Engineering PapersSearch

SEARCH · Engineering Papers

Results for “imaging diagnostics”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Characterizing core and edge turbulence regimes with fluctuation imaging diagnostics in Wendelstein 7-X

Two density fluctuation imaging systems, phase contrast imaging (PCI) and gas puff imaging (GPI) measure spatially resolved density fluctuations with high time resolution throughout the core plasma (PCI) and in the scrape-off layer (GPI) of the Wendelstein 7-X (W7-X) stellarator. Both systems combined give a comprehensive overview of overall fluctuation levels, spectral properties such as their distribution in frequency and wavenumber space as well as their spatial distribution. These tools are used to assess changes in density turbulence in three representative discharges that transition into stable divertor detachment by different strategies (impurity seeding, density ramping and power starvation). Several general trends are identified when the radiated power fraction is systematically increased: In the plasma edge, the line emission observed by GPI shifts radially inward with a drop in electron temperature, and normalized intensity fluctuation profiles follow this inward shift. Skewness and kurtosis of these edge fluctuations are reduced, indicating a reduction of large intermittent transport events, and poloidal phase velocities decrease in magnitude. These observations are consistent with a reduced power input into the plasma edge and a general reduction of turbulent activity. Core density fluctuation levels remain nearly constant in the impurity seeding scenario, indicating that detachment does not significantly impact turbulence there. However, a strong reduction in the dominant outboard fluctuation phase velocity is observed that deviates from the previous interpretation of neoclassical radial electric field changes, showing that the core plasma is not completely unaffected. In the density ramp and power starvation scenarios, undesirable and irregular large-scale events arise clearly in both diagnostic systems as the radiative fraction is increased. Impurity seeding therefore seems to be a promising strategy on W7-X to achieve detachment without significantly altering core turbulence, especially when targeting a specific operating point in core density and heating power.

Wendelstein 7-X

Experimental investigation of H-mode pedestal turbulence using a charge exchange imaging diagnostic system at DIII-D

Microtearing modes (MTMs) (ω ~ ω de k θ ρ s ~ 0.1, k r ρ s ~ 0.3 – 1.0) are predicted to cause substantial electron thermal transport in the H-mode pedestal, limiting fusion performance on high-power devices. Localized 2D measurements of low-to-intermediate wavenumber density fluctuations in the edge of DIII-D H-mode plasmas suggest the presence of temporally intermittent or ‘bursting’ MTMs during the inter-ELM cycle in the steep gradient region. These measurements are obtained using a new intermediate radial resolution multichannel Charge eXchange Imaging (CXI) diagnostic that analyzes the intensity of the CVI emission at 529 nm. The mode is peaked near ρ = 0.97 with a radial full-width half maximum of 1.5–2.0 cm and a normalized density fluctuation amplitude peak of $\frac{dn_C}{n_C}$ ~ 5%, peaking near 60 kHz in the lab frame. The mode additionally features a broad spectral width from 30 to 180 kHz and propagates in the electron diamagnetic direction in the plasma frame. CXI measurements taken during discharges with high density and current ramps provide evidence that MTMs become unstable at finite collisionality and remain at nearly the same location in ρ-space despite scanning of rational surface position. This indicates that the location of the peak in the electron diamagnetic frequency is a stronger driving force than individual rational surfaces.

DIII-D

Characterization of a CMOS camera based film digitization platform for gated x-ray imaging diagnostics at the National Ignition Facility

Hardened gated x-ray detectors use photographic film as the data recording medium due to its low sensitivity to the high-yield neutron environments at the National Ignition Facility (NIF). The photographic film is digitized with a Photometric Data Systems (PDS) microdensitometer, which measures the film’s optical density. The PDS scanner is able to measure a dynamic range of 0–5 OD; however, raster scanning the film is time consuming and maintenance of the instrument is challenging due to legacy technology. Since film usage at NIF is expected to continue in the foreseeable future, a digitization platform that is faster and more maintainable would benefit the NIF’s current and future operations. Here, this work presents the characterization of the digital transitions (DT) atom, a CMOS camera-based digitization platform that records film data in a single image capture very quickly and has widely available user support. The preliminary results suggest that the DT atom is able to reconstruct exposures accurately enough to be a competitive alternative to the PDS Scanner.

47 OTHER INSTRUMENTATION

Implementation of heterodyne detection of radio frequency waves using phase contrast imaging

An upgrade to the DIII–D phase contrast imaging (PCI) diagnostic for detection of radio frequency waves has been implemented using low-noise optical heterodyning. Electro-optical modulation allows detection of waves with frequencies up to 500 MHz with wide flexibility restricted only by the driver electronics, with continuous adjustability up to 100 MHz and fixed frequency drivers needed for higher frequencies. The PCI diagnostic images the line-integrated plasma density fluctuations and provides absolutely calibrated measurements with good wavenumber resolution.

Rost, J. C. [Massachusetts Institute of Technology

Commissioning a time-gated camera for fast neutron beamline spatial-energy characterization at LANSCE-WNR spallation source

An energy-resolved fast neutron beam imaging diagnostic has been successfully commissioned at the Weapons Neutron Research (WNR) spallation source within the Los Alamos Neutron Science Center (LANSCE) facility. This diagnostic replaces the existing analog phosphor image plates, which integrate across all neutron energies, as well as other particles, with a near-real-time energy-sensitive imaging capability. The system uses a fast plastic scintillator coupled with an intensified CCD camera. Specifically, the Teledyne Pi-MAX4 camera is coupled with either a 4 mm thick Eljen (EJ) 204 or 228 plastic scintillator. These scintillators are most sensitive to the fast neutrons (0.8-800 MeV) directly from the spallation source rather than low energy background radiation. Experimentally, these plastic scintillators were shown to have sufficiently fast decay to differentiate the bright gamma flash from the spallation neutrons. The spatial resolution is dominated by neutron beam divergence, with minimal additional contributions from scatter and light divergence. The system successfully resolved changes in neutron beam characteristics caused by intentional proton steering variations. Additionally, simulations of scintillator light yield as a function of thickness conducted using PHITS (with Scinful-QMD package) found that increasing scintillator thickness from 4 mm to 6 or 8 mm could potentially increase brightness ~ 3x. This may be explored if there is a need to reduce image acquisition time from several minutes to under one minute.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND

Developing time-resolved x-ray diffraction diagnostics at the National Ignition Facility (invited)

As part of a program to measure phase transition timescales in materials under dynamic compression, we have designed new x-ray imaging diagnostics to record multiple x-ray diffraction measurements during a single laser-driven experiment. Our design places several ns-gated hybrid CMOS (hCMOS) sensors within a few cm of a laser-driven target. The sensors must be protected from an extremely harsh environment, including debris, electromagnetic pulses, and unconverted laser light. Another key challenge is reducing the x-ray background relative to the faint diffraction signal. Building on the success of our predecessor (Target Diffraction In Situ), we implemented a staged approach to platform development. First, we built a demonstration diagnostic (Gated Diffraction Development Diagnostic) with two hCMOS sensors to confirm we could adequately protect them from the harsh environment and also acquire acceptable diffraction data. This allowed the team to quickly assess the risks and address the most significant challenges. Here, we also collected scientifically useful data during development. Leveraging what we learned, we recently developed a much more ambitious instrument (Flexible Imaging Diffraction Diagnostic for Laser Experiments) that can field up to eight hCMOS sensors in a flexible geometry and participate in back-to-back shots at the National Ignition Facility (NIF). The design also allows for future iterations, such as faster hCMOS sensors and an embedded x-ray streak camera. The enhanced capabilities of the new instrument required a much more complex design, and the unexpected issues encountered on the first few shots at NIF remind us that complexity has consequences. Our progress in addressing these challenges is described herein, as is our current focus on improving data quality by reducing x-ray background and quantifying the uncertainties of our diffraction measurements.

36 MATERIALS SCIENCE

Spatiotemporal structure of edge harmonic oscillation and its role in ELM-free QH-mode at KSTAR

In Quiescent H-mode (QH-mode), edge-localized modes (ELMs) are naturally replaced by a low-n edge harmonic oscillation (EHO), yet the self-regulating transport mechanism driven by the EHO remains insufficiently understood. Using high-spatiotemporal-resolution imaging diagnostics on KSTAR—electron cyclotron emission imaging and broadband electron cyclotron emission—we resolve the eigenmode structure of the EHO and elucidate its regulatory role in edge transport. The EHO is localized within the pedestal near the maximum pressure gradient, propagates in the ion-diamagnetic direction, and its radial envelope expands with increasing shear, suggesting that rotational shear is closely associated with the structural evolution of the EHO. Information-theoretic Transfer Entropy analysis identifies a distinct ‘dual-stabilization’ regulatory interaction pattern: the EHO is associated with enhanced outward energy transport to limit the pressure gradient, while the background shear flow is associated with preferential regulatory influence on the EHO saturation amplitude and energy flux. These results demonstrate that the QH-mode pedestal is sustained by a shear-associated regulation mechanism, where the coupling between rotational shear and mode structure appears closely linked to the sustained ELM-free state.

ECEI

Predictive Modeling of NOx Emissions from Lean Direct Injection of Hydrogen and Hydrogen/Natural Gas Blends Using Flame Imaging and Machine Learning

This research paper explores the use of machine learning to relate images of flame structure and luminosity to measured NOx emissions. Images of reactions produced by 16 aero-engine derived injectors for a ground-based turbine operated on a range of fuel compositions, air pressure drops, preheat temperatures and adiabatic flame temperatures were captured and postprocessed. The experimental investigations were conducted under atmospheric conditions, capturing CO, NO and NOx emissions data and OH* chemiluminescence images from 27 test conditions. The injector geometry and test conditions were based on a statistically designed test plan. These results were first analyzed using the traditional analysis approach of analysis of variance (ANOVA). The statistically based test plan yielded 432 data points, leading to a correlation for NOx emissions as a function of injector geometry, test conditions and imaging responses, with 70.2% accuracy. As an alternative approach to predicting emissions using imaging diagnostics as well as injector geometry and test conditions, a random forest machine learning algorithm was also applied to the data and was able to achieve an accuracy of 82.6%. This study offers insights into the factors influencing emissions in ground-based turbines while emphasizing the potential of machine learning algorithms in constructing predictive models for complex systems.

08 HYDROGEN

A unified large language model–based framework for heterogeneous PV image diagnosis

With advances in imaging technologies, modern photovoltaic (PV) systems generate large volumes of heterogeneous image data, including visible, electroluminescence (EL), and infrared (IR) images. Existing PV image analysis models, particularly deep learning approaches, are typically task-specific and lack cross-modality generalization. To address this limitation, this paper proposes an open-source large language model (LLM)–based unified framework for heterogeneous PV image diagnostics. Through task-aware diagnostic prompting, the framework enables analysis of visible, EL, and IR images within a single pipeline, supporting both zero-shot and few-shot inference and binary and multiclass classification. It is compatible with state-of-the-art multimodal LLMs, including ChatGPT, Gemini, Claude, Qwen, and CLIP. The framework is evaluated on PV module condition classification (clean, soiling, snow, hail, and bird droppings) using visible images, cell crack detection using EL images, and hotspot detection using IR images. GPT-5.1 in few-shot mode achieves the best performance, with classification accuracy exceeding 97.3%. Open-source models such as Qwen and CLIP also deliver competitive results on visible images (around 90% accuracy), though their performance is more limited on EL and IR modalities. On the full ELPV dataset, the framework achieves 83.5% zero-shot accuracy, within 2.8% of the supervised CNN baseline, confirming scalability to larger benchmarks. Practical aspects such as reproducibility, response latency, and confidence estimation are systematically analyzed. The framework operates across PV image modalities without modality- or task-specific training, making it well suited as a rapid pre-screening tool to support downstream detailed diagnostics. A benchmark dataset of diverse labeled PV images is also released.

Li, Baojie

NEREIDS

NEREIDS (NEutron REsonance Imaging Diagnostic Suite) is a research-grade toolkit for neutron resonance imaging, providing a Rust physics core, Python bindings, and NeXus/HDF5-compliant data I/O, with a path to fast, standalone GUI workflows for VENUS/MARS.

Zhang, Chen [Oak Ridge National Laboratory (ORNL),

Frontier system-on-chip (SoC) technology for microwave diagnostics (invited)

The next generation of fusion reactors, exemplified by projects such as the Demonstration Power Plant following the International Thermonuclear Experimental Reactor, faces the monumental challenge of proving the viability of generating electricity through thermonuclear fusion. This pursuit introduces heightened complexities in diagnostic methodologies, particularly in microwave-based diagnostics. The increased neutron fluence necessitates significant reductions in vessel penetrations and the elimination of internal diagnostics, posing substantial challenges. SoC technology offers a promising solution by enabling the miniaturization, modularization, integration, and enhancing the reliability of microwave systems. After seven years of research, our team successfully pioneered the V- and W-band system-on-chip approach, leading to the development of active transmitters and passive receiver modules applied in practical settings, notably within the DIII-D tokamak project. Arrays of these modules have supported microwave imaging diagnostics. New physics measurement results from the Electron Cyclotron Emission Imaging system on DIII-D provide compelling evidence of improved diagnostics following the adoption of SoC technology. Furthermore, we achieved a breakthrough in developing an F-band SoC, advancing higher frequency capabilities for fusion devices. These achievements represent a significant leap forward in fusion diagnostic technology, marking substantial progress toward establishing reliable and efficient plasma diagnostics for future fusion reactors.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY

“Production of High Specific Activity 155 Tb, 161 Tb and 203 Pb for Research and Clinical Applications: Effective Target Design, Target Material Recycling and Radioisotope Separation”

Radioisotopes are essential for the development and application of radiopharmaceuticals that target specific diseases, such as cancer, offering unique potential for precision medicine. The growing demand for theranostic radioisotopes underscores their critical role in personalized medicine, where they enhance diagnostic imaging, minimize patient radiation exposure, and improve targeted tissue uptake, particularly in receptor- and antigen-directed therapies. The theranostic pair terbium-155 (diagnostic) and terbium-161 (therapeutic) holds significant promise for advancing individualized, targeted, and dosimetry-driven radiotherapies. However, the United States currently lacks routine and reliable production of these isotopes. This project made significant progress toward addressing this supply issue by developing production and separation methods for terbium-155 and terbium-161 while also training the next generation of the nuclear and radiochemistry workforce. This grant also strengthened collaboration between scientists at the University of Washington, the University of Missouri and Brookhaven National Laboratory. The research effort focused on evaluating target preparation methods, optimizing irradiation parameters, and refining isolation processes. In addition, the project provided extensive hands-on training to graduate students and postdoctoral fellows, equipping them with expertise in radioisotope production technologies and fostering the growth of the nuclear science workforce.

07 ISOTOPE AND RADIATION SOURCES

Analysis of streaked images of x-ray self-emission in laser-driven spherical implosions

Imaging of x-ray self-emission provides a powerful in situ measurement of the spatial and temporal evolution of high-energy-density plasmas. However, interpretation of these measurements requires detailed understanding of the data-generating process. This work presents a case study in the interpretation of x-ray self-emission data for the specific application of streaked one-dimensional slit imaging of spherical laser-driven implosions. A comprehensive generative model of the streaked slit-imaging diagnostic is developed including detailed treatments of the radiation transfer, photometrics, and photostatistics associated with the measurement. The model is used to generate realistic synthetic streaked images and to analyze experimental streaked images to extract important physical quantities of interest. An example analysis of streaked images from implosion experiments on the OMEGA laser is presented, where the model developed in this work is used to constrain the trajectory and peak velocity of the implosion using Bayesian inference.

Bayesian inference

X-ray microscopy and talbot imaging with the matter in extreme conditions X-ray imager at LCLS

The last decade has shown the great potential that X-ray Free Electron Lasers (FEL) have to study High Energy Density (HED) physics. Experiments at FELs have made significant breakthroughs in Shock Physics and Dynamic Diffraction, Dense Plasma Physics and Warm Dense Matter Science, using techniques such as isochoric heating, inelastic scattering, small angle scattering and X-ray diffraction. In addition, and complementary to these techniques, the coherent properties of the FEL beam can be used to image HED samples with high fidelity. We present new imaging diagnostics and techniques developed at the Matter in Extreme Conditions (MEC) instrument at Linac Coherent Light Source (LCLS) over the last few years. We show results in Phase Contrast Imaging geometry, where the X-ray beam propagates from the target to a camera revealing its phase, as well as in Direct Imaging geometry, where a real image of the sample plane is produced in the camera with a spatial resolution down to 200 nm. Last, we show an implementation of the Talbot Imaging method allowing both X-ray phase and intensity measurements change introduced by a target with sub-micron resolution.

47 OTHER INSTRUMENTATION

Production of High Specific Activity 155 Tb, 161 Tb and 203 Pb for Research and Clinical Applications: Effective Target Design, Target Material Recycling and Radioisotope Separation (Final Technical Report)

The overall objectives of this project were (1) to develop methods for the production and separation of a diagnostic and therapeutic or “theranostic” pair of radioisotopes, terbium-155 ( 155 Tb) and terbium-161 ( 161 Tb) and (2) to train graduate students and postdoctoral fellows in technologies and methods used in radionuclide production. Radionuclides can be incorporated into drugs called radiopharmaceuticals that target a specific disease (e.g., cancer). The need for theranostic radionuclides is escalating with the clinical translation of radiopharmaceuticals due to their implementation in personalized medicine, which has demonstrated enhanced patient treatments. High purity and high specific activity radionuclides are critical for theranostic agent development, for example to maintain diagnostic image quality, to minimize radiation dose to the patient, and to increase uptake in the targeted tissue (e.g., tumor), especially in the case of receptor- and antigen-targeted agents. The 155 Tb (diagnostic) and 161 Tb (therapeutic) radioisotopes that were generated through this project are a theranostic pair with demonstrated potential for the development and translation into individualized, targeted, and dosimetry-driven radiotherapies. However, the development of such radiotherapies has been hindered by the lack of a routine and reliable supply of these isotopes in the United States. Methods for the production, separation, and supply of 155 Tb and 161 Tb were investigated and developed in this project. Further, the strong emphasis throughout the project on the training of graduate students and postdoctoral fellows has helped to ensure and enhance the nuclear science workforce through the training of the next generation of highly qualified scientists in nuclear and radiochemistry. This grant also continued a collaboration between scientists at the University of Washington (UW), the University of Missouri (MU) and Brookhaven National Laboratory (BNL). All three institutions were involved in the project, but to different degrees on the various tasks through which the overall objectives were met.

07 ISOTOPE AND RADIATION SOURCES