Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “installed base”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

U.S. Industrial and Commercial Motor System Market Assessment Report Volume 1: Characteristics of the Installed Base

Motor systems are an integral part of our industrial and commercial facilities. They provide the motive force behind the fans, pumps, compressors, chillers, and conveyors in these facilities. Given their centrality to any facility’s operations, they are a critical energy end use to understand, particularly when developing technologies and policies to meet sustainability goals, improve productivity, and enhance resilience. In the late 1990s, the U.S. Department of Energy (DOE) conducted two seminal studies to better understand the installed stock and energy savings opportunities of industrial and commercial motor systems. In the industrial sector, The United States Industrial Electric Motor Systems Market Opportunities Assessment used primary data collected through onsite assessments and led to a greater understanding of the installed base of motor systems, their characteristics, and the opportunities for energy savings (U.S. Department of Energy, 2002). Notable findings included the following: Industrial motor systems consumed 679 billion kilowatt-hours (kWh) in 1994, representing 23 percent of U.S. electricity consumption. Cost-effective energy efficiency measures could result in 62-104 billion kWh of energy savings annually. Sixty-two percent of the energy savings potential was from fan, pump, and compressor end use equipment. Nearly half of motor system electricity consumption was attributable to approximately 3,500 facilities, or 1.5 percent of U.S. manufacturing facilities. Opportunities for Energy Savings in the Residential and Commercial Sectors with High Efficiency Electric Motors provided an evaluation of the installed stock of motor driven equipment in U.S. commercial and residential buildings and opportunities for utilization of high efficiency motors and variable speed technologies (Arthur D. Little, 1999). Notable findings included the following: Commercial motor systems consumed 343 billion kWh in 1995, with refrigeration and space conditioning constituting 93 percent of the total. Cost-effective energy efficiency measures could result in 51 billion kWh of energy savings annually. Due in no small part to these seminal studies, motor system technologies and usage characteristics have changed drastically since the late 1990s. Greater awareness of cost-effective strategies for reducing motor system electricity consumption have been developed and deployed. This includes several software tools, literature, and utility and government programs promoting energy efficiency improvements in motor driven systems. Additionally, several rounds of energy efficiency standards have been enacted, resulting in improved installed motor efficiency. The cost of variable speed drives has dropped substantially, and combined with utility rebate programs, has led to their greater adoption. Further, since these results were published, the U.S. manufacturing sector has undergone a massive transformation. Due to global competition, some sectors have relocated operations overseas. Others have brought operations onshore to avail low cost and abundant natural gas. Additionally, automation and robotics have pervaded the entire sector. Consequently, these two reports likely do not represent the current state of motor driven systems in U.S. industrial and commercial facilities. As cited in recent studies, the lack of current information on motor system electricity consumption and use characteristics limits the ability to conduct analysis on energy savings potential, develop technologies to address energy and productivity gaps, and develop programs to promote energy efficiency practices and technologies for motor systems (International Energy Agency, 2007; UNIDO, 2010; McKane and Hasanbeigi, 2011; Waide and Brunner, 2011). Specifically, the lack of information affects a range of stakeholders: Governments must rely on outdated information when setting research agendas, developing policies, and designing energy efficiency programs and offerings. Utilities and energy efficiency programs cannot identify the current market needs or potential impact when designing rebate and energy efficiency programs. Electric grid planners cannot identify motor system usage characteristics when developing plans to support the resilience of the electric grid. Manufacturers of motors, motor driven equipment, and drives are hampered when developing technologies to meet the needs of their market. Motor system end users are limited in their ability to identify energy saving opportunities within their own facilities because they do not have reliable benchmark information. In response to the lack of current information and analysis on industrial and commercial motor systems, the DOE initiated an update to these two studies. Launched in 2016 and led by Lawrence Berkeley National Laboratory (LBNL), the Motor System Market Assessment (MSMA) provides an updated, more comprehensive assessment of the installed stock of motor systems in both the industrial and commercial sectors, a review of the supply chains supporting motor and drives in the U.S., and the performance improvement opportunity available from using best available technologies and maintenance and operation practices. The outcomes of the MSMA are documented in three U.S. Industrial and Commercial Motor System Market Assessment reports, with this report being the first listed: 1. Volume 1: Characteristics of the Installed Base (this report) documents the findings on the installed base of motor systems in the U.S. industrial and commercial sectors. Quantification of energy savings potential is not documented in this report but in Volume 3. 2. Volume 2: Motors and Drives Supply Chain Review reviews the state of supply chains for motors and drives installed in U.S. industrial and commercial facilities, focusing on advanced motor and drive technologies and their constituent materials. 3. Volume 3: Energy Savings Opportunity analyzes the energy performance improvement opportunity for the installed base of U.S. industrial and commercial motor systems. This report has been prepared as a reference for motor system stakeholders. It provides factual information as could be best determined by the assessment results and avoids speculating on any findings.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Automatic Fault Detection & Diagnostics: Residential Market Analysis

This report provides an overview of the market potential for automated fault detection and diagnostics (AFDD) in the residential sector, focusing on embedded AFDD in central air conditioners (CAC) and air-source heat pumps (ASHP) as well as the use of smart diagnostic tools to ensure quality installation of CAC/ASHP equipment. The contents include background on AFDD, stakeholder engagement efforts, a technology assessment of AFDD and smart diagnostic tools, residential CAC and ASHP market trends, a characterization of the CAC and ASHP installed base, a synopsis of utility provider programs, and market barriers.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Design, scaling and cost evaluations of circulating fluidized-bed systems for biomass pyrolysis

To generate updated and transparent capital cost estimates for biomass fast pyrolysis equipment, refinery fluidized catalytic cracking design and sizing principles are examined and extended to pyrolysis of woody biomass. Capital costs for the sized equipment are estimated with process-industry software. A one-dimensional flow simulation with pyrolysis kinetics is leveraged to validate the fluidization conditions and thermal energy balance. After successful sizing and a system cost estimate of $\$$2.8 M (in 2016 US$\$$) at the biorefinery scale of 1000 metric tons per day (MTD), these methods were exercised for even smaller equipment at the distributed pyrolysis scale with modifications to the process design constraints, and not directly comparable with the 1000 MTD case, arriving at capital cost estimates of $\$$1.2 M for a 500 ton/day system and $\$$0.9 M for a 200 ton/day system. Here in this work, It is noted that this work only estimates purchased equipment costs at the ±50% accuracy level; there are significant other custom factors applicable to each installation based on location, maturity, scale, complexities during installation, engineering and licensing costs, etc. that need to be added on to these estimates to derive investment costs.

09 BIOMASS FUELS↗

Lighting System Control Data to Improve Design and Operation: Tunable Lighting System Data from NICU Patient Rooms

The advancement of LED and controls technology, computing capacity, and software provides new opportunities for researchers and designers to work together to further optimize spaces for occupant benefit. Here, lighting system control data from five neonatal intensive care unit patient rooms was collected over a 25-week monitoring period and analyzed to better understand occupant response to a tunable lighting system with automatic transitions throughout the day. Lighting systems are very rarely refined after installation based on actual use. Objective data detailing how the lighting system is used by the actual occupants highlights the opportunities for optimization after installation and provides insight for improving the next design. As use of the data becomes more commonplace, it can be leveraged for design recommendations. The collection of the data required no additional cost beyond the time for examining the data. The analysis revealed several clear opportunities for improvement, including adjustments to the default control setting at night, re-labeling of the control stations, and adjustments to the nighttime fade rate. The patient room occupants were active users of the different zones, dimming options, and manual overrides made available by the lighting system.

60 APPLIED LIFE SCIENCES↗

Small Reactors in Microgrids: Technology Modeling and Selection (Net-Zero Microgrid Program Project Report)

This report demonstrates the capabilities of the net-zero microgrid (NZM) Xendee platform for modeling an SR module with electricity, heat extraction and thermal storage in microgrids configurations. The model effectively captures the most important technical and economic considerations for SR technology specific analysis: cost and operational characteristics of SR technology and financial costs and incentives. The model can analyze multiple scenarios to establish metrics for cost-competitive and zero-carbon microgrids connected to the grid or completely isolated. The model is fully integrated within the Xendee platform for modeling and analysis of clean energy microgrids with storage and generation from renewable energy sources. The model captures the capabilities, constraints, and nuances of SR by incorporating parameters related to plant economics, design efficiency and performance, plant operation and component and fuel lifespan. The cost and operational parameters modeled in the SR module are specific to the technology selected for integration in the microgrid. Cost parameters recognize advanced nuclear technology for modular production and installation based on economies of scale from factory manufacture and related commissioning, and cost reduction through technology maturation—first-of-a-kind (FOAK) and nth-of-a-Kind (NOAK). The cost parameters include installation, operations and maintenance (O&M), fuel refueling cycle, and reactor life. Installation cost reflects economies of scale due to unit sizing at scale and colocation. O&M economies of scale for both fixed- and variable-cost fuel life-cycle costs are incurred at every refueling interval, with separate front- and back-end fuel costs, as well as waste-handling and disposition costs. This report investigates key characteristics of different SR technologies suitable for microgrid applications, including design principles, sizing, coolant properties, temperature ratings, fuel structures, and life-cycle considerations. This also includes fuel technologies applicable to these SR systems, alongside strategies for nuclear-waste and spent-fuel management and approaches to address safety, security, and proliferation challenges. Four primary groups of SR technologies are examined: water-cooled, liquid-metal-cooled, high-temperature gas-cooled, and molten-salt-cooled systems. In this report, an initial guideline for technology selection is established, aligning the characteristics of the technologies with the requirements of microgrids. The selection of technology in a microgrid is influenced by various factors, including financial capacity, location and accessibility, demand type and characteristics, reliability and resilience requirements, area constraints, and the lifespan of the microgrid. The types of electrical and non-electrical applications within the microgrid also play a significant role in technology selection. The characteristics of SRs, such as their smaller size, modularity, transportability, long refueling interval, improved safety features, ability to operate in autonomous or semi-autonomous mode, and provision of high-grade heat, are particularly appealing for microgrids. Furthermore, a list of considerations for implementing SRs in microgrids is outlined. The SR model is created to be continuously improved with the acquisition of actual data on investment and operational costs, experience with supply chains, production at scale, and field deployments. In the near term, performance data on applications in microgrids will become available from lessons learned from laboratory tests, such as those planned for the Microreactor Applications Research Validation and Evaluation Project (MARVEL), led by Idaho National Laboratory (INL). The SR model incorporates scenario data and known SR design specifications, enabling technoeconomic analysis for SR deployment in microgrids. It specifically considers the distinctive attributes of SRs as generators in technoeconomic studies. SRs can be modeled and analyzed with generation from renewable-energy sources, energy storage, and flexible loads over a range of functionality and applications. This offers a comprehensive tool for feasibility studies, scenario development, and sensitivity analysis for “what-if” consideration of any range of assumptions about SRs in microgrids and other aggregations of distributed-energy resources, including virtual power plants.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Photovoltaic Deployment Scenarios toward Global Decarbonization: Role of Disruptive Technologies

To totally decarbonize global electrical systems using photovoltaics (PVs) in the 2050–2060 decade, the world would need to install 63.4 TW of PV. This article models and explores how a PV manufacturing ramp‐up trajectory toward this goal can be achieved while assuming that investors continue to make financially rational decisions avoiding stranded production assets and therefore protecting their return on investment. The model effectively exploits experience curve benefits in both the scaling of the manufacturing process and continued progress in product design technologies. The scale‐up challenge is amplified because trajectories that achieve this goal require an unprecedented ramp‐up of production capacity over just two decades, followed by relatively modest demand to maintain the installed base and support continued population growth. It is demonstrated that sustainable ramp‐up of manufacturing is indeed possible and shown that the deployment of the requisite manufacturing capacity can be accelerated and accomplished at lower total capital cost by the introduction of disruptive technologies that have lower capital intensity, embedded energy, or higher efficiency.

14 SOLAR ENERGY↗

U.S. Industrial and Commercial Motor System Market Assessment Report. Volume 3: Energy Saving Opportunity

This report seeks to inform the potential for motor systems to support decarbonization by estimating their potential energy, electricity cost, and CO 2 emissions reduction potential from adoption of proven energy efficiency actions and advanced technologies. This is the third and final report in a series of reports disseminating the findings of the U.S. Department of Energy’s (DOE’s) Motor System Market Assessment (MSMA). The MSMA and this report focus on polyphase motor systems greater than or equal to 1 horsepower (hp) in the industrial and commercial sectors. In the U.S. Industrial and Commercial Motor System Market Assessment Report Volume 1: Characteristics of the Installed Base (Volume 1 report), it was determined that these motor systems consume more than 1,000 terawatt-hours (TWh) annually. This equates to 29% of the U.S. electric grid load and results in 765 million metric tons (MMT) of CO 2 emissions and $166 billion in electricity costs. This report finds that substantial reductions to these energy, cost, and emissions impacts are possible, with three areas of significant opportunity being (1) improved load matching, (2) replacing older inefficient motors with more efficient motors, and (3) improving the condition of fluid (e.g., air, water, compressed air) distribution systems. A summary of the savings potential from these three opportunities placed within the context of the overall consumption for motor systems is illustrated in Figure ES 1 (industrial) and Figure ES 2 (commercial).

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Options For Large-Scale Installation of Individual Heat Substations Based on International Best Practices

The purpose of this report is to provide recommendations for actions Ukraine could take to implement large-scale installation of IHSs as part of comprehensive district heating reform. The report discusses the importance of IHS in the district heating sector, then presents several case studies of approaches that European countries have taken to facilitate large-scale IHS installation in multi-apartment buildings. These case studies focus on the ownership and financing of IHS, as there are different models for how this can be done (the DH company can make the investments and recover the costs through the tariff, or building residents can make the investments themselves). They also include details on the approval process and technical specifications, as these can add additional barriers and time to the installation process.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Commercial Building Sensors and Controls Systems: Barriers and Drivers: Preprint

Building sensors and controls systems, including building automation systems, comprise the sensor-based devices installed in buildings as well as the control and automation of those devices. Optimized sensors and controls systems could lead to 29% annual energy savings in commercial buildings and are integral to the growth of grid-interactive efficient buildings. Only 13% of small commercial buildings, however, have installed sensors and controls systems, largely because of cost barriers. To accelerate adoption, this work seeks to increase the transparency of system costs and identify specific barriers and drivers. To gather industry insights, the team reached out to building owners, vendors, and contractors and conducted 21 interviews with the goal of collecting cost data and market characteristics regarding building sensors and controls. We collected the cost data in the form of invoices and used it to develop a percentage-based cost category breakdown. The interview data were analyzed using grounded theory to identify overarching concepts such as barriers, drivers, and future directions. From this analysis, we found the primary barriers to be complex and confusing systems, lack of user skills, and financial concerns, and the primary drivers to be operational benefits, insight into operations, and remote access to data. The future directions analysis highlighted the potential technological solutions to address gaps and barriers, as well as predicted drivers to increase adoption. This greater understanding of the costs, barriers, and drivers associated with commercial building sensors and controls systems lays the groundwork for increasing system adoption, reducing energy consumption, and transforming the market.

building automation system↗

Commercial Building Sensors and Controls Systems: Barriers, Drivers, and Costs

Building sensors and controls systems, including building automation systems, consists of the sensor-based devices installed in buildings and the control and automation of those devices. Optimized sensors and controls systems could lead to 29% annual energy savings in commercial buildings and are integral to the growth of grid-interactive efficient buildings. Only 8% of small commercial buildings, however, have installed sensors and controls systems. This is largely due to cost barriers. This work seeks to increase the transparency of system costs and identify specific barriers and drivers for increased adoption. To gather industry insights, the team reached out to building owners, vendors, and contractors and conducted 20 interviews with the goal of collecting cost data and market characteristics regarding building sensors and controls. The qualitative interview data was analyzed using grounded theory to identify overarching concepts, such as barriers, drivers, and future directions on the field. From this analysis, primary barriers were found to be complexity, a lack of knowledge, and money. Primary drivers were found to be the knowledge of data, savings, and remote access. The qualitative cost data was collected in the form of invoices during the interviews. The cost values were used to develop a percentage-based cost stack which identifies the average fraction of the total cost attributed to each category (hardware, software, labor, fees, and taxes). This greater understanding of costs and barriers associated with commercial building sensors and controls systems lays the groundwork for future steps in increasing system adoption, reducing energy consumption, and market transformation.

advanced building controls↗

Globally Gridded Groundwater Extraction Volumes and Costs under Six Depletion and Ponded Depth Targets

This repository contains simulated outputs from superwell – a hydro-economic tool for long-term assessment of groundwater cost and supply – providing globally gridded groundwater extractable volumes and associated unit costs ($/km³) for accessible groundwater production, based on a variety of user-defined depletion and ponded depth scenarios. Key model documentation: Niazi, H., Ferencz, S. B., Graham, N. T., Yoon, J., Wild, T. B., Hejazi, M., Watson, D. J., & Vernon, C. R. (2025). Long-term hydro-economic analysis tool for evaluating global groundwater cost and supply: Superwell v1.1. Geoscientific Model Development, 18(5), 1737-1767. https://doi.org/10.5194/gmd-18-1737-2025 Find the source code of the superwell model on GitHub: https://github.com/JGCRI/superwell Repository Overview Main output: superwell_outputs.7z contains 6 files (4.5 GB) named as superwell_py_deep_all_0.*PD_0.*DL.csv. These files present superwell outputs of global groundwater extraction volumes and cost estimates on a 0.5° scale for six scenarios with different Ponded Depth (PD; 0.3 and 0.6 m) and Depletion Limit (DL; 5%, 25%, and 40% of available volume) targets over the entire pumping lifetime of a grid cell superwell_py_deep_all_0.3PD_0.25DL_sample_100.csv contains superwell outputs for 100 data points sampled to match the global inputs' distribution superwell_py_deep_all_0.3PD_0.25DL_Grid_72548.csv contains superwell output for a single grid cell concept_v5.png provides an overview of the superwell workflow Outputs Description year_number: year of pumping depletion_limit: set depletion limit (DL) as a volume fraction of total available groundwater Mappings: continent, country, gcam_basin_id, Basin_long_name, grid_id: geographic identifiers and basin information Inputs: grid_area (km²): area of the grid cell whyclass: hydrogeological classification of the aquifer permeability (m/day), porosity (%), total_thickness (m), depth_to_water (m): aquifer properties. The geo-processed input data has been published separately: https://doi.org/10.57931/2307831 Model outputs: orig_aqfr_sat_thickness (m), aqfr_sat_thickness (m): original and remaining/instantaneous saturated thickness of the aquifer hydraulic_conductivity (m/day), transmissivity (m²/day): hydraulic properties of the aquifer radius_of_influence (m), areal_extent (km²): well radius and area of influence from the center of the well number_of_wells (-): number of wells in a grid cell determined by a ratio of well area and grid area max_drawdown (m), drawdown (m), drawdown_interference (m): well and aquifer drawdown during extraction total_head (m): total lift for the groundwater (depth to water plus drawdown) total_well_length (m): total depth of wells drilled well_yield (m³/day): pumping rate or well yield power (kW), energy (kWh): power and energy required for pumping groundwater Volume Outputs: volume_produced_perwell (m³), cumulative_vol_produced_perwell (m³): production volume metrics per well volume_produced_allwells (m³), cumulative_vol_produced_allwells (m³): aggregate extraction volumes for all wells in a grid cell available_volume (m³): available groundwater in storage for the grid cell as determined by aquifer properties depleted_vol_fraction: fraction of total volume pumped over available volumes in a grid cell (same as depletion limit) Cost Outputs: well_installation_cost ($): well installation cost based on the hydrogeological complexity of the aquifer annual_capital_cost, maintenance_cost, nonenergy_cost ($): nonenergy costs energy_cost_rate ($/kWh): electricity rate energy_cost ($): energy cost of pumping groundwater total_cost_perwell ($), total_cost_allwells ($): total annual energy and non-energy cost for each and all wells in a grid cell a unit_cost ($/m³), unit_cost_per_km3 ($/km³), unit_cost_per_acreft ($/acre-ft): total cost of pumping a unit of groundwater, indicated for different spatial units Key Resources Model documentation: Niazi, H., Ferencz, S., Graham, N., Yoon, J., Wild, T., Hejazi, M., Watson, D., & Vernon, C. (2024; In-prep). Long-term Hydro-economic Assessment Tool for Evaluating Global Groundwater Cost and Supply: Superwell v1. Geoscientific Model Development. Input data: Niazi, H., Watson, D., Hejazi, M., Yonkofski, C., Ferencz, S., Vernon, C., Graham, N., Wild, T., & Yoon, J. (2024). Global Geo-processed Data of Aquifer Properties by 0.5° Grid, Country and Water Basins. MSD-LIVE Data repository. https://doi.org/10.57931/2307831 superwell source code: https://github.com/JGCRI/superwell Cite as Niazi, H., Ferencz, S., Yoon, J., Graham, N., Wild, T., Hejazi, M., Watson, D., & Vernon, C. (2024). Globally Gridded Groundwater Extraction Volumes and Costs under Six Depletion and Ponded Depth Targets. MSD-LIVE Data repository. https://doi.org/10.57931/2307832 Contact Reach out to Hassan Niazi or Stephen Ferencz or open an issue in the superwell repository for questions or suggestions.

Earth Systems↗

A Compton transmission polarimeter for DC and SRF electron photo-injectors

The production of high-current and intense spin polarized electron beams is of great importance in electron-based facilities. Tests are planned to produce such beams in 2023 using GaAs-based photocathodes installed in the Brookhaven National Lab RHIC Coherent electron Cooling superconducting radiofrequency (SRF) photogun [1]. A fast and efficient electron polarimeter operating in the MeV energy range is required to measure the beam spin polarization. While Mott polarimeters provide larger measured asymmetries, a Compton Transmission polarimeter is well suited in the few MeV energy range. In this work, we report on a relatively compact and cost-effective Compton transmission polarimeter which has been built and calibrated at Jefferson Lab (JLab). First, we present the design of the polarimeter radiator, polarized target analyzing magnet, BGO detector assembly and data acquisition system. Next, results of a two-week commissioning study performed at the JLab Upgraded Injector Test Facility will be described. Here, a well-known polarized electron beam produced from a bulk GaAs photocathode in a dc high-voltage photogun was first measured in a 180 keV Mott scattering polarimeter, then used to characterize and calibrate the Compton transmission polarimeter as a function of the polarized target magnetization and beam properties. Finally, we report an effective analyzing power of the Compton polarimeter and compare experimental results with those produced via Geant4 simulations.

Blume, G.↗

Cost of Fish Exclusion and Passage Technologies for Hydropower

Hydropower represents a reliable source of renewable energy and accounts for approximately 7% of the total electrical generation in the United States. Future expansion of hydropower is likely to be in the form of either smaller new stream development projects or powering existing non-powered dams. For these new projects to be successful, careful analysis of risks, costs, and uncertainty to offset reduced power production as well as ensuring the protection and safe passage of migratory fish to gain public support, will be required. Exclusion and passage are two common approaches to protect fish from entrainment and impingement at hydropower facilities. The thresholds for entrainment risk and requirements for exclusion and passage often differ depending on the species involved, the characteristics of the facility, and the goals of stakeholders. While the costs associated with environmental mitigations represent a large proportion of the total costs required for the licensing of hydropower facilities, little quantitative information is present within the literature regarding the specific costs of fish exclusion and passage. Working with FOA awardee Natel Energy, scientists at Oak Ridge National Laboratory were tasked with assessing the capital construction costs for downstream fish exclusion and passage infrastructure. This report used keyword searches of an existing environmental mitigation cost data set and manual extraction of additional cost data associated with protection, mitigation, and enhancement (PM&E) measures related to positive barrier screening and passage from regulatory licensing documents available in the Federal Energy Regulatory Commission (FERC) eLibrary. This approach yielded a total of 50 PM&E mitigation measures with estimated capital construction costs pertaining to positive barrier screens, 142 pertaining to passage studies, and 26 pertaining to passage-related studies. PM&E measures associated with positive barrier screens represented <10% of the 171 total FERC project dockets available in the data set. These data were highly skewed toward conventional relicensing projects, as <7% were associated with new stream development (NSD) projects. Results from these data indicate highly variable costs associated with fish screening, with flow-normalized costs one to two orders of magnitude higher for screening with the highest exclusion capability (≤0.09 in. spacing) compared with coarser screening (1 to 2 in.). Furthermore, estimated capital costs of passage infrastructure were positively related to the scale of the project based on installed capacity for some, but not all, types of passage. These data provide an initial baseline for estimating exclusion and passage costs for hydropower development and may help developers consider options for more fish-friendly generation technologies, though gaps remain relating to a lack of data, particularly for NSD projects. More data may still be available within the FERC eLibrary, but significant effort will be required to manually identify and extract the data for future analyses.

13 HYDRO ENERGY↗

A Compton transmission polarimeter for DC and SRF electron photo-injectors

The production of high-current and intense spin polarized electron beams is of great importance in electron-based facilities. Tests are planned to produce such beams in 2023 using GaAs-based photocathodes installed in the Brookhaven National Lab RHIC Coherent electron Cooling superconducting radiofrequency (SRF) photogun [1]. A fast and efficient electron polarimeter operating in the MeV energy range is required to measure the beam spin polarization. While Mott polarimeters provide larger measured asymmetries, a Compton Transmission polarimeter is well suited in the few MeV energy range. In this work, we report on a relatively compact and cost-effective Compton transmission polarimeter which has been built and calibrated at Jefferson Lab (JLab). First, we present the design of the polarimeter radiator, polarized target analyzing magnet, BGO detector assembly and data acquisition system. Next, results of a two-week commissioning study performed at the JLab Upgraded Injector Test Facility will be described. Here, a well-known polarized electron beam produced from a bulk GaAs photocathode in a dc high-voltage photogun was first measured in a 180 keV Mott scattering polarimeter, then used to characterize and calibrate the Compton transmission polarimeter as a function of the polarized target magnetization and beam properties. Finally, we report an effective analyzing power of the Compton polarimeter and compare experimental results with those produced via Geant4 simulations.

Blume, G.↗

Initial Feasibility Assessment of Agrivoltaics in Jackson County, IL

Consistent with concerns raised in other rural communities, the agricultural community in Jackson County, IL is reluctant to install ground based photovoltaic (PV) systems on prime agricultural land. Agrivoltaic solutions have the potential to mitigate community concerns of conversion of farmland to solar energy by allowing for both energy production and farming practices to occur on the same land area. To assess the potential for agrivoltaics in Jackson County, IL, the Jackson County Coalition requested technical assistance to perform an initial technoeconomic assessment, resource assessment, and feasibility assessment based on the unique agricultural context present in the area. In this paper, the National Renewable Energy Laboratory (NREL) interviewed five Jackson County experts for five key crops (vineyards, strawberries, pumpkins, apple and pear orchards, and hemp) to examine potential for agrivoltaics integration and identify key barriers that could hamper development. NREL performed technoeconomic analysis for different agrivoltaic system designs to determine the economic constraints and opportunities of agrivoltaics development. Overall, there is no one path for agrivoltaics success in Jackson County. Pilot projects can assist in demonstrating agrivoltaic feasibility to stakeholders reluctant to be first adopters. Based on preliminary analyses, agrivoltaic integration with vineyards may prove most feasible as the per acre returns of grapes are comparable with the returns needed to offset higher solar development costs for agrivoltaic systems. In terms of technical specifications of solar, pumpkins and strawberries could be integrated into more traditional solar designs, but there are concerns with shading and pest control. There is no one size fits all solution, and many options may need exploring before a workable solution is found.

14 SOLAR ENERGY↗

Floating Photovoltaics in Hydropower Reservoirs in the United States

This report presents a comprehensive analysis of the feasibility of floating photovoltaics (FPV) in federally regulated reservoirs within the continental United States (CONUS) and to present a methodology for capturing the true costs of deployment, potential environmental impacts, and regulatory pathways for open-loop hydropower reservoirs. It is intended for stakeholders who may not be solar industry experts but who are interested in exploring the potential for FPV in their reservoirs. While there are promising opportunities, particularly in enhancing dissolved oxygen (DO) levels and potentially improving compliance with existing hydropower licenses, the current capital costs of FPV are not yet competitive with traditional land-based solar installations at the utility-scale when comparing the LCOE results. A competitive financial outlook is achievable when applying a 30% Investment Tax Credit (ITC) and considering a 5% reduction from the baseline capital expenditures (CapEx) at the Tuckertown Reservoir in North Carolina case study. The study is structured around three key pillars of research: technical potential, environmental impacts and regulatory considerations, and technoeconomic analysis. This report provides a nationwide assessment of the opportunities for FPV in terms of capacity, measured in direct current megawatts (MWDC), in reservoirs managed by the U.S. Bureau of Reclamation (USBR), the U.S. Army Corps of Engineers (USACE), and the Federal Energy Regulatory Commission (FERC). Additionally, the report introduces a heuristic model for estimating the CapEx of utility-scale FPV projects (1–100 MW), offering a baseline cost estimate for stakeholders. Finally, the report applies these models to a case study of a hydropower reservoir in North Carolina to present site-specific results.

13 - HYDRO ENERGY↗

Data release for A search for extremely-high-energy neutrinos and first constraints on the ultra-high-energy cosmic-ray proton fraction with IceCube

<h1 id="summary">Summary</h1> <p>Title: Data Release for A search for extremely-high-energy neutrinos and first constraints on the ultra-high-energy cosmic-ray proton fraction with IceCube</p> <p>The IceCube observatory analyzed 12.6 years of data in search of extremely-high-energy (EHE) neutrinos above 5 PeV. The resultant limit of the search (Fig 1), and the effective area of the event selection (Fig 7), are provided in this data release.</p> <h1 id="contents">Contents</h1> <ul> <li><p>README file: this file</p> </li> <li><p><code>differential_limit_and_sensitivity.csv</code>: a comma separated value file, giving the observed experimental differential limit, and sensitivity, of the search as a function of neutrino energy. This is the content of Fig 1 in the paper. The first column is the neutrino energy in GeV. The second column is the limit in units of GeV/cm2/s/sr. The third column is the sensitivity in units of GeV/cm2/s/sr.</p> </li> <li><p><code>effective_area.csv</code>: a comma separated value file, giving the effective area of the search as a function of energy. This is the content of Fig 7 in the paper. The first column is the neutrino energy in GeV. The second column is the total effective area of the search, summed across neutrino flavors, and averaged across neutrinos and antineutrinos, in meters-squared. The third column is the effective area of the search for the average of electron neutrino and electron antineutrinos in units of meters-squared. The fourth column is the same as the third, but for muon-flavor neutrinos. The fifth column is the same as the third and fourth, but for tau-flavor neutrinos.</p> </li> <li><p><code>demo.py</code>: a short python script to demonstrate how to read the files. Run like <code>python demo.py</code>. A standard base python installation is sufficient, as the only dependencies are numpy and matplotlib.</p> </li> </ul> <h1 id="contacts">Contacts</h1> <p>For any questions about this data release, please write to analysis@icecube.wisc.edu</p>

Astronomy and Astrophysics↗

Next generation retrofit wall panels with integrated vacuum insulation panels

Approximately two-thirds of residential buildings in the United States were constructed before the Department of Energy established energy conservation measures. These buildings present major opportunities for improving energy efficiency, though retrofitting them remains technically and economically challenging. This study presents the development and the durability evaluation of an innovative retrofit panel system that integrates vacuum insulation panels (VIP) with a nail-base panel (called a retrofit insulated panel) to enhance thermal performance with minimal disruption to occupants and without altering standard nail-based panel installation practices. Hygrothermal simulations were conducted to assess the moisture behavior of wall assemblies before and after retrofit installation under varying water vapor control strategies and climate conditions. Results indicate that, with appropriate moisture control strategy, the retrofit system effectively prevents moisture accumulation, keeping mold index values and relative humidity levels below critical thresholds. Additionally, Guarded Hot Box testing was performed to compute the effective R-value of the panel under different coverage areas that demonstrates its effectiveness in enhancing both thermal and moisture performance in existing residential buildings.

Iffa, Emishaw [ORNL]↗