Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “instrument transmissions”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

White-light Interferometry using a Channeled Spectrum: II. Calibration Methods, Numerical and Experimental Results

In the companion paper, [Appl. Opt. 46, 5853 (2007)] a highly accurate white light interference model was developed from just a few key parameters characterized in terms of various moments of the source and instrument transmission function. We develop and implement the end-to-end process of calibrating these moment parameters together with the differential dispersion of the instrument and applying them to the algorithms developed in the companion paper. The calibration procedure developed herein is based on first obtaining the standard monochromatic parameters at the pixel level: wavenumber, phase, intensity, and visibility parameters via a nonlinear least-squares procedure that exploits the structure of the model. The pixel level parameters are then combined to obtain the required 'global' moment and dispersion parameters. The process is applied to both simulated scenarios of astrometric observations and to data from the microarcsecond metrology testbed (MAM), an interferometer testbed that has played a prominent role in the development of this technology.

phase correction↗

A discussion of some proposed measurement techniques for hypersonic flight and instrumentation research experiments

Sensors, instrumentation, and test techniques proposed for the Hypersonic Flight Instrumentation and Research Experiment are discussed. The project is concerned with Mach 4 to 16 flight at pressure altitudes of 50,000 to 150,000 feet. The developmental instrumentation for the program includes angle-of-attack sensors, transition sensors, skin-friction sensors, particle sensors, species-concentration sensors, and temperature and heat flux sensors. Support instrumentation (required to monitor basic flight parameters and to supply data from which the performance of the developmental instruments may be evaluated) considered include surface pressure sensors, inertial instrumentation, magnetic attitude sensors, and signal conditioning and data transmission instrumentation.

Hellbaum, R. F.↗

Intercomparisons of Airborne Measurements of Aerosol Ionic Chemical Composition during TRACE-P and ACE-Asia

As part of the two field studies, Transport and Chemical Evolution over the Pacific (TRACE-P), and the Asian Aerosol Characterization Experiment (ACEAsia), the inorganic chemical composition of tropospheric aerosols was measured over the western Pacific from three separate aircraft using various methods. Comparisons are made between the rapid online techniques of the Particle Into Liquid Sampler (PILS) for measurement of a suite of fine particle ionic compounds and a mist chamber (MC/IC) measurement of fine sulfate, and the longer time-integrated filter and multi-orifice impactor (MOI) measurements. Comparisons between identical PILS on two separate aircraft flying in formation showed that they were highly correlated (e.g., sulfate r(sup 2) of 0.95), but were systematically different by 10 +/- 5% (linear regression slope and 95% confidence bounds), and had generally higher concentrations on the aircraft with a low turbulence inlet and shorter inlet-to-instrument transmission tubing. Comparisons of PILS and mist chamber measurements of fine sulfate on two different aircraft during formation flying had an 3 of 0.78 and a relative difference of 39% +/- 5%. MOI ionic data integrated to the PILS upper measurement size of 1.3 pm sampling from separate inlets on the same aircraft showed that for sulfate, PILS and MOI were within 14% +/- 6% and correlated with an r(sup 2) of 0.87. Most ionic compounds were within f 30%, which is in the range of differences reported between PILS and integrated samplers from ground-based comparisons. In many cases, direct intercomparison between the various instruments is difficult due to differences in upper-size detection limits. However, for this study, the results suggest that the fine particle mass composition measured from aircraft agree to within 30-40%.

Ma, Y.↗

Systems Engineering of a Nuclear-Electric Spacecraft

Studies have shown that nuclear-electric propulsion systems will provide superior payload capability and unique advantages over chemical systems for high-energy deep-space missions. Conceptual design studies of unmanned spacecraft employing nuclear-electric propulsion systems have been undertaken to determine some of the major integration problems. Early recognition of these problems will help to stimulate the development effort that will be required to bring these systems into fruitful utilization. Typical designs under consideration for interplanetary missions for the next decade employ a nuclear reactor providing thermal energy to a turbogeneration system which, in turn, supplies electrical power to an ion engine for primary propulsion and additional utility power for guidance and control, powered-flight radio transmission, instrumentation, et cetera. The major systems and components which form a complete spacecraft are listed in this Report, and a review of the significant physical and operational characteristics of these various systems and components which affect spacecraft integration is made. Conceptual.configurations and detailed weight studies for a 60-kilowatts-electric Venus-capture spacecraft and a 1-megawattelectric Jupiter-capture spacecraft are shown to illustrate typical physical arrangements based on the various hardware constraints. From these configurations, the major development goals are ascertained and summarized.

SPACECRAFT↗

The DELTA MONSTER: An RPV designed to investigate the aerodynamics of a delta wing platform

The mission requirements for the performance of aerodynamic tests on a delta wind planform posed some problems, these include aerodynamic interference; structural support; data acquisition and transmission instrumentation; aircraft stability and control; and propulsion implementation. To eliminate the problems of wall interference, free stream turbulence, and the difficulty of achieving dynamic similarity between the test and actual flight aircraft that are associated with aerodynamic testing in wind tunnels, the concept of the remotely piloted vehicle which can perform a basic aerodynamic study on a delta wing was the main objective for the Green Mission - the Delta Monster. The basic aerodynamic studies were performed on a delta wing with a sweep angle greater than 45 degrees. These tests were performed at various angles of attack and Reynolds numbers. The delta wing was instrumented to determine the primary leading edge vortex formation and location, using pressure measurements and/or flow visualization. A data acquisition system was provided to collect all necessary data.

Connolly, Kristen↗

Precision X-band Doppler and ranging navigation for current and future Mars exploration missions

This paper describes a navigation error covariance analysis of two scenarios derived from the Mars Observer mission and the planned Mars Environmental SURvey (MESUR) Pathfinder mission, respectively. The analysis was performed to establish the potential navigational performance of the X-band tracking system in NASA's Deep Space Network, and to evaluate the sensitivity of the predicted performance to variations in the quantity of data acquired, the ground system error modeling assumptions, and data reduction schemes. The simulated data arcs used in the analysis are representative of the actual data arcs that will be used to predict the aim point for the Mars orbit insertion maneuver, in the case of Mars Observer, and the interplanetary trajectory aim point corresponding to the target Mars landing site in the case of MESUR Pathfinder. The results indicate that with a suitable sequential data reduction scheme and accurate calibrations of instrumentation, transmission media, and platform model parameters, navigation accuracies of 5 to 15 km (1 sigma) can be achieved, equivalent to 15 to 40 nrad in geocentric angle uncertainty.

Estefan, Jeffrey A.↗

A New Diagnostic Technique for the Solar Corona

Over the last 30-40 years spectroscopic observation of the EUV (extreme ultraviolet) line emission has proved invaluable as a diagnostic of the solar coronal plasma state. Line ratios have been used to determine electron density, electron temperature and ion flow velocity. In this paper, we present results obtained with a new measurement technique that uses spectroscopic observations of the white light corona to obtain the electron density, temperature, and flow velocity. A prototype instrument has been designed and built to obtain visible light spectra (3800-4300 A) with modest resolution. This instrument was used to obtain coronal observations during the June 2001 eclipse in Zambia. The data were corrected for sky and instrument transmission to derive the electron temperature and flow speed. Results from these measurements will be discussed.

Nelson, R.↗

Long term variability of transmission of thin In-Sn and Sn-C films for EUV instrumentation

The transmission variability is reported for two filters in the EUV, where the filters were supported on an 80% transmission nickel mesh and fabricated by means of a vacuum deposition technique. The first film consisted of 2500 A-thick indium, deposited on 500 A-thick tin, and had its primary bandpass in the 740-960 A range. The second consisted of 1800 A-thick tin and 2000 A-thick carbon, with a bandpass of 500-750 A. At the end of 10 months, the transmission of both filters was measured to check variations. It is demonstrated that the EUV transmission of such filters can change over the typical lifetime of satellite missions, and that such variation depends on the storage environment. The use of vacuum, rather than dry nitrogen storage is recommended.

Chakrabarti, S.↗

Skylab consolidated instrumentation plan for SL-1/SL-2

The consolidated instrumentation plan is presented for employing optical and electronic data acquisition systems to monitor the performance and trajectory of Skylab 1 and Skylab 2 vehicles during the launch phase. Telemetry, optical, and electronic tracking equipment on board the vehicles, and data acquisition systems monitoring the flights are discussed. Flight safety instrumentation, vehicle data transmission systems, and instrumentation geography are also described.

Clark, D. E.↗

Alignment and Performance of the Infrared Multi-Object Spectrometer

The Infrared Multi-Object Spectrometer (IRMOS) is a principle investigator class instrument for the Kitt Peak National Observatory 4 and 2.1 meter telescopes. IRMOS is a near-IR (0.8 - 2.5 micron) spectrometer with low-to mid-resolving power (R = 300 - 3000). IRMOS produces simultaneous spectra of approximately 100 objects in its 2.8 x 2.0 arc-min field of view (4 m telescope) using a commercial Micro Electro-Mechanical Systems (MEMS) micro-mirror array (MMA) from Texas Instruments. The IRMOS optical design consists of two imaging subsystems. The focal reducer images the focal plane of the telescope onto the MMA field stop, and the spectrograph images the MMA onto the detector. We describe ambient breadboard subsystem alignment and imaging performance of each stage independently, and ambient imaging performance of the fully assembled instrument. Interferometric measurements of subsystem wavefront error serve as a qualitative alignment guide, and are accomplished using a commercial, modified Twyman-Green laser unequal path interferometer. Image testing provides verification of the optomechanical alignment method and a measurement of near-angle scattered light due to mirror small-scale surface error. Image testing is performed at multiple field points. A mercury-argon pencil lamp provides a spectral line at 546.1 nanometers, a blackbody source provides a line at 1550 nanometers, and a CCD camera and IR camera are used as detectors. We use commercial optical modeling software to predict the point-spread function and its effect on instrument slit transmission and resolution. Our breadboard and instrument level test results validate this prediction. We conclude with an instrument performance prediction for cryogenic operation and first light in late 2003.

Connelly, Joseph A.↗

CLARREO Pathfinder Solar Diffuser Calibration Progress

Climate Absolute Radiance and Refractivity Observatory (CLARREO) Pathfinder (CPF) mission’s Hyperspectral Imager for Climate Science (HySICS) instrument’s transmissive flight diffuser calibration is presented. The absolute Bidirectional Transmittance Distribution Function (BTDF) measurement of the transmissive diffuser is needed to calculate the instrument’s absolute efficiency. Along with a known solar irradiance source such as Total Solar Irradiance Sensor (TSIS), it can provide an absolute irradiance measurement path on orbit, with NIST traceability. This provides an additional path for CPF to cross compare with other on orbit sensors’ measurement such as Visible-Infrared Imaging Radiometer Suite (VIIRS), Clouds and the Earth’s Radiant Energy System (CERES). The flight diffuser was calibrated at NASA’s Goddard Space Flight Center (GSFC) using the Facility’s Optical Scatterometer.

Bidirectional Transmittance Distribution Function↗

Apollo/Saturn 5 consolidated instrumentation plan for AS-511 (Apollo 16)

The consolidated instrumentation plan, for employing optical and electronic data acquisition systems to monitor the performance and trajectory of Apollo Saturn 5 vehicle 511 during the launch phase of the mission (prelaunch, liftoff to insertion), is presented. Telemetry, optical, and electronic tracking equipment on board the vehicle and data acquisition systems monitoring the flight are discussed. Flight safety instrumentation, vehicle data transmission systems, and geophysical instrumentation are also described.

Clark, D. E.↗

Ambient and Cryogenic Alignment Verification and Performance of the Infrared Multi-Object Spectrometer

The Infrared Multi-Object Spectrometer (IRMOS) is a facility instrument for the Kitt Peak National Observatory 4 and 2.1 meter telescopes. IRMOS is a near-IR (0.8 - 2.5 micron) spectrometer with low- to mid-resolving power (R = 300 - 3000). IRMOS produces simultaneous spectra of approximately 100 objects in its 2.8 x 2.0 arc-min field of view using a commercial Micro Electro-Mechanical Systems (MEMS) Digital Micro-mirror Device (DMD) from Texas Instruments. The IRMOS optical design consists of two imaging subsystems. The focal reducer images the focal plane of the telescope onto the DMD field stop, and the spectrograph images the DMD onto the detector. We describe ambient breadboard subsystem alignment and imaging performance of each stage independently, and the ambient and cryogenic imaging performance of the fully assembled instrument. Interferometric measurements of subsystem wavefront error serve to venfy alignment, and are accomplished using a commercial, modified Twyman-Green laser unequal path interferometer. Image testing provides further verification of the optomechanical alignment method and a measurement of near-angle scattered light due to mirror small-scale surface error. Image testing is performed at multiple field points. A mercury-argon pencil lamp provides spectral lines at 546.1 nm and 1550 nm, and a CCD camera and IR camera are used as detectors. We use commercial optical modeling software to predict the point-spread function and its effect on instrument slit transmission and resolution. Our breadboard test results validate this prediction. We conclude with an instrument performance prediction for first light.

Connelly, Joseph A.↗

Airplane Ice Detector Based on a Microwave Transmission Line

An electronic instrument that could detect the potentially dangerous buildup of ice on an airplane wing is undergoing development. The instrument is based on a microwave transmission line configured as a capacitance probe: at selected spots, the transmission-line conductors are partly exposed to allow any ice and/or liquid water present at those spots to act as predominantly capacitive electrical loads on the transmission line. These loads change the input impedance of the transmission line, as measured at a suitable excitation frequency. Thus, it should be possible to infer the presence of ice and/or liquid water from measurements of the input impedance and/or electrical parameters related to the input impedance. The sensory transmission line is of the microstrip type and thus thin enough to be placed on an airplane wing without unduly disturbing airflow in flight. The sensory spots are small areas from which the upper layer of the microstrip has been removed to allow any liquid water or ice on the surface to reach the transmission line. The sensory spots are spaced at nominal open-circuit points, which are at intervals of a half wavelength (in the transmission line, not in air) at the excitation frequency. The excitation frequency used in the experiments has been 1 GHz, for which a half wavelength in the transmission line is .4 in. (.10 cm). The figure depicts a laboratory prototype of the instrument. The impedance-related quantities chosen for use in this version of the instrument are the magnitude and phase of the scattering parameter S11 as manifested in the in-phase (I ) and quadrature (Q) outputs of the phase detector. By careful layout of the transmission line (including the half-wavelength sensor spacing), one can ensure that the amplitude and phase of the input to the phase detector keep shifting in the same direction as ice forms on one or more of the sensor areas. Although only one transmission-line sensor strip is used in the laboratory version, in a practical application, it could be desirable to install multiple strips on different areas to detect localized icing. In that case, a multiplexer should be used to connect the various strips to the phase detector for sequential measurements. Experiments have been performed with freezing and thawing of water and of water/glycol mixtures. The experiments have shown that, whether or not glycol is present, it is possible to distinguish between liquid water and ice via the I and Q outputs; in particular, the equipment can be adjusted so that when water freezes, I decreases and Q increases. With respect to the operation of this instrument, the main effect of glycol is to increase the freezing or thawing time.

Ngo, Phong↗