP, addresses these problems.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Thermal and solubility effects on fault leakage during geologic carbon storage

Geologic carbon storage (GCS) is a promising method for reducing anthropogenic CO 2 emissions to the atmosphere. To safely deploy GCS in the field, it is necessary to assess risks and the effect of uncertainty on safe storage. The effect of uncertainty can be quantified using batches of simulations, but the high computational costs of high-resolution simulations necessitate use of reduced-order models (ROMs). Previous work involves ROMs for quantifying the risk of different potential leakage paths from storage reservoirs to shallow formations. However, previous studies on development of fault-leakage ROMs have limited numbers of uncertain parameters and do not explicitly examine impacts of CO 2 solubility and thermal stresses on fault reactivation, which can generate high-permeability pathways and compromise CO 2 storage. Here, we analyze an ensemble of simulations considering CO 2 leakage from a storage reservoir to a shallow aquifer through a fault while varying a number of uncertain parameters related to thermo-hydro-mechanical properties and CO 2 injection. We show the effects of solubility on: free-phase CO 2 -leakage rates, brine-leakage rates, and poroelastic fault destabilization. We find that CO 2 solubility is more important for estimating free-phase CO 2 -leakage rates compared to brine-leakage rates or poroelastic fault destabilization. We also find that thermal stresses and overpressures have different spatial distributions within the fault, indicating that the spatial variability of overpressures due to variation in flow parameters does not necessarily make the spatial variability of thermal stresses negligible. We suggest the use of the CO 2 phase-change path as a variable in future fault-leakage ROMs.

03 NATURAL GAS↗

Evaluation of mitigation strategies for radioactive fission gases in fluoride-salt-cooled high-temperature reactors

Here, the Fluoride-salt-cooled High-temperature Reactor (FHR) is a promising Generation IV nuclear reactor due to its improved safety design, near atmospheric working pressure, and high electric power conversion efficiency. However, control of radioactive fission gases, such as tritium, is a critical issue in FHRs due to the significantly larger production rate and potentially larger leakage rate of tritium compared to those in Light Water Reactors (LWRs). Therefore, this study proposes two mitigation strategies for tritium in FHRs: Double-Wall Heat eXchanger with a Tritium Carrier (DWHX-TC) option and Single-Wall Heat eXchanger with a Tritium Barrier (SWHX-TB) option. For the DWHX-TC option, two tube surface configurations, i.e., plain and fluted tubes, and four tritium carriers, i.e., helium, FLiBe, FLiNaK, and KF-ZrF 4 , are initially considered, among which the best tube configuration and promising tritium carrier are then selected and used for design optimization of the DWHX. For the SWHX-TB option, two cases, tritium barriers with and without cracks, are investigated in this study. In addition, the two mitigation strategies are evaluated by an in-house, one-dimensional, coupled HEat and MAss Transfer (HEMAT) code developed to predict the leakage rate of tritium in nuclear systems. Our analysis shows that (1) a double-wall configuration using fluted tubes as both the inner and outer tubes is better than other double-wall configurations investigated; (2) helium, as a tritium carrier, is superior to other candidates, including FLiBe, FLiNaK, and KF-ZrF 4 ; (3) the leakage rate of tritium (into the atmosphere) is reduced from 3400 Ci/day, taking the Advanced High-Temperature Reactor (AHTR) as a reference, to 4.0 Ci/day for an optimum design of the DWHX-TC option using helium as the tritium carrier and 1.7 Ci/day for an optimum design of the SWHX-TB option using 30-µm thick silicon carbide (SiC) as the tritium barrier (no cracks); and (4) potential cracks in tritium barriers may significantly deteriorate mass transfer performance of the SWHX-TB option. For example, a cracking rate of 0.1% leads to an increase of 694.1% in the leakage rate under the conditions investigated.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Low Leakage Valves for Long Duration Missions

I.Nomenclaturemtypical_mission=internal mass of propellant lost over the course of a mission with Qtypicalmmission_goal=mass of propellant loss over the course of a mission with Qgoaltmission=theoretical mission durationQtypical=internal leakage rate found in commercially available valvesQgoal=internal leakage rate design goalρH2_STP=density of hydrogen at standard temperature and pressure.1NASA AST, Liquid Propulsion Valve Engineer.Valves, Actuators, and Ducts Design and Development Branch (ER14)2NASA AST, Liquid Propulsion Valve Engineer.Valves, Actuators, and Ducts Design and Development Branch (ER14)3NASA AST, Liquid Propulsion Valve Engineer (Retired).Valves, Actuators, and Ducts Design and Development Branch (ER14)4JSEG ESSCA, Engineering Specialist.Valves Actuators and Ducts Design and Development Branch (ER14)5NASA AST, Liquid Propulsion Valve Engineer.Valves, Actuators, and Ducts Design and Development Branch (ER14)6JSEG ESSCA, Valve Design and Development Engineer.Valves Actuators and Ducts Design and Development Branch (ER14) II.IntroductionCurrent aerospace cryogenic valves present challenges to potential long duration missions that utilize cryogenic propellants. Small interplanetary and long-life communication satellites typically utilize hypergolic propellants that operate at higher temperatures, making it easier to achieve very low internal leakage rates. Larger vehicles for long duration missions will likely need to utilize cryogenic-based chemical and nuclear systems to achieve mission requirements. Some early propulsion concepts are projected to require valves with a nominal size ranging from 3” to 10”.Currently available cryogenic aerospace valves typically have internal leakage rates which can range from 100 to 300 SCIM for 3” valves, or upwards of 2,000 SCIM for 10” valves. With just a few of these valves in a system, internal leakage could account for multiple tons of propellant loss over the course of a potential Mars mission, as shown in Figure 1.Figure 1 - Potential Propellant Loss Over the Course of a Long Duration MissionMost internal leakage rates can be attributed to inherent imperfections and misalignments, which result in imperfect contact between sealing surfaces, as shown in Figure 2.Figure 2 - Imperfections and Misalignments Between Sealing Surfaces The ER14 Branch at Marshall Space Flight Center (MSFC) has created a self-aligning seat and poppet design (shown in Figure 3) that allows a valve to be more tolerant of imperfect contacts. This design utilizes a metallic poppet head with five degrees of freedom that allows the poppet toself-align with the seat, reducing the need for tight tolerances.Figure 3 - Self-Aligning Seat and Poppet DesignIII.Test Valve DescriptionA series of development tasks have been conducted to study potential improvements to internal leakage rates. These tasks include 3 test valves (shown in Figure 4) to demonstrate the potential application to various configurations and sizes:A 3” isolation valve for liquid flows (similar to a fill and drain valve)A 3” relief valve for low temperature gas flows.An 8” pre-valve (similar to the engine isolation valve needed on a Nuclear Thermal Propulsion (NTP) engine).Figure 4 - Low Leakage Development Test ValvesThese valves have been developed and are currently being tested at liquid nitrogen (LN2) temperatures, and are anticipated to undergo testing at liquid hydrogen (LH2) temperatures in late 2022

Cody L Gilliland↗

The effects of air leaks on solar air heating systems

This paper presents the results of an investigation to determine the effects of leakages in collector and duct work on the system performance of a typical single-family residence solar air heating system. Positive (leakage out) and negative (leakage in) pressure systems were examined. Collector and duct leakage rates were varied from 10 to 30 percent of the system flow rate. Within the range of leakage rates investigated, solar contribution to heated space and domestic hot water loads was found to be reduced up to 30 percent from the no-leak system contribution with duct leakage equally divided between supply and return duct; with supply duct leakage greater than return leakage a reduction of up to 35 percent was noted. The negative pressure system exhibited a reduction in solar contribution somewhat larger than the positive pressure system for the same leakage rates.

Elkin, R.↗

High temperature performance evaluation of a hypersonic engine ceramic wafer seal

Leakage rates of an innovative hypersonic engine seal were measured using a specially developed static high temperature seal test fixture at NASA Lewis Research Center. The three foot long structural panel-edge seal is designed to minimize leakage of high temperature, high pressure gases past the movable panels of advanced ramjet/scramjet engines. The seal is made of a stack of precision machined ceramic wafer pieces that are inserted into a closely conforming seal channel in the movable engine panel. The wafer seal accommodates the significant distortions in the adjacent engine walls through relative sliding between adjacent wafers. Seal leakage rates are presented for engine simulated air temperatures up to 1350 F and for engine pressures up to 100 psi. Leakage rates are also presented for the seal, sealing both a flat wall condition, and an engine simulated distorted wall condition in which the distortion was 0.15 in. in only an 18 in. span. Seal leakage rates were low, meeting an industry-established tentative leakage limit for all combinations of temperature, pressure, and wall conditions considered. Comparisons are made between the measured leakage rates and leakage rates predicted using a seal leakage model developed from externally-pressurized gas film bearing theory.

Steinetz, Bruce M.↗