Validating data analysis of broadband laser ranging

Broadband laser ranging combines spectral interferometry and a dispersive Fourier transform to achieve high-repetition-rate measurements of the position of a moving surface. Telecommunications fiber is a convenient tool for generating the large linear dispersions required for a dispersive Fourier transform, but standard fiber also has higher-order dispersion that distorts the Fourier transform. Imperfections in the dispersive Fourier transform significantly complicate the ranging signal and must be dealt with to make high-precision measurements. Here, we describe in detail an analysis process for interpreting ranging data when standard telecommunications fiber is used to perform an imperfect dispersive Fourier transform. This analysis process is experimentally validated over a 27-cm scan of static positions, showing an accuracy of 50 μm and a root-mean-square precision of 4.7 μm.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Simultaneous broadband laser ranging and photonic Doppler velocimetry for dynamic compression experiments

A diagnostic was developed to simultaneously measure both the distance and velocity of rapidly moving surfaces in dynamic compression experiments, specifically non-planar experiments where integrating the velocity in one direction does not always give the material position accurately. The diagnostic is constructed mainly from fiber-optic telecommunications components. The distance measurement is based on a technique described by Xia and Zhang [Opt. Express 18, 4118 (2010)], which determines the target distance every 20 ns and is independent of the target speed. We have extended the full range of the diagnostic to several centimeters to allow its use in dynamic experiments, and we multiplexed it with a photonic Doppler velocimetry (PDV) system so that distance and velocity histories can be measured simultaneously using one fiber-optic probe. The diagnostic was demonstrated on a spinning square cylinder to show how integrating a PDV record can give an incorrect surface position and how the ranging diagnostic described here obtains it directly. The diagnostic was also tested on an explosive experiment where copper fragments and surface ejecta were identified in both the distance and velocity signals. We show how the distance measurements complement the velocity data. Potential applications are discussed.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Calibration of a single-point laser range finder and a camera

Laser and visual imagery have been broadly utilized in computer vision and mobile robotics applications because these sensors provide complementary information. Since the single-point laser range finder can provide depth information of a single pixel in the observed image, its price and size is very suitable for handheld devices or very lightweight robotic platforms. So the combination of a single-point laser range finder and a camera has become increasingly useful in recent report and industrial applications. In this paper, we propose two accurate calibration methods for determining the position and direction of the laser range finder relative to the camera. Furthermore, we can accomplish calibration even without observing the laser spot in camera image. We evaluate the two methods through experiments which demonstrate their efficiency and high reliability.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Enhancing the signal-to-noise ratio for laser ranging by adjusting the photon equivalent threshold of a multi-pixel photon counter

A photon equivalent (PE) threshold-adjusting regime for laser ranging is proposed based on a multi-pixel photon counter (MPPC), and the mechanism of PE threshold influence on the signal-to-noise ratio (SNR) is demonstrated and analysed. The unique PE threshold adjustability of an MPPC leads to interesting results for laser ranging. Experimental results show that the SNR of the laser ranging system is significantly improved by optimising the MPPC PE threshold, which is beneficial for detection and false alarm probabilities. Submillimeter laser ranging resolution is obtained with noncooperative targets placed several meters away. Nanosecond dead time single photon laser ranging without gating is obtained due to an MPPC with a small pixel area. Multiple target ranging is implemented with a single MPPC rather than an array. (laser applications and other topics in quantum electronics)

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Broadband Laser Ranging: Signal Analysis and Interpretation

Broadband laser ranging (BLR) is essentially a spectral interferometer used to infer distance to a moving target. The light source is a mode-locked fiber laser, and chromatic dispersion maps the spectral interference pattern into the time domain, yielding chirped beat signals at the detector. A BLR record is a sequence of these chirped signals, representing consecutive target positions. To infer distance to a target, each underlying pulse envelope must be consistently registered and subtracted despite environmentally-induced variability. Then, nonlinear transformation of the phase is applied to remove the chirp, an FFT is performed to determine the peak frequency of the de-chirped signal, and a calibration factor relating de-chirped frequency to distance results in target position. This article discusses these analysis steps are in detail.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

An Overview of Broadband Laser Ranging (BLR) Architecture and Measurement Considerations

Broadband Laser Ranging (BLR) is a developmental diagnostic intended to measure the position of rapidly moving surfaces in combination with optical velocimetry. Design and employment of a BLR diagnostic on dynamic experiments requires consideration for both the inherent measurement system tradeoffs as well as architectural choices appropriate to the nature of investigation. The diagnostic uses spectral interferometry to measure distance by mapping femtosecond laser pulses to the time domain via chromatic dispersion within the fiber-optic architecture. The system parameters and governing equations that describe measurement range, resolution, and Doppler sensitivity will be discussed. We will also briefly review the impact of diagnostic architectural choices including: nature of interferometer, Interferometric dispersion matching, optical amplification, integration of optical velocimetry, BLR calibration, and field operability. To summarize we will present the architectural and operational approach currently being pursued by NSTec within an on-going collaboration between NSTec, Lawrence Livermore and Los Alamos National Labs.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Note: Digital laser frequency auto-locking for inter-satellite laser ranging

We present a prototype of a laser frequency auto-locking and re-locking control system designed for laser frequency stabilization in inter-satellite laser ranging system. The controller has been implemented on field programmable gate arrays and programmed with LabVIEW software. The controller allows initial frequency calibrating and lock-in of a free-running laser to a Fabry-Pérot cavity. Since it allows automatic recovery from unlocked conditions, benefit derives to automated in-orbit operations. Program design and experimental results are demonstrated.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Active laser ranging with frequency transfer using frequency comb

A comb-based active laser ranging scheme is proposed for enhanced distance resolution and a common time standard for the entire system. Three frequency combs with different repetition rates are used as light sources at the two ends where the distance is measured. Pulse positions are determined through asynchronous optical sampling and type II second harmonic generation. Results show that the system achieves a maximum residual of 379.6 nm and a standard deviation of 92.9 nm with 2000 averages over 23.6 m. Moreover, as for the frequency transfer, an atom clock and an adjustable signal generator, synchronized to the atom clock, are used as time standards for the two ends to appraise the frequency deviation introduced by the proposed system. The system achieves a residual fractional deviation of 1.3 × 10{sup −16} for 1 s, allowing precise frequency transfer between the two clocks at the two ends.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Blade tip clearance measurement of the turbine engines based on a multi-mode fiber coupled laser ranging system

The blade tip clearance is a parameter of great importance to guarantee the efficiency and safety of the turbine engines. In this article, a laser ranging system designed for blade tip clearance measurement is presented. Multi-mode fiber is utilized for optical transmission to guarantee that enough optical power is received by the sensor probe. The model of the tiny sensor probe is presented. The error brought by the optical path difference of different modes of the fiber is estimated and the length of the fiber is limited to reduce this error. The measurement range in which the optical power received by the probe remains essentially unchanged is analyzed. Calibration experiments and dynamic experiments are conducted. The results of the calibration experiments indicate that the resolution of the system is about 0.02 mm and the range of the system is about 9 mm.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Application of conical 90-degree reflectors for solving the problem of mirror alignment in terahertz-range lasers

We report a study of the conical mirrors with an apex angle of 90° in the resonator of the gas-discharge HCN laser with the radiation wavelength of 337 μm (0.89 THz). Experimental results have shown that such mirrors do not require precise alignment. This makes it possible to improve the radiation stability, significantly simplify the construction of laser and reduce the complexity of its maintenance. (laser applications and other topics in quantum electronics)

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Scannerless laser range imaging using loss modulation

A scannerless 3-D imaging apparatus is disclosed which utilizes an amplitude modulated cw light source to illuminate a field of view containing a target of interest. Backscattered light from the target is passed through one or more loss modulators which are modulated at the same frequency as the light source, but with a phase delay .delta. which can be fixed or variable. The backscattered light is demodulated by the loss modulator and detected with a CCD, CMOS or focal plane array (FPA) detector to construct a 3-D image of the target. The scannerless 3-D imaging apparatus, which can operate in the eye-safe wavelength region 1.4-1.7 .mu.m and which can be constructed as a flash LADAR, has applications for vehicle collision avoidance, autonomous rendezvous and docking, robotic vision, industrial inspection and measurement, 3-D cameras, and facial recognition.

47 OTHER INSTRUMENTATION↗