Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “image similarity quantification”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Crystallographic variant mapping using precession electron diffraction data

In this work, we developed three methods to map crystallographic variants of samples at the nanoscale by analyzing precession electron diffraction data using a high-temperature shape memory alloy and a VO2 thin film on sapphire as the model systems. The three methods are (I) a user-selecting-reference pattern approach, (II) an algorithm-selecting-reference-pattern approach, and (III) a k-means approach. In the first two approaches, Euclidean distance, Cosine, and Structural Similarity (SSIM) algorithms were assessed for the diffraction pattern similarity quantification. We demonstrated that the Euclidean distance and SSIM methods outperform the Cosine algorithm. We further revealed that the random noise in the diffraction data can dramatically affect similarity quantification. Denoising processes could improve the crystallographic mapping quality. With the three methods mentioned above, we were able to map the crystallographic variants in different materials systems, thus enabling fast variant number quantification and clear variant distribution visualization. The advantages and disadvantages of each approach are also discussed. We expect these methods to benefit researchers who work on martensitic materials, in which the variant information is critical to understand their properties and functionalities.

Crystallographic variant mapping↗

TU-AB-BRA-06: Texture Feature Reproducibility Between PET/CT and PET/MR Imaging Modalities

Purpose: Radiomics involves the extraction of texture features from different imaging modalities with the purpose of developing models to predict patient treatment outcomes. The purpose of this study is to investigate texture feature reproducibility across [18F]FDG PET/CT and [18F]FDG PET/MR imaging in patients with primary malignancies. Methods: Twenty five prospective patients with solid tumors underwent clinical [18F]FDG PET/CT scan followed by [18F]FDG PET/MR scans. In all patients the lesions were identified using nuclear medicine reports. The images were co-registered and segmented using an in-house auto-segmentation method. Fifty features, based on the intensity histogram, second and high order matrices, were extracted from the segmented regions from both image data sets. One-way random-effects ANOVA model of the intra-class correlation coefficient (ICC) was used to establish texture feature correlations between both data sets. Results: Fifty features were classified based on their ICC values, which were found in the range from 0.1 to 0.86, in three categories: high, intermediate, and low. Ten features extracted from second and high-order matrices showed large ICC ≥ 0.70. Seventeen features presented intermediate 0.5 ≤ ICC ≤ 0.65 and the remaining twenty three presented low ICC ≤ 0.45. Conclusion: Features with large ICC values could be reliable candidates for quantification as they lead to similar results from both imaging modalities. Features with small ICC indicates a lack of correlation. Therefore, the use of these features as a quantitative measure will lead to different assessments of the same lesion depending on the imaging modality from where they are extracted. This study shows the importance of the need for further investigation and standardization of features across multiple imaging modalities.

60 APPLIED LIFE SCIENCES↗

Atomic force microscopy applied to the quantification of nano-precipitates in thermo-mechanically treated microalloyed steels

Quantification of nanometer-size precipitates in microalloyed steels has been traditionally performed using transmission electron microscopy (TEM), in spite of its complicated sample preparation procedures, prone to preparation errors and sample perturbation. In contrast to TEM procedures, atomic force microscopy (AFM) is performed on the as-prepared specimen, with sample preparation requirements similar to those for optical microscopy (OM), rendering three-dimensional representations of the sample surface with vertical resolution of a fraction of a nanometer. In AFM, contrast mechanisms are directly related to surface properties such as topography, adhesion, and stiffness, among others. Chemical etching was performed using 0.5% nital, at time intervals between 4 and 20 s, in 4 s steps, until reaching the desired surface finish. For the present application, an average surface-roughness peak-height below 200 nm was sought. Quantification results of nanometric precipitates were obtained from the statistical analysis of AFM images of the microstructure developed by microalloyed Nb and V-Mo steels. Topography and phase contrast AFM images were used for quantification. The results obtained using AFM are consistent with similar TEM reports. - Highlights: Black-Right-Pointing-Pointer We quantified nanometric precipitates in Nb and V-Mo microalloyed steels using AFM. Black-Right-Pointing-Pointer Microstructures of the thermo-mechanically treated microalloyed steels were used. Black-Right-Pointing-Pointer Topography and phase contrast AFM images were used for quantification. Black-Right-Pointing-Pointer AFM results are comparable with traditionally obtained TEM measurements.

36 MATERIALS SCIENCE↗

MO-G-BRF-01: BEST IN PHYSICS (JOINT IMAGING-THERAPY) - Sensitivity of PET-Based Texture Features to Respiratory Motion in Non-Small Cell Lung Cancer (NSCLC)

Purpose: PET-based texture features are used to quantify tumor heterogeneity due to their predictive power in treatment outcome. We investigated the sensitivity of texture features to tumor motion by comparing whole body (3D) and respiratory-gated (4D) PET imaging. Methods: Twenty-six patients (34 lesions) received 3D and 4D [F-18]FDG-PET scans before chemo-radiotherapy. The acquired 4D data were retrospectively binned into five breathing phases to create the 4D image sequence. Four texture features (Coarseness, Contrast, Busyness, and Complexity) were computed within the the physician-defined tumor volume. The relative difference (δ) in each measure between the 3D- and 4D-PET imaging was calculated. Wilcoxon signed-rank test (p<0.01) was used to determine if δ was significantly different from zero. Coefficient of variation (CV) was used to determine the variability in the texture features between all 4D-PET phases. Pearson correlation coefficient was used to investigate the impact of tumor size and motion amplitude on δ. Results: Significant differences (p<<0.01) between 3D and 4D imaging were found for Coarseness, Busyness, and Complexity. The difference for Contrast was not significant (p>0.24). 4D-PET increased Busyness (∼20%) and Complexity (∼20%), and decreased Coarseness (∼10%) and Contrast (∼5%) compared to 3D-PET. Nearly negligible variability (CV=3.9%) was found between the 4D phase bins for Coarseness and Complexity. Moderate variability was found for Contrast and Busyness (CV∼10%). Poor correlation was found between the tumor volume and δ for the texture features (R=−0.34−0.34). Motion amplitude had moderate impact on δ for Contrast and Busyness (R=−0.64− 0.54) and no impact for Coarseness and Complexity (R=−0.29−0.17). Conclusion: Substantial differences in textures were found between 3D and 4D-PET imaging. Moreover, the variability between phase bins for Coarseness and Complexity was negligible, suggesting that similar quantification can be obtained from all phases. Texture features, blurred out by respiratory motion during 3D-PET acquisition, can be better resolved by 4D-PET imaging with any phase.

60 APPLIED LIFE SCIENCES↗

Quantification and visualization of uncertainties in reconstructed penumbral images of implosions at Omega

Penumbral imaging is a technique used in plasma diagnostics in which a radiation source shines through one or more large apertures onto a detector. To interpret a penumbral image, one must reconstruct it to recover the original source. The inferred source always has some error due to noise in the image and uncertainty in the instrument geometry. Interpreting the inferred source thus requires quantification of that inference’s uncertainty. Markov chain Monte Carlo algorithms have been used to quantify uncertainty for similar problems but have never been used for the inference of the shape of an image. Because of this, there are no commonly accepted ways of visualizing uncertainty in two-dimensional data. This paper demonstrates the application of the Hamiltonian Monte Carlo algorithm to the reconstruction of penumbral images of fusion implosions and presents ways to visualize the uncertainty in the reconstructed source. This methodology enables more rigorous analysis of penumbral images than has been done in the past.

Instruments & Instrumentation↗

MO-AB-BRA-05: [18F]NaF PET/CT Imaging Biomarkers in Metastatic Prostate Cancer

Purpose: Clinical use of {sup 18}F-Sodium Fluoride (NaF) PET/CT in metastatic settings often lacks technology to quantitatively measure full disease dynamics due to high tumor burden. This study assesses radiomics-based extraction of NaF PET/CT measures, including global metrics of overall burden and local metrics of disease heterogeneity, in metastatic prostate cancer for correlation to clinical outcomes. Methods: Fifty-six metastatic Castrate-Resistant Prostate Cancer (mCRPC) patients had NaF PET/CT scans performed at baseline and three cycles into chemotherapy (N=16) or androgen-receptor (AR) inhibitors (N=39). A novel technology, Quantitative Total Bone Imaging (QTBI), was used for analysis. Employing hybrid PET/CT segmentation and articulated skeletal-registration, QTBI allows for response assessment of individual lesions. Various SUV metrics were extracted from each lesion (iSUV). Global metrics were extracted from composite lesion-level statistics for each patient (pSUV). Proportion of detected lesions and those with significant response (%-increase or %-decrease) was calculated for each patient based on test-retest limits for iSUV metrics. Cox proportional hazard regression analyses were conducted between imaging metrics and progression-free survival (PFS). Results: Functional burden (pSUV{sub total}) assessed mid-treatment was the strongest univariate predictor of PFS (HR=2.03; p<0.0001). Various global metrics outperformed baseline clinical markers, including fraction of skeletal burden, mean uptake (pSUV{sub mean}), and heterogeneity of average lesion uptake (pSUV{sub hetero}). Of 43 patients with paired baseline/mid-treatment imaging, 40 showed heterogeneity in lesion-level response, containing populations of lesions with both increasing/decreasing metrics. Proportion of lesions with significantly increasing iSUV{sub mean} was highly predictive of clinical PFS (HR=2.0; p=0.0002). Patients exhibiting higher proportion of lesions with decreasing iSUV{sub total} saw prolonged radiographic PFS (HR=0.51; p=0.02). Conclusion: Technology presented here provides comprehensive disease quantification on NaF PET/CT imaging, showing strong correlation to clinical outcomes. Total functional burden as well as proportions of similarly responding lesions was predictive of PFS. This supports ongoing development of NaF PET/CT based imaging biomarkers in mCRPC. Prostate Cancer Foundation.

60 APPLIED LIFE SCIENCES↗

Bayesian SegNet for Semantic Segmentation with Improved Interpretation of Microstructural Evolution During Irradiation of Materials

Understanding the relationship between the evolution of microstructures of irradiated LiAlO2pellets and tritium diffusion, retention and release could improve predictions of tritium performance. Given expert-labeled segmented images of irradiated and unirradiated pellets, we trained Deep Convolutional Neural Networks to segment images into defect, grain, and boundary classes. Qualitative microstructural information was calculated from these segmented images to facilitate the comparison of unirradiated and irradiated pellets. We tested modifications to improve the sensitivity of the model, including incorporating meta-data into the model and utilizing uncertainty quantification. The predicted segmentation was similar to the expert-labeled segmentation for most methods of microstructural qualification, including pixel proportion, defect area, and defect density. Overall, the high performance metrics for the best models for both irradiated and unirradiated images shows that utilizing neural network models is a viable alternative to expert-labeled images.

Oostrom, Marjolein T.↗

Least squares parameter estimation methods for material decomposition with energy discriminating detectors

Purpose: Energy resolving detectors provide more than one spectral measurement in one image acquisition. The purpose of this study is to investigate, with simulation, the ability to decompose four materials using energy discriminating detectors and least squares minimization techniques. Methods: Three least squares parameter estimation decomposition techniques were investigated for four-material breast imaging tasks in the image domain. The first technique treats the voxel as if it consisted of fractions of all the materials. The second method assumes that a voxel primarily contains one material and divides the decomposition process into segmentation and quantification tasks. The third is similar to the second method but a calibration was used. The simulated computed tomography (CT) system consisted of an 80 kVp spectrum and a CdZnTe (CZT) detector that could resolve the x-ray spectrum into five energy bins. A postmortem breast specimen was imaged with flat panel CT to provide a model for the digital phantoms. Hydroxyapatite (HA) (50, 150, 250, 350, 450, and 550 mg/ml) and iodine (4, 12, 20, 28, 36, and 44 mg/ml) contrast elements were embedded into the glandular region of the phantoms. Calibration phantoms consisted of a 30/70 glandular-to-adipose tissue ratio with embedded HA (100, 200, 300, 400, and 500 mg/ml) and iodine (5, 15, 25, 35, and 45 mg/ml). The x-ray transport process was simulated where the Beer-Lambert law, Poisson process, and CZT absorption efficiency were applied. Qualitative and quantitative evaluations of the decomposition techniques were performed and compared. The effect of breast size was also investigated. Results: The first technique decomposed iodine adequately but failed for other materials. The second method separated the materials but was unable to quantify the materials. With the addition of a calibration, the third technique provided good separation and quantification of hydroxyapatite, iodine, glandular, and adipose tissues. Quantification with this technique was accurate with errors of 9.83% and 6.61% for HA and iodine, respectively. Calibration at one point (one breast size) showed increased errors as the mismatch in breast diameters between calibration and measurement increased. A four-point calibration successfully decomposed breast diameter spanning the entire range from 8 to 20 cm. For a 14 cm breast, errors were reduced from 5.44% to 1.75% and from 6.17% to 3.27% with the multipoint calibration for HA and iodine, respectively. Conclusions: The results of the simulation study showed that a CT system based on CZT detectors in conjunction with least squares minimization technique can be used to decompose four materials. The calibrated least squares parameter estimation decomposition technique performed the best, separating and accurately quantifying the concentrations of hydroxyapatite and iodine.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Quantification of LEU Holdup using gamma ray imaging and inverse transport solver

Holdup is the residual amount of special nuclear material (SNM) remaining in a processing facility after the bulk materials have been cleaned out. In commercial uranium processing facilities, quantification of holdup is a major challenge because of the highly variable shapes and sizes of the deposits. Any method that attempts to generalize and calibrate deposit shapes in order to quantify holdup will be prone to high uncertainties. Uncertainties on the order of ±50% are typical in holdup results. In international safeguards applications, a ±50% uncertainty can result in a large amount of material unaccounted for (MUF) thereby increasing the difficulty of detecting material diversion and facility misuse. An imaging-based methodology has been developed with the objective of significantly reducing this uncertainty by using the true deposit shape, instead of relying on oversimplified geometric assumptions. The project is a collaboration between ORNL, Y-12, and the University of Tennessee, Knoxville, TN. Uranium sources of known masses were measured using the Germanium Gamma-ray Imager (GeGI), a high-resolution imaging spectrometer, creating a pixelated map for each spectral bin. Two different gamma imaging methods are employed in this work: coded aperture imaging and Compton imaging. A validated MonteCarlo model of the detector has been developed using the GEANT4 code for determining the intrinsic response of the detector, its enclosure, and the coded aperture mask. An inverse transport solver based on the Markov Chain Monte-Carlo approach known as Differential Evolution Adaptive Metropolis (DREAM) is employed to use the measurement data from the image pixels (coded aperture or Compton) to solve for the mass of 235 U in the deposit. A reliable method based on the DREAM solver has been developed to flag the infinite thickness condition of a uranium deposit. The project team is working towards improving the image reconstruction for Compton imaging so that a better localization of the source can be achieved. Besides treating the coded aperture and Compton imaging methods independently, the project is also evaluating a combined method that uses the Compton scatter data from a coded aperture measurement. GEANT4 simulations are being performed to evaluate the combined approach. The impact on the DREAM optimization as the source thickness progressively approaches infinite thickness is being evaluated. A number of uranium sources available at ORNL have been measured, and the DREAM results have been tested and validated for the coded aperture imaging. A similar effort will be carried out to validate the Compton based method once the development of algorithms for better localization are complete. The imaging based quantification is very amenable to unattended monitoring of holdup accumulation at key measurement points. A proof of concept measurement has been completed to demonstrate this capability The current work used the high energy resolution imager GeGI. However, the approach and methodologies are applicable to other imagers such as the cadmium zin telluride (CZT) based imager manufactured by H3D, Inc.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

X-ray Phase Contrast Imaging of Calcified Tissue and Biomaterial Structure in Bioreactor Engineered Tissues

Tissues engineered in bioreactor systems have been used clinically to replace damaged tissues and organs. In addition, these systems are under continued development for many tissue engineering applications. The ability to quantitatively assess material structure and tissue formation is critical for evaluating bioreactor efficacy and for preimplantation assessment of tissue quality. These techniques allow for the nondestructive and longitudinal monitoring of large engineered tissues within the bioreactor systems and will be essential for the translation of these strategies to viable clinical therapies. X-ray Phase Contrast (XPC) imaging techniques have shown tremendous promise for a number of biomedical applications owing to their ability to provide image contrast based on multiple X-ray properties, including absorption, refraction, and scatter. In this research, mesenchymal stem cell-seeded alginate hydrogels were prepared and cultured under osteogenic conditions in a perfusion bioreactor. The constructs were imaged at various time points using XPC microcomputed tomography (µCT). Imaging was performed with systems using both synchrotron- and tube-based X-ray sources. XPC µCT allowed for simultaneous three-dimensional (3D) quantification of hydrogel size and mineralization, as well as spatial information on hydrogel structure and mineralization. Samples were processed for histological evaluation and XPC showed similar features to histology and quantitative analysis consistent with the histomorphometry. Furthermore, these results provide evidence of the significant potential of techniques based on XPC for noninvasive 3D imaging engineered tissues grown in bioreactors.

alginate microbeads↗

Dose, LET, time and strain dependence of radiation-induced 53BP1 foci in 15 mouse strains ex vivo and associations to in vivo radiation susceptibility

We present a comparative analysis on the repair of radiation-induced DNA damage ex vivo in 15 strains of mice, including 5 inbred reference strains and 10 collaborative-cross strains, of both sexes. Non-immortalized primary skin fibroblasts derived from 76 mice were subjected to both low- and high-LET radiation (0.1, 1 and 4 Gy of X rays; 1.1 and 3 particles/100μm2 of 350 MeV/n 40Ar and 600 MeV/n 56Fe). Automated image quantification of 53BP1 radiation-induced foci (RIF) during the first 4-48 h post-irradiation was performed as a function of dose and LET. Similarly to what we had previously reported for immortalized human cell lines [1], we observed a saturation of RIF number with dose at 4h post-irradiation, with more RIF/Gy for lower LET (X rays and 40Ar) compared to 56Fe. However at later time points (24h and above), the trend was inverted with more RIF/Gy for higher LET. Our data suggest that multiple DSBs cluster into RIF: as the linear density of DSBs increases with LET, so does the probability of having more DSBs per RIF, which makes it more difficult for cells to fully resolve high-LET-induced RIF, explaining the hypersensitivity to high-LET radiation despite a low number of RIF. Taking into account the amount of clustering at a given dose and LET, but also the kinetics of DNA damage repair, we introduced a novel mathematical formalism to evaluate the number of remaining RIF over time. We showed that the newly introduced kinetic metrics can be used as surrogate biomarkers for in vivo radiation toxicity, with potential applications in radiotherapy and human space exploration. In particular, we observed an association between the repairable fraction of RIF measured in vitro and survival levels of immune cells collected from irradiated mice. Moreover, the speed of DNA damage repair correlated with spontaneous cancer incidence data collected from the Mouse Tumor Biology database, suggesting a relationship between the efficiency of DSB repair after irradiation and cancer risk. In addition to the efficacy of repair and persistent RIF levels, even the amount of spontaneous foci without irradiation was shown to be strain dependent, indicating that these phenotypes are at least partially driven by genetics, and supporting their potential as indicators of individual radiation sensitivity. [1] Neumaier, T., et al., PNAS, 2012 (8) 109:443

Radiation, DNA damage, repair kinetics↗

TU-A-12A-12: Improved Airway Measurement Accuracy for Low Dose Quantitative CT (qCT) Using Statistical (ASIR), at Reduced DFOV, and High Resolution Kernels in a Phantom and Swine Model

Purpose: Quantitative accuracy of Iodine Hounsfield Unit (HU) in conventional single-kVp scanning is susceptible to beam-hardening effect. Dual-energy CT has unique capabilities of quantification using monochromatic CT images, but this scanning mode requires the availability of the state-of-the-art CT scanner and, therefore, is limited in routine clinical practice. Purpose of this work was to develop a beam-hardening-correction (BHC) for single-kVp CT that can linearize Iodine projections at any nominal energy, apply this approach to study Iodine response with respect to keV, and compare with dual-energy based monochromatic images obtained from material-decomposition using 80kVp and 140kVp. Methods: Tissue characterization phantoms (Gammex Inc.), containing solid-Iodine inserts of different concentrations, were scanned using GE multi-slice CT scanner at 80, 100, 120, and 140 kVp. A model-based BHC algorithm was developed where Iodine was estimated using re-projection of image volume and corrected through an iterative process. In the correction, the re-projected Iodine was linearized using a polynomial mapping between monochromatic path-lengths at various nominal energies (40 to 140 keV) and physically modeled polychromatic path-lengths. The beam-hardening-corrected 80kVp and 140kVp images (linearized approximately at effective energy of the beam) were used for dual-energy material-decomposition in Water-Iodine basis-pair followed by generation of monochromatic images. Characterization of Iodine HU and noise in the images obtained from singlekVp with BHC at various nominal keV, and corresponding dual-energy monochromatic images, was carried out. Results: Iodine HU vs. keV response from single-kVp with BHC and dual-energy monochromatic images were found to be very similar, indicating that single-kVp data may be used to create material specific monochromatic equivalent using modelbased projection linearization. Conclusion: This approach may enable quantification of Iodine contrast enhancement and potential reduction in injected contrast without using dual-energy scanning. However, in general, dual-energy scanning has unique value in material characterization and quantification, and its value cannot be discounted. GE Healthcare Employee.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Evaluation of partial volume correction and analysis of longitudinal [ 18 F]GTP1 tau PET imaging in Alzheimer's disease using linear mixed-effects models

Purpose: We evaluated the impact of partial volume correction (PVC) methods on the quantification of longitudinal [ 18 F]GTP1 tau positron-emission tomography (PET) in Alzheimer's disease and the suitability of describing the tau pathology burden temporal trajectories using linear mixed-effects models (LMEM). Methods: We applied van Cittert iterative deconvolution (VC), 2-compartment, and 3-compartment, and the geometric transfer matrix plus region-based voxelwise methods to data acquired in an Alzheimer's disease natural history study over 18 months at a single imaging site. We determined the optimal PVC method by comparing the standardized uptake value ratio change (%ΔSUVR) between diagnostic and tau burden–level groups and the longitudinal repeatability derived from the LMEM. The performance of LMEM analysis for calculating %ΔSUVR was evaluated in a natural history study and in a multisite clinical trial of semorinemab in prodromal to mild Alzheimer's disease by comparing results to traditional per-visit estimates. Results: The VC, 2-compartment, and 3-compartment PVC methods had similar performance, whereas region-based voxelwise overcorrected regions with a higher tau burden. The lowest within-subject variability and acceptable group separation scores were observed without PVC. The LMEM-derived %ΔSUVR values were similar to the per-visit estimates with lower variability. Conclusion: The results indicate that the tested PVC methods do not offer a clear advantage or improvement over non-PVC images for the quantification of longitudinal [ 18 F]GTP1 PET data. LMEM offers a robust framework for the longitudinal tau PET quantification with low longitudinal test–retest variability. Clinical trial registration: NCT02640092 and NCT03289143.

60 APPLIED LIFE SCIENCES↗

Multivariate statistics applications in phase analysis of STEM-EDS spectrum images

Spectrum imaging (SI) methods are displacing traditional spot analyses as the predominant paradigm for spectroscopic analysis with electron beam instrumentation. The multivariate nature of SI provides clear advantages for qualitative analysis of multiphase specimens relative to traditional gray-scale images acquired with non-spectroscopic signals, where different phases with similar average atomic number may exhibit the same intensity. However, with the improvement in qualitative analysis with the SI paradigm has come a decline in the quantitative analysis of the phases thus identified, since the spectra from individual pixels typically have insufficient counting statistics for proper quantification. The present paper outlines a methodology for quantitative analysis within the spectral imaging paradigm, which is illustrated through X-ray energy-dispersive spectroscopy (EDS) of a multiphase (Pb,La)(Zr,Ti)O{sub 3} ceramic in scanning transmission electron microscopy (STEM). Statistical analysis of STEM-EDS SI is shown to identify the number of distinct phases in the analyzed specimen and to provide better segmentation than the STEM high-angle annular dark-field (HAADF) signal. Representative spectra for the identified phases are extracted from the segmented images with and without exclusion of pixels that exhibit spectral contributions from multiple phases, and subsequently quantified using Cliff-Lorimer sensitivity factors. The phase compositions extracted with the method while excluding pixels from multiple phases are found to be in good agreement with those extracted from user-selected regions of interest, while providing improved confidence intervals. Without exclusion of multiphase pixels, the extracted composition is found to be in poor statistical agreement with the other results because of systematic errors arising from the cross-phase spectral contamination. The proposed method allows quantification to be performed in the presence of discontinuous phase distributions and overlapping phases, challenges that are typical of many nanoscale analyses performed by STEM-EDS.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

SU-G-JeP2-12: Quantification of 3D Geometric Distortion for 1.5T and 3T MRI Scanners Used for Radiation Therapy

Purpose: To quantify the magnitude of geometric distortion for MRI scanners and provide recommendations for MRI imaging for radiation therapy Methods: A novel phantom, QUASAR MRID3D [Modus Medical Devices Inc.], was scanned to evaluate the level of 3D geometric distortion present in five MRI scanners used for radiation therapy in our department. The phantom was scanned using the body coil with 1mm image slice thickness to acquire 3D images of the phantom body. The phantom was aligned to its geometric center for each scan, and the field of view was set to visualize the entire phantom. The dependence of distortion magnitude with distance from imaging isocenter and with magnetic field strength (1.5T and 3T) was investigated. Additionally, the characteristics of distortion for Siemens and GE machines were compared. The image distortion for each scanner was quantified in terms of mean, standard deviation (STD), maximum distortion, and skewness. Results: The 3T and 1.5T scans show a similar absolute distortion with a mean of 1.38mm (0.33mm STD) for 3T and 1.39mm (0.34mm STD) for 1.5T for a 100mm radius distance from isocenter. Some machines can have a distortion larger than 10mm at a distance of 200mm from the isocenter. The distortions are presented with plots of the x, y, and z directional components. Conclusion: The results indicate that quantification of MRI image distortion is crucial in radiation oncology for target and organ delineation and treatment planning. The magnitude of geometric distortion determines the margin needed for target contouring which is usually neglected in treatment planning process, especially for SRS/SBRT treatments. Understanding the 3D distribution of the MRI image distortion will improve the accuracy of target delineation and, hence, treatment efficacy. MRI imaging with proper patient alignment to the isocenter is vital to reducing the effects of MRI distortion in treatment planning.

60 APPLIED LIFE SCIENCES↗

FIRM image analysis: A machine learning workflow for quantifying extracellular matrix components from electron microscopy images

The extracellular matrix (ECM) is a complex network of biomolecules that plays an integral role in the structure, processes, and signaling mechanisms of cells and tissues. Identifying and quantifying changes in these matrix components provides insight into the mechanisms behind specific tissue remodeling processes; however, quantifying these changes is challenging due to difficult imaging conditions, complexity of the ECM, and the subtlety of these changes. Current imaging techniques allow us to visualize these critical remodeling events and developments in image analysis have employed a combination of analysis software and machine learning techniques to improve the efficiency and accuracy with which features are measured. Although image analysis has seen much improvement in recent years, there has been no technique developed to address ambiguity in feature edges in electron microscopy images. Presented here is a new machine learning-based workflow for the analysis of microscopy images named FIRM (Feature Identification from Raw Microscopy) that uses a random forest classifier to identify ECM features of interest and generate binary segmentation masks for quantification with ImageJ-FIJI. FIRM performed with an F1 score of 0.794 and greater than 80% accuracy for number and size of features detected. FIRM had similar deviation from the ground truth in the number of identified fibrils, fibril size, and size distributions when compared to human analyses. The results suggest that FIRM performs as well as manual analysis and requires a fraction of the time. This analysis technique is more efficient, eliminates user bias, and can be easily optimized to identify a variety of features, making it useful for any discipline requiring image analysis.

Science & Technology - Other Topics↗

Evaluation of similarity measures for use in the intensity-based rigid 2D-3D registration for patient positioning in radiotherapy

Purpose: Rigid 2D-3D registration is an alternative to 3D-3D registration for cases where largely bony anatomy can be used for patient positioning in external beam radiation therapy. In this article, the authors evaluated seven similarity measures for use in the intensity-based rigid 2D-3D registration using a variation in Skerl's similarity measure evaluation protocol. Methods: The seven similarity measures are partitioned intensity uniformity, normalized mutual information (NMI), normalized cross correlation (NCC), entropy of the difference image, pattern intensity (PI), gradient correlation (GC), and gradient difference (GD). In contrast to traditional evaluation methods that rely on visual inspection or registration outcomes, the similarity measure evaluation protocol probes the transform parameter space and computes a number of similarity measure properties, which is objective and optimization method independent. The variation in protocol offers an improved property in the quantification of the capture range. The authors used this protocol to investigate the effects of the downsampling ratio, the region of interest, and the method of the digitally reconstructed radiograph (DRR) calculation [i.e., the incremental ray-tracing method implemented on a central processing unit (CPU) or the 3D texture rendering method implemented on a graphics processing unit (GPU)] on the performance of the similarity measures. The studies were carried out using both the kilovoltage (kV) and the megavoltage (MV) images of an anthropomorphic cranial phantom and the MV images of a head-and-neck cancer patient. Results: Both the phantom and the patient studies showed the 2D-3D registration using the GPU-based DRR calculation yielded better robustness, while providing similar accuracy compared to the CPU-based calculation. The phantom study using kV imaging suggested that NCC has the best accuracy and robustness, but its slow function value change near the global maximum requires a stricter termination condition for an optimization method. The phantom study using MV imaging indicated that PI, GD, and GC have the best accuracy, while NCC and NMI have the best robustness. The clinical study using MV imaging showed that NCC and NMI have the best robustness. Conclusions: The authors evaluated the performance of seven similarity measures for use in 2D-3D image registration using the variation in Skerl's similarity measure evaluation protocol. The generalized methodology can be used to select the best similarity measures, determine the optimal or near optimal choice of parameter, and choose the appropriate registration strategy for the end user in his specific registration applications in medical imaging.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Atomic-Scale Chemical Imaging and Quantification of Metallic Alloy Structures by Energy-Dispersive X-Ray Spectroscopy

Determination of atomic-scale crystal structure for nanostructured intermetallic alloys, such as magnetic alloys containing Al, Ni, Co (alnico) and Fe, is crucial for understanding physical properties such as magnetism, but technically challenging due to the small interatomic distances and the similar atomic numbers. By applying energy-dispersive X-ray spectroscopy (EDS) mapping to the study of two intermetallic phases of an alnico alloy resulting from spinodal decomposition, we have determined atomic-scale chemical composition at individual lattice sites for the two phases: one is the B2 phase with Fe0.76Co0.24 -Fe0.40Co0.60 ordering and the other is the L21 phase with Ni0.48Co0.52 at A-sites, Al at BΙ-sites and Fe0.20Ti0.80 at BΙΙ-sites, respectively. The technique developed through this study represents a powerful real-space approach to investigate structure chemically at the atomic scale for a wide range of materials systems.

36 MATERIALS SCIENCE↗