A Review of the Current Landscape of Distributed Wind Interconnection Standards
Explore the source record for details and available documents.
SEARCH · Engineering Papers
Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.
Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.
Explore the source record for details and available documents.
Grid interconnection has emerged as a significant obstacle to the development of new electricity resources. There is growing interest in energy-only interconnection, which is an interconnection service option meant to allow the interconnection of new generators without ensuring their energy deliverability during all hours through the transmission system to customers. This approach potentially avoids upfront congestion-related transmission upgrades but could increase curtailment risk. Interest in energy-only interconnection is shaped by incomplete understanding of how interconnection policy functions in different jurisdictions, a knowledge gap that makes it difficult to determine how energy-only interconnection might be better used or re-designed. In this paper, we provide a regulatory review of energy-only interconnection in U.S. interconnection policy and practice, identifying jurisdictions in which rules are close to -or farther from-the theoretical concept of energy-only interconnection service. We find substantial jurisdictional differences in how energy-only interconnection is implemented, driven by differences in resource adequacy frameworks, real-time transmission operations, and state-level procurement practices. U.S. regulators have preferred local jurisdictional flexibility over federal prescription of interconnection study methods and procedures, which also contributes to differences among regions. Such findings raise fundamental questions about whether competition policies in electricity markets should extend beyond spot energy markets and into more prescriptive guidelines around interconnection rules and market entry. This paper sheds light on tensions that energy-only interconnection raises in allowing generators to access the transmission system on an as available basis and discusses how controlling thresholds for congestion-related network upgrades may be a barrier to electricity market entry.
For ETOX Flash technology. the self-aligned source module plays a critical role in minimizing cell size. For advanced Flash technology using the shallow-trench isolation (STI) scheme, however, it is difficult to form a stable source line. The Flash process in this experiment features an ETOX structure and with SIN spacer. Poly-Si (implanted poly) is used as the local interconnection material connecting the source line and was successfully implemented in the ETOX flash array in this paper.
Abstract Interconnect materials play the critical role of routing energy and information in integrated circuits. However, established bulk conductors, such as copper, perform poorly when scaled down beyond 10 nm, limiting the scalability of logic devices. Here, a multi‐objective search is developed, combined with first‐principles calculations, to rapidly screen over 15,000 materials and discover new interconnect candidates. This approach simultaneously optimizes the bulk electronic conductivity, surface scattering time, and chemical stability using physically motivated surrogate properties accessible from materials databases. Promising local interconnects are identified that have the potential to outperform ruthenium, the current state‐of‐the‐art post‐Cu material, and also semi‐global interconnects with potentially large skin depths at the GHz operation frequency. The approach is validated on one of the identified candidates, CoPt, using both ab initio and experimental transport studies, showcasing its potential to supplant Ru and Cu for future local interconnects.
Strategy support to determine the best approach to deploy solar technologies and commercially viable heat pump projects across their existing Rural Energy Partners solar project development support channel.
Geothermal energy development requires downhole tools that operate reliably at temperatures up to 320 °C. While MWD tools work without thermal protection and logging tools use vacuum flasks for limited high-temperature use, Sandia National Laboratories is developing durable electronics on ceramic PCBs with protective coatings to enable long-term operation of geothermal instruments at sustained temperatures up to 300 °C.
ABSTRACT The performance of organic solar cells (OSCs) is governed by how molecular packing evolves into interconnected networks that facilitate exciton dissociation and charge transport. Using an all‐small‐molecule blend DR3TSBDT:Y6 as a model system, we study how local molecular stacking evolves into performance‐relevant morphology during solvent vapor annealing (SVA) and subsequent thermal annealing (TA). SVA promotes end‐to‐end stacking of amorphous acceptors to form interconnected fibrils, while TA compacts inter‐fibril spacing without disrupting favorable local order. Such molecular‐to‐morphological refinements broaden light absorption, enhance charge transport, and markedly improve device efficiency. Extending this approach to additional blend systems (D18:Y6, D18:L8‐BO, and DR3TSBDT:L8‐BO) yields similar structural evolution and performance gains, with the D18:L8‐BO system achieving up to 20.10% PCE. Our study establishes control over local stacking in amorphous acceptors into fibrillar networks as a general and effective route to realize high‐performance OSCs.
Electric transmission system operators (ISOs, RTOs, or utilities) require proposed power plants seeking to connect to the transmission grid to undergo a series of impact studies before they can be built. This process establishes what new transmission equipment or upgrades may be needed before a project can connect to the system and assigns the costs of that equipment. The lists of projects in this process are known as “interconnection queues”. In collaboration with https://www.interconnection.fyi. Berkeley Lab compiled, aggregated, and cleaned interconnection queue data from >50 transmission grid operators (7 ISO/RTOs and 50 non-ISO balancing areas), which collectively represent ~98% of currently installed U.S. electric generating capacity.
On 27 December 2024, Juno's JIRAM (Jovian InfraRed Auroral Mapper) instrument observed an unprecedented volcanic event in Io's southern hemisphere, covering a vast region of ∼65,000 km2, near 73°S, 140°E. Within the imaged region, only one hot spot was previously known (Pfd454). This feature was earlier estimated to cover an area of 300 km2 with a total power output of 34 GW. JIRAM results show that the region produces a power output of 140–260 TW, over 1,000 times higher than earlier estimates and likely exceeding the brightest eruption ever recorded on Io, that of Surt in 2001 (∼80 TW). Three adjacent hot spots also exhibited dramatic power increases: P139, PV18, and an unnamed feature south of the main one that surged to ∼1 TW, placing all of them among the top 10 most powerful hot spots observed on Io. A temperature analysis of the features supports the simultaneous onset of these brightenings and suggests a single eruptive event propagating beneath the surface across hundreds of kilometers; this is the first time this has been observed on Io. This in turn would imply a connection among the hotspots' magma reservoirs, while other nearby hotspots that have been known to be active in the recent past, such as Kurdalagon Patera, appear unaffected. The simultaneity supports models of massive, interconnected magma reservoirs. The topology of these regional magma systems may resemble that of a large-scale sponge, in which the massive reservoirs are the pores, interconnected through a largely solid outer shell.
Power electronic converters are an enabling technology for the emerging marine energy applications, such as using ocean waves to produce electricity. This paper outlines the power take-off system and its key components used in a wave energy converter offering modularity and scalability to generate power efficiently. The proposed power take-off system was implemented based on a modular multilevel converter and could be deployed to convert any alternating current electrical energy to a different alternating current for interconnection to grid or non-grid applications. Examples of widespread deployment are supplying electricity to coastal communities or producing clean drinking water. The analysis using both the simulation tests and laboratory experiments verified the design objectives and basic functionality of the developed power take-off system. An acceptable response using a field programmable gate array-based controlled laboratory testbench was achieved, complying with guidelines specified in the prevalent industry standards. Seamless operation during steady-state and transients for the studied wave energy converter was achieved as supported by the obtained results. The key findings of this work were experimentally examined under different load conditions, direct current bus voltage fluctuations, and generator speed–torque regulation. The ability of the power take-off system to generate high-power quality of the waveforms, e.g., against adhering to the IEEE 519-2022 standard for total harmonic distortion limits, is also confirmed.
V2G AC is a type of grid interconnection by mobile battery that transforms an EV into a DER with the potential to stabilize the grid and lower costs for electricity. UL 1741SC is a critical new standard to enable grid interconnection of V2G AC-capable vehicles, by defining requirements for V2G AC-intended EVSEs as a gatekeeper between the grid and the EV to support grid safety, such as through redundant voltage trip (namely oversight). EVSE manufacturers need a clear set of conformance test cases and criteria by which to evaluate their equipment and confirm the compliance with UL 1741SC, so that the EVSEs performs as intended for the grid safety. Hence, NLR identified necessary conformance tests and performed the tests identified to understand the maturity.
This work will focus on analysis of defects in modules fabricated using a conductive backsheet. While most defect types are known, reasonable methods for easily detecting manufactured defects are still relatively unknown.
Solar cells in space plasma conditions are known to arc into the plasma when the interconnects are at a negative potential of a few hundred volts, relative to plasma potential. For cells with silver-coated interconnects, a threshold voltage for arcing exists at about -230 V, as found in both ground and LEO experiments. The arc rate beyond the threshold voltage depends nearly linearly on plasma density, but has a strong power-law dependence on voltage, such that for small increments in operating voltage there is a large increment in arc rate. The arcs generate broadband radio interference and visible light. In ground tests, interconnects have been damaged by arcs in cells having insufficient isolation from a source of high current. Models for the arcs are highly dependent on the choice of interconnect conductor material exposed to the plasma and possibly on the geometry and choice of adjacent insulator material. Finally, new technology solar cells use copper for the cell interconnects, a material which may have a lower arcing threshold voltage than silver. It is expected, from ground tests of simulated solar cells, that any junction of conductor and insulator exposed to space plasma conditions will arc into the plasma at a few hundred volts negative potential, relative to the local plasma.
Sealed electric storage battery with gas manifold interconnecting each cell
A battery cell balancing system is operable to utilize a relatively small number of transformers interconnected with a battery having a plurality of battery cells to selectively charge the battery cells. Windings of the transformers are simultaneously driven with a plurality of waveforms whereupon selected battery cells or groups of cells are selected and charged. A transformer drive circuit is operable to selectively vary the waveforms to thereby vary a weighted voltage associated with each of the battery cells.
This report summarizes the outcomes, accomplishments, challenges, and lessons learned from Verde’s Cully Community Solar project, funded by the U.S. Department of Energy’s Solar Energy Technologies Office. The project focused on advancing community solar development through engineering, permitting, interconnection, ecological site design, workforce development, and community engagement. During the project period, Verde and its partners successfully developed and commissioned a 1.25 MW ground-mounted community solar system while also advancing planning for additional community solar capacity and developing approaches that can inform future projects in complex urban environments.
A battery monitoring system utilizes a plurality of transformers interconnected with a battery having a plurality of battery cells. Windings of the transformers are driven with an excitation waveform whereupon signals are responsively detected, which indicate a health of the battery. In one embodiment, excitation windings and sense windings are separately provided for the plurality of transformers such that the excitation waveform is applied to the excitation windings and the signals are detected on the sense windings. In one embodiment, the number of sense windings and/or excitation windings is varied to permit location of underperforming battery cells utilizing a peak voltage detector.
A battery system utilizes a plurality of transformers interconnected with the battery cells. The transformers each have at least one transformer core operable for magnetization in at least a first magnetic state with a magnetic flux in a first direction and a second magnetic state with a magnetic flux in a second direction. The transformer cores retain the first magnetic state and the second magnetic state without current flow through said plurality of transformers. Circuitry is utilized for switching a selected transformer core between the first and second magnetic states to sense voltage and/or balance particular cells or particular banks of cells.