Engineering PapersSearch

SEARCH · Engineering Papers

Results for “impurity seeding”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

Energetics of Single Substitutional Impurities in NiTi

Shape-memory alloys are of considerable current interest, with applications ranging from stents to Mars rover components. In this work, we present results on the energetics of single substitutional impurities in B2 NiTi. Specifically, energies of Pd, Pt, Zr and Hf impurities at both Ni and Ti sites are computed. All energies are computed using the CASTEP ab initio code, and, for comparison, using the quantum approximate energy method of Bozzolo, Ferrante and Smith. Atomistic relaxation in the vicinity of the impurities is investigated via quantum approximate Monte Carlo simulation, and in cases where the relaxation is found to be important, the resulting relaxations are applied to the ab initio calculations. We compare our results with available experimental work.

Binary Alloys

Spacecraft Water Impurity Monitor, a System for Water Quality Analysis on Exploration Missions Beyond Low Earth Orbit

Exploration missions beyond low-earth-orbit (LEO) will require advanced instrumentation to monitor water quality. Traveling beyond LEO means the transfer of water samples to an Earth-based laboratory for detailed analysis is not feasible. Detailed analysis of water composition during exploration is still necessary, because having the capability to determine the specific organic chemical causing a change in total organic carbon (TOC) or the specific metal or ionic species causing a change in conductivity has the potential to inform the crew health and system management decisions. On a new vehicle such as a lunar or Mars surface habitat or a Mars transit vehicle, finding “new” impurities not seen on ISS should be expected. The key is to identify the impurity so the correct action can be taken. On ISS we can measure TOC, conductivity, and other physical properties but do not have the capability for detailed analysis using vehicle instrumentation. This is acceptable because ISS can send samples down to Earth for further analysis and obtain the detailed composition. The Spacecraft Water Impurity Monitor (SWIM) will provide detailed water quality analysis for missions in which sample down mass is not available. SWIM is a system comprising organic and inorganic analysis modules. For organic chemicals, a gas chromatograph mass spectrometer (GCMS) detects and identifies organic impurities. For inorganic species, a capillary electrophoresis capacitively coupled contactless conductivity detection (CE-C4D) system as well as ion specific electrodes detect and identify metal ions and other inorganic salts / acids. The SWIM technology demonstration project has completed a System Requirements Review (SRR) to finalize detection requirements and is currently working to refine vehicle interface requirements for a future technology demonstration. The project also has begun preliminary flight design activities for the core analyzers in the instrument suite.

Water Monitoring

Spacecraft Water Impurity Monitor, a System for Water Quality Analysis on Exploration Missions Beyond Low Earth Orbit

Exploration missions beyond low-earth-orbit (LEO) will require advanced instrumentation to monitor water quality. Traveling beyond LEO means the transfer of water samples to an Earth-based laboratory for detailed analysis is not feasible. Detailed analysis of water composition during exploration is still necessary, because having the capability to determine the specific organic chemical causing a change in total organic carbon (TOC) or the specific metal or ionic species causing a change in conductivity has the potential to inform the crew health and system management decisions. On a new vehicle such as a lunar or Mars surface habitat or a Mars transit vehicle, finding “new” impurities not seen on ISS should be expected. The key is to identify the impurity so the correct action can be taken. On ISS we can measure TOC, conductivity, and other physical properties but do not have the capability for detailed analysis using vehicle instrumentation. This is acceptable because ISS can send samples down to Earth for further analysis and obtain the detailed composition. The Spacecraft Water Impurity Monitor (SWIM) will provide detailed water quality analysis for missions in which sample down mass is not available. SWIM is a system comprising organic and inorganic analysis modules. For organic chemicals, a gas chromatograph mass spectrometer (GCMS) detects and identifies organic impurities. For inorganic species, a capillary electrophoresis capacitively coupled contactless conductivity detection (CE-C4D) system as well as ion specific electrodes detect and identify metal ions and other inorganic salts / acids. The SWIM technology demonstration project has completed a System Requirements Review (SRR) to finalize detection requirements and is currently working to refine vehicle interface requirements for a future technology demonstration. The project also has begun preliminary flight design activities for the core analyzers in the instrument suite.

Water Monitoring

Evaluation of Ultrasonic Battery Inspection Techniques

Lithium metal batteries are prone to subtle defects such as internal dendrites, which can cause internal short circuits and lead to catastrophic ignition. These defects are often undetectable by battery management systems, prompting the need to advance nondestructive evaluation (NDE) techniques for battery applications. In this work, two ultrasonic approaches were compared to establish their relative merits for this application: local ultrasonic resonance spectroscopy, and guided wave ultrasound. Benchtop experiments on batteries seeded with lithium chips emulating plating were used to demonstrate the two techniques. The results show the ability to identify and map local changes in cell structure.

Ultrasound

Evaluation of Ultrasonic Battery Inspection Techniques

Lithium metal batteries are prone to subtle defects such as internal dendrites, which can cause internal short circuits and lead to catastrophic ignition. These defects are often undetectable by battery management systems, prompting the need to advance nondestructive evaluation (NDE) techniques for battery applications. In this work, two ultrasonic approaches were compared to establish their relative merits for this application: local ultrasonic resonance spectroscopy, and guided wave ultrasound. Benchtop experiments on batteries seeded with lithium chips emulating plating were used to demonstrate the two techniques. The results show the ability to identify and map local changes in cell structure.

Ultrasound

AstroDOME: Standardized, Mass-Produceable, Small NASA Astrophysics Observatories for Big Missions

NASA’s Goddard Space Flight Center is investigating the use of small, commercial off the shelf (COTS) spacecraft to enable breakthrough astrophysics research at radically reduced cost over previous generations of missions. This paper will focus on the Mission Systems perspective of this investigation. It will cover the spacecraft to instrument interface, and lessons learned in early concept payload development. Low-cost COTS spacecraft have proliferated in the last ~5 years. They represent an order of magnitude reduction in the cost of spacecraft bus development and acquisition. They are enabled by the advent of low-cost smallsat launch options in the immediately preceding years, and are seeded by recent distributed and disaggregated missions in other sectors such as telecommunications megaconstellations (e.g. Starlink, OneWeb, Project Kuiper) and ongoing Space Development Agency (SDA) developments. Our study was tasked with developing a standardized, mass-produceable, astrophysics payload which is reconfigurable to different wavelength bands while maintaining a single optics bench design, and a standardized mechanical, electrical, data, and thermal interface to the spacecraft bus, and which may be reconfigured to multiple COTS spacecraft offerings. In this paper we will discuss lessons learned from our case study. We will also present identified keys to mission success for performing cutting edge astrophysics observations while taking advantage of economies of scale with a disaggregated, standardized architecture.

Matthew Marcus

Protein Crystal Growth Results From the United States Microgravity Laboratory-1 Mission

Protein crystal growth experiments have been performed by this laboratory on 18 Space Shuttle missions since April, 1985. In addition, a number of microgravity experiments also have been performed and reported by other investigators. These Space Shuttle missions have been used to grow crystals of a variety of proteins using vapor diffusion, liquid diffusion, and temperature-induced crystallization techniques. The United States Microgravity Laboratory - 1 mission (USML-1, June 25 - July 9, 1992) was a Spacelab mission dedicated to experiments involved in materials processing. New protein crystal growth hardware was developed to allow in orbit examination of initial crystal growth results, the knowledge from which was used on subsequent days to prepare new crystal growth experiments. In addition, new seeding hardware and techniques were tested as well as techniques that would prepare crystals for analysis by x-ray diffraction, a capability projected for the planned Space Station. Hardware that was specifically developed for the USML-1 mission will be discussed along with the experimental results from this mission.

L J Delucas

Benchmarking Bayesian Optimization Frameworks and Acquisition Strategies for Materials Discovery and Autonomous Laboratories

Bayesian optimization (BO) can accelerate materials discovery by guiding expensive experiments toward the most promising processing conditions. We systematically compare five BO surrogate and framework combinations (Gaussian processes in Ax, Gaussian processes and Monte-Carlo neural networks in BayBE, random forests in Lolopy, and tree-structured Parzen (TPE) estimators in Hyperopt) on three benchmarks that mimic common materials design tasks (a discrete solid-electrolyte composition space, a hybrid discrete/continuous laminate-composite design problem solved with micromechanics modeling, and the continuous Ishigami analytic function which is a standard optimization benchmark). Each BO surrogate is paired with posterior mean, probability of improvement, and expected improvement acquisition functions and run for 100 trials from randomized initial samples with uniform random search providing a control. Across five random seeds per setting, BayBE’s Gaussian-process surrogate with expected improvement consistently reached ≥95 % of the known optimum in the fewest evaluations, while Lolopy’s random forest matched or exceeded GP performance on purely categorical or mixed spaces at a higher computational cost. Posterior mean alone often stagnated at local optima, underscoring the need for exploration, whereas probability and expected improvement balanced exploration and exploitation leading to better optimization in fewer trials. Execution times ranged from milliseconds for TPE to minutes for neural-network and random-forest surrogates. These results establish baseline expectations for BO in automated materials laboratories and highlight expected improvement with Gaussian processes as a reliable first choice, with random forests offering a strong alternative when categorical variables dominate. The benchmark suite and code are released to facilitate future surrogate, acquisition, and constraint-handling research in data-driven materials optimization.

Bayesian optimization