Identification of Voltage Stability Critical Locations for Future Large Grids With High Renewable Mix
Not Available
SEARCH · Engineering Papers
Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.
Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.
Not Available
Not Available
The purpose of this project is to understand dynamic phenomena by designing dynamic models of utility-sale solar photovoltaic (PV) power plants and their interactions with grids; and construct effective coordination strategies for stability enhancement for solar PVs to respond to rapidly changing grid conditions.
The escalating integration of inverter-based resources (IBRs) poses new challenges to power systems by introducing fast dynamics with higher frequencies, which may need to be simulated by an electromagnetic transient (EMT) program. As an alternative to conducting EMT simulations for the entire system, which is typically time consuming, hybrid simulation between EMT and phasor-domain transient stability (TS) can greatly reduce the computational burden while preserving the detailed fast dynamics in the EMT zone. This paper establishes an EMT-TS hybrid simulation platform using open-source tools, specifically ParaEMT, GridPACK, and HELICS, which are the EMT simulator, TS simulator, and interface framework, respectively. Case studies on the 240-bus Western Electricity Coordinating Council (WECC) system demonstrate that the developed ParaEMT-HELICS-GridPACK hybrid simulator can accurately capture both slow electromechanical and fast IBR-driven dynamics with a 2.4x speedup.
The capacity and generation of wind, solar, storage, nuclear, and gas are estimated for large, idealized copper-plate electric grids. Wind and solar penetrations of 30% to 80% are considered together with different storage systems such as vanadium and lithium-ion batteries, pumped hydroelectric, compressed air, and hydrogen. In addition to a baseline dispatchable fleet without wind/solar, two bounding cases with wind/solar are analyzed: one without storage and one where the whole wind/solar fleet is connected to the storage system, hence providing a buffer between the wind/solar fleet and the grid. The reality will likely be somewhere between these bounding cases. The viability of a power grid with a large wind/solar penetration and no storage is not guaranteed but was nonetheless considered to provide a lower-bound capital cost estimate. Overall, the options that rely strongly on wind, solar, and storage could be significantly more capital-intensive than those that rely strongly on nuclear, depending on the amount of storage necessary to ensure grid stability. This is especially true in the long run because wind, solar, and storage assets have shorter lifetimes than nuclear plants and, consequently, need to be replaced more frequently. More analyses (e.g., grid stability and public acceptance) are necessary to determine which option is most likely to provide the path of least resistance to powering a clean, affordable, and reliable grid in a timely manner. Depending on the priorities, the path of least resistance may not necessarily be the one that is less capital intensive.
Many important physical processes in inertial confinement fusion (ICF) and dense Z-pinch (DZP) experiments require a kinetic (velocity-space-dependent) description. Conventional particle-in-cell (PIC) methods are poorly suited for high-energy-density (HED) plasmas, due to restrictive time-step constraints and the inability to conserve energy. In a previous LDRD (21-FS-048), we demonstrated that a fully implicit PIC formulation overcomes these limitations: it conserves energy even when coupled with Coulomb collision models and can be solved efficiently with large grid cells and large time steps. Thus, it is feasible to use this method to study kinetic effects in ICF and DZP plasmas on hydro-like time and spatial scales. In this follow-on LDRD, we advanced this methodology into a high-fidelity tool for production-scale simulations and used it to answer key questions relevant to ICF and DZP experiment.
Recent measurements have reported non-Gaussian tails in the distribution of frequency data in electric power grids. Large frequency deviations may induce grid instabilities and it is therefore crucial to understand how noise disturbances with long, non-Gaussian tails propagate. Here, we investigate how fluctuations in power feed-in, characterized by non-zero cumulants of their distribution, propagate through high-voltage power grids. Unlike previous investigations which focused on the white-noise limit, we consider the limit of long noise correlation time, where power feed-in fluctuates over times longer than the inherent dynamical time scales of the grid - the relevant regime for large-scale, high-voltage distribution grids. In this work, we show that in this limit, the skewness and kurtosis of the power feed-in distribution propagate similarly as its variance, independently of the distribution of inertia. Non-Gaussianities from individual sources of noise therefore persist throughout the entire network. This finding is corroborated by numerical results on a realistic model of the synchronous grid of continental Europe.
We present a substantial update to the MESA Isochrones and Stellar Tracks (MIST) library, extending the MIST model grids and isochrones down the white dwarf (WD) cooling sequence with realistic physics for WD cooling timescales. This work provides a large grid of MESA models for carbon–oxygen core WDs with hydrogen atmospheres (spectral type DA/DC), descended from full prior stellar evolution calculations. The model tracks, isochrones, and WD cooling timescale contours are available on the MIST project website and at doi:10.5281/zenodo.15242047. Our WD models provide a very large, publicly available grid with detailed physics for WD cooling timescales: realistic interior and envelope compositions, with element diffusion and heavy-element sedimentation, nuclear burning at the base of the WD hydrogen envelope, core crystallization, and C/O phase separation. As a large grid of open-source stellar evolution models, these WD models provide both out-of-the-box model tracks for comparison with observations and a framework for building further WD models to investigate variations in WD physics.
Not provided.
In the past decade, natural disasters such as hurricanes have challenged the operation and control of U.S. power grid more. It is crucial to develop proactive strategies to assist grid operators for better emergency response and minimized electricity service interruptions. In this paper, we propose a proactive posturing methodology of power system elements, and formulated a Security-Constrained Optimal Power Flow (SCOPF) that informed by cross-domain hurricane modeling and its potential impacts on the grid elements. Simulation results based on real-world power grid and historical hurricane event validated the applicability of the proposed optimization formulation, and show potential to enable grid operators and planners with interactive cross-domain data analytics in mitigating hurricane impacts.
The wide-area measurement system (WAMS) is a key enabler of real-time monitoring of power grids. The essential goals of WAMS design are fast and resilient data transfer from phasor measurement units (PMU) to phasor data concentrators (PDC). We propose a scalable two-stage PDC placement technique for minimizing the end-to-end delay while maintaining resiliency. In the prescreening stage, the plausible candidates of PDC configurations are identified based on a graph theory-based multi-median function (MMF). Here, in this article, a computationally efficient meta-heuristic algorithm is used to address scalability. In the candidate selection stage, two different algorithms, namely, Suurballe's and Dijkstra's, are employed to identify the best of those plausible PDC configurations as the final design. This technique not only minimizes the hop paths between PMUs and PDCs, but also ensures network resiliency against single PMU, PDC, or communication link failure by incorporating the roles of PMUs in power grid observability into routing policy. Simulation results on the IEEE 57-bus test power system and the 2000-bus test power system demonstrate the effectiveness and scalability of the proposed technique.
Geomagnetic-induced current (GIC) flow in power grids can cause undesirable effects such as transformer overheating, harmonics, higher reactive power demand, etc. Many simulation models have been developed to study these effects, but real-world verification on modern transformer designs is rare. Here, this paper presents the first long-duration GIC field test in the U.S. performed on high-voltage, grid-connected transformers featuring winding clamps and tie rods instead of conventional tie bars. Field measurements were taken to evaluate GIC effects. These measurements also aided in developing and validating thermal and electromagnetic transient (EMT) models of the transformers. During the test, significant current and voltage distortions were observed along with considerable transformer reactive power losses. Analysis of the field measurements showed that the transformers’ hottest spot was at the inner windings, and their k-factors were close to factory test and software default values. Thermal simulations indicated that the transformers would not violate their thermal limits even for a GIC waveform that peaks at about 200 A/phase. EMT simulations revealed that increased transformer loading may reduce GIC-induced reactive power demand and harmonics in certain scenarios. The study also highlighted potential inaccuracies in using the k-factor method to calculate transformer reactive power losses.
Causal discovery algorithms construct hypothesized causal graphs that depict causal dependencies among variables in observational data. While powerful, the accuracy of these algorithms is highly sensitive to the underlying dynamics of the system in ways that have not been fully characterized in the literature. In this report, we benchmark the PCMCI causal discovery algorithm in its application to gridded spatiotemporal systems. Effectively computing grid-level causal graphs on large grids will enable analysis of the causal impacts of transient and mobile spatial phenomena in large systems, such as the Earth’s climate. We evaluate the performance of PCMCI with a set of structural causal models, using simulated spatial vector autoregressive processes in one- and two-dimensions. We develop computational and analytical tools for characterizing these processes and their associated causal graphs. Our findings suggest that direct application of PCMCI is not suitable for the analysis of dynamical spatiotemporal gridded systems, such as climatological data, without significant preprocessing and downscaling of the data. PCMCI requires unrealistic sample sizes to achieve acceptable performance on even modestly sized problems and suffers from a notable curse of dimensionality. This work suggests that, even under generous structural assumptions, significant additional algorithmic improvements are needed before causal discovery algorithms can be reliably applied to grid-level outputs of earth system models.
While the majority of electric vehicle (EV) charging events in the United States occur at home, issues with public charging stations are consistently found to be a top reason that potential EV buyers do not purchase an EV, demonstrating that both EVSE reliability and availability impacts EV adoption. This report explores multiple parameters that impact EVSE reliability and deployment, which in turn impact EV sales. These include extreme weather, codes and standards, region (urban vs. rural), and grid network type. Grid reliability was not found to impact EV adoption. The relationships between EV station reliability, station resilience, grid resilience, and EV adoption are largely outside the scope of the National Renewable Energy Laboratory's (NREL's) Automotive Deployment Options Projection Tool (ADOPT) and other vehicle adoption models, so the methodology of this report is varied. Section 2 sets the baseline for infrastructure reliability, user satisfaction, and maintenance practices. Section 3 explores the ways that electric vehicle supply equipment (EVSE) reliability impacts the relationship between EVSE and EV adoption. Section 4 shows how geographical categories such as urban, rural, large grid, off-grid, or microgrid can be helpful in EVSE deployment strategies, as well as how the relationship between EVSE and EV adoption differs among these categories. Section 5 investigates the impacts of grid reliability and infrastructure resilience on EV adoption. Finally, Section 6 reverses the perspective to examine the impact that EVs and EVSE have on grid resilience and reliability. As recent funding initiatives result in an expansion of public chargers across the United States, as well as an increase in the uptime of existing chargers, EV adoption will likely grow.
Grid-forming (GFM) control of Type-3 and Type-4 wind turbine generators (WTGs) has attracted substantial attention in power systems research; however, the limited overcurrent capability of power electronics converters continues to deteriorate the grid strength of the evolving power systems. Synchronous wind, also known as a Type-5 WTG, offers a unique GFM solution to address grid integration and grid strength issues by keeping the grid largely synchronous at very high integration levels of renewable generation. A Type-5 WTG interfaces with the electric grid via a synchronous generator driven by a variable-speed hydraulic torque converter; hence, the wind rotor operates in variable-speed mode for maximum power generation, and the generator shaft remains synchronous to the grid. This paper develops and tests a high-fidelity model of a Type-5 WTG in a power-hardware-in-the-loop (PHIL) testing environment. The PHIL demonstration shows that a Type-5 WTG inherently behaves as a GFM unit and can obtain similar performance in terms of power responses, wind rotor dynamics, and efficiency compared to a Type-3 WTG in high-wind conditions. The developed model provides further insight into how Type-5 WTGs can benefit the smooth transition to power systems with high integration levels of inverter-based resources.
Grid-forming (GFM) control of Type 3 and Type 4 wind turbine generators (WTGs) has attracted substantial attention in power systems research; however, the limited overcurrent capability of power electronics converters continues to deteriorate the grid strength of the evolving power systems. Synchronous wind, also referred to as a Type 5 WTG, offers a unique GFM solution to address grid integration and grid strength issues by keeping the grid largely synchronous at very high integration levels of renewable generation. A Type 5 WTG interfaces with the electric grid via a synchronous generator driven by a variable speed hydraulic torque converter; hence, the wind rotor operates in variable-speed mode for maximum power generation, and the generator shaft remains synchronous to the grid. This paper develops and tests a high-fidelity model of a Type 5 WTG in a power-hardware-in-the-loop testing environment, and it presents its operation characteristics under different grid contingencies. The power-hardware-in-the-loop demonstration shows that a Type 5 WTG inherently behaves as a GFM unit and can obtain similar performance in terms of power response, wind rotor dynamics, and stability enhancement compared to a Type 3 WTG in GFM control mode. Furthermore, the paper provides further insight into how Type 5 WTGs can support the smooth transition to power systems with high integration levels of inverter-based resources.
Grid-forming (GFM) control of Type-3 and Type-4 wind turbine generators has attracted substantial attention in power systems research; however, the limited over-current capability of power electronics converters continues to deteriorate the grid strength of the evolving power systems. Synchronous wind, also known as Type-5 wind turbine generator (WTG), offers a unique GFM solution to address grid integration and grid strength issues by keeping the grid largely synchronous at very high penetration levels of renewable generation. A Type-5 WTG interfaces to the electric grid via a synchronous generator (SG) driven by a variable-speed hydraulic torque converter; hence, the wind rotor operates in variable-speed mode for maximum power generation and the generator shaft remains synchronous to the grid. This paper developed and tested a high-fidelity model of Type-5 WTG under power-hardware-in-the-loop (PHIL) testing environment. The PHIL demonstration showed that a Type-5 WTGs inherently behaves as a GFM unit and can obtain similar performance in terms of power responses, wind rotor dynamics, and efficiency compared to Type-3 WTG in high wind conditions. The developed model also provides further insight on how Type-5 WTGs can benefit the smooth transition to power systems with high integration level of inverter-based resources.
Climate change and anthropogenically-forced shift of weather in the future will impact energy use and resilience of both the built environment and the electric grid. The aim of this analysis is to understand how future climate scenarios will impact electricity and natural gas use of commercial buildings in the United States. Here, this study analyzes this impact for 2030, 2045, and 2100 using Representative Concentration Pathways (RCP) scenarios defined in Intergovernmental Panel on Climate Change (IPCC) Assessment Report 5. The large, gridded simulation of meteorological variables for RCPs 2.6, 4.5, 6.0, and 8.5 are selected and downscaled to make available hourly Future Meteorological Year (FMY) weather files for use and improvement in subsequent studies. High performance computing resources use these FMYs to simulate commercial prototype buildings in every American Society of Heating, Refrigeration, and Air Conditioning Engineers (ASHRAE) climate zone of the United States (US), and results are scaled to nation-wide energy use using conditioned floor area multipliers. The analysis is conducted without speculating the physical and performance traits of future buildings or the grid characteristics. This analysis quantifies the impact of climate change on source electrical and natural gas usage for commercial buildings in the United States over the next 80 years. If US commercial floorspace remained constant, total energy use by 2100 is predicted between an 1.75% decrease under the greatest emission scenario (8.5) and a 1.76% increase under the lowest emission scenario (2.6). When adjusted for anticipated urban growth by 2100, the predicted range is 65% increase (8.5) and 71% increase (2.6). Under a global temperature rise climate scenario, the warmest US climate zones will see a large increases in electricity use derived from space cooling while the coldest US climate zones will see significant decreases in natural gas use caused by the decrease in heating necessary. While climate change may ultimately require adaptations of the built environment to withstand its effects and because the United States is a country that requires more heating than cooling, from a building energy perspective, climate change (average temperature rise) is a net energy saver for the United States.