Resolve instrument onboard XRISM: design, integration, and instrument test results

The Resolve instrument onboard the X-Ray Imaging and Spectroscopy Mission (XRISM) consists of an array of 6 × 6 silicon-thermistor microcalorimeters cooled down to 50 mK and a high-throughput X-ray mirror assembly (XMA) with a focal length of 5.6 m. XRISM is a recovery mission of ASTRO-H/Hitomi, and the Resolve instrument is a rebuild of the ASTRO-H Soft X-ray spectrometer (SXS) and the Soft X-ray Telescope (SXT) that achieved energy resolution of ∼ 5 eV FWHM on orbit, with several important changes based on lessons learned from ASTRO-H. The flight models of the Dewar and the electronics boxes were fabricated, and the instrument test and calibration were conducted in 2021. By tuning the cryocooler frequencies, energy resolution better than 4.9 eV FWHM at 6 keV was demonstrated for all 36 pixels and high-resolution grade events, as well as energy-scale accuracy better than 2 eV up to 30 keV. The immunity of the detectors to microvibration, electrical conduction, and radiation was evaluated. The instrument was delivered to the spacecraft system in April 2022. The XMA was tested and calibrated separately. Its angular resolution is 1.27′, and the effective area of the mirror itself is 570 cm 2 at 1 keV and 424 cm 2 at 6 keV. We report the design and the major changes from the ASTRO-H SXS, the integration, and the results of the instrument test.

X-ray↗

Experimental Report: Multi-Instrument Comparison of AAF Size Distribution Instruments

Aerosols are particles suspended in the atmosphere, ranging in size from nanometers to micrometers. Their size distribution affects key atmospheric processes, including nucleation, coagulation, scavenging, activation, and radiative properties (Seinfeld and Pandis 2016). Aerosol size distribution is a critical parameter in atmospheric science, influencing processes such as cloud formation and radiative forcing. Accurate representation of aerosol size distributions is essential for understanding their impact on climate, air quality, and human health. However, aerosol size and composition vary significantly across time and space due to meteorological conditions and natural or anthropogenic sources. (Wu and Boor 2021). Various instruments are used to measure aerosol size distributions, each with distinct principles, advantages, and limitations. This report begins with an in-depth overview of aerosol size-distribution comparison studies, focusing on the passive cavity aerosol spectrometer probe (PCASP), portable optical particle spectrometer (POPS), ultra-high-sensitivity aerosol spectrometer (UHSAS), aerodynamic particle sizer (APS), and scanning mobility particle sizer (SMPS). All of these instruments are used by the U.S. Department of Energy Atmospheric Radiation Measurement (ARM) Aerial Facility (AAF), which commissioned this comparison and report. The report evaluates the strengths and weaknesses of these instruments, highlights their applications, and discusses efforts to merge data from multiple instruments for comprehensive analysis.

54 ENVIRONMENTAL SCIENCES↗

Product ion distributions using H 3 O + proton-transfer-reaction time-of-flight mass spectrometry (PTR-ToF-MS): mechanisms, transmission effects, and instrument-to-instrument variability

Abstract. Proton-transfer-reaction mass spectrometry (PTR-MS) using hydronium ion (H3O+) ionization is widely used for the measurement of volatile organic compounds (VOCs) both indoors and outdoors. H3O+ ionization, as well as the associated chemistry in an ion–molecule reactor, is known to generate product ion distributions (PIDs) that include other product ions besides the proton-transfer product. We present a method, using gas-chromatography pre-separation, for quantifying PIDs from PTR-MS measurements of nearly 100 VOCs of different functional types including alcohols, ketones, aldehydes, acids, aromatics, organohalides, and alkenes. We characterize instrument configuration effects on PIDs and find that reactor reduced electric field strength (E/N), ion optic voltage gradients, and quadrupole settings have the strongest impact on measured PIDs. Through an interlaboratory comparison of PIDs measured from calibration cylinders, we characterized the variability of PID production from the same model of PTR-MS across seven participating laboratories. Product ion variability was generally smaller (e.g., < 20 %) for ions with larger contributions to the PIDs (e.g., > 0.30) but less predictable for product ions formed through O2+ and NO+ reactions. We present a publicly available library of H3O+ PTR-MS PIDs that will be updated periodically with user-provided data for the continued investigation into instrument-to-instrument variability of PIDs.

Link, Michael F. (ORCID:0000000218412455)↗

Overview of the Instrumentation for the Dark Energy Spectroscopic Instrument

Abstract The Dark Energy Spectroscopic Instrument (DESI) embarked on an ambitious 5 yr survey in 2021 May to explore the nature of dark energy with spectroscopic measurements of 40 million galaxies and quasars. DESI will determine precise redshifts and employ the baryon acoustic oscillation method to measure distances from the nearby universe to beyond redshift z > 3.5, and employ redshift space distortions to measure the growth of structure and probe potential modifications to general relativity. We describe the significant instrumentation we developed to conduct the DESI survey. This includes: a wide-field, 3.°2 diameter prime-focus corrector; a focal plane system with 5020 fiber positioners on the 0.812 m diameter, aspheric focal surface; 10 continuous, high-efficiency fiber cable bundles that connect the focal plane to the spectrographs; and 10 identical spectrographs. Each spectrograph employs a pair of dichroics to split the light into three channels that together record the light from 360–980 nm with a spectral resolution that ranges from 2000–5000. We describe the science requirements, their connection to the technical requirements, the management of the project, and interfaces between subsystems. DESI was installed at the 4 m Mayall Telescope at Kitt Peak National Observatory and has achieved all of its performance goals. Some performance highlights include an rms positioner accuracy of better than 0.″1 and a median signal-to-noise ratio of 7 of the [O ii ] doublet at 8 × 10 −17 erg s −1 cm −2 in 1000 s for galaxies at z = 1.4–1.6. We conclude with additional highlights from the on-sky validation and commissioning, key successes, and lessons learned.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Design and instrumentation for permanent magnet samples exposed to a radiation environment

This work is part of a larger program to study the effects of radiation on permanent magnets in an accelerator environment. In order to be sure that the permanent magnet samples are accurately placed, measured, and catalogued we have developed a system of sample racks, holders and measuring apparatuses. We have combined these holders and measurement racks with electronics to allow a single computer to catalogue the position and intensity of the magnet measurements. We outline the design of the apparatus, the collection software, and the methodology we will use to collect the data.

Accelerator Physics↗

Simultaneous Measurements of Noncommuting Observables: Positive Transformations and Instrumental Lie Groups

We formulate a general program for describing and analyzing continuous, differential weak, simultaneous measurements of noncommuting observables, which focuses on describing the measuring instrument autonomously, without states. The Kraus operators of such measuring processes are time-ordered products of fundamental differential positive transformations, which generate nonunitary transformation groups that we call instrumental Lie groups. The temporal evolution of the instrument is equivalent to the diffusion of a Kraus-operator distribution function, defined relative to the invariant measure of the instrumental Lie group. This diffusion can be analyzed using Wiener path integration, stochastic differential equations, or a Fokker-Planck-Kolmogorov equation. This way of considering instrument evolution we call the Instrument Manifold Program. We relate the Instrument Manifold Program to state-based stochastic master equations. We then explain how the Instrument Manifold Program can be used to describe instrument evolution in terms of a universal cover that we call the universal instrumental Lie group, which is independent not just of states, but also of Hilbert space. The universal instrument is generically infinite dimensional, in which case the instrument’s evolution is chaotic. Special simultaneous measurements have a finite-dimensional universal instrument, in which case the instrument is considered principal, and it can be analyzed within the differential geometry of the universal instrumental Lie group. Principal instruments belong at the foundation of quantum mechanics. We consider the three most fundamental examples: measurement of a single observable, position and momentum, and the three components of angular momentum. As these measurements are performed continuously, they converge to strong simultaneous measurements. For a single observable, this results in the standard decay of coherence between inequivalent irreducible representations. For the latter two cases, it leads to a collapse within each irreducible representation onto the classical or spherical phase space, with the phase space located at the boundary of these instrumental Lie groups.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Comparison of Sub-Ppm Instrument Response Suggests Higher Detection Limits Could Be Used to Quantify Methane Emissions from Oil and Gas Infrastructure

Quantifying and controlling fugitive methane emissions from oil and gas facilities remains essential for addressing climate goals, but the costs associated with monitoring millions of production sites remain prohibitively expensive. Current thinking, supported by measurement and simple dispersion modelling, assumes single-digit parts-per-million instrumentation is required. To investigate instrument response, the inlets of three trace-methane (sub-ppm) analyzers were collocated on a facility designed to release gas of known composition at known flow rates between 0.4 and 5.2 kg CH 4 h –1 from simulated oil and gas infrastructure. Methane mixing ratios were measured by each instrument at 1 Hertz resolution over nine hours. While mixing ratios reported by a cavity ring-down spectrometer (CRDS)-based instrument were on average 10.0 ppm (range 1.8 to 83 ppm), a mid-infrared laser absorption spectroscopy (MIRA)-based instrument reported short-lived mixing ratios far larger than expected (range 1.8 to 779 ppm) with a similar nine-hour average to the CRDS (10.1 ppm). We suggest the peaks detected by the MIRA are likely caused by a micrometeorological phenomenon, where vortex shedding has resulted in heterogeneous methane plumes which only the MIRA can observe. Further analysis suggests an instrument like the MIRA (an optical-cavity-based instrument with cavity size ≤10 cm3 measuring at ≥2 Hz with air flow rates in the order of ≤0.3 slpm at distances of ≤20 m from the source) but with a higher detection limit (25 ppm) could detect enough of the high-concentration events to generate representative 20 min-average methane mixing ratios. Even though development of a lower-cost, high-precision, high-accuracy instrument with a 25 ppm detection threshold remains a significant problem, this has implications for the use of instrumentation with higher detection thresholds, resulting in the reduction in cost to measure methane emissions and providing a mechanism for the widespread deployment of effective leak detection and repair programs for all oil and gas infrastructure.

03 NATURAL GAS↗

A science-driven approach to optimize the design for a biological small-angle neutron scattering instrument

Biological small-angle neutron scattering (SANS) instruments facilitate critical analysis of the structure and dynamics of complex biological systems. However, with the growth of experimental demands and the advances in optical systems design, a new neutron optical concept is necessary to overcome the limitations of current instruments. This work presents an approach to include experimental objectives ( i.e. the science to be supported by a specific neutron scattering instrument) in the optimization of the neutron optical concept. The approach for a proposed SANS instrument at the Second Target Station of the Spallation Neutron Source at Oak Ridge National Laboratory, USA, is presented here. Further, the instrument is simulated with the McStas software package. The optimization process is driven by an evolutionary algorithm using McStas output data, which are processed to calculate an objective function designed to quantify the expected performance of the simulated neutron optical configuration for the intended purpose. Each McStas simulation covers the complete instrument, from source to detector, including realistic sample scattering functions. This approach effectively navigates a high-dimensional parameter space that is otherwise intractable; it allows the design of next-generation SANS instruments to address specific scientific cases and has the potential to increase instrument performance compared with traditional design approaches.

47 OTHER INSTRUMENTATION↗

Standard Operating Procedure for Optimal Deployment of Meteorological Instrumentation Within the Solar Radiation Research Laboratory: 2024 Edition

The objective of the National Renewable Energy Laboratory's (NREL's) Solar Radiation Research Laboratory (SRRL) is to collect and use high-quality solar radiation data sets for research leading to the widespread adoption of solar technologies. To appropriately populate and track the diverse array of instruments at the NREL-SRRL, NREL has established a Standard Operating Procedure (SOP) for optimal instrument deployment within the SRRL for both the Baseline Measurement System (BMS) and the Research Measurement System (RMS). Using best practices methodologies, the NREL-SRRL maintains a varied and extensive array of solar monitoring equipment to test, evaluate, and characterize the solar sensors used by federal and international agencies as well as the solar industry to determine the solar resource. The SOP provides the industry with guidance for solar resource assessment and is used for procedures in the long-term continuous monitoring of legacy instruments alongside state-of-the-art instruments. Based on the SOP, instruments are annually evaluated for continued deployment. Instruments that do not meet the SOP criteria are decommissioned, and new instruments that meet the criteria are deployed. Streamlining and optimizing the use of this facility ensures that the lab continues to be a world-leading solar calibration and measurement facility. This 2024 edition includes updates to the appendices to reflect the instrument changes from one year to another.

14 SOLAR ENERGY↗

Wind Energy Instrumentation Development Roadmap

The current instrumentation for observing the complex flow fields in and around wind plants struggles to match the fidelity of existing simulation tools. As a result, these measurement limitations create a hurdle for validating and assessing the quality of the wind plant numerical models. This roadmap for instrumentation development recommendations was created to offer guidance on narrowing the gap between measurement and simulation fidelity. A process was established to identify where gaps in instrumentation exist for wind energy test campaigns by analyzing the capabilities of instrumentation for capturing the various important phenomena at the necessary resolution for both the science goal and validation objectives. To this end, a multi-disciplinary team of experts on instrumentation, wind energy, and atmospheric science was assembled to identify these significant instrumentation needs. A recommendation for instrumentation to be developed is provided, and the framework developed through this process is expected to be useful to the design of future test campaigns. The mapping tools developed for this process will be distributed as part of a future International Energy Agency Wind Technology Collaboration Program task on instrumentation development.

17 WIND ENERGY↗

An interlaboratory comparison of mid-infrared spectra acquisition: Instruments and procedures matter

Diffuse reflectance spectroscopy has been extensively employed to deliver timely and cost-effective predictions of a number of soil properties. However, although several soil spectral laboratories have been established worldwide, the distinct characteristics of instruments and operations still hamper further integration and interoperability across mid-infrared (MIR) soil spectral libraries. In this study, we conducted a large-scale ring trial experiment to understand the lab-to-lab variability of multiple MIR instruments. By developing a systematic evaluation of different mathematical treatments with modeling algorithms, including regular preprocessing and spectral standardization, we quantified and evaluated instruments' dissimilarity and how this impacts internal and shared model performance. We found that all instruments delivered good predictions when calibrated internally using the same instruments' characteristics and standard operating procedures by solely relying on regular spectral preprocessing that accounts for light scattering and multiplicative/additive effects, e.g., using standard normal variate (SNV). When performing model transfer from a large public library (the USDA NSSCKSSL MIR library) to secondary instruments, good performance was also achieved by regular preprocessing (e. g., SNV) if both instruments shared the same manufacturer. However, significant differences between the KSSL MIR library and contrasting ring trial instruments responses were evident and confirmed by a semi-unsupervised spectral clustering. For heavily contrasting setups, spectral standardization was necessary before transferring prediction models. Non-linear model types like Cubist and memory-based learning delivered more precise estimates because they seemed to be less sensitive to spectral variations than global partial least square regression. In summary, the results from this study can assist new laboratories in building spectroscopy capacity utilizing existing MIR spectral libraries and support the recent global efforts to make soil spectroscopy universally accessible with centralized or shared operating procedures.

58 GEOSCIENCES↗

Standard Operating Procedure for Optimal Deployment of Meteorological Instrumentation Within the Solar Radiation Research Laboratory: 2025 Edition

The objective of the National Renewable Energy Laboratory's (NREL's) Solar Radiation Research Laboratory (SRRL) is to collect and use high-quality solar radiation data sets for research leading to the widespread adoption of solar technologies. To appropriately populate and track the diverse array of instruments at the NREL-SRRL, NREL has established a Standard Operating Procedure (SOP) for optimal instrument deployment within the SRRL for both the Baseline Measurement System (BMS) and the Research Measurement System (RMS). Using best practices methodologies, the NREL-SRRL maintains a varied and extensive array of solar monitoring equipment to test, evaluate, and characterize the solar sensors used by federal and international agencies as well as the solar industry to determine the solar resource. The SOP provides the industry with guidance for solar resource assessment and is used for procedures in the long-term continuous monitoring of legacy instruments alongside state-of-the-art instruments. Based on the SOP, instruments are annually evaluated for continued deployment. Instruments that do not meet the SOP criteria are decommissioned, and new instruments that meet the criteria are deployed. Streamlining and optimizing the use of this facility ensures that the lab continues to be a world-leading solar calibration and measurement facility. This 2025 edition includes updates to the appendices to describe the current instrumentation of the NREL-SRRL.

14 SOLAR ENERGY↗

Overview on Shielding Analyses for the VENUS Instrument at SNS

VENUS, a world‐class versatile neutron imaging instrument, is under construction and is expected to be completed and ready to start commissioning in 2023. The range of cold to epithermal neutrons at SNS will give users of VENUS access to novel imaging methods, as well as to significantly improved existing methods. The instrument is being built on beam line 10 at Spallation Neutron Source (SNS) First Target Station (FTS) facing a decoupled poisoned hydrogen moderator. Instrument design, which includes optics, Front-End components and instrument enclosure components and shape started over 10 years ago and during this time had significant changes. All changes were supported by neutronics analyses to provide adequate shielding for both Front-End and instrument enclosure.Final optics design will provide the field of view (FOV) at the detector position (where the image is formed) to be as high as 0.20 by 0.20 m. Both the beam, which contains a large fraction of high-energy neutrons, and the desire for a large footprint on the detector are challenges for shielding design and budget, because the driving cost for the instrument is the beam line and enclosure shielding. For cost reason VENUS baseline design is optimized with respect to both the instrument cave footprint and its wall thickness, and Front-End shielding is tailored along the beam. Analyses are performed with the Monte Carlo particle transport code MCNPX version 2.7.0 to make choices on materials, thicknesses and configurations of the shielding. Numerous calculations are performed to meet space and coast constrain and to satisfy instrument physics needs and to comply with radiation protection requirements.

Gallmeier, Franz X.↗

Assessment of Nuclear Sensors and Instrumentation Maturity in Advanced Nuclear Reactors

In the last decade, 97% of the worldwide commercial nuclear reactors connected to the grid were Light Water Reactors (LWRs). LWRs are expected to stay the dominant type of nuclear reactors for the next few decades. Reliable and redundant safety systems are required in nuclear reactors to ensure safe operation and shutdown in abnormal conditions. These safety systems are actuated by the signals obtained from several sensors and instrumentation in and out of the reactor core. Research and Development (R&D) in advanced sensors and instrumentation has gained extra attention, particularly following the accident at the Three Mile Island Unit-2 (TMI-2). In LWRs, these sensors and instrumentation have shown a high level of maturity with long operating experience. Ensuring the compatibility of these sensors and instrumentation with advanced nuclear reactors (Generation IV) is necessary, particularly with the expected expansion of the nuclear industry in the next few decades. Nuclear Sensor and instrumentation technologies used in the current generation of LWRs were investigated. The compatibility of these technologies with advanced reactors was assessed by comparing the advanced reactors' environments with those of the currently operating reactors. In addition to that, the needed R&D for such technologies was highlighted. In comparison with the LWRs environment, it was shown that advanced reactor environments are expected to experience elevated temperatures, a fast neutron spectrum, and a harsh corrosion environment. It was demonstrated that R&D is required mainly for fixed in-core nuclear sensors and instrumentation, while it is not a priority for ex-core nuclear sensors and instrumentation.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Standard Operating Procedure for Optimal Deployment of Meteorological Instrumentation Within the Solar Radiation Research Laboratory (BMS and RMS SOP)

The objective of the National Renewable Energy Laboratory's (NREL's) Solar Radiation Research Laboratory (SRRL) is to collect and use high-quality solar radiation data sets for research leading to the widespread adoption of solar technologies. To appropriately populate and track the diverse array of instruments at the NREL-SRRL, NREL has established a Standard Operating Procedure (SOP) for optimal instrument deployment within the SRRL for both the Baseline Measurement System (BMS) and the Research Measurement System (RMS). Using best practices methodologies, the NREL-SRRL maintains a varied and extensive array of solar monitoring equipment to test, evaluate, and characterize the solar sensors used by federal and international agencies as well as the solar industry to determine the solar resource. The SOP provides the industry with guidance for solar resource assessment and is used for procedures in the long-term continuous monitoring of legacy instruments alongside state-of-the-art instruments. Based on the SOP, instruments are annually evaluated for continued deployment. Instruments that do not meet the SOP criteria are decommissioned, and new instruments that meet the criteria are deployed. Streamlining and optimizing the use of this facility ensures that the lab continues to be a world-leading solar calibration and measurement facility.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Infrared Cloud Imager Instrument Intercomparison Report

The Infrared Cloud Imager Instrument Intercomparison was a guest instrument deployment by NWB Sensors to the U.S. Department of Energy’s Atmospheric Radiation Measurement (ARM) User Facility observatory on the Southern Great Plains (SGP) between May 18 and December 12, 2023. NWB Sensors is a company that has developed a commercially available infrared cloud imager (ICI). The ICI provides radiometrically calibrated, full-sky images of the downwelling infrared radiance in the 7.3-14 µm band. In addition, it provides cloud radiance as the residual between the observed radiance and the modeled cloud-free radiance as well as derived cloud products. The instrument is used in applications that require consistent detection of clouds across day and night. For more information, consult the instrument's webpage. The primary goal of the deployment was to validate the radiometric accuracy of the ICI. The ICI uses a proprietary calibration method to convert the raw data from its infrared camera into downwelling radiance. Unlike similar instruments, the system does not have an onboard blackbody calibration standard. Instead, NWB Sensors characterizes each ICI camera individually in an environmental chamber while looking at a blackbody standard. The resulting (proprietary) calibration is used operationally in the instrument and has been demonstrated to be stable over long periods. To validate the radiometric products from the ICI, an intercomparison between the ICI data products and those from ARM’s atmospheric emitted radiance interferometer (AERI) was made. The AERI is a best-in-class instrument for measuring downwelling infrared radiance (Gero et al. 2025). A weighted integration of the AERI’s spectral radiances across the ICI’s camera response was performed. The resulting radiance (herein called the AERI radiance) was directly compared to the zenith radiance concurrently observed by the ICI. The results of these comparisons are reported in the next section of this report.

54 ENVIRONMENTAL SCIENCES↗