Dynamic motion trajectory control with nanoradian accuracy for multi-element X-ray optical systems via laser interferometry

The past decades have witnessed the development of new X-ray beam sources with brightness growing at a rate surpassing Moore’s law. Current and upcoming diffraction limited and fully coherent X-ray beam sources, including multi-bend achromat based synchrotron sources and high repetition rate X-ray free electron lasers, puts increasingly stringent requirements on stability and accuracy of X-ray optics systems. Parasitic motion errors at sub-micro radian scale in beam transport and beam conditioning optics can lead to significant loss of coherence and brightness delivered from source to experiment. To address this challenge, we incorporated optical metrology based on interferometric length and angle sensing and real-time correction as part of the X-ray optics motion control system. A prototype X-ray optics system was constructed following the optical layout of a tunable X-ray cavity. On-line interferometric metrology enabled dynamical feedback to a motion control system to track and compensate for motion errors. The system achieved sub-microradian scale performance, as multiple optical elements are synchronously and continuously adjusted. This first proof of principle measurement demonstrated both the potential and necessity of incorporating optical metrology as part of the motion control architecture for large scale X-ray optical systems such as monochromators, delay lines, and in particular, X-ray cavity systems to enable the next generation cavity-based X-ray free electron lasers.

47 OTHER INSTRUMENTATION↗

Investigation of Radius of Curvature Measurements using Laser Interferometry [Slides]

Goals for this work are to: develop an application using a ZYGO Verifire for calibration of artifacts where the measurand is defined as a Radius of Curvature (ROC), validate the measurements through an uncertainty analysis, and determine if the calibration method is a viable alternative/option for calibration outside of current standard methodologies.

42 ENGINEERING↗

Quantum Gravity and Laser Interferometry: Towards Observable Predictions

Understanding quantum gravity remains one of the deepest challenges in modern physics, as direct experimental access to Planck-scale effects is beyond current technological reach. However, recent theoretical advances indicate that quantum fluctuations of spacetime may produce measurable effects in precision experiments, particularly near causal horizons. This opens new avenues for testing quantum gravity phenomena through high-precision measurement techniques. This dissertation develops multiple theoretical models to characterize these effects and examines their potential observational signatures in future gravitational wave interferometers. We begin by investigating the role of quantum fluctuations in near-horizon geometries through the lens of the AdS/CFT correspondence, which provides a powerful framework for understanding the interplay between quantum field theory and general relativity via holographic principles. By modeling stochastic energy-momentum sources in Rindler-AdS spacetime, we demonstrate that vacuum fluctuations transform the Einstein equations into a Langevin-type stochastic differential equation, leading to potentially observable fluctuations in photon traversal times. Extending this approach to Minkowski spacetime, we establish a correspondence between gravitational shockwaves and fluid dynamics, showing that near-horizon perturbations satisfy an equation analogous to that governing incompressible fluids, thereby reinforcing the membrane paradigm and hydrodynamic analogies in the context of the fluid/gravity duality. Furthermore, we construct the covariant phase space of a spherically symmetric causal diamond in Minkowski spacetime, identifying two fundamental charges that govern its evolution. These results provide a foundation for quantizing causal horizons and understanding their microscopic degrees of freedom. Building upon these theoretical developments, we further examine a related stochastic phenomenon: the gravitational wave memory background arising from the cumulative memory steps produced by supermassive black hole mergers. After reviewing the standard stochastic gravitational wave background, gravitational memory effects, and BMS symmetries, we model the stochastic memory background using a Brownian motion framework. We show that while the cumulative memory background initially appears above the sensitivity curve of space-based interferometers like LISA, the realistic subtraction of individually resolvable merger events substantially suppresses the residual signal, making its detection more challenging. This highlights the critical importance of source subtraction when evaluating the detectability of gravitational memory effects. By bridging fundamental theory with experimental prospects, this dissertation contributes to the ongoing effort to uncover the quantum nature of spacetime through precision measurement techniques. Whether through detecting quantum spacetime fluctuations, gravitational memory backgrounds, or probing the symmetries of causal horizons, the pursuit of observable quantum gravity phenomena continues to expand the frontiers of both theory and experiment.

Zhang, Yiwen [Caltech] (ORCID:0000000323559416)↗

H 2 O absorption spectroscopy via focused laser differential interferometry

A modification of focused laser differential interferometry (FLDI) is demonstrated with an infrared tunable diode laser (TDL) to achieve simultaneous absorption spectroscopy (AS) measurements. Measurements from this absorbing-FLDI (A-FLDI) are shown for a Hencken burner plume. Initial comparison measurements are recorded using TDLAS and an electrical hygrometer. Raw voltage and estimated absorbance measurements illustrate that the technique detects five distinct absorbance peaks of the methane–air flame while retaining the expected behavior of typical FLDI. This modification furthers efforts to enable FLDI to conduct analysis of the pressures, temperatures, and molecular densities of flows. It also explores the potential for reducing path-integration (PI) effects in absorption spectroscopy and potentially enabling spatially and temporally resolved local flow measurements. Reductions in PI length as high as 82%–84% are observed.

Holladay, Seth (ORCID:0009000650875421)↗

Proper time observables of general gravitational perturbations in laser interferometry-based gravitational wave detectors

We present an explicitly gauge-invariant observable of any general gravitational perturbation, ℎ 𝜇⁢𝜈 [not necessarily due to gravitational waves (GWs)], in a laser interferometry-based GW detector, identifying the signature as the proper time elapsed of the beamsplitter observer, between two events: when a photon passes through the beamsplitter, and when the same photon returns to the beamsplitter after traveling through the interferometer arm and reflecting off the far mirror. Our formalism applies to simple Michelson interferometers and can be generalized to more advanced setups. We demonstrate that the proper time observable for a plane GW is equivalent to the detector strain commonly used by the GW community, though now the common framework can be easily generalized for other types of signals, such as dark matter clumps or spacetime fluctuations from quantum gravity. We provide a simple recipe for computing the proper time observable for a general metric perturbation in linearized gravity and explicitly show that it is invariant under diffeomorphisms of the perturbation, as any physical observable should be.

Dark matter detectors↗

Coriolis force compensation and laser beam delivery for 100-m baseline atom interferometry

The Coriolis force is a significant source of systematic phase errors and dephasing in atom interferometry and is often compensated by counter-rotating the interferometry laser beam against Earth's rotation. We present a novel method for performing Coriolis force compensation for long-baseline atom interferometry, which mitigates atom-beam misalignment due to beam rotation, an effect which is magnified by the long lever arm of the baseline length. The method involves adjustment of the angle of the interferometer beam prior to a magnifying telescope, enabling the beam to pivot around a tunable position along the interferometer baseline. By tuning the initial atom kinematics and adjusting the angle with which the interferometer beam pivots about this point, we can ensure that the atoms align with the center of the beam during the atom optics laser pulses. This approach will be used in the MAGIS-100 atom interferometer and could also be applied to other long-baseline atom interferometers. An additional challenge associated with long baseline interferometry is that since long-baseline atom interferometers are often located outside of typical laboratory environments, facilities constraints may require lasers to be housed in a climate-controlled room a significant distance away from the main experiment. Nonlinear effects in optical fibers restrict the use of fiber-based transport of the high-power interferometry beam from the laser room to the experiment. We present the design of and prototype data from a laser transport system for MAGIS-100 that maintains robustness against alignment drifts despite the absence of a long fiber.

Glick, Jonah↗

Laser scattering by submicron droplets formed during the electrical explosion of thin metal wires

Abstract This paper presents the results of studying dispersed media formation during the electrical explosion of thin metal wires in vacuum by using low-current generators (~1–10 kA). Particular attention is paid to the analysis of the composition and structure of the corresponding explosion products as well as to the problem of their visualization using simultaneous laser interferometry and shadow imaging at two wavelengths (1.064 µ m and 0.532 µ m). Our findings indicate the important role in the visualization of the explosion products that belongs to multiple scattering by submicron droplets of dense condensed matter, which are mixed with metal vapor. The hypothesis on the existence of submicron droplets in the products of exploding metal wires correlates with the results obtained by soft x-ray radiography combined with a laser probing technique. Taking into account the multiple scattering by submicron droplets, it is possible to significantly clarify the parameters of the explosion products visualized via laser probing techniques as well as to gain a deeper insight into the physics behind the electrical wire explosion.

Physics↗

Multi-diagnostic characterization of laser-produced tin plasmas for EUV lithography

We present a comprehensive characterization of laser-produced tin (Sn) plasmas relevant to extreme ultraviolet (EUV) lithography using a multi-diagnostic suite integrated into the new experimental platform, “SparkLight.” Tin plasmas are generated by irradiating a continuously moving tin-coated wire with laser pulses (1064 nm, 10 ns, up to 5.7 × 10 10 W/cm 2 ) and probed via coherent Thomson scattering, laser interferometry, and EUV emission spectroscopy. Thomson scattering measurements reveal electron temperatures and densities that decay with distance from the target. Densities derived from Thomson scattering are cross-validated against laser interferometry, showing excellent agreement. Correlating the results of these laser diagnostics with spatially resolved EUV spectroscopy suggests that the bulk of useful EUV emission originates within 150 μm of the target and is generated under suboptimal plasma conditions. This work demonstrates a practical integrated approach for plasma characterization in EUV source development.

Musikhin, S. [Princeton Plasma Physics Laboratory ↗

DOE SCGSR Final Report - Project Accomplishments and Additional Materials

The major accomplishments of my project were successfully developing and testing the laser interferometry diagnostic on the Plasma Liner Experiment (PLX) at Los Alamos National Laboratory (LANL). This diagnostic helped advance my research by providing a simpler way to obtain electron density measurements of magnetized plasmas compared to other electron density diagnostics such as triple Langmuir probes. The laser used was a 561 nm continuous wave (CW) diode-pumped solid state (DPSS) laser. The PLX laser interferometry diagnostic consists of two parts. These include the launching and receiving sides of the laser diagnostic. The launching side consists of the main laser beam from the DPSS laser being split into five chords(probe beams) and a reference beam which are then directed with fiber optic couplers into fiber optic cables which transmit the probe beamsto the PLX vacuum chamber. The probe beams then pass through the plasma in the chamber and into the receiving side optics where they are again directed through fiber optic cables to be combined with the reference beam. The combined beams are transmitted via multi-mode fiber optic cables to photodiodes to convert the light signals into electrical signals. Before the electrical signals get digitized, they pass through bandpass and low pass filters to eliminate electromagnetic noise and unwanted frequencies. The electrical signals are then processed by IQ demodulators to determine phase angle difference between the probe and reference beams for each chord in order to calculate line-integrated electron density.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Optical Response of Soda-Lime Glass Shocked to 14 GPa

To investigate the potential use of soda-lime glass (SLG) as an optical window in shock wave experiments, laser interferometry (VISAR) was used to determine the window correction and the refractive index in SLG samples subjected to plane shock wave compression. Symmetric plate impact experiments were conducted at peak stresses varying between 4 and 14 GPa and laser interferometry ($λ_0$ = 532$\textit {nm}$ wavelength) measurements were used to monitor the particle velocity histories at the impact surface. The higher stress experiments displayed a constant state prior to stress unloading. In contrast, the lower stress experiments (4.3 and 7.8 GPa) displayed an initial constant state followed by weakly time-dependent response prior to stress unloading. Because the actual particle velocities were independently known from the projectile velocity measurements, the window correction factor and the refractive index changes were determined over the stress range examined. Above 7.5 GPa, our window correction and refractive index results show significant differences with previously published data for the same material. Potential reasons for these differences are indicated.

36 MATERIALS SCIENCE↗

Hugoniot states and optical response of soda lime glass shock compressed to 120 GPa

In contrast to relatively pure silica glass (fused silica-FS), commercial silica-rich glasses contain significant fractions of additional oxide components. In particular, soda-lime glass (SLG) consists of approximately 71% SiO 2 by weight, which raises the question: what is the effect of additional cations on the shock compression response of silica-rich glasses? To address this concern, plate impact experiments were conducted to determine the high-pressure Hugoniot states for shocked SLG (37 to 120 GPa) and compared with recently reported results on FS. Using laser interferometry, particle velocity profiles were measured at the impact surface and the SLG/LiF window interface. In all experiments, the transmitted profiles show a single shock wave, with no features indicative of a phase transformation. The Hugoniot states determined from the wave profiles are described well using a linear shock velocity–particle velocity relation. Interferometry measurements (using 1550-nm wavelength laser) at the impact surface show that SLG is transparent when shocked to 55 GPa, transparent for tens of nanoseconds after impact between 55 and 81 GPa, and opaque beyond 81 GPa. From impact surface measurements, a linear relationship between the apparent and true particle velocity was observed, resulting in a linear relationship between the refractive index (at 1550 nm) and density. At 120 GPa, the SLG density is nearly twice its ambient value, indicating that SLG can achieve highly dense amorphous states. When compared to FS, shocked SLG is much less compressible and likely does not transform to a crystalline phase. A plausible explanation for this difference is indicated.

58 GEOSCIENCES↗

Experimental study of high-energy single-pulse nanosecond discharges in pin-to-pin configuration

Single-pulse pin-to-pin nanosecond pulsed discharges in ambient air (gap distances of 3–7 mm) were investigated at high pulse energies (∼20–30 mJ deposited energy per 11 ns full width at half maximum pulse). A Michelson interferometry setup (532 nm continuous-wave laser) was employed to record time-resolved interferograms of the discharge, enabling spatially resolved calculation of the electron number density. An intensified charge-coupled device camera was used to capture the spatiotemporal evolution of the discharge (streamer formation and spark channel development), and Coherent Anti-Stokes Raman Spectroscopy (CARS) was used to measure post-discharge N 2 vibrational temperatures. Discharge current and voltage were monitored with a back-current shunt. The discharge was initiated with simultaneous cathode-directed and anode-directed streamers that bridge the gap within ∼1 ns and form a luminous, filamentary plasma channel immediately after breakdown. Laser interferometry measurements showed peak electron number densities of the order of 10 1 7–10 18 cm −3 , occurring about 15–20 ns after pulse arrival at the discharge gap. Shorter gap discharges yielded higher peak electron densities, consistent with the higher energy density in the smaller gaps. Spatially, the electron density was highest near the electrodes and decreased toward the midgap region, with 5 and 7 mm gaps exhibiting a pronounced drop in the central channel. CARS indicated initial vibrational temperatures of approximately 4000–6000 K in the spark core of ∼50 ns after the discharge onset, decaying on a ∼500 ns timescale as the plasma cooled and recombined.

Coherent anti-Stokes Raman spectroscopy↗

Optimizing ablator thickness for laser shock experiments

In laser shock experiments, a well-defined, flat-top shock wave at the ablator/sample interface is important for accurately probing material response under uniaxial strain compression. However, the relationship between the ablator thickness and the resulting shock wave characteristics is insufficiently understood, limiting the ability to design optimal experiments. To address this need, we conducted a systematic experimental study using a 100 J laser to shock-compress polyimide ablators to peak stresses ranging from 20.4 to 111.6 GPa. Laser interferometry diagnostics measured the transmitted wave profiles at the ablator/sample interface, consistently showing a single jump followed by a constant peak state before the arrival of release waves. Here, by analyzing shock transit time, flat-top duration, and stress, our results establish a framework for selecting ablator thickness to maximize the flat-top duration, improving the precision and reproducibility of laser shock experiments.

design of experiments↗

Three-dimensional full-field velocity measurements in shock compression experiments using stereo digital image correlation

Shock compression plate impact experiments conventionally rely on point-wise velocimetry measurements based on laser-based interferometric techniques. This study presents an experimental methodology to measure the free surface full-field particle velocity in shock compression experiments using high-speed imaging and three-dimensional (3D) digital image correlation (DIC). The experimental setup has a temporal resolution of 100 ns with a spatial resolution varying from 90 to 200 μm/pixel. Experiments were conducted under three different plate impact configurations to measure spatially resolved free surface velocity and validate the experimental technique. First, a normal impact experiment was conducted on polycarbonate to measure the macroscopic full-field normal free surface velocity. Second, an isentropic compression experiment on Y-cut quartz–tungsten carbide assembly is performed to measure the particle velocity for experiments involving ramp compression waves. To explore the capability of the technique in multiaxial loading conditions, a pressure shear plate impact experiment was conducted to measure both the normal and transverse free surface velocities under combined normal and shear loading. The velocities measured in the experiments using digital image correlation are validated against previous data obtained from laser interferometry. Numerical simulations were also performed using established material models to compare and validate the experimental velocity profiles for these different impact configurations. The novel ability of the employed experimental setup to measure full-field free surface velocities with high spatial resolutions in shock compression experiments is demonstrated for the first time in this work.

47 OTHER INSTRUMENTATION↗

Sound speed measurements in lithium fluoride single crystals shock compressed to 168 GPa along [100]

The shock wave response of [100] lithium fluoride (LiF) single crystals at high stresses is of long-standing interest due to their extensive use as optical windows in dynamic compression experiments. The report of melting in shock compressed LiF single crystals between 134 GPa and 152 GPa – based on a single sound speed datum [J. Appl. Phys. 117, 045901 (2015)] – was surprising because good optical transmission was previously demonstrated in LiF shock compressed to ~200 GPa [J. Appl. Phys. 116, 033515 (2014)]. To address these apparent differences, we report on plate impact experiments on [100] LiF single crystals shock compressed to 168 GPa. Wave profiles were measured using laser interferometry to determine Hugoniot states and longitudinal sound speeds in shock compressed LiF. The measured Hugoniot states are in good agreement with those measured in previous studies. However, the measured sound speeds presented here show no evidence of melting up to 168 GPa. In particular, the abrupt drop reported previously in sound speed at 152 GPa was not observed in the present work. Furthermore, our results establish a lower bound of 168 GPa for the onset of melting in shock compressed LiF single crystals.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Peak states of molybdenum single crystals shock compressed to high stresses

In this work, to determine crystal anisotropy effects at high stresses, peak states behind the plastic shock waves were examined in BCC single crystals. Using plate impact experiments, molybdenum (Mo) single crystals were shock compressed up to 190 GPa elastic impact stress along [100], [110], and [111] orientations. Laser interferometry was used to measure wave velocities and particle velocity profiles at the Mo–LiF window interface. These data were analyzed to obtain in-material quantities in the peak states. The Hugoniots for [100] and [110] orientations were comparable, but the Hugoniot for the [111] orientation was different from the other two orientations. Also, these Mo single crystal Hugoniots display differences from the polycrystalline Mo Hugoniots. Although none of the differences can be considered large, the present results demonstrate that, unlike FCC metal single crystals (Cu, Al), some anisotropy is preserved in Mo single crystal Hugoniots even at high stresses.

36 MATERIALS SCIENCE↗

Sound speed measurements in shock-compressed cemented Tungsten carbides at pressures up to 100 GPa

To gain insights into thermodynamic states attained during shock compression of cemented tungsten carbide with 3.7 wt.% cobalt binder, we present results of longitudinal sound (release wave) speed measurements and their analysis at peak stresses up to 100 GPa (volumetric compression ratio ~ 15%). The sound speeds are determined using front-surface impact and release-wave overtake plate impact experimental configurations using laser interferometry. The measured sound speed data along with estimates for bulk sound speeds obtained using the fourth-order Birch-Murnaghan EoS and thermodynamics are used to determine the longitudinal moduli and shear moduli of shocked tungsten carbide at the various peak compression states attained in the experiments. Here, the longitudinal sound speeds were found to increase linearly with volume compression ratio from 6.97 ± 0.010 km/s at ambient conditions to 8.26 ± 0.156 km/s at a volume compression ratio of ~ 15%. The corresponding longitudinal elastic moduli also increase nearly linearly with the volume compression ratio but remain consistently lower than their theoretical predictions based on continuum models with no damage. Also, the sensitivity of shear moduli to pressure, as predicted by the Steinberg-Guinan model, is reduced substantially and the shear moduli of cemented WC with 3.7 wt.% Co remains nearly constant at ~ 310 GPa at the various peak compression stress states investigated in the present study.

36 MATERIALS SCIENCE↗