Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “ion mobility spectrometry”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Evaluation of a Reference-Free Collision Cross Section Calibration Strategy for Proteomics Using SLIM-Based High-Resolution Ion Mobility Spectrometry–Mass Spectrometry

Ion mobility spectrometry (IMS) is a gas-phase analytical technique that separates ions with different sizes and shapes and is compatible with mass spectrometry (MS) to provide an additional separation dimension. The rapid nature of the IMS separation combined with the high sensitivity of MS-based detection and the ability to derive structural information on analytes in the form of the property collision cross section (CCS) makes IMS particularly well-suited for characterizing complex samples in -omics applications. In such applications, the quality of CCS from IMS measurements is critical to confident annotation of the detected components in the complex -omics samples. However, most IMS instrumentation in mainstream use requires calibration to calculate CCS from measured arrival times, with the most notable exception being drift tube IMS measurements using multifield methods. The strategy for calibrating CCS values, particularly selection of appropriate calibrants, has important implications for CCS accuracy, reproducibility, and transferability between laboratories. The conventional approach to CCS calibration involves explicitly defining calibrants ahead of data acquisition and crucially relies upon availability of reference CCS values. In this work, we present a novel reference-free approach to CCS calibration which leverages trends among putatively identified features and computational CCS prediction to conduct calibrations post-data acquisition and without relying on explicitly defined calibrants. We demonstrated the utility of this reference-free CCS calibration strategy for proteomics application using high-resolution structures for lossless ion manipulations (SLIM)-based IMS-MS. In conclusion, we first validated the accuracy of CCS values using a set of synthetic peptides and then demonstrated using a complex peptide sample from cell lysate.

59 BASIC BIOLOGICAL SCIENCES↗

Computational tools and algorithms for ion mobility spectrometry-mass spectrometry

Ion mobility spectrometry-mass spectrometry (IMS-MS or IM-MS) is a powerful analytical technique that combines the gas-phase separation capabilities of IM with the identification and quantification capabilities of MS. IM-MS can differentiate molecules with indistinguishable masses but different structures (e.g., isomers, isobars, molecular classes, and contaminant ions). The importance of this analytical technique is reflected by a staged increase in the number of applications for molecular characterization across a variety of fields, from different MS-based omics (proteomics, metabolomics, lipidomics, etc.) to the structural characterization of glycans, organic matter, proteins, and macromolecular complexes. With the increasing application of IM-MS there is a pressing need for effective and accessible computational tools. This article presents an overview of the most recent free and open-source software tools specifically tailored for the analysis and interpretation of data derived from IM-MS instrumentation. This review enumerates these tools and outlines their main algorithmic approaches, while highlighting representative applications across different fields. Finally, a discussion of current limitations and expectable improvements is presented.

59 BASIC BIOLOGICAL SCIENCES↗

Evaluating Software Tools for Lipid Identification from Ion Mobility Spectrometry–Mass Spectrometry Lipidomics Data

The unambiguous identification of lipids is a critical component of lipidomics studies and greatly impacts the interpretation and significance of analyses as well as the ultimate biological understandings derived from measurements. The level of structural detail that is available for lipid identifications is largely determined by the analytical platform being used. Mass spectrometry (MS) coupled with liquid chromatography (LC) is the predominant combination of analytical techniques used for lipidomics studies, and these methods can provide fairly detailed lipid identification. More recently, ion mobility spectrometry (IMS) has begun to see greater adoption in lipidomics studies thanks to the additional dimension of separation that it provides and the added structural information that can support lipid identification. At present, relatively few software tools are available for IMS-MS lipidomics data analysis, which reflects the still limited adoption of IMS as well as the limited software support. This fact is even more pronounced for isomer identifications, such as the determination of double bond positions or integration with MS-based imaging. In this review, we survey the landscape of software tools that are available for the analysis of IMS-MS-based lipidomics data and we evaluate lipid identifications produced by these tools using open-access data sourced from the peer-reviewed lipidomics literature.

59 BASIC BIOLOGICAL SCIENCES↗

Ion Mobility Spectrometry-Mass Spectrometry for High-Throughput Analysis

Ion mobility spectrometry is a widely used analytical technique providing gas phase separation of molecules. It has received increasing attention in the recent years with the advancement in technology development and the availability of commercial instruments. In this chapter, we introduced the ion mobility fundamental theory and provided examples of IMS applications, especially for isomer separation, collision cross section database generation, high throughput analysis workflows, software tools for IMS data analysis, and ongoing high resolution SLIM IMS development. While IMS is not yet routinely utilized in drug discovery and pharmaceutical industry, there has been increased interest in high throughput library screening and antibody characterization. With all the ongoing development in IMS technology and informatics, we foresee more and more exciting applications of high throughput IMS analysis in different fields including omics studies, drug discovery and clinical applications in the near future.

Ross, Dylan H.↗

Algorithms and file structures to enhance software workflows for ion mobility mass spectrometry (IM-MS)

Support customizations of algorithms and raw data file structures to enhance software workflows for liquid chromatography (LC), mass spectrometry (MS) and ion mobility mass spectrometry (IM-MS)-based metabolite characterization. Evaluate and improve the integration of ion mobility to existing MS analysis methods of the Mass Profiler Professional workflow (Mass Profiler, ID Browser and Mass Profiler Professional).

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Algorithms and file structures to extend and enhance liquid chromatography and ion mobility mass spectrometry workflows (CRADA Final Report)

The purpose of this project was to continue supporting customizations of algorithms and raw data file structures to enhance software workflows for liquid chromatography (LC), mass spectrometry (MS) and ion mobility mass spectrometry (IM-MS)-based protein and metabolite characterization. PNNL worked with Agilent to design, implement, evaluate, and demonstrate new algorithms and integrated them as functionalities into the PNNL-PreProcessor software. The project augmented PNNL’s capabilities to analyze complex proteomics and metabolomics samples. These capabilities are directly beneficial to DOE and PNNL efforts to characterize and analyze these compounds in microbial and plant communities. The project assisted Agilent in further developing improved instrument-software solutions combining liquid chromatography and ion mobility with mass spectrometry for widespread applications in life sciences and other fields.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

High resolution mobility spectrometry in a co-axial platform

Ion mobility spectrometry is an analytical technique that separate ions in the gas phase based on their interaction with a neutral buffer gas. Ion mobility spectrometry performs separations quickly (typically less than a second) and the ion mobilities are very reproducible across different laboratories. This project aimed at evaluating the performance of a new ion mobility device. The new device relies on conducting ion mobility separation in a curved geometry. The project explored the operation landscape of the device using ion trajectory simulations then fabricated and experimentally demonstrated the device's performance. Ion trajectory simulations on a set of tetraalkylammonium and phosphazene ions indicate that ions traveling a curved path length undergo mobility separation that is similar to a straight path. The ion mobility resolution of the curved device was found to be similar to that of a straight path of a similar length. The experimental validation of the new device confirmed the device's ability to separate ions according to their mobilities. Sets of mixtures (tetraalkylammonium ions, phosphazene ions, and peptide ions) were evaluated for separation and transmission.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Exploring Ion Mobility Mass Spectrometry Data File Conversions to Leverage Existing Tools and Enable New Workflows

Ion mobility (IM) is often combined with LC-MS experiments to provide an additional dimension of separation for complex sample analysis. While highly complex samples are better characterized by the full dimensionality of LC-IM-MS experiments to uncover new information, downstream data analysis workflows are often not equipped to properly mine the additional IM dimension. For many samples the data acquisition benefits of including IM separations are all that is necessary to uncover sample information and the full dimensionality of the data is not required for data analysis. Post-acquisition reduction and adaptation of the dimensions of LC-IM-MS and IM-MS experiments into an LC-MS format opens the possibility to use a plethora of existing software tools. In this work, we developed data file conversion tools to reduce the complexity of IM data analysis. Three data file transformations are introduced in the PNNL PreProcessor software: 1) mapping the IM axis to the LC axis for IM-MS data, 2) converting the drift time vs. m/z space to CCS/z vs m/z space, and 3) transforming All Ions IM/MS mobility aligned fragmentation data to a standard LC-MS DDA data file format. Finally, these new data file conversions are demonstrated with corresponding lipidomics and proteomics workflows that leverage existing LC-MS data analysis software to highlight the benefits of the data transformations.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

LipidOz enables automated elucidation of lipid carbon–carbon double bond positions from ozone-induced dissociation mass spectrometry data

Lipids play essential roles in many biological processes and disease pathology, but unambiguous identification of lipids is complicated by the presence of multiple isomeric species differing by fatty acyl chain length, stereospecifically numbered (sn) position, and position/stereochemistry of double bonds. Conventional liquid chromatography-mass spectrometry (LC-MS/MS) analyses enable the determination of fatty acyl chain lengths (and in some cases sn position) and number of double bonds, but not carbon-carbon double bond positions. Ozone-induced dissociation (OzID) is a gas-phase oxidation reaction that produces characteristic fragments from lipids containing double bonds. OzID can be incorporated into ion mobility spectrometry (IMS)-MS instruments for the structural characterization of lipids, including additional isomer separation and confident assignment of double bond positions. The complexity and repetitive nature of OzID data analysis and lack of software tool support have limited the application of OzID for routine lipidomics studies. Here, we present an open-source Python tool, LipidOz, for the automated determination of lipid double bond positions from OzID-IMS-MS data, which employs a combination of traditional automation and deep learning approaches. Our results demonstrate the ability of LipidOz to robustly assign double bond positions for lipid standard mixtures and complex lipid extracts, enabling practical application of OzID for future lipidomics.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Resolving metal binding properties within subunits of a multimeric enzyme Mnx by surface induced dissociation and native ion mobility mass spectrometry

Multi-subunit enzymes function as coordinated assemblies. Yet most enzymatic assays measure the summed output of all populations in solution and cannot easily differentiate contributions of individual subunits. Native mass spectrometry detects intact protein complexes in the gas phase. Surface induced dissociation further releases subunits from protein complexes while retaining compact conformations and bound ligands. Combined with ion mobility, the released subunits can then be carefully monitored for more in-depth structural analysis. Mnx is a unique bacterial multicopper oxidase complex that oxidizes Mn(II) to form MnO 2 minerals, and is composed of three subunits: MnxG, a multicopper oxidase containing the active site, and two accessory proteins, MnxE and MnxF which also bind copper ions. Other known multicopper oxidases do not require accessory proteins, therefore the functions of MnxE and MnxF are not well understood. Here, we use native mass spectrometry with surface induced dissociation and ion mobility to characterize the metal binding properties of Mnx with two metals, catalytic Cu(II) and Mn(II) substrate. We demonstrate our assay can detect subtle structural changes within each subunit, which are presumably related to the allosteric mechanism. We also noticed that ionic strength and solution composition can impact metal binding and must be carefully investigated for such experiments.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Ion Mobility – Mass Spectrometry Rapid Imaging of Special Nuclear Materials

Robot Nose will use new fast data throughput methods and experience with laser microfocus to dramatically improve the speed and spatial resolution of an established instrument, making it a useful tool for imaging special nuclear materials (SNM). Mass spectrometry imaging instruments have traditionally been too slow and mass alone is generally an insufficient measurement for organic analyses. This situation was markedly improved by Ionwerks Inc., who pioneered the combination of ion mobility with mass spectrometry imaging. In 2D mobility-mass plots, clearly identifiable trend lines can be selected and reduced to 1D mass spectra without isobaric interferences. This is a major advantage over other imaging mass spectrometers that generally cannot distinguish isobars without custom-built lasers or high voltage accelerators. Special nuclear material (SNM) contains substantial fissile isotopes, particularly 233U, 235U, and 239Pu. A complete forensic analysis of SNM therefore requires quantitative isotopic measurement – often through some form of mass spectrometry. SNM contaminated with inclusions such as pollen grains can help identify its prior locations. The project team is presently working on an approach to allow rapid screening of 1-3 cm diameter thin samples of such material.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Enabling Ultralow Volume Analysis with a High-Resolution Ion Mobility Mass Spectrometry Platform

Of all the molecules thought to exist in the universe, it is estimated that researchers only know the chemical structures of 5% of them. Identifying the chemical structures of the remaining 95% has proven extremely challenging because many molecules exhibit low abundance, are contained in small volumes (e.g., <10 nL), do not readily ionize, exhibit similar structures to other molecules, etc. No single analytical technique exists to definitively identify the structure of an unknown molecule, and thus multiple different molecular measurements are typically made (i.e., multi-modal approach). Ion mobility (IMS) and mass spectrometry (MS) are two key tools that researchers use to determine the chemical structures of unknown molecules, and recently high-resolution and ultrahigh resolution IMS-MS instruments have provided greater confidence than ever before. However, HR-IMS-MS instruments typically exhibit low ion utilization efficiency, meaning they require large amounts of sample for an analysis (e.g., >10 µL). Unfortunately, this limitation prohibits the analysis of small volume samples where many unknown molecules exist. Described herein are the efforts made to enable the analysis of ultralow volumes with an HR-IMS-MS platform. A new scanning technique, termed a ‘stuttered traveling wave scan’, was developed as a replacement for the dual-gated scanning technique and works by halting the traveling waves after allowing ions to separate and then repeatedly restarting and stopping the traveling waves to incrementally move ions from the SLIM to the Orbitrap. Ions were stored inside the SLIM while the TWs were stopped, allowing the Orbitrap to perform high-resolution mass analysis. When the Orbitrap was ready, the TWs were restarted for short periods of time (<10 ms) to move ions from the SLIM to the Orbitrap. It was discovered that lower TW amplitudes and speeds than used during IMS separation were required to produce IMS peaks with the highest signal intensities and best resolving powers. The stuttered TW scan was found to produce similar resolutions and signal intensities compared to the dual-gated scanning technique. A new IMS design possessing an intersecting ‘tee’ with a reversible traveling wave was also developed to improve ion utilization efficiency during cyclic operation, which is necessary when only a single IMS spectrum can be acquired, such as when analyzing ultralow volume samples. The new capabilities described in this report lay the groundwork for acquiring HR-IMS-MS spectra of ultralow volume biological samples, such as single cells, where HR-IMS-MS can help elucidate the structures of unknown compounds.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

mzapy : An Open-Source Python Library Enabling Efficient Extraction and Processing of Ion Mobility Spectrometry-Mass Spectrometry Data in the MZA File Format

We have recently reported MZA, a new and simple mass spectrometry data structure based on the broadly supported HDF5 format and created to facilitate software development. While this format is inherently supportive of application development, the availability of a core library with standard mass spectrometry utilities greatly facilitates fast software development. Here, we present a Python library, mzapy, for efficient extraction and processing of mass spectrometry data in the MZA format. In addition to raw data extraction, mzapy contains supporting utilities enabling tasks including calibration, signal processing, peak finding, and generating plots. Being implemented in pure Python with minimal and largely standardized dependencies makes mzapy uniquely suited to application development in the multi-omics domain. The free and open source mzapy is built with extensibility in mind, and future development will support cloud computing and artificial intelligence/machine learning applications. The software source code is freely available at https://github.com/PNNL-m-q/mzapy.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

A Dual-Gated Structures for Lossless Ion Manipulations-Ion Mobility Orbitrap Mass Spectrometry Platform for Combined Ultra-High-Resolution Molecular Analysis

High-resolution ion mobility spectrometry-mass spectrometry (HR-IMS-MS) instruments have enormously advanced the ability to characterize complex biological mixtures. Unfortunately, HR-IMS and HR-MS measurements are typically performed independently due to mismatches in analysis time scales. Here we overcome this limitation by using a dual-gated ion injection approach to couple an 11-meter path length structures for lossless ion manipulations (SLIM) module to a Q-Exactive Plus Orbitrap MS. The dual-gate setup was implemented by placing one ion gate before the SLIM module and a second ion gate after. The dual-gated ion injection approach allowed the new SLIM-Orbitrap platform to simultaneously perform an 11-meter SLIM separation, Orbitrap mass analysis using the highest selectable mass resolution setting (up to 140k), and high-energy collision induced dissociation (HCD) in ~25 minutes over an $m/z$ range of ~1500 amu. The SLIM-Orbitrap was initially characterized using a mixture of standard phosphazene cations and demonstrated an average SLIM CCS resolving power (Rp CCS ) of ~218 and SLIM peak capacity of ~156 while simultaneously obtaining high mass resolutions. SLIM-Orbitrap analysis with fragmentation was then performed on mixtures of standard peptides and two reverse peptides (SDGRG 1+ , GRGDS 1+ , Rp CCS = 305) to demonstrate the utility of combined HR-IMS-MS/MS measurements for peptide identification. Our new HR-IMS-MS/MS capability was further demonstrated by analyzing a complex lipid mixture and showcasing SLIM separations on isobaric lipids. In conclusion, this new SLIM-Orbitrap platform demonstrates a critical new capability for proteomics and lipidomics applications, and the high-resolution multimodal data obtainable with this system establishes the foundation for reference-free identification of unknown ion structures.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Accumulation of Large Ion Populations with High Ion Densities and Effects Due to Space Charge in Traveling Wave-Based Structures for Lossless Ion Manipulations (SLIM) IMS-MS

The accumulation of very large ion populations in traveling wave (TW)-based Structures for Lossless ion Manipulations (SLIM) has been studied to better understand aspects of ‘in-SLIM’ ion accumulation, and particularly its use in conjunction with ion mobility spectrometry (IMS). A linear SLIM ion path was implemented that had a ‘gate’ for blocking and accumulating ions for arbitrary time periods. Removing the gate potential caused ions to exit and the spatial distributions of accumulated ions were examined. The ion populations for a set of peptides were observed to increase with increased accumulation times until space change effects became significant, after which the peptide precursor ion populations decreased due to growing space charge-related ion activation, reactions, and losses. Ions closest to the gate were preferentially activated, and increasingly so with added storage times, TW amplitude, and the size of the total ion population. For analytical applications, we found that relatively weak TWs in the accumulation/storage region should be utilized to prevent or minimize ion losses and/or ion heating effects that can also lead to fragmentation. Our results further indicate that an accumulation region close to the SLIM entrance is advantageous for both speeding accumulation, minimizing ion heating, and avoiding ion population profiles that result in IMS peak tailing. Importantly, space charge-driven separations were observed for large populations of accumulated species and attributed to the opposing effects of space charge and the TW. In these separations, ion species form distributions or peaks, sometimes moving against the TW, and ordered in the SLIM based on their mobilities. Such separations may offer utility for ion pre-fractionation of ions and increasing the dynamic range measurements, increasing the resolving power of IMS separations by decreasing peak widths for accumulated ion populations, and other purposes benefitting from separations of extremely large ion populations.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Refining PeakDecoder Version 2

Novel computational tools for processing multidimensional mass spectrometry (MS) data are necessary to enable deeper and automated detection and quantification of metabolites in complex backgrounds. Multidimensional MS data includes measurements from liquid chromatography (LC) and ion mobility spectrometry (IM) separations, and precursor and fragment ion spectra collected in data-independent acquisition (DIA) mode. PeakDecoder is an artificial intelligence (AI)-based software that enables automated interpretation of this kind of data to identify and quantify individual metabolites in complex mixtures. The goal of this project was to improve and re-implement PeakDecoder in a better suited programming language to enable its commercialization.

97 MATHEMATICS AND COMPUTING↗

PeakDecoder enables machine learning-based metabolite annotation and accurate profiling in multidimensional mass spectrometry measurements

Multidimensional measurements using state-of-the-art separations and mass spectrometry provide advantages in untargeted metabolomics analyses for studying biological and environmental bio-chemical processes. However, the lack of rapid analytical methods and robust algorithms for these heterogeneous data has limited its application. Here, we develop and evaluate a sensitive and high-throughput analytical and computational workflow to enable accurate metabolite profiling. Our workflow combines liquid chromatography, ion mobility spectrometry and data-independent acquisition mass spectrometry with PeakDecoder, a machine learning-based algorithm that learns to distinguish true co-elution and co-mobility from raw data and calculates metabolite identification error rates. We apply PeakDecoder for metabolite profiling of various engineered strains of Aspergillus pseudoterreus, Aspergillus niger, Pseudomonas putida and Rhodosporidium toruloides. Results, validated manually and against selected reaction monitoring and gas-chromatography platforms, show that 2683 features could be confidently annotated and quantified across 116 microbial sample runs using a library built from 64 standards.

59 BASIC BIOLOGICAL SCIENCES↗