Laser interferometry and photon scattering in plasma diagnostics.
Laser interferometry and photon scattering in high temperature plasma diagnostics
SEARCH · Engineering Papers
Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.
Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.
Laser interferometry and photon scattering in high temperature plasma diagnostics
A high sensitivity laser interferometry for continuous monitoring of optical path changes is presented. The sensitivity to small changes in the optical path is achieved by means of a feedback system which keeps the interferometer at its maximum (and linear) position. Two experiments were designed to verify the interferometer's performance, both in direct and in scattering configurations. In each case, small temperature fluctuations were introduced as the signal source. Simultaneous measurement of temperature were compared with the results of the interferometer. Good correlation between the results were obtained. Finally, the application of the high sensitivity interferometer for detection of boundary-layer transition is examined. Optical signal strength and possible sources of noise are examined. Some methods of model surface preparation for enhancement of signal-to-noise ratio are discussed.
Using Mossbauer effect and laser interferometry to determine extremely small amplitudes for vibration measurements and calibration of scale models
Laser interferometer and heterodyne system for cesium plasma diagnostics
The laser interferometric skin friction meter was used to measure wall shear stress distributions in two interactions of fin-generated swept shock waves with turbulent boundary layers. The basic research configuration was an unswept sharp-leading-edge fin of variable angle mounted on a flatplate. The results indicate that such measurements are practical in high-speed interacting flows, and that a repeatability of + or - 6 percent or better is possible. Marked increases in wall shear were observed in both swept interactions tested.
Gravimeter permits more accurate and precise absolute measurement of g without reference to Potsdam values as absolute standards. Device is basically Michelson laser beam interferometer in which one arm is mass fitted with corner cube reflector.
The past decades have witnessed the development of new X-ray beam sources with brightness growing at a rate surpassing Moore’s law. Current and upcoming diffraction limited and fully coherent X-ray beam sources, including multi-bend achromat based synchrotron sources and high repetition rate X-ray free electron lasers, puts increasingly stringent requirements on stability and accuracy of X-ray optics systems. Parasitic motion errors at sub-micro radian scale in beam transport and beam conditioning optics can lead to significant loss of coherence and brightness delivered from source to experiment. To address this challenge, we incorporated optical metrology based on interferometric length and angle sensing and real-time correction as part of the X-ray optics motion control system. A prototype X-ray optics system was constructed following the optical layout of a tunable X-ray cavity. On-line interferometric metrology enabled dynamical feedback to a motion control system to track and compensate for motion errors. The system achieved sub-microradian scale performance, as multiple optical elements are synchronously and continuously adjusted. This first proof of principle measurement demonstrated both the potential and necessity of incorporating optical metrology as part of the motion control architecture for large scale X-ray optical systems such as monochromators, delay lines, and in particular, X-ray cavity systems to enable the next generation cavity-based X-ray free electron lasers.
Understanding quantum gravity remains one of the deepest challenges in modern physics, as direct experimental access to Planck-scale effects is beyond current technological reach. However, recent theoretical advances indicate that quantum fluctuations of spacetime may produce measurable effects in precision experiments, particularly near causal horizons. This opens new avenues for testing quantum gravity phenomena through high-precision measurement techniques. This dissertation develops multiple theoretical models to characterize these effects and examines their potential observational signatures in future gravitational wave interferometers. We begin by investigating the role of quantum fluctuations in near-horizon geometries through the lens of the AdS/CFT correspondence, which provides a powerful framework for understanding the interplay between quantum field theory and general relativity via holographic principles. By modeling stochastic energy-momentum sources in Rindler-AdS spacetime, we demonstrate that vacuum fluctuations transform the Einstein equations into a Langevin-type stochastic differential equation, leading to potentially observable fluctuations in photon traversal times. Extending this approach to Minkowski spacetime, we establish a correspondence between gravitational shockwaves and fluid dynamics, showing that near-horizon perturbations satisfy an equation analogous to that governing incompressible fluids, thereby reinforcing the membrane paradigm and hydrodynamic analogies in the context of the fluid/gravity duality. Furthermore, we construct the covariant phase space of a spherically symmetric causal diamond in Minkowski spacetime, identifying two fundamental charges that govern its evolution. These results provide a foundation for quantizing causal horizons and understanding their microscopic degrees of freedom. Building upon these theoretical developments, we further examine a related stochastic phenomenon: the gravitational wave memory background arising from the cumulative memory steps produced by supermassive black hole mergers. After reviewing the standard stochastic gravitational wave background, gravitational memory effects, and BMS symmetries, we model the stochastic memory background using a Brownian motion framework. We show that while the cumulative memory background initially appears above the sensitivity curve of space-based interferometers like LISA, the realistic subtraction of individually resolvable merger events substantially suppresses the residual signal, making its detection more challenging. This highlights the critical importance of source subtraction when evaluating the detectability of gravitational memory effects. By bridging fundamental theory with experimental prospects, this dissertation contributes to the ongoing effort to uncover the quantum nature of spacetime through precision measurement techniques. Whether through detecting quantum spacetime fluctuations, gravitational memory backgrounds, or probing the symmetries of causal horizons, the pursuit of observable quantum gravity phenomena continues to expand the frontiers of both theory and experiment.
A modification of focused laser differential interferometry (FLDI) is demonstrated with an infrared tunable diode laser (TDL) to achieve simultaneous absorption spectroscopy (AS) measurements. Measurements from this absorbing-FLDI (A-FLDI) are shown for a Hencken burner plume. Initial comparison measurements are recorded using TDLAS and an electrical hygrometer. Raw voltage and estimated absorbance measurements illustrate that the technique detects five distinct absorbance peaks of the methane–air flame while retaining the expected behavior of typical FLDI. This modification furthers efforts to enable FLDI to conduct analysis of the pressures, temperatures, and molecular densities of flows. It also explores the potential for reducing path-integration (PI) effects in absorption spectroscopy and potentially enabling spatially and temporally resolved local flow measurements. Reductions in PI length as high as 82%–84% are observed.
Practical aspects of using laser holographic interferometry in some NASA Ames wind tunnels are presented. These aspects include the development of techniques for dual-plate interferometry, optics alignment, and laser alignment. In addition, methods to alleviate problems associated with vibration, photographic processing, photographic drying, and photographic reconstruction are discussed.
Practical aspects of using laser holographic interferometry in some NASA Ames wind tunnels are presented. These aspects include the development of techniques for dual-plate interferometry, optics alignment, and laser alignment. In addition, methods to alleviate problems associated with vibration, photographic processing, photographic drying, and photographic reconstruction are discussed.
Laser holographic interferometry was used to study a two-dimensional NACA 0012 airfoil undergoing dynamic stall. The airfoil, fabricated from graphite fiber and epoxy, was tested at Mach numbers of 0.3 to 0.6, at Reynolds numbers of 500,000-2,000,000, at reduced frequencies of 0.015 to 0.15, and at mean angles of attack of 0-10 deg with amplitudes of 10 deg. Density and pressure fields were obtained from dual-plate interferograms. Double-pulse interferograms, which seemed to show the wake boundaries better, were also taken. Comparisons of pressures with orifice pressures were good for the attached flow cases. For the separated flow cases, which had a vortex enbedded in the flow, the comparisons were poor. Vortices, wake structures, and the dynamic stall process can be seen by holographic interferometry.
Research was conducted on a laser light scatter detection method for measuring the size and velocity of spherical particles. The method is based upon the measurement of the interference fringe pattern produced by spheres passing through the intersection of two laser beams. A theoretical analysis of the method was carried out using the geometrical optics theory. Experimental verification of the theory was obtained by using monodisperse droplet streams. Several optical configurations were tested to identify all of the parametric effects upon the size measurements. Both off-axis forward and backscatter light detection were utilized. Simulated spray environments and fuel spray nozzles were used in the evaluation of the method. The measurements of the monodisperse drops showed complete agreement with the theoretical predictions. The method was demonstrated to be independent of the beam intensity and extinction resulting from the surrounding drops. Signal processing concepts were considered and a method was selected for development.
Recent developments in thermoplastic recording holograms and advancements in automated image digitalization and analysis make real-time laser holographic interferometry feasible for two-dimensional flows such as airfoil flows. Typical airfoil measurements would include airfoil presssure distributions, wake and boundary layer profiles, and flow field density contours. This paper addresses some of the problems and requirements of a real-time laser holographic interferometer.
Recent developments in thermoplastic recording holograms and advancements in automated image digitalization and analysis make real-time laser holographic interferometry feasible for two-dimensional flows such as airfoil flows. Typical airfoil measurements would include airfoil pressure distributions, wake and boundary layer profiles, and flow field density contours. This paper addresses some of the problems and requirements of a real-time laser holographic interferometer.
We present an explicitly gauge-invariant observable of any general gravitational perturbation, ℎ 𝜇𝜈 [not necessarily due to gravitational waves (GWs)], in a laser interferometry-based GW detector, identifying the signature as the proper time elapsed of the beamsplitter observer, between two events: when a photon passes through the beamsplitter, and when the same photon returns to the beamsplitter after traveling through the interferometer arm and reflecting off the far mirror. Our formalism applies to simple Michelson interferometers and can be generalized to more advanced setups. We demonstrate that the proper time observable for a plane GW is equivalent to the detector strain commonly used by the GW community, though now the common framework can be easily generalized for other types of signals, such as dark matter clumps or spacetime fluctuations from quantum gravity. We provide a simple recipe for computing the proper time observable for a general metric perturbation in linearized gravity and explicitly show that it is invariant under diffeomorphisms of the perturbation, as any physical observable should be.
Report on measurements of maximum exothermic power pulses attainable from a given chemical system. Experimental tests involved the use of a shock tube technique whereby the exothermic process of combustion was controlled by reflected shock, so that it occurred under virtually inviscid flow conditions, while the measurements were performed at a resolution commensurate with the actual rate of chemical reaction. Experimental observations were made by means of a novel method of laser shear interferometry - a cross-breed between holography and the conventional means for measuring refractive index fields, in that, on one hand, it was based on the exploitation of the phase coherence of the laser light beam, recording first a diffraction image of the wave fronts which, for the desired final result, had to be optically reconstructed, and, on the other, it yielded eventually either two-dimensional interferograms or schlieren photographs of the observed phenomena.
The paper reports on the measurements of maximum exothermic power pulses attainable from a given chemical system. Experimental tests involved the use of a shock tube technique whereby the exothermic process of combustion was controlled by reflected shock so that it occurred under virtually inviscid flow conditions, the data having been obtained at a resolution commensurate with the actual rate of chemical reaction. Experimental observations were made by means of a novel method of laser shear interferometry. Chemical systems treated in this manner comprised of mixtures of stoichiometric hydrogen-oxygen with 80 and 90% argon, while the measurements covered the full permissible range of initial thermodynamic conditions.