Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “instrument transmissions”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Feasibility study of a compact neutron resonance transmission analysis instrument

Neutron Resonance Transmission Analysis (NRTA) uses resonant absorption of neutrons to infer the absolute isotopic composition of a target object, enabling applications in a broad range of fields such as archaeology, enrichment analysis of nuclear fuel, and arms control treaty verification. In the past, NRTA involved large user facilities and complex detector systems. However, recent advances in the intensity of compact neutron sources have made compact neutron imaging designs increasingly feasible. This work describes the Monte Carlo (MC) based design of a compact epithermal NRTA radiographic instrument which uses a moderated, compact deuterium-tritium (DT) neutron source and an epithermal neutron detector. Such an instrument would have a wide range of applications, and would be especially impactful for such scenarios as nuclear inspection and arms control verification exercises, where system complexity and mobility may be of critical importance. The MC simulations presented in this work demonstrate accurate time-of-flight (TOF) reconstructions for transmitted neutron energies, capable of differentiating isotopic compositions of nuclear material with high levels of accuracy. A new generation of miniaturized and increasingly more intense neutron sources will allow this technique to achieve measurements with greater precision and speed, with significant impact on a variety of engineering and societal problems.

47 OTHER INSTRUMENTATION↗

Surface science insight note: Optimizing XPS instrument performance for quantification of spectra

X-ray photoelectron spectroscopy (XPS) provides quantitative information from photoemission peaks and shapes observed within the background due to the inelastic scattering of photoelectrons. To quantify the signal, both photoemission peaks and background in spectra must be adjusted for instrumental transmission variations that are a consequence of changes in efficiency when recording electrons with different kinetic energy. While it is generally assumed that correcting spectroscopic data for transmission is a necessary part of quantification by XPS, there are consequences for the quantification of spectra measured using an instrument for which transmission has significant curvature. In this Insight, the implications of curvature in transmission characteristics are discussed and a method based on XPS microscopy is proposed that ensures the transmission response of an instrument is free from significant curvature. An example of an instrument for which a flat transmission response is presented is achieved through collecting spectra using lens modes designed to measure stigmatic images.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

White-light Interferometry using a Channeled Spectrum: II. Calibration Methods, Numerical and Experimental Results

In the companion paper, [Appl. Opt. 46, 5853 (2007)] a highly accurate white light interference model was developed from just a few key parameters characterized in terms of various moments of the source and instrument transmission function. We develop and implement the end-to-end process of calibrating these moment parameters together with the differential dispersion of the instrument and applying them to the algorithms developed in the companion paper. The calibration procedure developed herein is based on first obtaining the standard monochromatic parameters at the pixel level: wavenumber, phase, intensity, and visibility parameters via a nonlinear least-squares procedure that exploits the structure of the model. The pixel level parameters are then combined to obtain the required 'global' moment and dispersion parameters. The process is applied to both simulated scenarios of astrometric observations and to data from the microarcsecond metrology testbed (MAM), an interferometer testbed that has played a prominent role in the development of this technology.

phase correction↗

A discussion of some proposed measurement techniques for hypersonic flight and instrumentation research experiments

Sensors, instrumentation, and test techniques proposed for the Hypersonic Flight Instrumentation and Research Experiment are discussed. The project is concerned with Mach 4 to 16 flight at pressure altitudes of 50,000 to 150,000 feet. The developmental instrumentation for the program includes angle-of-attack sensors, transition sensors, skin-friction sensors, particle sensors, species-concentration sensors, and temperature and heat flux sensors. Support instrumentation (required to monitor basic flight parameters and to supply data from which the performance of the developmental instruments may be evaluated) considered include surface pressure sensors, inertial instrumentation, magnetic attitude sensors, and signal conditioning and data transmission instrumentation.

Hellbaum, R. F.↗

Analysis of useful ion yield for Si in GaN by secondary ion mass spectrometry

The optimum detection levels that can be achieved by a secondary ion mass spectrometer are dependent on how efficiently a particular species of interest can be ionized and detected. One can determine in advance whether the analysis of a particular ion in the sample is possible, if the useful ion yield is known. The useful ion yield depends on the element, instrument transmission, the analytical conditions, the sample matrix, etc. The value of the useful ion yield for a species can diverge from one instrument type to another due to its different transmission and ionization probabilities. However, the same tendencies in the results may be expected for all types of instruments. In this paper, the authors present a quantitative secondary ion mass spectrometry analysis of the useful ion yield for the silicon dopant species in a gallium nitride matrix grown by metal organic chemical vapor deposition. Positively ionized cesium was used as the primary ion beam, and its energy was varied in the range from 0.5 to 5 kV. A quadrupole mass analyzer was utilized to collect secondary ion species of interest. The analysis results can be used to determine the primary beam energies for optimal Si sensitivity.

Senevirathna, M. K. Indika (ORCID:0000000243575029↗

Intercomparisons of Airborne Measurements of Aerosol Ionic Chemical Composition during TRACE-P and ACE-Asia

As part of the two field studies, Transport and Chemical Evolution over the Pacific (TRACE-P), and the Asian Aerosol Characterization Experiment (ACEAsia), the inorganic chemical composition of tropospheric aerosols was measured over the western Pacific from three separate aircraft using various methods. Comparisons are made between the rapid online techniques of the Particle Into Liquid Sampler (PILS) for measurement of a suite of fine particle ionic compounds and a mist chamber (MC/IC) measurement of fine sulfate, and the longer time-integrated filter and multi-orifice impactor (MOI) measurements. Comparisons between identical PILS on two separate aircraft flying in formation showed that they were highly correlated (e.g., sulfate r(sup 2) of 0.95), but were systematically different by 10 +/- 5% (linear regression slope and 95% confidence bounds), and had generally higher concentrations on the aircraft with a low turbulence inlet and shorter inlet-to-instrument transmission tubing. Comparisons of PILS and mist chamber measurements of fine sulfate on two different aircraft during formation flying had an 3 of 0.78 and a relative difference of 39% +/- 5%. MOI ionic data integrated to the PILS upper measurement size of 1.3 pm sampling from separate inlets on the same aircraft showed that for sulfate, PILS and MOI were within 14% +/- 6% and correlated with an r(sup 2) of 0.87. Most ionic compounds were within f 30%, which is in the range of differences reported between PILS and integrated samplers from ground-based comparisons. In many cases, direct intercomparison between the various instruments is difficult due to differences in upper-size detection limits. However, for this study, the results suggest that the fine particle mass composition measured from aircraft agree to within 30-40%.

Ma, Y.↗

Mock data sets for the Eboss and DESI Lyman-α forest surveys

We present a publicly-available code to generate sets of mock Lyman-α (Lyα) forest data that have realistic large-scale correlations including those due to the Baryonic Acoustic Oscillations (BAO). The primary purpose of these mocks is to test the analysis procedures of the Extended Baryon Oscillation Survey (eBOSS) and the Dark Energy Spectroscopy Instrument (DESI) surveys. The transmitted flux fraction, F(λ), of background quasars due to Lyα absorption in the intergalactic medium (IGM) is simulated using the Fluctuating Gunn-Petterson Approximation (FGPA) applied to Gaussian random fields produced through the use of fast Fourier transforms (FFT). The output includes the IGM-Lyα transmitted flux fraction along quasar lines of sight and a catalog of high-column-density systems appropriately placed at high-density regions of the IGM. This output serves as input to additional code that superimposes the IGM tranmission on realistic quasar spectra, adds absorption by high-column-density systems and metals, and simulates instrumental transmission and noise. Redshift space distortions (RSD) of the flux correlations are implemented by including the large-scale velocity-gradient field in the FGPA resulting in a correlation function of F(λ) that can be accurately predicted. One hundred realizations have been produced over the 14,000 deg 2 DESI survey footprint with 100 quasars per deg 2 . The analysis of these realizations shows that the correlations of F(λ) follows the prediction within the accuracy of eBOSS survey. Here, the most time-consuming part of the mock production occurs before application of the FGPA, and the existing pre-FGPA forests can be used to easily produce new mock sets with modified redshift-dependent bias parameters or observational conditions.

79 ASTRONOMY AND ASTROPHYSICS↗

Accuracy limitations for composition analysis by XPS using relative peak intensities: LiF as an example

Although precision in XPS can be excellent, allowing small changes to be easily observed, obtaining accurate absolute elemental composition of a solid material from relative peak intensities is generally much more problematical, involving many factors: background removal; differing analysis depths at different photoelectron kinetic energies; possible angular distribution effects; calibration of the instrument transmission function, and variations of the distribution of the photoelectron intensity between “main” peaks (those usually used for analysis) and associated substructure following the main peak, as a function of the chemical bonding of the elements concerned. The last item, coupled with the use of photoionization cross-sections and/or relative sensitivity factors, is the major subject of this paper, though it is necessary to consider the other items also, using LiF as a test case. The results show that the above issues, which are relevant to differing degrees in most XPS analyses, present significant challenges to highly accurate XPS quantification.

Brundle, Christopher R.↗

Systems Engineering of a Nuclear-Electric Spacecraft

Studies have shown that nuclear-electric propulsion systems will provide superior payload capability and unique advantages over chemical systems for high-energy deep-space missions. Conceptual design studies of unmanned spacecraft employing nuclear-electric propulsion systems have been undertaken to determine some of the major integration problems. Early recognition of these problems will help to stimulate the development effort that will be required to bring these systems into fruitful utilization. Typical designs under consideration for interplanetary missions for the next decade employ a nuclear reactor providing thermal energy to a turbogeneration system which, in turn, supplies electrical power to an ion engine for primary propulsion and additional utility power for guidance and control, powered-flight radio transmission, instrumentation, et cetera. The major systems and components which form a complete spacecraft are listed in this Report, and a review of the significant physical and operational characteristics of these various systems and components which affect spacecraft integration is made. Conceptual.configurations and detailed weight studies for a 60-kilowatts-electric Venus-capture spacecraft and a 1-megawattelectric Jupiter-capture spacecraft are shown to illustrate typical physical arrangements based on the various hardware constraints. From these configurations, the major development goals are ascertained and summarized.

SPACECRAFT↗

The DELTA MONSTER: An RPV designed to investigate the aerodynamics of a delta wing platform

The mission requirements for the performance of aerodynamic tests on a delta wind planform posed some problems, these include aerodynamic interference; structural support; data acquisition and transmission instrumentation; aircraft stability and control; and propulsion implementation. To eliminate the problems of wall interference, free stream turbulence, and the difficulty of achieving dynamic similarity between the test and actual flight aircraft that are associated with aerodynamic testing in wind tunnels, the concept of the remotely piloted vehicle which can perform a basic aerodynamic study on a delta wing was the main objective for the Green Mission - the Delta Monster. The basic aerodynamic studies were performed on a delta wing with a sweep angle greater than 45 degrees. These tests were performed at various angles of attack and Reynolds numbers. The delta wing was instrumented to determine the primary leading edge vortex formation and location, using pressure measurements and/or flow visualization. A data acquisition system was provided to collect all necessary data.

Connolly, Kristen↗

Precision X-band Doppler and ranging navigation for current and future Mars exploration missions

This paper describes a navigation error covariance analysis of two scenarios derived from the Mars Observer mission and the planned Mars Environmental SURvey (MESUR) Pathfinder mission, respectively. The analysis was performed to establish the potential navigational performance of the X-band tracking system in NASA's Deep Space Network, and to evaluate the sensitivity of the predicted performance to variations in the quantity of data acquired, the ground system error modeling assumptions, and data reduction schemes. The simulated data arcs used in the analysis are representative of the actual data arcs that will be used to predict the aim point for the Mars orbit insertion maneuver, in the case of Mars Observer, and the interplanetary trajectory aim point corresponding to the target Mars landing site in the case of MESUR Pathfinder. The results indicate that with a suitable sequential data reduction scheme and accurate calibrations of instrumentation, transmission media, and platform model parameters, navigation accuracies of 5 to 15 km (1 sigma) can be achieved, equivalent to 15 to 40 nrad in geocentric angle uncertainty.

Estefan, Jeffrey A.↗

A New Diagnostic Technique for the Solar Corona

Over the last 30-40 years spectroscopic observation of the EUV (extreme ultraviolet) line emission has proved invaluable as a diagnostic of the solar coronal plasma state. Line ratios have been used to determine electron density, electron temperature and ion flow velocity. In this paper, we present results obtained with a new measurement technique that uses spectroscopic observations of the white light corona to obtain the electron density, temperature, and flow velocity. A prototype instrument has been designed and built to obtain visible light spectra (3800-4300 A) with modest resolution. This instrument was used to obtain coronal observations during the June 2001 eclipse in Zambia. The data were corrected for sky and instrument transmission to derive the electron temperature and flow speed. Results from these measurements will be discussed.

Nelson, R.↗

Long term variability of transmission of thin In-Sn and Sn-C films for EUV instrumentation

The transmission variability is reported for two filters in the EUV, where the filters were supported on an 80% transmission nickel mesh and fabricated by means of a vacuum deposition technique. The first film consisted of 2500 A-thick indium, deposited on 500 A-thick tin, and had its primary bandpass in the 740-960 A range. The second consisted of 1800 A-thick tin and 2000 A-thick carbon, with a bandpass of 500-750 A. At the end of 10 months, the transmission of both filters was measured to check variations. It is demonstrated that the EUV transmission of such filters can change over the typical lifetime of satellite missions, and that such variation depends on the storage environment. The use of vacuum, rather than dry nitrogen storage is recommended.

Chakrabarti, S.↗

New capability for neutron transmission measurements at LANSCE: The DICER instrument

A new capability for neutron transmission measurements has been developed at the Los Alamos Neutron Science Center (LANSCE). The DICER (Device for Indirect Capture Experiments on Radionuclides) instrument is designed to tightly constrain neutron-capture cross sections for short-lived radionuclides that are beyond the reach of direct techniques, via measurement and analysis of neutron transmission resonances on these same radionuclides. The innovative DICER apparatus enables simultaneous sample-in and sample-out measurements, thus minimizing the amount of sample material needed and reducing the measurements time by half. A description of the current status of the new transmission station, along with a performance overview and results from known reactions, will be presented here.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Skylab consolidated instrumentation plan for SL-1/SL-2

The consolidated instrumentation plan is presented for employing optical and electronic data acquisition systems to monitor the performance and trajectory of Skylab 1 and Skylab 2 vehicles during the launch phase. Telemetry, optical, and electronic tracking equipment on board the vehicles, and data acquisition systems monitoring the flights are discussed. Flight safety instrumentation, vehicle data transmission systems, and instrumentation geography are also described.

Clark, D. E.↗

Alignment and Performance of the Infrared Multi-Object Spectrometer

The Infrared Multi-Object Spectrometer (IRMOS) is a principle investigator class instrument for the Kitt Peak National Observatory 4 and 2.1 meter telescopes. IRMOS is a near-IR (0.8 - 2.5 micron) spectrometer with low-to mid-resolving power (R = 300 - 3000). IRMOS produces simultaneous spectra of approximately 100 objects in its 2.8 x 2.0 arc-min field of view (4 m telescope) using a commercial Micro Electro-Mechanical Systems (MEMS) micro-mirror array (MMA) from Texas Instruments. The IRMOS optical design consists of two imaging subsystems. The focal reducer images the focal plane of the telescope onto the MMA field stop, and the spectrograph images the MMA onto the detector. We describe ambient breadboard subsystem alignment and imaging performance of each stage independently, and ambient imaging performance of the fully assembled instrument. Interferometric measurements of subsystem wavefront error serve as a qualitative alignment guide, and are accomplished using a commercial, modified Twyman-Green laser unequal path interferometer. Image testing provides verification of the optomechanical alignment method and a measurement of near-angle scattered light due to mirror small-scale surface error. Image testing is performed at multiple field points. A mercury-argon pencil lamp provides a spectral line at 546.1 nanometers, a blackbody source provides a line at 1550 nanometers, and a CCD camera and IR camera are used as detectors. We use commercial optical modeling software to predict the point-spread function and its effect on instrument slit transmission and resolution. Our breadboard and instrument level test results validate this prediction. We conclude with an instrument performance prediction for cryogenic operation and first light in late 2003.

Connelly, Joseph A.↗