Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “insulation installation quality”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

DOE Residential Energy Code Field Study - Pennsylvania

This project consisted of three distinct phases – all focused on residential one- and two-family dwellings and townhouses. Phase 1 included a baseline field study with inspections and performance testing to assess construction practices with respect to the energy code. PNNL used the data to perform EUI and savings potential analyses. Phase 2 consisted of training, education, and outreach to building industry professionals with content based on the findings from Phase 1. Phase 3 was a post-program field study using the same methodology as Phase 1 and was intended to measure the impact of Phase 2. During Phase 1 of the project, PSD collected data from 171 job sites across eastern Pennsylvania, a territory bounded by PECO, PPL, and Met-Ed electric distribution territories, to reach the required 63 “home equivalents” deemed necessary by PNNL for a representative sample. Based on subsequent analysis, four key items were identified as having significant savings potential from improvement in compliance, including duct leakage, above-grade wall insulation (specifically insulation installation quality), foundation insulation, and high-efficacy lighting. About half the total savings potential is from duct leakage, so that was the primary focus. The goal of Phase 2 was to improve upon these key compliance weaknesses through an intensive training, education, and outreach program. PSD dubbed this effort the Penn Energy Codes Program. For Phase 3, PSD obtained a new sample plan from PNNL, obtained permit data from sample municipalities, and made substitutions where necessary. PSD field staff visited 165 job sites to collect the required 504 key observations. PSD submitted all data collection sheets to PNNL for their analysis to determine if there was a measurable change due to Phase 2 activities.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Installation Quality Framework: Investment Return Approach for Energy Savings on Building Product Installation

A case study was conducted on 44 residential homes using both traditional house wrap and ZIP System systems to measure the overall airtightness and compare estimated energy usages. The labor, material, and overhead and profit (O&P) costs were analyzed and used to determine the optimal choice for long-term benefits in terms of cost and performance. The impact of insulation installation is considered a key factor in improving the strategy of reducing energy consumption. Improved installation practices can affect the airtightness of common wall assemblies to reduce the building energy performance gaps and provide insight on how to allocate resources better. A framework was developed to analyze operational costs and building energy performance to address how installation quality is a factor in the return of investment in building construction for heating and cooling systems within the thermal envelope. With this methodology, aggressive energy performance goals will be met while balancing the tradeoff between installation techniques and building systems efficiency based on the introduced probabilistic investment return (PIR) metric.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Residential Building Energy Code Field Study

This document presents a methodology for assessing baseline energy efficiency in new single-family residential buildings and quantifying related savings potential. The approach was developed by Pacific Northwest National Laboratory (PNNL) for the U.S. Department of Energy (DOE) Building Energy Codes Program with the objective of assisting states as they assess energy efficiency in residential buildings and implementation of their building energy codes, as well as to target areas for improvement through energy codes and broader energy-efficiency programs. It is also intended to facilitate a consistent and replicable approach to research studies of this type and establish a transparent data set to represent baseline construction practices across U.S. states.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

A simple method for the measurement of reflective foil emissivity

Reflective metal foil is widely used to reduce radiative heat transfer within the roof space of buildings. Such foils are typically mass-produced by vapor-deposition of a thin metallic coating onto a variety of substrates, ranging from plastic-coated reinforced paper to 'bubble-wrap'. Although the emissivity of such surfaces is almost negligible in the thermal infrared, typically less than 0.03, an insufficiently thick metal coating, or organic contamination of the surface, can significantly increase this value. To ensure that the quality of the installed insulation is satisfactory, Australian building code AS/NZS 4201.5:1994 requires a practical agreed method for measurement of the emissivity, and the standard ASTM-E408 is implied. Unfortunately this standard is not a 'primary method' and requires the use of specified expensive apparatus and calibrated reference materials. At NMIA we have developed a simple primary technique, based on an apparatus to thermally modulate the sample and record the apparent modulation in infra-red radiance with commercially available radiation thermometers. The method achieves an absolute accuracy in the emissivity of approximately 0.004 (k=2). This paper theoretically analyses the equivalence between the thermal emissivity measured in this manner, the effective thermal emissivity in application, and the apparent emissivity measured in accordance with ASTM-E408.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Multifamily Air Leakage Evaluation: A Modular Case Study

The purpose of this case study is to compare the air leakage rates of modular and site-built multifamily dwelling units. The methods, materials, and equipment were observed to be very similar in the modular and site-constructed units in this case study. The installation quality of building envelope measures such as insulation and air barrier appeared to be better for modular construction, because they were installed in a controlled, factory setting. Through field observations, we identified cosmetic damage to the envelope of modular units following transport to the building site, but with no resulting significant air leakage pathways. However, we did see air leakage pathways resulting from field modifications to the envelope of modular units to accommodate structural and mechanical connections. We found that the extensive use of through-wall HVAC systems, combined with the transport, placement, and rework of modular units may compromise the high-quality envelope installation and airtightness observed in the factory without careful planning and/or design. Opportunities for improvement identified from the tested modular dwelling units include minimizing and optimally locating penetrations, pre-cutting and detailing penetrations at the factory where possible, properly sealing field modifications, and using split HVAC systems in place of through-wall packaged systems.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Deep Residential Retrofits in East Tennessee

Executive Summary Oak Ridge National Laboratory (ORNL) is furthering residential energy retrofit research in the mixed-humid climate of East Tennessee by selecting 10 homes and guiding the homeowners in the energy retrofit process. The homeowners pay for the retrofits, and ORNL advises which retrofits to complete and collects post-retrofit data. This effort is in accordance with the Department of Energy s Building America program research goal of demonstrating market-ready energy retrofit packages that reduce home energy use by 30 50%. Through this research, ORNL researchers hope to understand why homeowners decide to partake in energy retrofits, the payback of home energy retrofits, and which retrofit packages most economically reduce energy use. Homeowner interviews help the researchers understand the homeowners experience. Information gathered during the interviews will aid in extending market penetration of home energy retrofits by helping researchers and the retrofit industry understand what drives homeowners in making positive decisions regarding these retrofits. This report summarizes the selection process, the pre-retrofit condition, the recommended retrofits, the actual cost of the retrofits (when available), and an estimated energy savings of the retrofit package using EnergyGauge . Of the 10 households selected to participate in the study, only five completed the recommended retrofits, three completed at least one but no more than three of the recommended retrofits, and two households did not complete any of the recommended retrofits. In the case of the two homes that did none of the recommended work, the pre-retrofit condition of the homes and the recommended retrofits are reported. The five homes that completed the recommended retrofits are monitored for energy consumption of the whole house, appliances, space conditioning equipment, water heater, and most of the other circuits with miscellaneous electric loads (MELs) and lighting. Thermal comfort is also monitored, with temperature and humidity measured in all conditioned zones, attics, crawlspaces, and unconditioned basements. In some homes, heat flux transducers are installed on the basement walls to help determine the insulating qualities of the technologies and practices. EnergyGauge is used to estimate the pre-retrofit and post-retrofit home energy rating system (HERS) index and reduction in energy consumption and energy bill. In a follow-up report, data from the installed sensors will be presented and analyzed as well as a comparison of the post-retrofit energy consumption of the home to the EnergyGauge model of the post-retrofit home. Table ES1 shows the retrofits that were completed at the eight households where some or all of the recommended retrofits were completed. Home aliases are used to keep the homeowners anonymous. Some key findings of this study thus far are listed as follows. Some homeowners (50%) are not willing to spend the money to reach 30 50% energy savings. Quality of retrofit work is significantly variable among contractors which impact the potential energy savings of the retrofit. Challenges exist in defining house volume and floor area. Of the five homes that completed all the recommended retrofits, energy bill savings was not the main driver for energy retrofits. In no case were the retrofits cost neutral given a 15 year loan at 7% interest for the retrofit costs.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

A review of prefabricated overclad panels for building energy retrofits

Over 50% of existing buildings in the US were constructed before 1980 and lack modern, energy-efficient technologies. Despite the large number of old buildings, less than 2% of buildings are retrofitted each year with many of those retrofits consisting of small incremental improvements that often ignore the building envelope. The opaque building envelope affects 25% of building energy use equating to 10% of total US primary energy use. To meet decarbonization goals by 2035, the US must increase the rate of retrofit of existing building envelopes. The process of prefabrication is one potential opportunity to increase the rate of envelope retrofits and reduce costs. Prefabrication is the process of manufacturing construction components in a controlled environment before shipping them on-site to perform assembly of the construction. The process of prefabrication has been demonstrated to increase production efficiency, quality control, and rate of production. Prefabricated overclad panels, consisting of a cladding material and insulation designed to be installed over the existing envelope, have been successfully used to retrofit existing buildings in countries other than the US; however, the technology still has some barriers to major market adoption within the US. This paper will present a review of current implementations and demonstrations of prefabricated overclad panels. The review will include identification of panel types, materials, and applications and aims to identify barriers to retrofit market entry and widespread adoption.

Hayes, Nolan [ORNL] (ORCID:0000000332245718)↗

Manufacture and Quality Control of Insert Coil with Real ITER TF Conductor

JAEA successfully completed the manufacture of the toroidal field (TF) insert coil (TFIC) for a performance test of the ITER TF conductor in the final design in cooperation with Hitachi, Ltd. The TFIC is a single-layer 8.875-turn solenoid coil with 1.44-m diameter. This will be tested for 68-kA current application in a 13-T external magnetic field. TFIC was manufactured in the following order: winding of the TF conductor, lead bending, fabrication of the electrical termination, heat treatment, turn insulation, installation of the coil into the support mandrel structure, vacuum pressure impregnation (VPI), structure assembly, and instrumentation. Here in this presentation, manufacture process and quality control status for the TFIC manufacturing are reported.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Cold Test Facility for the ITER Central Solenoid Coils

The United States, along with the European Union, Russia, Japan, China. South Korea and India, is a collaborative partner in the design, construction and operation of the ITER International Tokamak which will be located a Cadarache, France. One component of the US in kind contribution to the project is the Central Solenoid System for the tokamak magnet system. The Central Solenoid System is a massive assembly 4.4 meters outside diameter, 18.8 meters high and weighing ~ 1,000 tons. Operating conditions (not simultaneous) are 45kA and 13 T with a maximum field ramp rate of 1.3 T/s producing a maximum flux swing of 277 V s. This combination of performance parameters make the ITER Central Solenoid one the most challenging magnet system ever built Using CICC provide by Japan, the US will deliver the final CS System by fabricating the magnet from six (6) separate 100 ton coils supported and restrained by an external structure. Part of the US responsibilities in delivering this magnet system to the ITER International Organization is to acceptance test each Central Solenoid Coil separately at operating (4K) temperature. The principal acceptance test objectives are coil leak tightness, insulation integrity and overall coil joint quality. Peak test field and test current are reduced without field contributions from adjacent coils and practical installation considerations. This paper will describe an ITER Central Solenoid Cold Test Facility study undertaken by the National High Magnetic Field Laboratory at Florida State University and the United States ITER Project Office at Oak Ridge, TN.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Demonstration of the Performance of Highly Insulating (R-5) Windows in a Matched Pair of Homes

Improving the insulation and solar heat gain characteristics of a home’s windows has the potential to significantly improve the home’s overall thermal performance by reducing heat loss (in the winter), and cooling loss and solar heat gain (in the summer) through the windows. A high-quality installation will also minimize or reduce air leakage through the building envelope, decreasing infiltration and thus contributing to reduced heat transmission through building envelope. These improvements all contribute to decreasing overall annual home energy use. In addition to improvements in energy efficiency, highly insulating windows can have important impacts on occupant comfort by minimizing or eliminating the cold draft many homeowners experience at or near window surfaces that are at a noticeably cooler than the room air temperature. Energy efficiency measures, such as highly insulating windows, also have the potential to decrease peak energy use in a home, which can lead to measurable peak load decreases for a utility service territory if implemented on a large scale. High-performance windows now feature triple-pane glass, double low-e coatings, and vinyl insulated frames to achieve U-factors as low as 0.2 , as compared to double-pane clear glass windows with a U-factor of 0.67, which are common in existing homes across the United States. The highly insulating windows (as they will be referred to in this document) are now available from several manufacturers and show promise to yield considerable energy savings and thermal comfort improvements in homes.

building energy efficiency↗

Indoor Environmental Quality Benefits of Apartment Energy Retrofits

Sixteen apartments serving low-income populations in three buildings were retrofit with the goal of simultaneously reducing energy consumption and improving indoor environmental quality (IEQ). Retrofit measures varied among apartments and included, among others, envelope sealing, installation of continuous mechanical ventilation systems, upgrading bathroom fans and range hoods, attic insulation, replacement of heating and cooling systems, and adding wall-mounted particle air cleaners. IEQ parameters were measured, generally for two one-week periods before and after the retrofits. The measurements indicate an overall improvement in IEQ conditions after the retrofits. Comfort conditions, bathroom humidity, and concentrations of carbon dioxide, acetaldehyde, volatile organic compounds, and particles generally improved. Formaldehyde and nitrogen dioxide levels decreased in the building with the highest concentrations, were unchanged in a second building, and increased in a third building. IEQ parameters other than particles improved more in apartments with continuous mechanical ventilation systems installed. In general, but not consistently, larger percent increases in air exchange rates were associated with larger percent decreases in indoor levels of the pollutants that primarily come from indoor sources.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Field Evaluation of Highly Insulating Windows in the Lab Homes: Winter Experiment

This field evaluation of highly insulating windows was undertaken in a matched pair of 'Lab Homes' located on the Pacific Northwest National Laboratory (PNNL) campus during the 2012 winter heating season. Improving the insulation and solar heat gain characteristics of a home's windows has the potential to significantly improve the home's building envelope and overall thermal performance by reducing heat loss (in the winter), and cooling loss and solar heat gain (in the summer) through the windows. A high quality installation and/or window retrofit will also minimize or reduce air leakage through the window cavity and thus also contribute to reduced heat loss in the winter and cooling loss in the summer. These improvements all contribute to decreasing overall annual home energy use. Occupant comfort (non-quantifiable) can also be increased by minimizing or eliminating the cold 'draft' (temperature) many residents experience at or near window surfaces that are at a noticeably lower temperature than the room air temperature. Lastly, although not measured in this experiment, highly insulating windows (triple-pane in this experiment) also have the potential to significantly reduce the noise transmittance through windows compared to standard double-pane windows. The metered data taken in the Lab Homes and data analysis presented here represent 70 days of data taken during the 2012 heating season. As such, the savings from highly insulating windows in the experimental home (Lab Home B) compared to the standard double-pane clear glass windows in the baseline home (Lab Home A) are only a portion of the energy savings expected from a year-long experiment that would include a cooling season. The cooling season experiment will take place in the homes in the summer of 2012, and results of that experiment will be reported in a subsequent report available to all stakeholders.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Existing Whole-House Case Study: Sunnyvale Marine Climate Deep Retrofit - Sunnyvale, California

In this project, the Building America team Alliance for Residential Building Innovation and Allen Gilliland of One Sky Homes collaborated on a marine climate retrofit project designed to meet both Passive House and Building America program standards. The scope included sealing, installing wall, roof and floor insulation (previously lacking), replacing windows, and upgrading the heating and cooling system.

ARBI↗

Sunnyvale Marine Climate Deep Retrofit

The Alliance for Residential Building Innovation (ARBI) and Allen Gilliland of One Sky Homes collaborated on a marine climate retrofit project designed to meet both Passive House (PH) and Building America (BA) program standards. The scope included sealing, installing wall, roof and floor insulation (previously lacking), replacing windows, upgrading the heating and cooling system, and installing.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Sunnyvale Marine Climate Deep Retrofit

The Alliance for Residential Building Innovation (ARBI) and Allen Gilliland of One Sky Homes collaborated on a marine climate retrofit project designed to meet both Passive House (PH) and Building America program standards. The scope included sealing, installing wall, roof and floor insulation (previously lacking), replacing windows, upgrading the heating and cooling system, and installing mechanical ventilation.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Excavationless Exterior Foundation Insulation Exploratory Study

Building science research supports installing exterior (soil side) foundation insulation as the optimal method to enhance the hygrothermal performance of new homes. With exterior foundation insulation, water management strategies are maximized while insulating the basement space and ensuring a more even temperature at the foundation wall. Controlling for bulk water, vapor, and wall temperature differential reduces the risk of rot and mold formation to insulation and building materials, thereby improving opportunities for structural integrity, indoor air quality, comfort, and energy efficiency. The intent of this study by the NorthernSTAR Building America Partnership team is to search for combinations of existing technologies that could enable a minimally invasive, cost-competitive, easily deployable method of upgrading soil-side foundation insulation in existing buildings. Currently, insulating foundation walls on the exterior side involves exposing the foundation wall using an excavator. Following excavation, these walls can be waterproofed, and are typically insulated with board foam in a process similar to new construction. This process is expensive and highly disruptive to the landscape and the homeowner. Also, barriers such as porches and sidewalks prevent trenching. An ideal approach would involve excavating a very narrow trench directly next to the foundation wall. Full-height foundation wall insulation might be desired, so the trenching technology should be able to dig to a depth of 7 or 8 ft. Because houses often have hardscape obstructions that are expensive to demolish and remove, the ideal technology would be capable of digging under at least some obstructions that would remain in place.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Determination and Assessment of Optimum Internal Thermal Insulation for Masonry Walls in Historic Multifamily Buildings

A large portion of existing building stock is comprised of load-bearing masonry buildings, particularly in the Midwest and on the East Coast, though such buildings are distributed across the US. Most of them have uninsulated walls or suffer from insufficient thermal insulation materials. These buildings are inseparable parts of the cultural, social, and economic characteristics of their cities. Due to heritage and preservation concerns, zoning, and space restrictions, they cannot be retrofitted with exterior insulation. Interior insulation must therefore be considered as an alternative. Lack of insulation directly results in energy waste as well as heat loss and gain. Furthermore, it adversely affects heating, ventilation, and air conditioning (HVAC) loads, equipment sizing, indoor air quality, and thermal comfort for residents. The objective of this study is to simulate and evaluate the effects of various internal thermal insulation materials and strategies on mass masonry load-bearing walls in multifamily buildings with attention to various variables and parameters. It not only addresses the energy performance and cost savings associated with an interior insulation retrofit, but also outlines other variables and parameters that are factors in the selection of optimum insulation material, including installations costs, payback periods, useful internal space loss, and options for the depth of the interior insulation retrofit. In conclusion, the audience for this paper is diverse: homeowners, contractors and remodelers, architects and designers, engineers, housing and preservation authorities, and more can benefit from understanding the results outlined in this study.

42 ENGINEERING↗

Akiachak Energy Efficiency Retrofit Project

The goal of the project is to reduce the overall energy use of the Akiachak Native Community (ANC) by implementing energy efficiency measures in five high-use Tribal buildings. This project will have the following outcomes: Projected annual energy savings of $17,369; projected annual reduction in fuel oil #1 of 1,200 gallons and electricity of 17,751 kWh; annual reduction in carbon dioxide emissions of approximately 60,340 pounds/year. ANC will install energy efficiency measures in the Laundry, Tribal Indian Reorganization Act (IRA) Office, Clinic, Daycare, and Police Station. ANC obtained energy audits on these buildings in 2018, and this project will implement high-payback recommendations such as replacing lighting with LEDs, installing setback thermostats and occupancy sensors, replacing furnaces with more efficient models, replacing the circulation pumps with variable speed ones, air tightening, and adding insulation. Buildings will see energy cost reductions from 15% to 40%. These retrofits will help build ANC’s long-term vision for sustainable energy usage and address the first goal of the Tribal IRA Council’s Energy Efficiency and Conservation Strategy, to “create and maintain functionally appropriate, sustainable, accessible, high quality tribal infrastructure and facilities.” ANC intends to replicate this project by using the resulting energy savings to address audit recommendations in other buildings as well as to demonstrate the value of energy efficiency to community members. Other outcomes will include an increase in community resiliency, reduced dependence on outside shipments of fuel oil, training for maintenance staff, and no-touch control of building appliances to reduce transmission of diseases such as COVID-19.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗