At least 19 records

Differentiation of static and dynamic interfacial area in the structured packed column

Effective mass-transfer area plays a key role for post-combustion carbon capture. The static area, an inactive part relative to mass transfer, needs to be differentiated in the interfacial area. In the present study, CFD method is employed to investigate static and dynamic interfacial areas in Mellapak 500.Y structured packing. Here, a wide range of physical properties and loading conditions are included to understand their effects on both areas. The result shows that the relationship between interfacial area and interfacial velocity at the local scale can be described by gamma distribution with good accuracy. The influences of various physical properties derived from simulation are compared with existing experiment-based correlations for both static and interfacial areas. The result shows the dominant influence of viscosity on the static area, and the most importance of the influence of contact angle on the interfacial area. This study also highlights the importance of viscosity, which is usually ignored.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Benchmark of interfacial area concentration approaches for the two-fluid model in gas-dispersed condensing flow

Accurate predictions of interfacial area concentration (IAC) are required for closure of the condensation phase change term. The interfacial area transport equation (IATE) can dynamically predict interfacial area concentration and is increasingly being used in the benchmarking of phase change flows over static based correlations which require a flow regime map. For higher flow regimes, the two-group two-fluid IATE model can separately model the transport of spherical bubbles and cap/slug bubbles. Recently, a modified formulation of the one-group and two-group two-fluid model with interfacial area transport equation was proposed for gas-dispersed condensing flows. Three datasets have been used for validation consisting of condensing two-phase flow data in the unheated section of a vertical annulus with conditions spanning a range of pressures, inlet subcoolings and mass fluxes for benchmarking the various IAC approaches. For bubbly flows, the coupled void transport - IATE simulation results in good agreement in the predictions of the void fraction and the interfacial area concentration under nearly all sixty conditions. Considering the proposed two-group two-fluid IATE model formulation, the group-2 Nusselt number correlation is investigated to account for the appropriate heat transfer length scale for group-2 bubbles. Validation of the proposed two-group two-fluid model against the new dataset shows good agreement with experimental data with significant improvement over the one-group IATE model for conditions with substantial group-2 void fraction throughout the simulation domain.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Microtomographic Measurements of Total Air‐Water Interfacial Areas for Soils

Abstract Synchrotron X‐ray microtomography (XMT) was used to measure total air‐water interfacial areas (A aw ) as a function of water saturation (S w ) for several soils that comprise a range of physical and geochemical properties. Measurements were also conducted for glass beads and quartz sands for comparison. Apparent near‐linearA aw ‐S w relationships are observed for the three sands and the three sandy soils. In contrast, the measured interfacial areas for two soils that contain greater proportions of silt and clay are strongly nonlinear functions of water saturation. The greater degree of nonlinearity observed for these two soils is due to their much greater particle‐size distributions (i.e., uniformity coefficients) and their concomitant greater range in pore sizes. Interfacial areas determined with the thermodynamic method were used to benchmark the XMT measurements. XMT‐measured interfacial areas compare well to the thermodynamic‐determined values for the sands and sandy soils. In contrast, the XMT‐measured interfacial areas for the two soils with larger particle‐size distributions are not fully congruent with the thermodynamic‐determined values. Both of these soils have large fractions of pore space comprising nominal pore diameters smaller than the resolution of the XMT imaging. These results suggest that air‐water interfacial area may not always be fully characterized by standard XMT for soils with large particle‐size distributions.

Environmental Sciences & Ecology↗

Fluid/Fluid Interfacial Areas Measured for Different Non-Wetting/Wetting Fluid Pairs in Natural Porous Media

This study examined the impact of fluid type and grain diameter on the interfacial area between different pairs of non-wetting and wetting fluids in natural porous media. Synchrotron X-ray microtomography was used to obtain high-resolution, three-dimensional images of multi-phase porous media systems. Multiple porous media, comprising a range of physical and geochemical properties, were used in this study. The four pairs of non-wetting/wetting fluids used were dense OIL/water, light OIL/water, air/dense OIL, and air/water. Images were obtained over a broad range of wetting phase saturation and for both wetting phase drainage and imbibition conditions. The results showed that for each fluid pair, the total (capillary + film) interfacial area increased with decreasing wetting fluid saturation. Interfacial areas were similar among all fluid pairs for a given porous medium. They were also similar for drainage and imbibition conditions. The maximum specific interfacial area (A m ) was shown to correlate well with inverse median grain diameter. The physical properties of the porous medium appear to have a greater influence on the magnitude of specific total interfacial area for a given saturation than fluid properties or wetting phase history.

NAPL↗

The influence of random packed column parameters on the liquid holdup and interfacial area

Abstract Carbon dioxide capture via solvent absorption in packed columns has emerged as a potential technology to mitigate coal‐fired power plant CO 2 emissions. Parameters, including packing types, solvent properties, and operating conditions, could potentially affect the packed column CO 2 capture efficiency. To understand the importance of those parameters and help packed column optimization, a design of experiments (DoEs) method was proposed to generate input parameter matrix. Combined with multiphase computational fluid dynamics (CFD), the random packed column parameter influence on the liquid holdup and interfacial area can be efficiently investigated. Surrogate‐based sensitivity analysis shows that the solvent flow rate and contact angle are key factors dictating liquid holdup and interfacial area. On the other hand, solvent viscosity has a marginal impact on the interfacial area. The sensitivity scores were calculated for each input parameter to guide the selection of dimensionless numbers for the liquid holdup and interfacial area correlation development.

42 ENGINEERING↗

Bipolar membrane polarization behavior with systematically varied interfacial areas in the junction region

The palette of applications for bipolar membranes (BPMs) has expanded recently beyond electrodialysis as they are now being considered for fuel cell and electrolysis applications. Their deployment in emerging electrochemical technologies arises from the need to have a membrane separator that provides disparate pH environments and to prevent species crossover. Most materials research for BPMs has focused on water dissociation catalysts and less emphasis has been given to the design of the polycation–polyanion interface for improving BPM performance. Here, soft lithography fabricated a series of micropatterned BPMs with precise control over the interfacial area in the bipolar junction. Polarization experiments showed that a 2.28× increase in interfacial area led to a 250 mV reduction in the onset potential. Additionally, the same increase in interfacial area yielded marginal improvements in current density due to the junction region being under kinetics-diffusion control. A simple physics model based on the electric field of the junction region rationalized the reduction in the overpotential for water dissociation as a function of interfacial area. Finally, the soft lithography approach was also conducive for fabricating BPMs with different chemistries ranging from perfluorinated polymer backbones to alkaline stable poly(arylene) hydrocarbon polymers. These polymer chemistries are better suited for fuel cell and electrolysis applications. The BPM featuring the alkaline stable poly(terphenyl) anion exchange membrane had an onset potential of 0.84 V, which was near the thermodynamic limit, and was about 150 mV lower than a commercially available variant.

25 ENERGY STORAGE↗

Fluid – Fluid Interfacial Area and Its Impact on Relative Permeability - A Pore Network Modeling Study

Abstract Relative permeability (kr) is commonly modeled as an empirical function of phase saturation. Although current empirical models can provide a good match of one or two measured relative permeabilities using saturation alone, they are unable to predict relative permeabilities well when there is hysteresis or when physical properties such as wettability change. Further, current models often result in relative permeability discontinuities that can cause convergence and accuracy problems in simulation. To overcome these problems, recent research has modeled relative permeability as a state function of both saturation (S) and phase connectivity (X). Pore network modeling (PNM) data, however, shows small differences in relative permeability for the same S-X value when approached from a different flow direction. This paper examines the impact of one additional Minkowski parameter (Mecke and Arns, 2005), the fluid-fluid interfacial area, on relative permeability to identify if that satisfactorily explains this discrepancy. We calculate the total fluid-fluid interfacial areas (IA) during two-phase (oil/water) flow in porous media using pore network modeling. The area is calculated from PNM simulations using the areas associated with corners and throats in pore elements of different shapes. The pore network is modeled after a Bentheimer sandstone, using square, triangular, and circular pore shapes. Simulations were conducted for numerous primary drainage and imbibition cycles at a constant contact angle of 0° for the wetting phase. Simultaneous measurements of capillary pressure, relative permeability, saturation, and phase connectivity are made for each displacement. Fluid-fluid interfacial area is calculated from the PNM capillary pressure, the fluid location in the pore elements, and the pore element dimensional data. The results show that differences in the relative permeability at the same (S,X) point is explained well by differences in the fluid-fluid interfacial area (IA). That is, for a larger change in IA at these intersection points, the permeability difference is greater. That difference in relative permeability approaches zero as the difference in IA approaches zero. This confirms that relative permeability can be modeled better as a unique function of S, X, and IA. The results also show that an increase in IA restricts flow decreasing the nonwetting (oil) phase permeability. This decrease is caused by an increase in the throat area fraction compared to the corner area as the total area IA increases. The wetting phase relative permeability, however, shows the inverse trend, in that its relative permeability is greater when IA becomes larger owing to a greater fraction of the total area associated with the corners. The area IA, however, impacts the nonwetting phase relative permeability more than the wetting phase relative permeability. Corner flow improves the wetting phase relative permeability because the wetting phase is continuous there. Finally, a sensitivity analysis shows that relative permeability a is more sensitive to change in S than they are for IA for the case studied implying that if only two parameters are used to model relative permeability it is better to choose S and X.

Engineering↗

Thermocapillary migration of a drop: an exact solution with Newtonian interfacial rheology and stretching/shrinkage of interfacial area elements for small Marangoni numbers

In this paper we analyze the effects of the following phenomena associated with the thermocapillary migration of a drop. The first is the influence of Newtonian surface rheology of the interface and the second is that of the energy changes associated with stretching and shrinkage of the interfacial area elements, when the drop is in motion. The former occurs because of dissipative processes in the interfacial region, such as when surfactant molecules are adsorbed at the interface in sufficient concentration. The interface is typically modeled in this instance by ascribing to it a surface viscosity. This is a different effect from that of interfacial tension gradients arising from surfactant concentration gradients. The stretching and shrinkage of interfacial area elements leads to changes in the internal energy of these elements that affects the transport of energy in the fluids adjoining the interface. When an element on the interface is stretched, its internal energy increases because of the increase in its area. This energy is supplied by the neighboring fluids that are cooled as a consequence. Conversely, when an element on the interface shrinks, the adjoining fluids are warmed. In the case of a moving drop, elements of interfacial area are stretched in the forward half of the drop, and are shrunk in the rear half. Consequently, the temperature variation on the surface of the drop and its migration speed are modified. The analysis of the motion of a drop including these effects was first performed by LeVan in 1981, in the limit when convective transport of momentum and energy are negligible. We extend the analysis of LeVan to include the convective transport of momentum by demonstrating that an exact solution of the momentum equation is obtained for an arbitrary value of the Reynolds number. This solution is then used to calculate the slightly deformed shape of the drop from a sphere.

Rheology/methods↗

Two-Fluid Models and Interfacial Area Transport in Microgravity Condition

The objective of the present study is to develop a two-fluid model formulation with interfacial area transport equation applicable for microgravity conditions. The new model is expected to make a leapfrog improvement by furnishing the constitutive relations for the interfacial interaction terms with the interfacial area transport equation, which can dynamically model the changes of the interfacial structures. In the first year of this three-year project supported by the U.S. NASA, Office of Biological and Physics Research, the primary focus is to design and construct a ground-based, microgravity two-phase flow simulation facility, in which two immiscible fluids with close density will be used. In predicting the two-phase flow behaviors in any two-phase flow system, the interfacial transfer terms are among the most essential factors in the modeling. These interfacial transfer terms in a two-fluid model specify the rate of phase change, momentum exchange, and energy transfer at the interface between the two phases. For the two-phase flow under the microgravity condition, the stability of the fluid particle interface and the interfacial structures are quite different from those under normal gravity condition. The flow structure may not reach an equilibrium condition and the two fluids may be loosely coupled such that the inertia terms of each fluid should be considered separately by use of the two-fluid model. Previous studies indicated that, unless phase-interaction terms are accurately modeled in the two-fluid model, the complex modeling does not necessarily warrant an accurate solution.

Ishii, Mamoru↗

Sensitivity Analysis of Fluid–Fluid Interfacial Area, Phase Saturation and Phase Connectivity on Relative Permeability Estimation Using Machine Learning Algorithms

Recent studies have shown that relative permeability can be modeled as a state function which is independent of flow direction and dependent upon phase saturation (S), phase connectivity (X), and fluid–fluid interfacial area (A). This study evaluates the impact of each of the three state parameters (S, X, and A) in the estimation of relative permeability. The relative importance of the three state parameters in four separate quadrants of S-X-A space was evaluated using a machine learning algorithm (out-of-bag predictor importance method). The results show that relative permeability is sensitive to all the three parameters, S, X, and A, with varying magnitudes in each of the four quadrants at a constant value of wettability. We observe that the wetting-phase relative permeability is most sensitive to saturation, while the non-wetting phase is most sensitive to phase connectivity. Although the least important, fluid–fluid interfacial area is still important to make the relative permeability a more exact state function.

47 OTHER INSTRUMENTATION↗

Characterizing the pore-scale impacts of enhanced-solubilization solutions on organic-liquid morphology and fluid-fluid interfacial area with microtomography

Synchrotron X-ray microtomography was used to directly quantify the impact of enhanced-solubilization solutions on mobilization of a non-wetting fluid in a natural porous medium. Polyoxyethylene sorbitan monooleate (tween 80), hydroxypropyl-β-cyclodextrin (HPCD), sodium dodecyl sulfate (SDS), and ethanol were used as the solubilization reagents. Tetrachloroethene (PCE) was used as the entrapped organic immiscible liquid. Microtomography images were collected prior to and after successive floods with each reagent solution. The total trapping number was varied by more than three orders of magnitude by changing the velocity and viscosity of the aqueous phase as well as the interfacial tension between fluid phases. The results were compared to those obtained from equivalent experiments conducted with water flooding. Inspection of images indicated that mobilization caused a change in PCE morphology and distribution for all reagents with the exception of HPCD, for which a lower trapping number was determined compared to the other experiments. Mobilization of organic liquid was observed at total trapping numbers that were consistent with prior work. The enhanced-solubilization solutions had minimal impact on the configuration or magnitude of fluid-fluid interfacial area.

Interfacial area↗

Laser Ablation Increases PEM/Catalyst Interfacial Area

An investigational method of improving the performance of a fuel cell that contains a polymer-electrolyte membrane (PEM) is based on the concept of roughening the surface of the PEM, prior to deposition of a thin layer of catalyst, in order to increase the PEM/catalyst interfacial area and thereby increase the degree of utilization of the catalyst. The roughening is done by means of laser ablation under carefully controlled conditions. Next, the roughened membrane surface is coated with the thin layer of catalyst (which is typically platinum), then sandwiched between two electrode/catalyst structures to form a membrane/ele c t - rode assembly. The feasibility of the roughening technique was demonstrated in experiments in which proton-conducting membranes made of a perfluorosulfonic acid-based hydrophilic, protonconducting polymer were ablated by use of femtosecond laser pulses. It was found that when proper combinations of the pulse intensity, pulse-repetition rate, and number of repetitions was chosen, the initially flat, smooth membrane surfaces became roughened to such an extent as to be converted to networks of nodules interconnected by filaments (see Figure 1). In further experiments, electrochemical impedance spectroscopy (EIS) was performed on a pristine (smooth) membrane and on two laser-roughened membranes after the membranes were coated with platinum on both sides. Some preliminary EIS data were interpreted as showing that notwithstanding the potential for laser-induced damage, the bulk conductivities of the membranes were not diminished in the roughening process. Other preliminary EIS data (see Figure 2) were interpreted as signifying that the surface areas of the laser-roughened membranes were significantly greater than those of the smooth membrane. Moreover, elemental analyses showed that the sulfur-containing molecular groups necessary for proton conduction remained intact, even near the laser-roughened surfaces. These preliminary results can be taken as indications that laser-roughened PEMs should function well in fuel cells and, in particular, should exhibit current and power densities greater than those attainable by use of smooth membranes.

Whitacre, Jay↗

Hydrodynamics of countercurrent flows in a structured packed column: effects of initial wetting and dynamic contact angle

The structured packed column has gained considerable attention as a prospective technology to mitigate carbon dioxide emissions from thermal power plants. The computational flow investigation of such systems is a multiscale problem, and local hydrodynamics plays a key role in overall column efficiency. Accordingly, multiphase flow studies in the representative elementary unit (REU) of a packed column can offer insights into the local flow behavior such as flow pattern, interfacial area, etc. The interfacial area plays a key role in the overall interphase mass transfer and thereby in separation efficiency. The predicted effective area matches well with corresponding ones in experiments for Mellapak 250.Y packings. The contact angle (i.e., solid substrate behavior) is one of the critical factors that dictates wettings, and thereby the interfacial area. The dynamic contact angle (DCA) was considered in order to explore the effects of contact angle hysteresis on the interfacial area. DCA has more pronounced impact on the interfacial area for a solvent possessing a higher value of surface tension and equilibrium contact angle. The interfacial area shows temporal undulation and does not achieve a pseudo steady state due to the capillary force. In contrary, the interfacial area gets a net value for a solvent having low surface tension value. Further, specification of the static contact angle at the solid substrate shows the least value of the interfacial area. We also extensively studied the effect of the initial sheet condition (dry vs wet) on the interfacial area. The initially wetted sheets show slightly higher value of the interfacial area as compared to the initially dry sheets at a fixed flow rate for a solvent having high surface tension value. Wetting hysteresis decreases with increasing liquid loads. On the other hand, wetting hysteresis does not occur for a solvent having value of low surface tension and equilibrium contact angle.

structured packings, dynamic contact angle, interf↗

Hydrodynamics of countercurrent flow in an additive-manufactured column with triply periodic minimal surfaces for carbon dioxide capture

Computational investigation of the countercurrent flows in an additively manufactured (AM) column packed with triply periodic minimal surface (TPMS) is challenging. Multiphase flow simulations using the volume of fluid (VOF) method can explain the column’s hydrodynamic characteristics, including interfacial area, liquid holdup, pressure drop, flow regime, etc. The interfacial area is a key factor dictating the mass transfer via the absorption process, and thereby the overall efficiency of the column. The impacts of a solvent's physical properties, liquid and gas loads, and contact angle on the hydrodynamics are extensively explored. The solvents include traditional solvent (monoethanolamine [MEA]) used in industry as well as a water-lean solvent (EEMPA) as prospective solvents for carbon capture. As expected, interfacial area and liquid holdup increase with increasing liquid loads (q L ). The EEMPA exhibits higher values for the interfacial area and liquid holdup compared to those for the MEA. The dry and wet pressure drops per unit length in the column at different gas loads (F G ) are calculated and further compared with the empirical correlations for traditional packings. At low gas loads, i.e., in the preloading regime, the predicted values of the wet and dry pressure drops match well with the corresponding values calculated from available correlations. The gas load has a marginal impact on the interfacial area at its lower value, but the higher value of F G (>2.18 $\sqrt{Pa}$) causes flooding in the column. The effect of varying contact angles on the interfacial area and liquid holdup in the preloading regime is also studied. Both interfacial area and liquid holdup decrease with the increase in the value of the contact angle. Altogether, the effect of the contact angle on interfacial area is more pronounced than other parameters influencing the interfacial area.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Countercurrent flow characteristics of next generation solvent in novel 3D printed columns for carbon capture

Solvent based absorption for carbon dioxide capture in a packed column is being considered as an efficient technology for the decarbonization process of point source. Significant efforts are underway to improve the design of packings with the cutting edge 3D printing technology for efficient carbon capture. Accordingly, multiphase flow studies were conducted to assess the performance of novel 3D printed columns with various triply periodic minimal surface (TPMS) designs. The effects of solvent properties, liquid and gas loads on the performance of TPMS columns are extensively explored. Hydrodynamics of the potential water-lean solvents (EEMPA) as well as aqueous monoethanolamine (MEA) solvent for carbon capture are evaluated and compared. The interfacial area and liquid holdup increase with increasing liquid loads (q L ) for TPMS columns. Schwarz column consistently shows the highest liquid holdup value. The EEMPA exhibits higher values for the interfacial area (10–15 %) and liquid holdup (~4 %) in comparison to the MEA. TPMS columns exhibit the intermediate value of dry pressure drop between the random and the structure packed columns. Among selected TPMS columns, the gyroid packing shows the lowest pressure drop. The gas load has marginal impact on the interfacial area at lower value while a higher gas load leads to column’s flooding. Prior to the flooding, the interfacial area in TMPS packings rises with increased gas load at a fixed liquid load except Schwarz packing where interfacial area is incentive to the gas load. Additionally, the liquid holdup and wet pressure drop rise as gas load increases in TPMS columns. Overall, Fisher Koch packing is more susceptible to flood as compared to other TPMS packings. Flow regimes: loading and flooding are also delineated in the TPMS packings.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗