Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “inductive loads”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Predictions for the drive capabilities of the RancheroS Flux Compression Generator into various load inductances using the Eulerian AMR Code Roxane

The Ranchero Magnetic Flux Compression Generator (FCG) has been used to create current pulses in the 10-­100 MA range for driving both “static” low inductance (0.5 nH) loads1 for generator demonstration purposes and high inductance (10-­20 nH) imploding liner loads2 for ultimate use in physics experiments at very high energy density. Simulations of the standard Ranchero generator have recently shown that it had a design issue that could lead to flux trapping in the generator, and a non-­ robust predictability in its use in high energy density experiments. A re-­examination of the design concept for the standard Ranchero generator, prompted by the possible appearance of an aneurism at the output glide plane, has led to a new generation of Ranchero generators designated the RancheroS (for swooped). This generator has removed the problematic output glide plane and replaced it with a region of constantly increasing diameter in the output end of the FCG cavity in which the armature is driven outward under the influence of an additional HE load not present in the original Ranchero. The resultant RancheroS generator, to be tested in LA43S-­L13, probably in early FY17, has a significantly increased initial inductance and may be able to drive a somewhat higher load inductance than the standard Ranchero. This report will use the Eulerian AMR code Roxane to study the ability of the new design to drive static loads, with a goal of providing a database corresponding to the load inductances for which the generator might be used and the anticipated peak currents such loads might produce in physics experiments. Such a database, combined with a simple analytic model of an ideal generator, where d(LI)/dt = 0, and supplemented by earlier estimates of losses in actual use of the standard Ranchero, scaled to estimate the increase in losses due to the longer current carrying perimeter in the RancheroS, can then be used to bound the expectations for the current drive one may apply to any load assembly in future experiments.

42 ENGINEERING↗

Interposed pulsed power system for fast separation of radioactive beams

This paper presents the novel design of an interposed pulsed power system, developed to drive a fast-switching magnet with a large multi-mH load inductance, and high field amplitude (> 1 T). This modulator can produce variable flat-top pulses from 1 to 30 ms with rise and fall times of less than 0.5 ms at a variable duty cycle of 3–91% into a heavily inductive load. The system employs a novel over-voltage topology to overcome the inherent inductance and achieve the fast rise and fall times, switching to a precision DC supply to efficiently maintain the flattop without requiring many-kV voltage. We present a power source design consideration, including the results of computer modeling as well as the first experimental results of a modulator scaled test model will also be presented.

47 OTHER INSTRUMENTATION↗

A Nonlinear Regression Method for Composite Protection Modeling of Induction Motor Loads

Protection equipment are used to prevent damages to induction motor loads by isolating those from the power network in the event of severe faults. Modeling the response of induction motor loads and their protection is vital for power system planning and operation, especially in understanding system's response moments after a fault has occurred. This article proposes an optimization based framework to generate composite protection models for commercial building motor loads. Introducing a mathematical abstraction, the task of finding a suitable (simplified) model of the composite protection scheme is formulated as a nonlinear regression problem. Numerical examples are provided to illustrate the application of the framework.

Kundu, Soumya↗

Analysis of ringing effects due to magnetic core materials in pulsed nuclear magnetic resonance circuits

This work presents investigations and detailed analysis of ringing in a non-resonant pulsed nuclear magnetic resonance (NMR) circuit. Ringing is a commonly observed phenomenon in high power switching circuits. The oscillations described as ringing impede measurements in pulsed NMR systems. It is therefore desirable that those oscillations decay fast. It is often assumed that one of the causes behind ringing is the role of the magnetic core used in the antenna (acting as an inductive load). We will demonstrate that an LRC subcircuit is also set-up due to the inductive load and needs to be considered due to its parasitic effects. It is observed that the parasitics associated with the inductive load become important at certain frequencies. The output response can be related to the response of an under-damped circuit and to the magnetic core material. This research work demonstrates and discusses ways of controlling ringing by considering interrelationships between different contributing factors.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Thyristor stack for pulsed inductive plasma generation

A thyristor stack for pulsed inductive plasma generation has been developed and tested. The stack design includes a free wheeling diode assembly for current reversal. Triggering of the device is achieved by a high side biased, self supplied gate driver unit using gating energy derived from a local snubber network. The structure guarantees a hard firing gate pulse for the required high dI/dt application. A single fiber optic command is needed to achieve a simultaneous turn on of the thyristors. The stack assembly is used for switching a series resonant circuit with a ringing frequency of 30 kHz. In the prototype pulsed power system described here an inductive discharge has been generated with a pulse duration of 120 {mu}s and a pulse energy of 50 J. A maximum power transfer efficiency of 84% and a peak power of 480 kW inside the discharge were achieved. System tests were performed with a purely inductive load and an inductively generated plasma acting as a load through transformer action at a voltage level of 4.1 kV, a peak current of 5 kA, and a current switching rate of 1 kA/{mu}s.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Precision electron flow measurements in a disk transmission line.

An analytic model for electron flow in a system driving a fixed inductive load is described and evaluated with particle in cell simulations. The simple model allows determining the impedance profile for a magnetically insulated transmission line given the minimum gap desired, and the lumped inductance inside the transition to the minimum gap. The model allows specifying the relative electron flow along the power flow direction, including cases where the fractional electron flow decreases in the power flow direction. The electrons are able to return to the cathode because they gain energy from the temporally rising magnetic field. The simulations were done with small cell size to reduce numerical heating. An experiment to compare electron flow to the simulations was done. The measured electron flow is {approx}33% of the value from the simulations. The discrepancy is assumed to be due to a reversed electric field at the cathode because of the inductive load and falling electron drift velocity in the power flow direction. The simulations constrain the cathode electric field to zero, which gives the highest possible electron flow.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Modeling Variable-Impedance, Magnetically Insulated, Transmission Lines

Coupling generator current to electron-beam loads and dynamic-inductance loads (z pinches) is greatly improved with low-inductance vacuum transmission lines. Typically, magnetically insulated transmission lines (MITLs) utilize nearly constant impedance geometries where the minimum impedance (anode-cathode gap) is limited by electron loss during the setup of magnetic insulation. Constant-impedance MITL designs are not optimized for low inductance (Zτ) when given a constraint on vacuum electron flow. We describe the design and the modeling of MITLs that have a nonconstant impedance. The baseline variable-impedance MITL designs are based on equilibrium vacuum-electron flow models [1] that are incorporated into the Screamer circuit code [2]. Such designs satisfy the MITL limits in the areal density of the loss current and have magnetically insulated flow that is stable everywhere along the MITL. Different MITL designs are then modeled analytically and with a 2-D particle-in-cell computer code in order to quantify subtle electron losses driven by changes to the vacuum impedance as a function of distance along the transmission line. We present a variable-impedance MITL design that delivers more current with a lower inductance than found in constant-impedance MITL designs.

47 OTHER INSTRUMENTATION↗

Model-Based Dead Time Optimization for Voltage-Source Converters Utilizing Silicon Carbide Semiconductors

Dead time significantly affects the reliability, power quality, and efficiency of voltage-source converters. For silicon carbide (SiC) devices, considering the high sensitivity of turn-off time to the operating conditions (> 5× difference between light load and full load) and characteristics of inductive loads (> 2× difference between motor load and inductor), as well as large additional energy loss induced by the freewheeling diode conduction during the superfluous dead time (~15% of the switching loss), then the traditional fixed dead time setting becomes inappropriate. This paper introduces an approach to adaptively regulate the dead time considering the current operating condition and load characteristics via synthesizing online monitored turn-off switching parameters in the microcontroller with an embedded preset optimization model. Here, based on a buck converter built with 1200-V SiC MOSFETs, the experimental results show that the proposed method is able to ensure reliability and reduce power loss by 12% at full load and 18.2% at light load (8% of the full load in this case study).

30 DIRECT ENERGY CONVERSION↗

Experimental verification of the technique for calculating a plasma opening switch and its matching to the load

A technique for calculating a plasma opening switch in an external magnetic field and its matching to a load the impedance of which increases with time was verified experimentally. The experiments were performed in the RS-20 facility both in the absence of a load and with various inductive loads. The amplitude of the voltage pulse at the input of the plasma opening switch was 0.36-0.84 MV, the current amplitude was 280-320 kA, and the pulse duration was {approx}2 {mu}s, whereas the corresponding parameters of the output pulse were 0.8-3.2 MV, 0-240 kA, and {approx}100 ns.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Miniaturized Multi-Band Antenna Design via Element Collocation and Inductive Feed Loading

In a FY09 SDRD project, four separate antennas were designed to receive signals of interest covering a broad range of frequencies. While the elements exceeded specifications, the array footprint is substantial. Research performed by the CU Microwave Active Antenna Group in collaboration with RSL, showed promise in realizing a reduced structure. This work will expand upon this previous research. This project will result in a prototype quad-band antenna.

47 OTHER INSTRUMENTATION↗

Data Challenges for Structural Health Monitoring of Electrical Machines [Slides]

Induction motors (ID) consist of a stator and a rotor. Induction motor slip decreases with decreasing load. Induction motor slip decreases with decreasing load. This talk will focus on removing closely coupled power grid frequencies in an effort to observe the true dynamic response signature of induction motors. Using the time difference between the zeros, we found the frequency as it changes over time for each of the 3 phases. The frequencies of the 3 phases were averaged to reduce the effects of sidebands on the instantaneous frequency. The frequencies of the 3 phases were averaged to reduce the effects of sidebands on the instantaneous frequency. The Kalman filter rapidly synchronizes with the expected output. The sidebands were recreated using spectral subtraction. The frequency domain shows the reduction in magnitude of the power grid frequency the Kalman output was subtracted out. Kalman filtering also reveals important data about the sidebands in healthy motors. The Continuous Wavelet Transform is an alternative to a Bandpass IIR filter used in the analysis of the acceleration data. Analysis of the acceleration data reveals 4 sidebands around the slip frequency.

42 ENGINEERING↗

Dynamic Load Inrush Current Mitigation in Islanded Microgrids Powered by Grid-Forming Inverters

Grid-forming inverters in a microgrid may trip due to high inrush current caused by a switched connection of an inductive load, e.g., a relatively large induction motor. The control scheme presented in this article includes virtual inertia control method superimposed on the cascaded controller. This article studies the impact of cascaded control scheme used for grid-forming inverter to mitigate the inrush current effects and enhance the inverter’s robustness for the safe connection of inductive and dynamic loads. Experimental tests are performed using the virtual inertia method for generating the reference angle for synchronous frame conversion. The experimental performance and sensitivity of the controller to different controller gain settings for a switched connection of an induction motor are discussed. The cascaded operation significantly mitigates the inrush currents while the inverters can perform a normal operation. The performance of the control method is tested in a laboratory-scale hardware setup of a 208V microgrid fed by 5kVA and 10kVA inverters, and the results are presented.

Gursoy, Mehmetcan↗

A 5 kA pulsed power supply for inductive and plasma loads in large volume plasma device

This paper describes 5 kA, 12 ms pulsed power supply for inductive load of Electron Energy Filter (EEF) in large volume plasma device. The power supply is based upon the principle of rapid sourcing of energy from the capacitor bank (2.8 F/200 V) by using a static switch, comprising of ten Insulated Gate Bipolar Transistors (IGBTs). A suitable mechanism is developed to ensure equal sharing of current and uniform power distribution during the operation of these IGBTs. Safe commutation of power to the EEF is ensured by the proper optimization of its components and by the introduction of over voltage protection (>6 kV) using an indigenously designed snubber circuit. Various time sequences relevant to different actions of power supply, viz., pulse width control and repetition rate, are realized through optically isolated computer controlled interface.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Modeling of Inductive Constant Power Load for Electromagnetic-Transient Simulations-Part II

This paper improves the dynamic constant power (CP) load model that was published in Part I, which is appropriate for electromagnetic-transient (EMT). The improved model conserves all features of its predecessor. For instance, it maintains a fixed power consumption (both active and reactive parts) and a fixed power factor for loads that are predominantly inductive. Furthermore, as the proposed model is a time-dependent system, it is applicable to both sinusoidal and non-sinusoidal case studies. However, the previous model cannot be easily integrated with numeric solvers because it simulated load data over one cycle all together, not sequentially in a time-step manner, due to the limitation involved with the power factor. The improved version, on the contrary, allows the load to be simulated at every time step, which would facilitate its integration with numeric solvers. The model's validity is confirmed by comparing its response with data that is synthesized from constant impedance load, and the result is satisfactory.

24 POWER TRANSMISSION AND DISTRIBUTION↗

QUASI-ISENTROPIC COMPRESSION OF MATERIALS USING THE MAGNETIC LOADING TECHNIQUE

The magnetic loading technique using pulsed power generators was first developed about a decade ago on the Z Accelerator, and has matured significantly. The recent development of small, pulsed power generators have enabled several key issues in isentropic compression experiments (ICE), such as panel design, sample preparation, and uniformity of loading to be studied. Veloce is a medium-voltage, high-current, compact pulsed power generator developed for cost effective isentropic experiments. The machine delivers approx2.5 MA of current rapidly (approx440-530 ns) into an inductive load where significant magnetic pressures are produced. Examples of recent material strength measurements from quasi-isentropic loading and unloading of materials are presented.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Length and Seed Current Scaling of a Mark X HG driven, 8 inch PBX9501 RancheroS FCG system: II

This report is intended to examine the ultimate operating limits of the combined Pt. 88 capacitor bank (CB) + MarkX Helical Generator (HG) driving a RancheroS Flux Compression Generator (FCG) with various physics experiment load inductances. As such, many degradation mechanisms are neglected in this study. In actual use, degradation of the HG output current delivered to the FCG will probably occur. Internal changes in the HG can occur due to both Ohmic heating in the generator leading to a time varying series resistance [R(t)] such as that seen in the first trial (Shot 0) of the MarkX, as well as any misbehavior, such HG internal turn to turn shorts such as seem to have occurred in subsequent MarkX tests. Both reduce the output current from the HG that is used to seed the FCG. The results discussed here are intended to probe the limits of the RancheroS driving various loads, in an ideal situation in which none of the HG or system degradation mechanisms prior to the FCG armature first motion (FM) reduce the seed current. The HG is modeled simply as a time varying inductance [L(t), as measured in Shot 0], with a constant internal resistance [R(t) = 0.2mOhm]. The RancheroS itself is fully modeled, including all FCG and load degradation mechanisms, thus probing the ultimate capabilities of the full system, independent of problems upstream of the FCG.

47 OTHER INSTRUMENTATION↗

Phase locking of an S-band wide-gap klystron amplifier with high power injection driven by a relativistic backward wave oscillator

Theoretical analyses and preliminary experiments on the phase-locking characteristics of an inductively loaded 2-cavity wide-gap klystron amplifier (WKA) with high power injection driven by a GW-class relativistic backward wave oscillator (RBWO) are presented. Electric power of the amplifier and oscillator is supplied by a single accelerator being capable of producing dual electron beams. The well phase-locking effect of the RBWO-WKA system requires the oscillator have good frequency reproducibility and stability from pulse to pulse. Thus, the main switch of the accelerator is externally triggered to stabilize the diode voltage and then the working frequency. In the experiment, frequency of the WKA is linearly locked by the RBWO. With a diode voltage of 530 kV and an input power of {approx}22 MW, an output power of {approx}230 MW with the power gain of {approx}10.2 dB is obtained from the WKA. As the main switch is triggered, the relative phase difference between the RBWO and the WKA is less than {+-}15 Degree-Sign in a single shot, and phase jitter of {+-}11 Degree-Sign is obtained within a series of shots with duration of about 40 ns.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗