Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “initial performance”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

PV Fleet Performance Data Initiative: Performance Index-Based Analysis

In this analysis, we report on 250 PV systems throughout the US, comprising 157 MWdc of system capacity and over 10,000 monthly PI values based on high-frequency (subhourly) energy data and satellite-based resource data. The distribution of PI values is analyzed, and multiple causes of underperformance are assessed, including first-year startup issues, snowfall and inverter downtime. An initial distribution of raw monthly PI values was collected with mean measured / modeled performance of PI = 0.935. After correcting for the three identifiable loss factors mentioned above, an average monthly performance of PI = 0.994 was obtained, with a distribution closely following a Gumbel Extreme Value distribution. In particular, inverter availability was found to contribute a system energy loss of 2.3% on average, except in the first six months of operation when availability losses are closer to 8%. Other startup issues beyond inverter downtime such as partial string outage contributed an additional 5% underperformance in the first year of operation across the fleet. Winter performance was also found to be 5%-10% below summer performance on average, likely due to snowfall. A simple linear relationship was found between snow loss and monthly snowfall accumulation in cm, indicating between 6% - 40% loss in months with nonzero snowfall, depending on climate.

14 SOLAR ENERGY↗

Houston, We Have a Problem-and a Solution: Solar Performance Initiative Helps Federal Building Boost Rooftop Production

In 2014, the Mickey Leland Federal Building in Houston, Texas installed a 192 kW PV system on top of its parking structure. To monitor and optimize its performance, the General Services Administration, which manages the site, responded to the Federal Energy Management Program’s request for federal agency participation in the Federal Energy Management Program Solar PV Performance Initiative.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Evaluation of short-term initial performance of a “Molekule Air” portable air cleaner

The aim of this project was to evaluate and characterize the performance of a MOLEKULE AIR air cleaner unit. The testing protocol comprised the evaluation of an unused Molekule Air unit operating at maximum (“boost” setting) fan speed setting. The device was tested over initial short-term periods of 70-80 h of continuous operation. The tested air cleaner was challenged in separate experiments with a well-characterized mixture of volatile organic compounds (VOCs), and with ozone. All tests were performed at realistic pollutant levels in a 20-m 3 environmental stainless-steel chamber. Variables controlled and measured in this study included the chamber temperature, relative humidity, the composition and concentration of the challenge VOCs, and the concentrations of ozone. Potential formation of byproducts was also investigated to assess the overall performance.

47 OTHER INSTRUMENTATION↗

Impact of electrode thick spot irregularities on polymer electrolyte membrane fuel cell initial performance

Polymer electrolyte membrane fuel cells have great potential for power generation in many applications, but to implement them on a larger scale, understanding of quality requirements, tolerances, and controls during manufacturing must improve. As part of this broad challenge, irregularities resulting from the membrane electrode assembly production process must be studied to determine if they impact the performance of the cell. One potential irregularity is a locally increased thickness of the coated or deposited electrode. In order to understand and provide insight into the impact of such irregularities, we intentionally created thick spots in the center of cathode electrodes. The thick spots fabricated by two different approaches were carefully characterized by optical microscopy, X-ray fluorescence spectroscopy and scanning electron microscopy (SEM). We found that the impact of the thick spots on the electrochemically active catalyst area and mass activity was minimal. However, specific electrode thick spot irregularities significantly impacted the mass transport properties of the cells. Based on SEM analysis, the likely cause of the performance drop is morphological changes associated with the creation of the thick spot irregularity. Spatial performance results obtained with a segmented cell system further indicated that the area of the performance impact exceeded that of the intentionally created thick spot.

25 ENERGY STORAGE↗

Advancing Our Understanding of System Availability through the PV Fleet Performance Data Initiative

The PV Fleet Performance Data Initiative partners with photovoltaic (PV) fleet owners to collect time-series data of PV production data and publishes aggregated anonymized results of system performance metrics. With an extensive dataset drawn from over 2,200 PV systems across the United States, comprising 8.5 GW and 24,000 separate inverter data channels, this initiative aims to ensure that systemic risks in the US PV fleet are detected. The current work explores system availability, revealing a pronounced dependence on time, especially within the initial 6 months of system performance. Following this start-up period, the average system availability stabilizes. Statistical analyses illustrate a median (P5O) monthly availability of 0.991 and a dependence on system size with a negative trend in availability with increasing system size. This finding indicates that larger systems experience lower availability compared to their smaller counterparts.

inverter availability↗

PV Fleet Performance Data Initiative 2026 Update

We provide an update on the PV Fleet Performance Data Initiative at the 2026 PV Reliability Workshop. Our latest runs incorporate additional data sources and an integrated analysis pipeline run on our Kestrel HPC cluster. Initial degradation findings suggest that single-axis tracked PV systems exhibit higher performance loss rates than fixed-tilt systems, an increase of 0.5 %/yr, almost double. We discuss multiple methods for identifying stuck tracker rows, which are suspected to be a contributor to the enhanced degradation. Through satellite image detection and data-driven approaches we address the topic of identifying when stuck trackers are occuring and to what extent the problem exists. Preliminary results suggest that the increased performance loss detected for the tracked systems would be consistent with stuck tracker rows affecting on the order of 5% - 10% of the system.

14 SOLAR ENERGY↗

PV Fleet Performance Data Initiative Program and Methodology

The US Department of Energy’s PV Fleet Performance Data Initiative has been launched in order to collect and evaluate production data across multiple PV fleet partners. Performance statistics are anonymized, aggregated and shared to represent a snapshot of the US commercial and utility-scale fleet. Production data have been collected from over 1500 systems representing more than 1.3 GWdc capacity. Preliminary analysis indicates median performance loss rates are in line with previous publications of system degradation, on the order of –0.6%/yr to –0.9%/yr (preliminary numbers subject to change). These values are higher than module-only degradation rates which are often used in pro-forma estimates of project performance and economics, potentially exposing owner/operators to increased risk if systems under-perform over time.

41 EE - Solar Energy Technologies Office (EE-4S)↗

Loss Factor Assessment in the 8GW PV Fleet Performance Data Initiative

This presentation is divided into the following sections: (1) photovoltaics (PV) current and future deployment; (2) the PV Fleet Performance Data Initiative; (3) fleet degradation trends; (4) high-efficiency module performance; (5) other system loss factors; and (6) conclusions.

deployment↗

Impact of polymer additives on crack mitigation of rod-coated fuel cell cathode catalyst layers

Cracks in catalyst layers (CLs) are a potential source of long-term failure in a fuel cell membrane electrode assembly (MEA). While modifications to the CL ink formulation can affect the degree of cracking, these changes may lead to lower initial performance than their cracked analogues due to the established link between formulation and performance. In this work, we explored the use of polymeric additives to mitigate CL cracks. Small quantities of poly (acrylic acid), poly (ethylene oxide), poly (methyl methacrylate), or poly (vinyl alcohol) - 5 wt% relative to ionomer mass - were added to the ink prior to its final mixing. Poly (vinyl alcohol) resulted in crack-free CLs, whereas the other polymers resulted in CLs with similar crack percentages as the control CL. Through a combination of transmission electron microscopy, X-ray computed tomography, and infrared spectroscopy, we ascribed the crack-mitigating mechanism of poly (vinyl alcohol) to its ability to hydrogen-bond with Nafion, the ion conducting polymer binder in the catalyst ink. Initial performance of this non-cracked electrode exhibited nearly identical electrochemical behavior to its cracked counterpart, demonstrating that PVA additives successfully reduce cracks while maintaining cell initial performance.

30 DIRECT ENERGY CONVERSION↗

PV Fleet Performance Data Initiative Final Technical Report (FTR)

Improved analysis and reporting of photovoltaic (PV) field performance increases the certainty of owners and financiers that systems will perform as expected. Advanced module technologies (e.g., PERC, HJT, and bifacial) introduce new degradation mechanisms and performance characteristics. This project will leverage data from the ever-increasing PV fleet to develop models and understanding of the field performance of existing and new technologies. Please see our list of public reports at https://www.nrel.gov/pv/fleet-performance-data-initiative.html. Objective 1: Support the global PV industry with scalable, robust data analysis tools that reduce the uncertainty of PV system performance and loss calculation. Objective 2: Reduce perceived risk arising from degradation rate, soiling loss, and system availability by publishing detailed statistics on U.S. fleet performance. Objective 3: Highlight factors leading to system underperformance including module type, climate, mounting configuration, etc. Objective 4: Enable continued high system performance in modern PV systems, as turnover and advances in technology bring new suppliers and high-efficiency modules into the market.

14 SOLAR ENERGY↗

Status Update: Deposition Modeling For SNF Canister CISCC

This report fulfills the M3 milestones M3SF-21PN010207025 & M3SF-20PN0102070412. During fiscal year (FY) 2020, Pacific Northwest National Laboratory (PNNL) worked to further develop the FY 2019 deposition and particle tracking models. This status report outlines these efforts and presents the progress made so far. Model development work is ongoing and is planned to continue in FY 2021. The FY 2020 model development included work on: Wind Effects. Model development and sensitivity studies, investigated how wind direction and speed affect deposition; Brownian Motion. Implementing Brownian Motion into existing models; Particle Size Variability. Depending on the particle composition, the diameter of the particle may vary with changes in relative humidity. Models were developed to analyze this; Multiphase and Fluid Film Modeling. Investigating canister surface wetting and drying, and how this effects overall deposition. Models were developed to analyze this; Difusophoresis. Performing initial work to implement diffusiophoresis into the existing models; Turbophoresis. Performing initial work to implement turbophoresis into the existing models. Much of this work will continue into FY21. The authors present initial results and discus current and future work.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Membrane Pretreatment and Cell Conditioning for Proton Exchange Membrane Water Electrolysis

As the research community studying proton exchange membrane water electrolysis (PEMWE) grows, it is important to develop methods that achieve transparent, reproducible research. Reproducibility of performance and durability is a challenge facing the PEMWE field, as the published literature includes a wide spread of results obtained with nominally similar materials. Prior round-robin performance benchmarking efforts [1] have identified inadequate cell conditioning as a major source of variation in apparent cell performance. Inadequate pre-treatment and conditioning can lead to instability in initial performance and adds ambiguity to durability measurements. However, excessively prolonged conditioning procedures limit the throughput of testing and the pace of research. Pretreatment and conditioning methods vary significantly across the research literature, but little systematic investigation is available into the mechanisms of these procedures or how procedural differences may impact results. This presentation will discuss investigations into the effects of membrane pre-treatment and operating procedures during cell conditioning on initial performance and catalyst-specific accelerated stress tests, with the aim of recommending procedures to enable clear, reproducible, and high-throughput research. Methods investigated include the use of hydrogen peroxide, acids, and hydration at elevated temperature for membrane pretreatment, and conditioning procedures such as current or voltage holds and cycling. The investigations cover both the impacts of these procedures on cell performance and stability as well as underlying mechanisms and processes taking place in the cell materials.

cell↗

Accelerator Performance Tuning for E3SM: 2022 Annual Report [Abstract]

Over the past few years, we have been porting the Energy Exascale Earth System Model (E3SM) to GPU-accelerated architectures with a focus on the Leadership Computing Facilities at Oak Ridge and Argonne National Laboratories. This brief report describes work under a small allocation on the LANL Institutional Computing Chicoma machine to perform initial porting and performance tuning of the GPU-accelerated portions of E3SM for later production use on Chicoma, Perlmutter (a similar machine at NERSC) and eventually Venado.

58 GEOSCIENCES↗

Performance Index Assessment for the PV Fleet Performance Data Initiative

We report on 250 PV systems throughout the United States, comprising 157 MWdc of system capacity and more than 10,000 monthly performance index (PI) values. Loss factors were isolated including first-year start-up issues, snowfall, soiling and inverter downtime. Inverter availability was found to contribute significant system energy loss during the first six months of operation, with an average of 8% loss occurring during this period, and 2.3% on average thereafter. Other start-up issues beyond inverter downtime, such as partial string outage, contributed additional underperformance in the first year of operation across the fleet. Winter performance was also found to be below summer performance on average, likely due to snowfall. A relationship was found between monthly snowfall accumulation in centimeters and monthly under-performance, indicating a 6%-40% loss in months with measured snowfall, depending on climate. After correcting for availability, snow and startup loss, over 90% of systems were performing within 10% of monthly expectation based on satellite resource data and PVWatts production estimates.

loss factors↗

PV Fleet Performance Data Initiative (March 2020 Methodology Report)

Data for thousands of systems by multiple sources were transmitted to NREL for evaluation. Initial automated data quality assurance (QA) checks identified hundreds of systems (QA Tier 1) with high-quality meteorological and AC production data and hundreds of QA Tier 2 systems with adequate data quality. A standard RdTools analysis was conducted for these systems, evaluating performance loss on an annualized basis. To date with the systems evaluated so far, we find a median performance loss rate (aka Rd or degradation rates) for the entire fleet of -0.72%/year based on individual inverter data, which is in line with historical degradation rates previously published for modules and systems (-0.5% to -0.9% / yr, Jordan et al. 2016). A fleet-scale distribution based on revenue-grade meter data rather than inverter AC (alternating current) data yields a slightly different result. We are working to understand the difference between this result and the inverter-based result of -0.72%/year.

14 SOLAR ENERGY↗

Barrier reinforcement for enhanced perovskite solar cell stability under reverse bias

Stability of perovskite solar cells (PSCs) under light, heat, humidity and their combinations have been notably improved recently. However, PSCs have poor reverse-bias stability that limits their real-world application. Here we report a systematic study on the degradation mechanisms of p-i-n structure PSCs under reverse bias. The oxidation of iodide by injected holes at the cathode side initialize the reverse-bias-induced degradation, then the generated neutral iodine oxidizes metal electrode such as copper, followed by drift of Cu+ into perovskites and its reduction by injected electrons, resulting in localized metallic filaments and thus device breakdown. A reinforced barrier with combined lithium fluoride, tin oxide and indium tin oxide at the cathode side reduces device dark current and avoids the corrosion of Cu0. It dramatically increases breakdown voltage to above -20 V and improved the T90 lifetime of PSCs to ~1,000 h under -1.6 V. The modified minimodule also maintained over 90% of its initial performance after 720 h of shadow tests.

degradation mechanisms↗

The CLAS12 Ring Imaging Cherenkov Detector

A ring imaging Cherenkov (RICH) detector has been installed in the CLAS12 spectrometer at Jefferson Laboratory (JLab) to provide kaon identification in the momentum range between 3 GeV/c and 8 GeV/c. The detector adopts a hybrid optics solution with aerogel radiator, light planar and spherical mirrors, and highly segmented photon detectors. We report here on the design, construction, and initial performance of the RICH during the commissioning of the detector and the first physics data taking period

PID detectors↗