Engineering PapersSearch

SEARCH · Engineering Papers

Results for “inverter black box model”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

Experimental Setup and Learning-Based AI Model for Developing Accurate PV Inverter Models

The integration of power electronics-based interfaces presents challenges due to the absence of detailed models and the high computational complexity. Generic models used in system studies lack accuracy in capturing converter dynamics. This paper proposes a data-driven approach developed from experimental setup data. This approach enhances accuracy in photovoltaic inverter modeling. We used two types of PV inverters in the experiment. The recorded experimental data undergo processing through a machine learning model. Results from the model trained through machine learning is also presented.

artificial intelligence

Novel Approach to PV Inverter Modeling and Simulation Leveraging Experiments, Learning Based Modeling and Co-Simulation: Preprint

Photovoltaic inverter (PV) inverter manufacturers use custom, proprietary control approaches and topologies in their inverter design. Due to this proprietary nature, it is not possible to share EMT domain models for system studies. This research work presents a novel approach in experimental design, high fidelity data collection, use of learning-based modeling, and co-simulation to enhance the PV inverter modeling. We used a 20 kW off-the-shelf grid following PV inverter and subjected the inverter to controlled tests including voltage and frequency step changes, as well as solar irradiance variations. The recorded high frequency data was used in learning-based model training. This learning-based model was imported into an Electromagnetic Transient (EMT) simulation tool using co-simulation techniques to complete the modeling effort and integrate the model into an EMT simulation tool. The three key components in this research work are the design of experimental setup, use of learning-based approach for model development and use of co-simulation to complete the approach. The proposed approach will allow users to develop a model in a really short period of time and achieve reasonable inverter models.

artificial intelligence

Novel Approach to PV Inverter Modeling and Simulation Leveraging Experiments, Learning Based Modeling and Co-Simulation

Photovoltaic (PV) inverter manufacturers use custom, proprietary control approaches and topologies in their inverter design. The proprietary nature of these approaches makes it challenging to share electromagnetic transients (EMT) domain models for system studies. This research work presents an approach to develop EMT models from experimental data. We use novel approach in experimental design, high fidelity data collection, use of learning-based modeling, and co-simulation to reduce the time taken to develop an EMT model for an inverter under test (IUT). We used a 20 kW off-the-shelf grid following PV inverter and subjected the inverter to controlled tests. The tests include voltage and frequency step changes, as well as solar irradiance variations. The recorded high frequency data were used to train a neural network model representing the dynamic behavior of the IUT. The model was subsequently imported into an EMT tool using co-simulation techniques, and thus completing the modeling effort.

black box inverter modeling

Empirical Comparison of Machine Learning Approaches for Black-Box Modeling of Power Conversion System Dynamics

Inverter-based resources are key components in modern power systems, but accurately modeling their complex behavior can be challenging. Standard, generic converter models often oversimplify inverter dynamics, leading to significant errors in predicting performance. In this work, we compare several data-driven machine learning (ML) approaches for inverter modeling, performing experiments on power conversion systems, systematically varying input conditions, and recording the resulting voltages and currents. The ML models were then trained on this measured data to capture the inverter's dynamic response and to predict the inverter's output current. A performance comparison between the four ML models under study is conducted, laying the foundation for future work on hardware implementation for real-time inference.

30 DIRECT ENERGY CONVERSION

A Systematic Framework for Tuning Open-Source Multifunctional IBR Models To Emulate OEM Black-Box Fault Dynamics

This paper presents a systematic framework to tune a generic IBR EMT model to match with an OEM provided balckbox inverter model based on the fault current responses. The key learnings and findings are summarized as follows: The tunable key parameters include inner control loops and current limiters to align the fault current magnitude, sequence content, and phase trajectories with the OEM models across diverse fault type and locations. The tuned model's fidelity is validated through comparative analysis with an OEM blackbox model, assessing both the fault current response and the responses of multiple relay elements. The results demonstrate the tuned generic model can trigger relay decision logic that is identical or near identical to that of the OEM model, thus generating very good match model for fault studies.

24 POWER TRANSMISSION AND DISTRIBUTION

Study of the Protection Improvements for a Weak Grid Area With High Inverter-Based Resources (IBRs)

This project designs enhanced protection scheme for the real-world weak grid area with a high penetration of IBRs. As the existing protection schemes are originally designed for traditional synchronous machines, we first evaluate if the protection scheme will continue to operate reliably in systems with high levels of IBRs. Hardware relays are tested using a controller-hardware-in-the-loop setup. PSCAD electromagnetic transient simulation with IBR original equipment manufacturer black-box models is used to perform fault studies and generate COMTRADE data, which are replayed by a real-time digital simulator (RTDS) to feed input to the hardware relays. Three scenarios are analyzed: normal operation, an N-1 contingency, and an IBR-only scenario. The evaluation results reveal the following: 1) the protection scheme remains reliable under normal conditions and N-1 contingencies and 2) in IBR-only scenarios, differential protection (87L) continues to operate reliably, whereas local protection elements, such as distance and directional elements, fail because of the lack of regulated negative sequence current contributed by IBRs. Enhanced protection is designed to address the challenge of lack of negative sequence current from IBRs, including increased restraining factors a2 and k2 to block 32Q or using V instead QV ORDER for ground faults, enhanced mho distance element with voltage and phase angle supervision for L-L faults. The efficacy of enhanced protection logic is validated and proven to work reliably. Additionally, IEEE Std. 2800-2022 negative sequence current compliant GFL and GFM IBRs from another vendor are tested and proven to work reliably without need for enhanced logic. Therefore, this work provides valuable decision-making for utilities facing protection system challenges due to IBRs, either designing enhanced protection scheme or requesting their IBRs being IEEE Std. 2800-2022 compliant to produce regulated negative sequence current for protection relay to make correct decision.

24 POWER TRANSMISSION AND DISTRIBUTION

Evaluating Protection System Performance for a Real-World Weak Grid Area With High Inverter-Based Resources

This paper evaluates an existing protection scheme implemented in a real-world weak grid area with a high penetration of inverter-based resources (IBRs). The study aims to assess the reliability and adequacy of protection schemes originally designed for traditional synchronous machine systems and determine whether they can continue to operate reliably in systems with high levels of IBRs. Hardware relays are tested using a controller-hardware-in-the-loop setup. PSCAD electromagnetic transient simulation with an IBR original equipment manufacturer black-box model is used to perform fault studies and generate COMTRADE data, which are replayed by a realtime digital simulator (RTDS) to feed input to the hardware relays. Three scenarios are analyzed: normal operation, an N-1 contingency, and an IBR-only scenario. The evaluation results reveal the following: 1) the protection scheme remains reliable under normal conditions and N-1 contingencies and 2) in IBRonly scenarios, differential protection (87L) continues to operate reliably, whereas local protection elements, such as distance and directional elements, fail because of the lack of regulated negative sequence current contributed by IBRs. These findings provide utilities with valuable insights for improving their protection systems in high-IBRs.

24 POWER TRANSMISSION AND DISTRIBUTION

Evaluating Protection System Performance for a Real-World Weak Grid Area With High Inverter-Based Resources: Preprint

This paper evaluates an existing protection scheme implemented in a real-world weak grid area with a high penetration of inverter-based resources (IBRs). The study aims to assess the reliability and adequacy of protection schemes originally designed for traditional synchronous machine systems and determine whether they can continue to operate reliably in systems with high levels of IBRs. Hardware relays are tested using a controller-hardware-in-the-loop setup. PSCAD electromagnetic transient simulation with an IBR original equipment manufacturer black-box model is used to perform fault studies and generate COMTRADE data, which are replayed by a real-time digital simulator (RTDS) to feed input to the hardware relays. Three scenarios are analyzed: normal operation, an N-1 contingency, and an IBR-only scenario. The evaluation results reveal the following: 1) the protection scheme remains reliable under normal conditions and N-1 contingencies and 2) in IBR-only scenarios, differential protection (87L) continues to operate reliably, whereas local protection elements, such as distance and directional elements, fail because of the lack of regulated negative sequence current contributed by IBRs. These findings provide utilities with valuable insights for improving their protection systems in high-IBRs.

24 POWER TRANSMISSION AND DISTRIBUTION

Model of Inverter-Based Resources

Blackbox modelling for SC analysis is a possible solution. Accuracy can be acceptable even without having vendor control diagrams. Is an NDA required to share a vendor Blackbox model for SC analysis? Differences in VRT detection and injection logics. Angle rotation is not addressed in control logics of most vendors. Current limitation logic during unbalanced faults is not clear. Model IBR as a current source with shunt to improve convergence

IBRs, Model of IBRs, Short Circuit Analysis, Class

End-To-End Decentralized Transmission Line Protection in IBR-Dominated Weak Grids Using Interpretable Data-Driven Methods

Traditional transmission line protection relies on predictable synchronous-based fault signatures, which frequently fail under the non-standard, current-limited fault characteristics of Inverter-Based Resources (IBRs). This study investigates how to achieve secure, communication-free fault isolation in IBR-dominated weak grids without relying on opaque, computationally heavy "black-box" machine learning algorithms. To address this, we propose a novel, standalone, and inherently interpretable data-driven protection framework. Unlike centralized methods requiring multi-terminal communication, this decentralized approach relies solely on local measurements using a hierarchical linear-kernel Support Vector Machine (SVM). The methodology decomposes the protection task into four sequential stages that mimic traditional protection elements: fault detection and fault direction identification, fault type classification, zone classification, and location estimation. This multi-stage architecture allows for specialized feature engineering at each stage, combining high computational efficiency with logic traceability. The framework's end-to-end performance was validated via C-code and PSCAD/EMTDC co-simulation, utilizing a real-world utility network and an OEM black-box IBR model. The proposed relay achieves 97.2% overall accuracy and provides a reliable trip decision within a 2.5-cycle window. The results confirm 100% accuracy in fundamental fault detection, reliable zone selectivity across low to moderate fault resistances, and robust security against non-fault transients, proving its immediate viability for integration into commercial numerical relays.

24 POWER TRANSMISSION AND DISTRIBUTION

Identifying Potential Sub-Synchronous Oscillations Using Impedance Scan Approach: Preprint

This paper presents an impedance scan study on the real-world power system in Australia that has observed 17 to 20 Hz intermittent subsynchronous oscillations. Through the impedance scan of each of the IBRs, both individually and collectively, potential resonance modes are identified. The impedance scans were carried out using electromagnetic transient PSCAD models of the network. The network comprises of site-specific, black-boxed models of IBRs supplied by the generators. The impedance scan approach was divided in three major steps: (1) the first step is to identify IBRs where impedance analysis needs to be performed based on the magnitude of oscillations observed at their points of interconnection (POIs); (2) the second step focuses on performing impedance scans at selected IBRs in single-machine infinite-bus (SMIB) configuration to identify internal resonance modes of an IBR and to evaluate if any of these modes become unstable under certain grid conditions; (3) the third step performs impedance scans at a few selected IBRs while connected to the wider network model to obtain the impedance response of both the IBR and the grid - this step evaluates control interactions among IBRs. The impedance scan study found that a few IBRs have an underdamped resonance mode at around 17 Hz, which becomes unstable under a certain operating condition. Another interesting finding was that certain IBRs increase the effective grid impedance seen by another IBR in proximity for a particular operating condition. Under this operating condition, the resulting subsynchronous oscillation mode is more pronounced due to a combination of control interactions among IBRs through the transmission network under study and a resonance mode inside the IBRs.

control interactions