Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “instrument transmissions”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Feasibility study of a compact neutron resonance transmission analysis instrument

Neutron Resonance Transmission Analysis (NRTA) uses resonant absorption of neutrons to infer the absolute isotopic composition of a target object, enabling applications in a broad range of fields such as archaeology, enrichment analysis of nuclear fuel, and arms control treaty verification. In the past, NRTA involved large user facilities and complex detector systems. However, recent advances in the intensity of compact neutron sources have made compact neutron imaging designs increasingly feasible. This work describes the Monte Carlo (MC) based design of a compact epithermal NRTA radiographic instrument which uses a moderated, compact deuterium-tritium (DT) neutron source and an epithermal neutron detector. Such an instrument would have a wide range of applications, and would be especially impactful for such scenarios as nuclear inspection and arms control verification exercises, where system complexity and mobility may be of critical importance. The MC simulations presented in this work demonstrate accurate time-of-flight (TOF) reconstructions for transmitted neutron energies, capable of differentiating isotopic compositions of nuclear material with high levels of accuracy. A new generation of miniaturized and increasingly more intense neutron sources will allow this technique to achieve measurements with greater precision and speed, with significant impact on a variety of engineering and societal problems.

47 OTHER INSTRUMENTATION↗

Surface science insight note: Optimizing XPS instrument performance for quantification of spectra

X-ray photoelectron spectroscopy (XPS) provides quantitative information from photoemission peaks and shapes observed within the background due to the inelastic scattering of photoelectrons. To quantify the signal, both photoemission peaks and background in spectra must be adjusted for instrumental transmission variations that are a consequence of changes in efficiency when recording electrons with different kinetic energy. While it is generally assumed that correcting spectroscopic data for transmission is a necessary part of quantification by XPS, there are consequences for the quantification of spectra measured using an instrument for which transmission has significant curvature. In this Insight, the implications of curvature in transmission characteristics are discussed and a method based on XPS microscopy is proposed that ensures the transmission response of an instrument is free from significant curvature. An example of an instrument for which a flat transmission response is presented is achieved through collecting spectra using lens modes designed to measure stigmatic images.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Analysis of useful ion yield for Si in GaN by secondary ion mass spectrometry

The optimum detection levels that can be achieved by a secondary ion mass spectrometer are dependent on how efficiently a particular species of interest can be ionized and detected. One can determine in advance whether the analysis of a particular ion in the sample is possible, if the useful ion yield is known. The useful ion yield depends on the element, instrument transmission, the analytical conditions, the sample matrix, etc. The value of the useful ion yield for a species can diverge from one instrument type to another due to its different transmission and ionization probabilities. However, the same tendencies in the results may be expected for all types of instruments. In this paper, the authors present a quantitative secondary ion mass spectrometry analysis of the useful ion yield for the silicon dopant species in a gallium nitride matrix grown by metal organic chemical vapor deposition. Positively ionized cesium was used as the primary ion beam, and its energy was varied in the range from 0.5 to 5 kV. A quadrupole mass analyzer was utilized to collect secondary ion species of interest. The analysis results can be used to determine the primary beam energies for optimal Si sensitivity.

Senevirathna, M. K. Indika (ORCID:0000000243575029↗

Mock data sets for the Eboss and DESI Lyman-α forest surveys

We present a publicly-available code to generate sets of mock Lyman-α (Lyα) forest data that have realistic large-scale correlations including those due to the Baryonic Acoustic Oscillations (BAO). The primary purpose of these mocks is to test the analysis procedures of the Extended Baryon Oscillation Survey (eBOSS) and the Dark Energy Spectroscopy Instrument (DESI) surveys. The transmitted flux fraction, F(λ), of background quasars due to Lyα absorption in the intergalactic medium (IGM) is simulated using the Fluctuating Gunn-Petterson Approximation (FGPA) applied to Gaussian random fields produced through the use of fast Fourier transforms (FFT). The output includes the IGM-Lyα transmitted flux fraction along quasar lines of sight and a catalog of high-column-density systems appropriately placed at high-density regions of the IGM. This output serves as input to additional code that superimposes the IGM tranmission on realistic quasar spectra, adds absorption by high-column-density systems and metals, and simulates instrumental transmission and noise. Redshift space distortions (RSD) of the flux correlations are implemented by including the large-scale velocity-gradient field in the FGPA resulting in a correlation function of F(λ) that can be accurately predicted. One hundred realizations have been produced over the 14,000 deg 2 DESI survey footprint with 100 quasars per deg 2 . The analysis of these realizations shows that the correlations of F(λ) follows the prediction within the accuracy of eBOSS survey. Here, the most time-consuming part of the mock production occurs before application of the FGPA, and the existing pre-FGPA forests can be used to easily produce new mock sets with modified redshift-dependent bias parameters or observational conditions.

79 ASTRONOMY AND ASTROPHYSICS↗

Accuracy limitations for composition analysis by XPS using relative peak intensities: LiF as an example

Although precision in XPS can be excellent, allowing small changes to be easily observed, obtaining accurate absolute elemental composition of a solid material from relative peak intensities is generally much more problematical, involving many factors: background removal; differing analysis depths at different photoelectron kinetic energies; possible angular distribution effects; calibration of the instrument transmission function, and variations of the distribution of the photoelectron intensity between “main” peaks (those usually used for analysis) and associated substructure following the main peak, as a function of the chemical bonding of the elements concerned. The last item, coupled with the use of photoionization cross-sections and/or relative sensitivity factors, is the major subject of this paper, though it is necessary to consider the other items also, using LiF as a test case. The results show that the above issues, which are relevant to differing degrees in most XPS analyses, present significant challenges to highly accurate XPS quantification.

Brundle, Christopher R.↗

New capability for neutron transmission measurements at LANSCE: The DICER instrument

A new capability for neutron transmission measurements has been developed at the Los Alamos Neutron Science Center (LANSCE). The DICER (Device for Indirect Capture Experiments on Radionuclides) instrument is designed to tightly constrain neutron-capture cross sections for short-lived radionuclides that are beyond the reach of direct techniques, via measurement and analysis of neutron transmission resonances on these same radionuclides. The innovative DICER apparatus enables simultaneous sample-in and sample-out measurements, thus minimizing the amount of sample material needed and reducing the measurements time by half. A description of the current status of the new transmission station, along with a performance overview and results from known reactions, will be presented here.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Product ion distributions using H 3 O + proton-transfer-reaction time-of-flight mass spectrometry (PTR-ToF-MS): mechanisms, transmission effects, and instrument-to-instrument variability

Abstract. Proton-transfer-reaction mass spectrometry (PTR-MS) using hydronium ion (H3O+) ionization is widely used for the measurement of volatile organic compounds (VOCs) both indoors and outdoors. H3O+ ionization, as well as the associated chemistry in an ion–molecule reactor, is known to generate product ion distributions (PIDs) that include other product ions besides the proton-transfer product. We present a method, using gas-chromatography pre-separation, for quantifying PIDs from PTR-MS measurements of nearly 100 VOCs of different functional types including alcohols, ketones, aldehydes, acids, aromatics, organohalides, and alkenes. We characterize instrument configuration effects on PIDs and find that reactor reduced electric field strength (E/N), ion optic voltage gradients, and quadrupole settings have the strongest impact on measured PIDs. Through an interlaboratory comparison of PIDs measured from calibration cylinders, we characterized the variability of PID production from the same model of PTR-MS across seven participating laboratories. Product ion variability was generally smaller (e.g., < 20 %) for ions with larger contributions to the PIDs (e.g., > 0.30) but less predictable for product ions formed through O2+ and NO+ reactions. We present a publicly available library of H3O+ PTR-MS PIDs that will be updated periodically with user-provided data for the continued investigation into instrument-to-instrument variability of PIDs.

Link, Michael F. (ORCID:0000000218412455)↗

Study of 149 Sm Capture and Total Cross Sections for Burnup Credit Applications [Slides]

This presentation highlights how capture and transmission measurements were performed with the DANCE (Detector for Advanced Neutron Capture Experiments) instrument with capture data from 8 eV – 1 keV, and DICER (Device for Indirect Capture Experiments on Radionuclides) instruments with transmission data from 1meV – 1 keV. There were additional measurements of 147 Sm which had contaminant in the samples, 3.4 eV strong resonance, interesting abnormalities. The data analysis is complete and the R-Matrix analysis almost (90%) complete.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Hubble WFC3 Spectroscopy of the Habitable-zone Super-Earth LHS 1140 b

Atmospheric characterization of temperate, rocky planets is the holy grail of exoplanet studies. These worlds are at the limits of our capabilities with current instrumentation in transmission spectroscopy and challenge our state-of-the-art statistical techniques. Here we present the transmission spectrum of the temperate super-Earth LHS 1140b using the Hubble Space Telescope (HST). The Wide Field Camera 3 (WFC3) G141 grism data of this habitable-zone (T {sub eq} = 235 K) super-Earth (R = 1.7 R {sub ⊕}) shows tentative evidence of water. However, the signal-to-noise ratio, and thus the significance of the detection, is low and stellar contamination models can cause modulation over the spectral band probed. We attempt to correct for contamination using these models and find that, while many still lead to evidence for water, some could provide reasonable fits to the data without the need for molecular absorption although most of these cause features in the visible ground-based data which are nonphysical. Future observations with the James Webb Space Telescope would be capable of confirming, or refuting, this atmospheric detection.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Feasibility and Prospects of the High Resolution Rapid Refresh Model For Dynamic Line Rating

The ampacity of transmission lines is defined as the maximum amount of current the conductor can safely carry. It is necessary for transmission line operators to apply ampacity limits due to the thermal properties of the conductor. Dynamic Line Rating (DLR) is a technology and technique that uses the environmental conditions or a set of the conditions to calculate the ampacity of the conductor. The way the DLR is calculated has depended upon some amount of physical technology to implement the solution. The High Resolution Rapid Refresh (HRRR) Model is an atmospheric model that may provide enough resolution to perform dynamic line rating without any hardware at all. The objective is to use this model to perform Dynamic Line Rating. This will solve two of the most pervasive problems in Dynamic Line Rating, how to instrument a transmission line hundreds of miles long and then how to predict near future ampacity sufficient for transmission operators to effectively use, This technique will use the Idaho National Laboratory site as the test location for analysis. The High Resolution Rapid Refresh model is a reliable, freely available, and well-maintained weather forecasting model for the entire United States of America. The model provides enough special resolution that additional local weather monitoring devices at location are not necessary to conduct dynamic line rating. The HRRR ratings are lower on average than the locally measured ratings which allows for an additional margin of safety. The adoption of using purely digital methods for dynamic line rating could allow for wide scale adoption of the technology with very little overhead expenditure of implementation.

17 WIND ENERGY↗

BEACON—automated aberration correction for scanning transmission electron microscopy using Bayesian optimization

Aberration correction is an important aspect of modern high-resolution scanning transmission electron microscopy. Most methods of aligning aberration correctors require specialized sample regions and are unsuitable for fine-tuning aberrations without interrupting on-going experiments. Here, we present an automated method of correcting first- and second-order aberrations called BEACON, which uses Bayesian optimization of the normalized image variance to efficiently determine the optimal corrector settings. We demonstrate its use on gold nanoparticles and a hafnium dioxide thin film showing its versatility in nano- and atomic-scale experiments. BEACON can correct all first- and second-order aberrations simultaneously to achieve an initial alignment and first- and second-order aberrations independently for fine alignment. Ptychographic reconstructions are used to demonstrate an improvement in probe shape and a reduction in the target aberration.

techniques and instrumentation↗

In situ electron microscopy: atomic-scale dynamics of metal oxidation and corrosion

Corrosion degrades metals through complex microscopic processes that traditional methods often fail to capture. In-situ transmission electron microscopy (TEM) bridges this gap by providing real-time atomic-scale imaging of oxidation and corrosion dynamics. Gas-phase TEM uncovers critical oxidation mechanisms like oxide nucleation and alloying effects, while liquid-phase TEM tracks corrosion initiation. Coupled with emerging techniques like ultrafast direct electron detection cameras, these advancements promise unprecedented resolution in understanding material degradation.

36 MATERIALS SCIENCE↗

Spatial resolution in secondary-electron microscopy

Here, we first review the significance of resolution and contrast in electron microscopy, and the effect of the electron optics on these two quantities. We then outline the physics of the generation of secondary electrons (SE) and their transport and emission from the surface of a specimen. Contrast and resolution are discussed for different kinds of SE imaging in scanning (SEM) and scanning-transmission (STEM) instruments, with some emphasis on the observation of individual atoms and atomic columns in a thin specimen. The possibility of achieving atomic resolution from a bulk specimen at SEM energies is also considered.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

New capability for indirect neutron capture measurements: The DICER instrument at LANSCE

The Device for Indirect Capture on Radionuclides (DICER) implements a new indirect technique for (n,γ) studies in which the neutron capture rate is determined from analysis of resonance neutron transmission data. The DICER instrument and associated radionuclide production at the Isotope Production Facility (IPF), both at the Los Alamos Neutron Science Center (LANSCE), as well radioactive sample fabrication, have been under development in the last few years. First measurements on a radioactive sample ( 88 Zr, t ½ =83.4 days), which was recently reported to have an extremely large thermal neutron capture cross section and resonance integral, are planned for the winter of 2021. A performance overview, brief details on the 88Zr fabrication and proof of good operation results will be presented.

47 OTHER INSTRUMENTATION↗

Ex situ calibration of the scattered-light time-history diagnostic on the National Ignition Facility

The scattered-light time-history diagnostic (SLTD) suite measures time-resolved scattered light in three wavelength bands: stimulated Brillouin scattering (350–352 nm), stimulated Raman scattering (430–760 nm), and plasma emission at half the laser frequency (695–735 nm), at 15 locations around the National Ignition Facility (NIF) target chamber. The SLTD, along with the full-aperture backscatter station (FABS), collects scattered light from direct- and indirect-drive inertial confinement fusion experiments. The SLTD calibration was revisited after a discrepancy between FABS and SLTD measurements was observed on NIF polar direct-drive experiments. An integrated calibration of the SLTD was performed for the first time, and individual components were also calibrated for the wavelengths of 351, 527, and 532 nm. The optical transmission of the instrument was measured to be (1.12 ± 0.04) × 10 –7 and (1.96 ± 0.11) × 10 –7 for the wavelengths of 351 and 532 nm, respectively. The revised calibration at 351 nm brings the SLTD measured scattered energy in agreement with the FABS measured scattered energy after additionally accounting for the degradation of an optical element in FABS. Furthermore, this decreased the inferred absorption by 7% for a representative experiment. However, discrepancies remain between FABS and SLTD measurements in the SRS band (532 nm).

47 OTHER INSTRUMENTATION↗

Air attenuation of high power XFEL beams

The Linac Coherent Light Source-II, a high-repetition-rate x-ray free electron laser, produces high average power as well as high peak power. Air is a key radiation safety element, helping to contain the FEL beams from reaching accessible areas. At high average power, air absorption can produce a high temperature and low-density channel along the x-ray beam path. In this case, the x-ray attenuation no longer follows the Beer-Lambert equation, e-μx . Air attenuation measurements were performed with x-rays focused into a gas cell at the LCLS Time-resolved AMO instrument. The air transmission was observed to significantly increase with x-ray power. Simulations were also performed, which include the thermal processes related to the high average power. In comparison to the measurements, the calculated air transmission is higher, confirming that the simulations are conservative and suitable for radiation safety analyses.

42 ENGINEERING↗