Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “intentional islanding”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Reinforcement Learning for Intentional Islanding in Resilient Power Transmission Systems

Intentional islanding is the process of identifying and deliberately decomposing the transmission network to form self-sustained islands from an endangered network during disruptions to improve resilience and security. Most existing intentional islanding models are offline resilience decision tools and hence do not provide outage responses in a timely manner. In this paper, a reinforcement learning (RL) based model for intentional islanding is developed, which offers real-time switching control, online deployability, and adaptability to varying system conditions. The intentional islanding process is formulated as a Markov decision process, where the optimal transmission switching policy is learned using the RL approach. The control policy is learned over an environment that encompasses a Power System Simulator for Engineering (PSS/E) model of the transmission network, facilitated by an interface to the standard openAI Gym framework. The proposed RL-based methodology aims to form stable and self-sustainable islands by ensuring voltage stability while reducing the power mismatch in the formed islands. A proximal policy optimization algorithm is designed, which is suitable for controlling the on/off status of the switches with multi-layer perceptron as value and actor networks. The effectiveness of the proposed framework in the self-recovery of the grid by island formation is applied on the modified IEEE 39-bus test network and validated by dynamic simulations.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Overview of Functional Technical Requirements for Intentional Islands

This document provides an overview of intentional islands, otherwise known as microgrids. The topics covered include common types of microgrid configurations, high level summaries of standards that address some aspect of microgrid implementation and interconnection, and a discussion of specific standards that apply during specific the islanding operational stages of parallel operation, transition to islanding, islanding operation and transition back to parallel operation.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Load Shed Recovery With Transmission Switching and Intentional Islanding Methods After (N-2) Line Contingencies

Changing power system configuration may result in load shed recovery (LSR) because topology change can provide power flow control in meshed network. Some topologies may favor generation redispatch as compared to others and can eliminate line congestion which leads to LSR. One of the known methods for topology change is called transmission switching (TS) and research conducted in the past showed that TS is an effective means of mitigating load shedding. Another method of topology control is intentional islanding (IIS). In this manuscript, we explore IIS as a potential solution for LSR. IIS based on generator coherency has been presented in literature for mitigating cascading failures. However, IIS has not been explored solely as a LSR mechanism. In this paper, we compare the LSR based on IIS with well known LSR algorithm based on TS. The comparison is performed for IEEE 39-bus system and IEEE 118- bus system. The results show that IIS has a potential to perform better than TS in terms of computational efficiency and LSR.

42 ENGINEERING↗

A Systematic Approach to Light Load Calculation for DG Un-Intentional Islanding

With the influx of distributed generation (DG) penetration, power utilities have adopted active anti-islanding protection methods to prevent an unintentional islanding condition. One commonly used protection scheme is implemented through the use of a transfer trip from the upline connected substation to the DG facility and is required when the capacity of connected DGs exceed a certain threshold of local minimum load. The threshold established by standard IEEE 1547.2-2009 states that a 3:1 minimum load to generation ratio is acceptable to ensure the DG will not sustain an unintentional island. However, the term “minimum load” is not precisely defined in any standard, and in practice, a light load value is chosen by engineers through manual methods that can be inconsistent, not representative and change drastically based on various cases. To solve this problem, this paper proposes a new light load calculation method creating consistency and better accuracy; the method has been implemented in. NET C# application and is used within Dominion Energy.

Chen, Le↗

Security Enhancements for Distributed Energy Resource Systems Interconnected with Distribution Networks: Final Technical Report

The revised IEEE 1547 Standard defines new complex communication-adjustable voltage and frequency regulation and ride-through characteristics, while maintaining the general antiislanding requirement for unintentional islanding situations. Unintentional islanding is prohibited while intentional islanding is specifically allowed, thus effectively enabling microgrid operation mode. Further, IEEE 1547-2018 Standard introduces new requirements in terms of interoperability so that the DER plant/circuit segments may be seamlessly integrated with the utility networks but at the same time become vulnerable to a cyber-attack. Traditional cybersecurity measures including encryption, authentication and role-based access control may not be fully implementable to all communication protocols specified in the IEEE 1547 Standard. Therefore, in this project we have identified, researched, implemented and tested several cyberphysical approaches that rely mostly on the behavior of the DER circuit and may help with validating the incoming command and control action potentially coming through an insecure communications channel. Additionally, we have built semantic models and communications profiles for DER facilities and have implemented lightweight IEC 61850 based publisher-subscriber GOOSE messaging mechanism, with security extensions in terms of authentication and encryption. The project proposed information models for integration into UCA OpenFMB 2.0 profiles focusing on grid code compliance.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Impact of synchronous condensers on fault location and black start in multi-inverter isolated microgrids

Synchronous condensers have been used in power systems for decades, but they are now attracting interest as a potential means for solving certain issues associated with inverter-based resources in islanded power systems. They have been extensively studied in applications to large wind farms and weak grids, but there has been very little study of synchronous condensers in intentionally-islanded systems, and especially self-healing ones. This report documents the results of an LDRD project intended to create modeling tools for use in the study of synchronous condensers in these smaller off-grid systems, and to explore synchronous condensers in this application. The results indicate that synchronous condensers have the potential to provide many benefits, but there are also several unanswered questions and technical challenges requiring further study.

24 POWER TRANSMISSION AND DISTRIBUTION↗

A two-stage service restoration method for electric power distribution systems

Improving the reliability of power distribution systems is critically important for both utilities and customers. This calls for an efficient service restoration module within a distribution management system to support the implementation of self-healing smart grid networks. Although the emerging smart grid technologies, including distributed generators (DGs) and remote-controlled switches, enhance the self-healing capability and allow faster recovery, they still pose additional complexity to the service restoration problem, especially under cold load pickup (CLPU) conditions. Herein, a novel two-stage restoration framework is proposed to generate a restoration solutions with a sequence of control actions. The first stage generates a restoration plan that supports both the traditional service restoration using feeder reconfiguration and the grid-forming DG-assisted intentional islanding methods. The second stage generates an optimal sequence of switching operations to bring the outaged system quickly to the final restored configuration. The problem is formulated as a mixed-integer linear program that incorporates system connectivity, operating constraints, and the CLPU models. It is demonstrated that on using a multi-feeder test case, the proposed framework is effective in utilizing all available resources to quickly restore the service and generate an optimal sequence of switching actions to be used by the operator to reach the desired optimal configuration.

24 POWER TRANSMISSION AND DISTRIBUTION↗

A Generalized Framework for Service Restoration in a Resilient Power Distribution System

An electric power grid is one of the complex infrastructures, and because of its complex nature, there is simply no way that outages can be completely avoided. Thus, a modern society that depends on reliable electric supply requires a resilient electric system that can recover from disruptions while integrating emerging smart grid technologies. Here, this article presents a novel approach for service restoration in a modern power distribution system with controllable switches and distributed generation (DG) resources for any kind of outage. The proposed framework supports both the traditional service restoration using feeder reconfiguration and the grid-forming DG-assisted intentional islands that are dynamically sized using algorithms based on the fault scenario, available resources, and priority of loads. The problem is formulated as a mixed-integer linear program that incorporates critical system connectivity and operating constraints. Simulations are performed to demonstrate the effectiveness of the proposed approach using a large-scale four-feeder 1069-bus three-phase unbalanced distribution test system. It is demonstrated that the framework is effective in utilizing all available resources in quickly restoring the power supply to improve resiliency during extreme events and is scalable for a large-scale unbalanced power distribution system.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Making Microgrids Work

Distributed energy resources including distributed generation and distributed storage are sources of energy located near local loads and can provide a variety of benefits including improved reliability if they are properly operated in the electrical distribution system. Microgrids are systems that have at least one distributed energy resource and associated loads and can form intentional islands in the electrical distribution systems. This paper gives an overview of the microgrid operation. Microgrid testing experiences from different counties was also provided.

14 SOLAR ENERGY↗

A Combined Repair Crew Dispatch Problem for Resilient Electric and Natural Gas System Considering Reconfiguration and DG Islanding

Resilience is an overarching concept that requires combined efforts from interdependent critical infrastructures to achieve. As the interdependence between the power system and the natural gas system grows, the roles of coordination in post-disaster repair will be unneglectable to improve the resilience of the two systems. In this paper, a combined repair crew dispatch problem for the interdependent power and natural gas systems is proposed. The repair schedule of the two systems is coordinated and co-optimized. Both power system topology reconfiguration and intentional DG islanding are modeled as operational measures to further improve the resilience of the interdependent systems. Case studies validate the effectiveness of the proposed method in reducing load shedding and repair duration, and prove that the interdependence has a significant impact on the repair sequence and crew coordination.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Stochastic Optimization for Grid Resilience. FY18 Final Technical Report

The optimal restoration problem lies at the foundation of the evaluation and improvement of resilience in power systems. In this report we present a scalable decomposition algorithm for solving this problem for realistic power systems. The algorithm has been developed in three major research threads, corresponding to the chapters in the present report. Chapter 1 studies mixed-integer programming (MIP) formulations for the requirement that each electrical island that appears after a recon guration must have at least one energized generator. We provide three alternative MIP formulations for this restriction, show their equivalence, and prove that two of them are stronger in terms of their linear programming relaxation than the formulation most commonly used in the power systems literature. Since the time to solve MIPs can vary signi cantly between equivalent formulations, we also present computational experiments on IEEE test systems for the Intentional Controlled Islanding (ICI) and the Black Start Allocation (BSA) problems. We observe that a polynomially separable, exponential in size, strong formulation yields the best performance for the BSA problem and exhibits a comparable performance to a linear in size, weak formulation for the ICI problem. Chapter 2 presents a methodology to generate mixed-integer linear approximations of the AC power ow equations governing lines, transformers (including tap regulators and phase shifters), shunt and series compensators, and consumption responsive to voltage. Our approximations are capable of capturing limitations for power grids under abnormal or uncommon operating conditions where common assumptions used in power ow relaxations may not hold. Particularly, the approximation captures overvoltages under almost no load, which is a major concern when energizing lines after a blackout. The method constructs piecewise linear approximations of the non-linear power ow equations by minimizing the squared approximation error over a subset of the feasible domain. We test the method using a realistic database for the Chilean system (1548 buses, 1114 lines, 564 transformers). The resulting approximations yield root mean square errors in the order of 0.05pu and are successfully applied to solve a transmission switching instance for the Chilean system. Chapter 3 presents our algorithm for optimal restoration. The algorithm works by partitioning the problem into a master problem and a slave problem. The master problem optimizes over energization sequences of generators, buses and branches, for the entire restoration horizon, while respecting the energization requiments studied in Chapter 1. The slave problem veri es that there exist power ow solutions supporting the energization sequences proposed by the master problem, adding cuts to the master if an infeasible sequence is detected.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Experimental Evaluation of PV Inverter Anti-Islanding with Grid Support Functions in Multi-Inverter Island Scenarios

As PV and other DER systems are connected to the grid at increased penetration levels, island detection may become more challenging for two reasons: 1.) In islands containing many DERs, active inverter-based anti-islanding methods may have more difficulty detecting islands because each individual inverter's efforts to detect the island may be interfered with by the other inverters in the island. 2.) The increasing numbers of DERs are leading to new requirements that DERs ride through grid disturbances and even actively try to regulate grid voltage and frequency back towards nominal operating conditions. These new grid support requirements may directly or indirectly interfere with anti-islanding controls. This report describes a series of tests designed to examine the impacts of both grid support functions and multi-inverter islands on anti-islanding effectiveness. Crucially, the multi-inverter anti-islanding tests described in this report examine scenarios with multiple inverters connected to multiple different points on the grid. While this so-called 'solar subdivision' scenario has been examined to some extent through simulation, this is the first known work to test it using hardware inverters. This was accomplished through the use of power hardware-in-the-loop (PHIL) simulation, which allows the hardware inverters to be connected to a real-time transient simulation of an electric power system that can be easily reconfigured to test various distribution circuit scenarios. The anti-islanding test design was a modified version of the unintentional islanding test in IEEE Standard 1547.1, which creates a balanced, resonant island with the intent of creating a highly challenging condition for island detection. Three common, commercially available single-phase PV inverters from three different manufacturers were tested. The first part of this work examined each inverter individually using a series of pure hardware resistive-inductive-capacitive (RLC) resonant load based anti-islanding tests to determine the worst-case configuration of grid support functions for each inverter. A grid support function is a function an inverter performs to help stabilize the grid or drive the grid back towards its nominal operating point. The four grid support functions examined here were voltage ride-through, frequency ride-through, Volt-VAr control, and frequency-Watt control. The worst-case grid support configuration was defined as the configuration that led to the maximum island duration (or run-on time, ROT) out of 50 tests of each inverter. For each of the three inverters, it was observed that maximum ROT increased when voltage and frequency ride-through were activated. No conclusive evidence was found that Volt-VAr control or frequency-Watt control increased maximum ROT. Over all single-inverter test cases, the maximum ROT was 711 ms, well below the two-second limit currently imposed by IEEE Standard 1547-2003. A subsequent series of 244 experiments tested all three inverters simultaneously in the same island. These tests again used a procedure based on the IEEE 1547.1 unintentional islanding test to create a difficult-to-detect island condition. For these tests, which used the two worst-case grid support function configurations from the single-inverter tests, the inverters were connected to a variety of island circuit topologies designed to represent the variety of multiple-inverter islands that may occur on real distribution circuits. The interconnecting circuits and the resonant island load itself were represented in the real-time PHIL model. PHIL techniques similar to those employed here have been previously used and validated for anti-islanding tests, and the PHIL resonant load model used in this test was successfully validated by comparing single-inverter PHIL tests to conventional tests using an RLC load bank.

24 POWER TRANSMISSION AND DISTRIBUTION↗