Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “jacket damage”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

Surface Wave Based Non-conductor-contact Reflectometry Method for Insulation and Jacket Damage Detection in Multi-Conductor Cables

This paper presents a non-conductor-contact surface wave reflectometry technique to locate insulation and jacket damage on multi-conductor cables at a distant location from the sensor. Simulation studies were conducted using Ansys high frequency structure simulator (HFSS). A GHz range surface wave launcher was employed such that maximum surface wave energies were confined in the insulation layer while minimizing attenuation. The wave launcher can potentially be mounted on the outer surface of live cables or cable conduits and requires no physical connection to the conductors. Multiple simulations involving a 4 GHz wave launcher and a three-conductor cable with an 8 mm outer diameter were carried out demonstrating the efficacy of the proposed method. Water leak and different types of insulation/jacket damage were simulated and detected.

reflectometry, multi-conductor cable, frequency do↗

Miniature Crack or Damage Detection on Cable Insulation and Jacket Using Conformal Surface Wave Reflectometry

This letter introduces the study and application of a conformal surface wave launcher array to detect miniature insulation and/or jacket damage on unshielded cables. Here simulation and experimental results are presented that demonstrate that with the proposed concept very small instances of damage at various distances along power cables can be detected. Effects of damage detection feasibility in the presence of other cables in proximity and for cables containing semiconducting screen are also presented.

42 ENGINEERING↗

Non-Conductor-Contact Surface Wave Reflectometry for Cable Insulation Damage Detection

Here, this paper presents a non-conductor-contact surface wave-based reflectometry technique to detect and locate missing or damaged insulation and/or jacket of electrical cables. The described sensor may be uniquely and practically implemented on live cables as a non-destructive evaluation (NDE) method since it may be applied to the outer insulation/jacket of a cable and requires no direct contact to the conductor. The innovation lies in a high-frequency surface wave launcher that can introduce broadband signals in the GHz frequencies that insure maximum electromagnetic (EM) energy localization within the insulation and/or jacket material. By further processing the reflection data in the frequency domain, the location and severity of insulation damage is detected. Simulated results of thin, thick, short, and long cables show the results expected from small, medium, and large damage regions. For example, the detection of 40 mm-long damage region at 40 m distance on a 50 m long cable (2.44 cm diameter) is demonstrated. Experimental results are presented that validate simulation findings.

Non Destructive Evaluation↗

Advanced Diagnosis and Accelerated Testing of Balance of System Components for Utility Scale PV Installations: October 1, 2022-September 30, 2024

A study of the durability of PV Balance of System components was performed. Specifically, wire cable jackets and cable connectors were examined within the direct current (DC) PV Power Transmission Chain (PTC). Degraded and failed samples have been obtained from utility PV installations to provide feedback on the degradation modes and the related damage-enabling considerations in today's PV systems. An industry interface group (including system owners, system inspectors, component manufacturers, and test labs) was used to help identify and obtain field-failed samples, for feedback (including samples and experimental design), and to facilitate the subsequent dissemination of the results of this study. Samples were empirically studied using accelerated stress testing with steady-state conditions (cable jackets) in addition to combined-accelerated stress testing (cable jackets, connectors and uncapped connectors). Steady-state accelerated testing has been performed using at least one applied stressor (e.g. UV light) to aid understanding of jacket durability relative to its application. Component- and material-focused failure analysis was conducted to develop an understanding and advise the PV industry. In-depth characterization will be applied selectively to field- and artificially aged-samples, to gain scientific understanding of the structural, chemical, electrical, mechanical, and thermal properties enabling degradation.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Accelerated Aging of PV Cables - The Development of Methods Towards Combined-Accelerated Stress Testing

PV cables allow the collection and distribution of electricity from modules to the energy grid. Durable cabling allows continuous operation of PV installations. Cables with a life less than that of the modules must be replaced - reducing electricity generation and adding to the system operating expense. We have examined the durability of a variety of representative cable samples using artificial UV weathering (IEC TS 62788-7-2) and combined accelerated stress testing (C-AST). Jackets in this study include PV-rated (polyolefin), building wire (PVC/PA), and multi-conductor (rubber, as in PV trackers), with some examples of black and red cables. Characterizations at read points include appearance (camera and optical microscope), surface roughness (linear profilometry), instrumented indentation, surface morphology (SEM), chemical composition (EDS), thermal decomposition (TGA), phase transition (DSC), crystalline structure (WAXS), and polymer chemical structure (FTIR). Complimentary examinations confirm damage to the external and interior layer(s) of less durable samples, including changes in morphology (e.g., cracking), chemistry (e.g., oxidation), structure, and mechanical performance (e.g., through-thickness modulus and hardness). The results may be generally compared to other examples from the field (PV installations) or after accelerated testing (IEC 61215). The methods in this study are presently being applied in a follow-on C-AST study, incorporating both dynamic and kinematic fixtures.

balance of systems↗

HEAF Cable Fragility Testing at the Solar Furnace at the NSTTF

In order to establish a zone of influence (ZOI) due to a high energy arcing fault (HEAF) environment, the fragility of the targets must be determined. The high heat flux/short duration exposure of a HEAF is considerably different than that of a traditional hydrocarbon fire, which previous research has addressed. The previous failure metrics (e.g., internal jacket temperature of a cable exposed to a fire) were based on low heat flux/long duration exposures. Because of this, evaluation of different physics and failure modes was considered to evaluate the fragility of cables exposed to a HEAF. Tests on cable targets were performed at high heat flux/short duration exposures to gain insight on the relevant physics and failure modes. These tests yielded data on several relevant failure modes, including electrical failure and sustained ignition. Additionally, the results indicated a relationship between the total energy of exposure and the damage state of the cable target. This data can be used to inform the fragility of the targets.

42 ENGINEERING↗

Risk Importance Ranking of Fire Data Parameters to Enhance Fire PRA Model Realism

Fire is historically and analytically a significant contributor to nuclear power plant risk. The level of fire risk and the methods, tools and data for modeling this risk is highly debated by experts. One area of debate is the input data used in fire modeling and how to deal with this data’s high uncertainty. This report outlines initial work performed for determining the key parameters causing this uncertainty and how it propagates into nuclear power plant models. This research paves the way for the development of methods to reduce fire data uncertainty used in modeling. The Nuclear Regulatory Commission has mandated that nuclear power plants perform fire risk modeling. However, there are several issues with the current risk modeling implementation that affect the results. Approved modeling methods can be overly conservative and often do not match plant experience. Also, the data used in the modeling can have high uncertainties and is influenced by expert judgement. To evaluate input data uncertainty, researchers performed an initial review of several fire experiments done at Sandia National Laboratories. Uncertainties for fire data can come from many sources, such as experiment design constraints, environmental conditions, or other plant-specific aspects. There are many different significant and insignificant parameters driving the uncertainty. Additionally, the uncertainty of the different input data used in the fire modeling could have a significant or insignificant effect on the entire plant risk. A four-step methodology was developed to perform Integrated Probabilistic Risk Assessment Importance Ranking. A demonstration case using these steps was set up and three of the four steps were completed in fiscal year (FY) 2019 and the fourth step done FY 2020. These steps are: 1. The qualitative analysis of potential sources was conducted with the following items identified for the demonstration. • Maximum heat release rate • Time to maximum heat release rate • Duration of max heat release rate • Time to decay • Thermal conductivity of concrete • Specific heat of concrete • Density of concrete • Cable jacket thickness 2. A quantitative characterization of dominant sources of uncertainty was performed. A list of distributions and determined values of the dominant sources is shown in Appendix A. 3. A quantitative screening of the potential sources of uncertainty using Morris Elementary Effects Analysis was completed. An experimental model using the physics-based fire modeling tool Fire Dynamics Simulator was developed and coupled with the Risk Analysis Virtual Environment. The Morris analysis identified at least two parameters that can be eliminated as significant contributors (specific heat of concrete and cable jacket thickness). 4. Global importance measure (Global IM) analysis to generate a comprehensive ranking based on their influence on the plant risk. In this research, a moment-independent Global IM is used since it can address (a) uncertainty in the input parameters of the fire model, (b) uncertainty in the risk outputs, and (c) non-linearity and interactions among input parameters in the fire model, more accurately than the correlation-based and variance-based global methods. The observations from the research showed that, depending on the initial and boundary conditions of the fire scenarios, fire-induced damage could have a very small probability and could be dominated by the tail of the uncertainty distribution; hence, the accuracy of the correlation-based and variance-based methods is questionable. The moment-independent Global IM analysis in this research provides a better understanding of how experimental uncertainty data affects industry’s plant models and where improvements in that data will have the largest benefit for improving fire modeling accuracy in causing core damage. Among the five unscreened parameters obtained from the Morris EE analysis, the Global IM analysis results for the case study indicated that max heat release rate and fire location are the most important parameters. The report also outlines benefits of using a unified computational platform that integrates the underlying simulations (e.g., a fire progression model), quantitative screening (using the Morris EE method), and the Global IM analysis. A unified platform can (i) facilitate the ranking of input parameters considering multiple key fire scenarios simultaneously, rather than considering one scenario at a time, (ii) contribute to more explicit and accurate treatment of dependencies at multiple levels of Fire PRA, (iii) facilitate the sampling-based uncertainty quantification for Fire PRA, and (iv) help generating both “industry-wide” and "plant-specific" ranking of uncertainty sources in Fire PRA. Future research should be done to include additional parameters such as detection/suppression or cable fire spread. Adding a PRA software such as SAPHIRE to the RAVEN platform would help with plant model integration and improve treatment of fire-induced dependency. The I-PRA risk importance ranking methodology offered in this report can provide valuable information for efficiently (a) enhancing the realism of Fire PRA for existing plants and (b) supporting the development of Dynamic Fire PRA for advanced reactors and new plants.

97 MATHEMATICS AND COMPUTING↗

Evolution of Permeability in Sandstone During Confined Brazilian Testing

Permeability measurements were made on sandstone during confined Brazilian strength tests. The test involves 50 mm diameter disk-shaped, jacketed samples that are subjected to confining stresses while they are diametrically loaded. Specially designed end caps allow for concurrent gas flow measurements. The test configuration allows for the samples to be subjected to a range of stresses, with the confining stress as the intermediate principal stress. Furthermore, the majority of the tests measured permeability during loading to failure in the confined extension region. The permeability of the sandstone sample increases significantly well before the peak load is reached due to newly formed microcracks that continue to coalesce and dilate with further loading. Permeability increases are inversely proportional to the intermediate principal stress as increased confining pressures suppress growth, coalescence, and dilation of microcracks. Additional testing includes unloading and reloading cycles prior to failure. With each unloading–reloading cycle, permeability at comparable stresses is increased compared to the previous cycle, consistent with increasing damage in the form of an expanding microcrack network.

58 GEOSCIENCES↗

Frequency Domain Reflectometry (FDR) Simulation Techniques for Digital Twin Representation of an Electrical Cable

Simulation of cable system response to frequency domain reflectometry (FDR) tests can be instrumental to understanding these tests and the nature and influence of various cable anomalies on test signatures. Reflectometry simulations are based upon a finite element representation of cable conductors and insulation to produce an S-parameter at each evaluated frequency. The aggregate collection of cable model S-parameters can simulate the influence on a test signal injected into a physical cable. Such an approach was undertaken in this work to produce a digital twin simulation of a low-voltage electrical cable. The electrical cable digital twin examined the influence of test simulation parameters and the relative influence of cable anomalies, including thermal aging, water or moisture exposure, water or moisture ingress, and other anomalies. The digital twin in this work included modeling of the conductors, insulation, jacket, and surrounding environment (air, water, etc.). The digital twin could be expanded to include cable bends, junctions and splices, branch or T systems, and termination impedances of motors or instruments. Observations and conclusions of this work include: 1. Fully 3D digital twin simulation of an electrical cable using an FDR approach is possible. However, there are tradeoffs between simulation fidelity and solution time, which must be balanced to ensure the simulation solves in an adequate amount of time (e.g., less than 20 minutes). Simulation parameters to balance include frequency bandwidth, number of frequencies, mesh density, connection impedance, and permittivity tolerance. 2. The digital twin simulation can explain FDR sensitivity to various cable anomalies, including entry and exit from an oven or water bath. 3. The digital twin simulation FDR response attenuates with distance along the cable and is further affected by the frequency bandwidth, which is similar to that observed with physical measurements. 4. The resolution of the digital twin FDR peaks increased with increasing bandwidth and with increasing number of frequencies, again similar to physical measurements. 5. The presence of multiple anomalies in the digital twin does not substantially attenuate the FDR response to anomalies located beyond the first encountered anomaly and impedance mismatch. 6. Spectral variation of the permittivity did not have a significant effect on the FDR response compared to a fixed nominal value. 7. Extension of the digital twin to 1000 ft still allowed for detection of distal anomalies near the far end of the electrical cable from the instrument connection point. 8. The ARENA test bed facilitates efficient NDE evaluations of well understood cable anomalies with various NDE methods without risking actual plant damage.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗