Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “impedance measurement”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Capability of Impedance Measurement Using Spread Spectrum Time-Domain Reflectometry

Spread spectrum time-domain reflectometry (SSTDR) has been proposed for measuring electrical impedance on live, energized systems, in electrically noisy environments, or for measuring multiple channels simultaneously. Here we evaluate the capability of SSTDR for impedance measurement from near dc to 96 MHz and find that they agree very well with measurements from a vector network analyzer (VNA). Time gating is used to remove (calibrate out) transmission line effects. We evaluate the frequency ranges over which SSTDR at different modulation frequencies is accurate for the measurement of series resistive–capacitive ( RC ) loads and observe that fusing measurements from multiple modulation frequencies can broaden the effective measurement bandwidth.

14 SOLAR ENERGY↗

Series tee splitter for impedance measurements

A series tee splitter comprises a primary electromagnetic transmission line and a secondary electromagnetic transmission line that is placed in a series path with the primary electromagnetic transmission line, wherein a load is attached to the end of the secondary electromagnetic transmission line and a network analyzer is connected to opposite ends of the primary electromagnetic transmission line to measure a load impedance. This configuration increases the high impedance measurement limit of the network analyzer normally seen for reflection measurements. The series tee splitter can be electrically small to provide broadband impedance information.

Halligan, Matthew↗

Immunity Study: Port Impedance Measurement of PMU and PCI testing under EMP

With the increased requirements of real-time grid monitoring, disturbance location, and situation awareness, Phasor Measurement Units (PMUs) have become more critical for the Wide Area Measurement System (WAMS). However, the vulnerability of PMUs has not been well studied, especially under electromagnetic pulse (EMP) scenarios. The stable operation of the power system will be affected directly once EMP damages them. Therefore, studying their immunity to EMP events is urgent and necessary. In this paper, the effective impedance measurement scheme and pulsed current injection (PCI) testing are proposed for the port impedance measurement and immunity levels of PMUs. The equivalent non-uniform transmission line model is established to eliminate the impact of the fixture in the de-embedding process. Then, the circuit of the pulsed current generator is set to generate a damping sinusoid, and the double exponential wave is applied to the port. Finally, using measured impedance as a generator load, the voltage and current responses of different ports are calculated in the PCI testing simulation. In conclusion, results reveal the characteristics of port impedance, waveforms of voltage and current, and distribution of accumulative energy. The relation between port impedance and the waveforms is discussed.

42 ENGINEERING↗

Immunity Study: Port Impedance Measurement of PMU and PCI testing under EMP

Phasor Measurement Units (PMUs) are critical for the Wide Area Measurement System (WAMS), especially for real-time grid monitoring, disturbance location, and situation awareness. Once they are damaged, the stable operation of the power system will be affected directly and greatly. Therefore, it is urgent and necessary to study their immunity to electromagnetic pulse (EMP) events. In this paper, an effective impedance measurement scheme is proposed for port impedance measurement of PMU. The equivalent non-uniform transmission line model is established to eliminate the impact of the fixture in the de-embedding process. Then circuit of pulsed current generator is established to generate damping sinusoid and double exponential wave applied to the port. Finally, by using measured impedance as a load of the generator, the voltage and current responses of different ports are calculated in the pulsed current injection (PCI) testing simulation. Results show that common-mode impedance is large and differential mode impedance is small. The critical condition will appear in the common mode for voltage and differential mode for current.

Zhang, Liang↗

Evaluation of Impedance Measurement Using Spread Spectrum Time Domain Reflectometry

We evaluate the feasibility of spectral time domain reflectometry (STDR) and spread spectrum time domain reflectometry (SSTDR) as a new modality for impedance measurement to test energized/noisy systems over a very broad frequency spectrum (near dc to gigahertz) as well as multiple channels in parallel. We simulate how the S/SSTDR signal parameters (signal-to-noise ratio (SNR) frequency and length of the pseudo-noise (PN) signals) affect the accuracy and usable frequency band for reflection coefficient and impedance measurement. An initial measurement validation is included. Here, we conclude with a recommendation of what will be required for a viable multichannel impedance (and reflection, transmission coefficient) measurement system for either energized or nonenergized systems, in noisy environments, that can test multiple channels simultaneously.

14 SOLAR ENERGY↗

Electronic transport mechanisms in a thin crystal of the Kitaev candidate α -RuCl 3 probed through guarded high impedance measurements

α-RuCl 3 is considered to be the top candidate material for the experimental realization of the celebrated Kitaev model, where ground states are quantum spin liquids with interesting fractionalized excitations. It is, however, known that additional interactions beyond the Kitaev model trigger in α-RuCl 3 a long-range zigzag antiferromagnetic ground state. In this work, we investigate a nanoflake of α-RuCl 3 through guarded high impedance measurements aimed at reaching the regime where the system turns into a zigzag antiferromagnet. We investigated a variety of temperatures (1.45–175 K) and out-of-plane magnetic fields (up to 11 T), finding a clear signature of a structural phase transition at ≈160 K as reported for thin crystals of α-RuCl 3 , as well as a thermally activated behavior at temperatures above ≈30 K, with a characteristic activation energy significantly smaller than the energy gap that we observe for α-RuCl 3 bulk crystals through our angle resolved photoemission spectroscopy (ARPES) experiments. Additionally, we found that below ≈30 K, transport is ruled by Efros–Shklovskii variable range hopping (VRH). Most importantly, our data show that below the magnetic ordering transition known for bulk α-RuCl 3 in the frame of the Kitaev–Heisenberg model (≈7 K), there is a clear deviation from VRH or thermal activation transport mechanisms. Finally, our work demonstrates the possibility of reaching, through specialized high impedance measurements, the thrilling ground states predicted for α-RuCl 3 at low temperatures in the frame of the Kitaev–Heisenberg model and informs about the transport mechanisms in this material in a wide temperature range.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Correcting impedance measurements for background parasitics to characterize circuit components in cryogenic environments

Predictable circuit response is a critical prerequisite for accurate electronic measurements. Here, we describe a powerful yet straightforward experimental method and analysis model that utilizes an affordable LCR meter in conjunction with an in situ parasitic-impedance background-correction procedure to measure the temperature-dependent impedance (magnitude and phase) of up to ten individual passive circuit elements in a single cryostat run. We show how the model unambiguously identified a ∼20× drop in capacitance for 22 μF 5XR multilayer ceramic capacitors cooled from 300 K to 360 mK in an environment with a parasitic capacitance of ∼300 pF. The same experimental procedure, based on a simple two-wire measurement, was also used to measure 10 and 22 pF thin-film capacitors and 100 MΩ thick-film resistors. The results showed that the resistor values increased by up to an order of magnitude when the devices were cooled from 300 K to 360 mK. Most importantly, we showed that the simple data-acquisition method, coupled with our analysis model, enabled the measurement of component parasitics, and effectively extended the accuracy of a commercial LCR meter beyond its manufacturer-guaranteed values for a wide range of measurement frequencies. We also showed that, in the current configuration, our simple approach is limited to a capacitance accuracy of ∼10 pF.

Carpenter, R. J. [Santa Clara Univ., Santa Clara, ↗

Method and system for measurement of impedance of electrochemical devices

The present disclosure provides methods for determining impedance of an electrochemical device by electrically connecting a variable impedance in parallel with the electrochemical device; electrically connecting a power supply to the electrochemical device, the power supply generating a power supply current; modulating a current through the variable impedance; measuring a stack current flowing through the electrochemical device; measuring, at the electrochemical device, a voltage across at least a portion of the electrochemical device; and calculating, based on the measured stack current and the measured voltage, the impedance of the electrochemical device. Systems for performing such methods are also provided.

Klein, Jr., Walter Ellis↗

Benchtop Autonomous Electrochemical Characterization System for Combinatorial Thin-Film Solid Oxide Electrodes

The design of materials for electrochemical energy conversion is complicated by a vast search space of candidate materials and multifaceted property requirements: multicarrier conductivity, stability, and catalytic activity are all necessary but rarely intersect. Although self-driving laboratories are rapidly rising to address such material optimization problems, the required infrastructure for integrated, large-scale robotic facilities can be cost-prohibitive. Here we develop and evaluate a closed-loop measurement system for efficient screening of proton-conducting oxide electrodes for ceramic fuel cells and electrolyzers, building on top of an existing benchtop instrument and integrating techniques for rapid impedance measurement and automated analysis. This system exemplifies a “minimum viable” self-driving implementation that can deliver substantial benefits with relatively simple infrastructure. Combinatorial thin-film microelectrode libraries are characterized with a recently developed joint time-domain and frequency-domain impedance measurement technique, which provides an order-of-magnitude acceleration relative to conventional impedance spectroscopy. The distribution of relaxation times is extracted from impedance data and analyzed without human intervention. These results feed an active learning and Bayesian optimization process that learns to predict electrochemical impedance as a function of material composition, measurement temperature, oxygen partial pressure, and electrical bias, which further reduces the screening time by tenfold with optimized experimental sequences. We apply this system to Ba⁡(Co,Fe,Zr,Y)⁢O 3−𝛿 combinatorial libraries and evaluate its effectiveness for learning material property trends and optimizing expensive-to-evaluate properties such as activation energy. This offers insights into key methodological aspects of practical autonomous experimentation, including surrogate model validation, cost-aware acquisition functions, and high-throughput data interpretation. Our results demonstrate the efficacy of the system for rapidly gathering information, but also highlight real-world experimental challenges of thin-film degradation and numerical instability in surrogate models.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Direct Measurements of Ionic Transport Behavior of Dual-Layer Porous Electrodes

To improve power and cycling performance of lithium-ion batteries, dual-layer or porosity-gradient electrodes have been proposed. By engineering a higher porosity close to the separator, the intention is to improve ion transport where it is most impactful. In this research, MacMullin numbers of two dual-layer anode samples are tested using an impedance measurement technique developed previously. To characterize the microstructure of each layer independently, we developed an improved transmission-line model that accounts for each layer's properties.Virtual experiments using COMSOL Multiphysics to simulate impedance measurements are used to examine and improve the accuracy of the numerical inversion procedure. The results for the two dual-layer anodes studied show that MacMullin numbers follow expected trends, though the anodes are quite different from each other.

Dual-Layer Electrodes↗

Characterization and Electrochemical Analysis of Acidic Condensate-Induced Corrosion on Aluminized Coating on Steel in Residential Heaters

Condensing furnace residential heaters are starting to replace outdated and less efficient non-condensing units in homes across the US. However, the burning of natural gas in these new units produces acidic gases, which can form acid droplets (H 2 SO 4 , HNO 3 , H 2 CO 3 , etc.) that are corrosive to low-grade heat exchanger metallic materials. Type-1 aluminized steel has been used in industrial applications, such as marine, heating, and automobile parts, due to its resistance to oxidation at elevated temperature. Many components of the condensing furnaces, including heat exchangers, are made from type-1 aluminized steel. We investigated the interaction of type-1 aluminized steel substrates with two acidic condensate liquids by 500 h corrosion exposures as well as short-term electrochemical impedance measurements. SEM plan and cross-sectional view images revealed damage to the Al-Si rich layer and exposure of the steel substrate. The non-uniform damage in the Al-Si rich layer was likely attributed to a pitting corrosion mechanism and induced by high acidity of the condensate liquid. Electrochemical impedance measurements in an acidic condensate revealed lower corrosion resistance of the aluminized steel surface with a weld line, identifying welded sections as preferential corrosion initiation sites.

36 MATERIALS SCIENCE↗

Impact Analysis of High-Altitude Electromagnetic Pulse Coupling Effects on Power Grid Protection Relays

Protection relays are important equipment used for protection, control, and metering functions in the power grid. These relays are used to protect critical and difficult-to-replace equipment, like generators, transformers, and capacitor banks. Once the protection devices are disturbed or damaged, a high risk of power generation interruption occurs. Therefore, it is important and necessary to study the relay’s immunity to electromagnetic pulse (EMP) events. As a preliminary step toward empirical experimentation on actual equipment, this manuscript outlines an economical and efficient methodology for evaluating the impact of an EMP. An impedance measurement strategy was employed to model the equipment, setting the stage for subsequent immunity analyses. These analyses included the pulse current injection (PCI) method, which utilized an injecting probe to introduce the transient, and frequency domain electromagnetic (FEKO) simulation, which integrated electromagnetic coupling effects into the transient simulation. The impedance measurement and simulation results in this paper provide a reliable basis for gauging equipment performance in the face of HEMP threats. The results obtained using the PCI and FEKO simulations demonstrated the performance of different port responses under a high-altitude EMP, indicating the requirement for some protection to ensure the reliable operation of relays.

42 ENGINEERING↗

Electrochemical characterization of evolving ionomer/electrocatalyst interactions throughout accelerated stress tests

Here, the degradation of polymer electrolyte membrane fuel cells (PEMFCs) catalyst layers used for heavy-duty vehicles was examined using a catalyst-specific accelerated stress test (AST). High surface area carbon supported dispersed Pt (Pt/HSC), annealed Pt (a-Pt/HSC) and PtCo (PtCo/HSC) alloy catalysts were examined over the course of 90,000 cycles by measuring changes in mass activity, O 2 transport resistance, electrochemical active surface area (ECSA), catalyst accessibility and ionomer-electrocatalyst interactions. Compared to a-Pt/HSC and Pt/HSC catalyst, the PtCo/HSC showed better initial mass activity, a larger initial mass transport loss, and faster degradation after the first 30k AST cycles, as a large portion of Co leached out during potential cycling. Pt/HSC showed higher initial performance relative to a-Pt/HSC but had faster degradation. STEM characterizations show that the ECSA losses are largely related to Pt dissolution resulting in either catalyst particle growth via the Ostwald ripening mechanism or redeposition in the membrane. Catalyst accessibility measurements showed decreased RH sensitivity for all three samples, while CO impedance measurements revealed a decrease in both Pt-water and carbon-water interactions. This implies that, Pt is either preferentially redepositing on the exterior of the carbon support, or that the ionomer is undergoing morphological changes enabling the enhanced intrusion of mesopores.

25 ENERGY STORAGE↗

Reliability, biological variability, and accuracy of multi-frequency bioelectrical impedance analysis for measuring body composition components

Introduction Bioelectrical impedance analysis (BIA) systems are gaining popularity for use in research and fitness assessments as the technology improves and becomes more affordable and easier to use. Multifrequency BIA (MF-BIA) may improve accuracy and precision using octopolar contacts for segmental analyses. Purpose Evaluate reliability, biological variability, and accuracy of component measures (total body water, mass, and composition) of commercially available MF-BIA system (InBody 770, Cerritos, California, USA). Methods Fourteen healthy military-age adults were assessed by MF-BIA in duplicate on five laboratory visits across 3 weeks (10 measures each). Participants were evaluated at the same time of day after refraining from strenuous exercise (> 48 h), alcohol consumption (> 24 h), and caffeine, nicotine, and food (> 10 h). Systematic error (test–retest reliability) and biological variability (day-to-day reliability) were summarized by intraclass correlation coefficient (ICC) values determined for body mass (fat, fat-free, total) and body water (extracellular, intracellular, total). Body composition measurements derived from BIA on the second visit were also tested for accuracy compared to dual-energy x-ray absorptiometry (DXA). Results Test–retest reliability was very high for all measurements of whole-body water and mass (ICC ≥ 0.999) and high for regional body water and mass (ICC 0.973–1.000). Biological variability was observable with very minor differences between tests (same day) for total and regional body water (0.0–0.2 L) and total and regional body mass measurements (0.0–0.2 kg); while between day differences were slightly higher (0.0–0.5 L and 0.1–0.7 kg). Compared to DXA, the MF-BIA whole-body measures showed an offset in %BF (Bias −4.0 ± 2.8%; Standard error of the estimate (SEE), 2.6%), an overprediction for total body fat-free mass (Bias 2.8 ± 2.1 kg; SEE 2.2 kg) and an underprediction of total body fat mass (Bias −2.9 ± 2.0 kg; SEE 1.9 kg). Conclusion Under controlled conditions with fit and healthy men and women, this MF-BIA system has high methodological reliability and demonstrates stable day-to-day measurements of major body composition components. Previously reported ~3% body fat offset compared to criterion methods was again confirmed. Precision of the InBody 770 shows consistency and supports further testing of this specific device as a new military standards method and suitability across a wider range of %BF.

Nutrition & Dietetics↗

Frequency Response Analysis to Monitor and Identify Changes in the Impedance of a Photovoltaic Panel Measured Online using a Power Optimizer

Photovoltaic (PV) cells are generally modeled as a current source due to photocurrent, p-n junction diodes with parasitic resistance, capacitance, and inductance. This paper proposes online frequency response analysis (FRA) to measure the impedance of a PV panel using an existing panel-level power optimizer in a PV system. The algorithm will actively perturb a small signal into a 300 W rooftop PV panel and compute its small signal impedance. The technology discussed is easy to incorporate, requires no additional hardware, doesn't alter the stability of the system, and is implemented at a steady-state point. The power optimizer initially stabilizes at an operating point and then perturbs the PV current via FRA and computes PV panel impedance. The relative standard deviation test conducted indoors under 300 W/m 2 illumination on a PV panel shows a less than 5% error rate in PV panel impedance magnitude and phase is measured using a power optimizer.

14 SOLAR ENERGY↗

Characterizing pulse reverse-pulse uranium recovery in molten LiCl-KCl with intermittent electrochemical impedance spectroscopy

In this work, EIS was applied to characterize the temporal recovery of uranium from UCl 4 onto a tungsten electrode in molten LiCl-KCl salt between sets of pulse reverse-pulse (PRP) deposition steps. Impedance measurements were fitted to an equivalent circuit (EC) model of the electrode interface using Simplex optimization to calculate the double layer capacitance, charge transfer resistance, Warburg impedance, and CPE-restricted diffusion. Diffusion of uranium towards the electrode surface dominated the surface interactions for the first 80 cycles, followed by a transition to kinetic control for the remaining 520 cycles. A decrease in the Warburg impedance showed depletion of uranium from the bulk melt, which was confirmed to be a 52.5% reduction through ICP-OES. Reduction in the phasance from CPE-restricted diffusion suggested the formation of pores in the uranium deposits, which was confirmed through SEM characterization.

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗

Void-Engineered Metamaterial Delay Line with Built-In Impedance Matching for Ultrasonic Applications

Metamaterials exhibit unique ultrasonic properties that are not always achievable with traditional materials. However, the structures and geometries needed to achieve such properties are often complex and difficult to obtain using common fabrication techniques. In the present research work, we report a novel metamaterial acoustic delay line with built-in impedance matching that is fabricated using a common 3D printer. Delay lines are commonly used in ultrasonic inspection when signals need to be separated in time for improved sensitivity. However, if the impedance of the delay line is not perfectly matched with those of both the sensor and the target medium, a strong standing wave develops in the delay line, leading to a lower energy transmission. The presented metamaterial delay line was designed to match the acoustic impedance at both the sensor and target medium interfaces. This was achieved by introducing graded engineered voids with different densities at both ends of the delay line. The measured impedances of the designed metamaterial samples show a good match with the theoretical predictions. The experimental test results with concrete samples show that the acoustic energy transmission is increased by 120% and the standing wave in the delay line is reduced by over a factor of 2 compared to a commercial delay line.

36 MATERIALS SCIENCE↗

Robust Interpretation of Electrochemical Impedance Spectra Using Numerical Complex Analysis

Electrochemical Impedance Spectroscopy (EIS) is a noninvasive technique widely used for understanding charge transfer and charge transport processes in electrochemical systems and devices. Standard approaches for the interpretation of EIS data involve starting with a hypothetical circuit model for the physical processes in the device based on experience/intuition and then fitting the EIS data to this circuit model. This work explores a mathematical approach for extracting key characteristic features from EIS data by relying on fundamental principles of complex analysis. These characteristic features can suggest the presence of inductors and constant phase elements (nonideal capacitors) from impedance data and enable us to answer questions about the identifiability and nonuniqueness of equivalent circuit models. In certain scenarios such as models with only resistors and capacitors, we are able to enumerate all possible families of circuit models. Finally, we apply the mathematical framework presented here to real-world electrochemical systems and highlight results using impedance measurements from a lithium-ion battery coin cell.

charge transfer↗