Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “image collection simulation”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Image Collection Simulation Using High-Resolution Atmospheric Modeling

A new method is described for simulating the passive remote sensing image collection of ground targets that includes effects from atmospheric physics and dynamics at fine spatial and temporal scales. The innovation in this research is the process of combining a high-resolution weather model with image collection simulation to attempt to account for heterogeneous and high-resolution atmospheric effects on image products. The atmosphere was modeled on a 3D voxel grid by a Large-Eddy Simulation (LES) driven by forcing data constrained by local ground-based and air-based observations. The spatial scale of the atmospheric model (10–100 m) came closer than conventional weather forecast scales (10–100 km) to approaching the scale of typical commercial multispectral imagery (2 m). This approach was demonstrated through a ground truth experiment conducted at the Department of Energy Atmospheric Radiation Measurement Southern Great Plains site. In this experiment, calibrated targets (colored spectral tarps) were placed on the ground, and the scene was imaged with WorldView-3 multispectral imagery at a resolution enabling the tarps to be visible in at least 9–12 image pixels. The image collection was simulated with Digital Imaging and Remote Sensing Image Generation (DIRSIG) software, using the 3D atmosphere from the LES model to generate a high-resolution cloud mask. The high-resolution atmospheric model-predicted cloud coverage was usually within 23% of the measured cloud cover. The simulated image products were comparable to the WorldView-3 satellite imagery in terms of the variations of cloud distributions and spectral properties of the ground targets in clear-sky regions, suggesting the potential utility of the proposed modeling framework in improving simulation capabilities, as well as testing and improving the operation of image collection processes.

54 ENVIRONMENTAL SCIENCES↗

Holistic Interactions of Shallow Clouds, Aerosols, and Land-Ecosystems (HI-SCALE): National Geospatial-Intelligence Agency Calibration Target Placements Field Campaign Report

The purpose of our research has been to develop a capability of simulating image collection from any sensor so as to account for sensor configuration, ground spectral radiance, and atmospheric contributions. Atmosphere is arguably the most difficult aspect of the image pipeline to accurately characterize and integrate into an image simulation. Some of the reasons for this include the highly variable spatial content of different absorbing and scattering species in the atmosphere. Additionally, the interaction of land and atmosphere can significantly impact the total radiation budget, especially in the southern Great Plains.

54 ENVIRONMENTAL SCIENCES↗

Simulation of dose reduction in tomosynthesis

Purpose: Methods for simulating dose reduction are valuable tools in the work of optimizing radiographic examinations. Using such methods, clinical images can be simulated to have been collected at other, lower, dose levels without the need of additional patient exposure. A recent technology introduced to healthcare that needs optimization is tomosynthesis, where a number of low-dose projection images collected at different angles is used to reconstruct section images of an imaged object. The aim of the present work was to develop a method of simulating dose reduction for digital radiographic systems, suitable for tomosynthesis. Methods: The developed method uses information about the noise power spectrum (NPS) at the original dose level and the simulated dose level to create a noise image that is added to the original image to produce an image that has the same noise properties as an image actually collected at the simulated dose level. As the detective quantum efficiency (DQE) of digital detectors operating at the low dose levels used for tomosynthesis may show a strong dependency on the dose level, it is important that a method for simulating dose reduction for tomosynthesis takes this dependency into account. By applying an experimentally determined relationship between pixel mean and pixel variance, variations in both dose and DQE in relevant dose ranges are taken into account. Results: The developed method was tested on a chest tomosynthesis system and was shown to produce NPS of simulated dose-reduced projection images that agreed well with the NPS of images actually collected at the simulated dose level. The simulated dose reduction method was also applied to tomosynthesis examinations of an anthropomorphic chest phantom, and the obtained noise in the reconstructed section images was very similar to that of an examination actually performed at the simulated dose level. Conclusions: In conclusion, the present article describes a method for simulating dose reduction suitable for tomosynthesis. However, the method applies equally well to any digital radiographic system, although the benefits of correcting for DQE variations may be smaller.

61 RADIATION PROTECTION AND DOSIMETRY↗

Gamma Imaging and Mapping Advancements

The SRNL developed GrayQb{sup TM} gamma mapping system has been successfully deployed in field situations. Currently, to get the image from the GrayQb{sup TM} the internal Phosphor Storage Plate (PSP) used to capture radiation images must be recovered and scanned by a ScanX Scanner. Upgrades are being implemented which will enable the GrayQB{sup TM} to read the PSP using a camera and red LEDs then transmit results to a remote location. This will greatly reduce personnel interaction, increasing safety as well as eliminating the need for the ScanX. Upgrades have been based off of the MiniMax, a Los Alamos National Laboratory developed PSP reading device constructed with a Nikon DSLR and a red LED flash to obtain the images from the PSP. The electronics in the upgraded GrayQb{sup TM} need to be both functional and environmentally rugged. A PC/104 was chosen for its wider operational temperature range and its physical durability. The Sony α7 ii and the Mightex are the candidate cameras for the upgrades based on test results. PSPs were exposed to gamma radiation sources at SRS's Health Physics Instrumentation Calibration Laboratory (HPICL). PSPs were tested with both Am-241 and Cs-137. Linear intensity increased with dose verifying UV image simulations. Data collected enabled the PSP intensity to be referenced to a total dose. Further work includes design and implementation of a 3D printed housing for the new camera system. The housing will include the camera, light flash, PSP holders, tungsten dual pinhole, PC/104, dosimeter, and a battery or tethering option. Once the housing is finalized further testing at the HPICL facility is planned for early August. During this testing, the final housing design will capture both Am-241 and Cs-137 images.

3D PRINTING↗

A hybrid approach to estimate the complex motions of clouds in sky images

Tracking the motion of clouds is essential to forecasting the weather and to predicting the short-term solar energy generation. Existing techniques mainly fall into two categories: variational optical flow, and block matching. In this article, we summarize recent advances in estimating cloud motion using ground-based sky imagers and quantitatively evaluate state-of-the-art approaches. Then we propose a hybrid tracking framework to incorporate the strength of both block matching and optical flow models. To validate the accuracy of the proposed approach, we introduce a series of synthetic images to simulate the cloud movement and deformation, and thereafter comprehensively compare our hybrid approach with several representative tracking algorithms over both simulated and real images collected from various sites/imagers. The results show that our hybrid approach outperforms state-of-the-art models by reducing at least 30% motion estimation errors compared with the ground-truth motions in most of simulated image sequences. Furthermore, our hybrid model demonstrates its superior efficiency in several real cloud image datasets by lowering at least 15% Mean Absolute Error (MAE) between predicted images and ground-truth images.

54 ENVIRONMENTAL SCIENCES↗

TU-F-CAMPUS-T-05: Replacement Computational Phantoms to Estimate Dose in Out-Of-Field Organs and Tissues

Purpose: To estimate the absorbed dose in organs and tissues at risk for radiogenic cancer for children receiving photon radiotherapy for localized brain tumors (LBTs) by supplementing their missing body anatomies with those of replacement computational phantoms. Applied beyond the extent of the RT Images collected by computed tomography simulation, these phantoms included RT Image and RT Structure Set objects that encompassed sufficient extents and contours for dosimetric calculations. Method: Nine children, aged 2 to 14 years, who received three-dimensional conformal radiotherapy for low-grade LBTs, were randomly selected for this study under Institutional-Review-Board protocol. Because the extents of their RT Images were cranial only, they were matched for size and sex with patients from a previous study with larger extents and for whom contours of organs at risk for radiogenic cancer had already been delineated. Rigid fusion was performed between the patients’ data and those of the replacement computational phantoms using commercial software. In-field dose was calculated with a clinically-commissioned treatment planning system, and out-of-field dose was estimated with an analytical model. Results: Averaged over all nine children and normalized for a therapeutic dose of 54 Gy prescribed to the PTV, where the PTV is the GTV, the highest mean organ doses were 3.27, 2.41, 1.07, 1.02, 0.24, and 0.24 Gy in the non-tumor remainder, red bone marrow, thyroid, skin, breasts, and lungs, respectively. The mean organ doses ranged by a factor of 3 between the smallest and largest children. Conclusion: For children receiving photon radiotherapy for LBTs, we found their doses in organs at risk for second cancer to be non-negligible, especially in the non-tumor remainder, red bone marrow, thyroid, skin, breasts, and lungs. This study demonstrated the feasibility for patient dosimetry studies to augment missing patient anatomy by applying size- and sex-matched replacement computational phantoms with pre-contoured organs. Funding is in part by the Fogarty International Center award K01TW008409, and the Portland Chapter of the Achievement Rewards for College Scientists. The content is solely the responsibility of the authors, and does not necessarily represent the official views of the sponsors. The authors declare no conflict of interest.

60 APPLIED LIFE SCIENCES↗

Simulation of pseudo-CT images based on deformable image registration of ultrasound images: A proof of concept for transabdominal ultrasound imaging of the prostate during radiotherapy

Purpose: Imaging of patient anatomy during treatment is a necessity for position verification and for adaptive radiotherapy based on daily dose recalculation. Ultrasound (US) image guided radiotherapy systems are currently available to collect US images at the simulation stage (US{sub sim}), coregistered with the simulation computed tomography (CT), and during all treatment fractions. The authors hypothesize that a deformation field derived from US-based deformable image registration can be used to create a daily pseudo-CT (CT{sub ps}) image that is more representative of the patients’ geometry during treatment than the CT acquired at simulation stage (CT{sub sim}). Methods: The three prostate patients, considered to evaluate this hypothesis, had coregistered CT and US scans on various days. In particular, two patients had two US–CT datasets each and the third one had five US–CT datasets. Deformation fields were computed between pairs of US images of the same patient and then applied to the corresponding US{sub sim} scan to yield a new deformed CT{sub ps} scan. The original treatment plans were used to recalculate dose distributions in the simulation, deformed and ground truth CT (CT{sub gt}) images to compare dice similarity coefficients, maximum absolute distance, and mean absolute distance on CT delineations and gamma index (γ) evaluations on both the Hounsfield units (HUs) and the dose. Results: In the majority, deformation did improve the results for all three evaluation methods. The change in gamma failure for dose (γ{sub Dose}, 3%, 3 mm) ranged from an improvement of 11.2% in the prostate volume to a deterioration of 1.3% in the prostate and bladder. The change in gamma failure for the CT images (γ{sub CT}, 50 HU, 3 mm) ranged from an improvement of 20.5% in the anus and rectum to a deterioration of 3.2% in the prostate. Conclusions: This new technique may generate CT{sub ps} images that are more representative of the actual patient anatomy than the CT{sub sim} scan.

60 APPLIED LIFE SCIENCES↗

Towards an improved LAI collection protocol via simulated field-based PAR sensing

In support of NASA’s next-generation spectrometer—the Hyperspectral Infrared Imager (HyspIRI)—we are working towards assessing sub-pixel vegetation structure from imaging spectroscopy data. Of particular interest is Leaf Area Index (LAI), which is an informative, yet notoriously challenging parameter to efficiently measure in situ. While photosynthetically-active radiation (PAR) sensors have been validated for measuring crop LAI, there is limited literature on the efficacy of PAR-based LAI measurement in the forest environment. This study (i) validates PAR-based LAI measurement in forest environments, and (ii) proposes a suitable collection protocol, which balances efficiency with measurement variation, e.g., due to sun flecks and various-sized canopy gaps. A synthetic PAR sensor model was developed in the Digital Imaging and Remote Sensing Image Generation (DIRSIG) model and used to validate LAI measurement based on first-principles and explicitly-known leaf geometry. Simulated collection parameters were adjusted to empirically identify optimal collection protocols. Furthermore, these collection protocols were then validated in the field by correlating PAR-based LAI measurement to the normalized difference vegetation index (NDVI) extracted from the “classic” Airborne Visible Infrared Imaging Spectrometer (AVIRIS-C) data (R 2 was 0.61). The results indicate that our proposed collecting protocol is suitable for measuring the LAI of sparse forest (LAI < 3–5 ( m 2 /m 2 )).

47 OTHER INSTRUMENTATION↗

Attenuation-based size metric for estimating organ dose to patients undergoing tube current modulated CT exams

Purpose: Task Group 204 introduced effective diameter (ED) as the patient size metric used to correlate size-specific-dose-estimates. However, this size metric fails to account for patient attenuation properties and has been suggested to be replaced by an attenuation-based size metric, water equivalent diameter (D{sub W}). The purpose of this study is to investigate different size metrics, effective diameter, and water equivalent diameter, in combination with regional descriptions of scanner output to establish the most appropriate size metric to be used as a predictor for organ dose in tube current modulated CT exams. Methods: 101 thoracic and 82 abdomen/pelvis scans from clinically indicated CT exams were collected retrospectively from a multidetector row CT (Sensation 64, Siemens Healthcare) with Institutional Review Board approval to generate voxelized patient models. Fully irradiated organs (lung and breasts in thoracic scans and liver, kidneys, and spleen in abdominal scans) were segmented and used as tally regions in Monte Carlo simulations for reporting organ dose. Along with image data, raw projection data were collected to obtain tube current information for simulating tube current modulation scans using Monte Carlo methods. Additionally, previously described patient size metrics [ED, D{sub W}, and approximated water equivalent diameter (D{sub Wa})] were calculated for each patient and reported in three different ways: a single value averaged over the entire scan, a single value averaged over the region of interest, and a single value from a location in the middle of the scan volume. Organ doses were normalized by an appropriate mAs weighted CTDI{sub vol} to reflect regional variation of tube current. Linear regression analysis was used to evaluate the correlations between normalized organ doses and each size metric. Results: For the abdominal organs, the correlations between normalized organ dose and size metric were overall slightly higher for all three differently (global, regional, and middle slice) reported D{sub W} and D{sub Wa} than they were for ED, but the differences were not statistically significant. However, for lung dose, computed correlations using water equivalent diameter calculated in the middle of the image data (D{sub W,middle}) and averaged over the low attenuating region of lung (D{sub W,regional}) were statistically significantly higher than correlations of normalized lung dose with ED. Conclusions: To conclude, effective diameter and water equivalent diameter are very similar in abdominal regions; however, their difference becomes noticeable in lungs. Water equivalent diameter, specifically reported as a regional average and middle of scan volume, was shown to be better predictors of lung dose. Therefore, an attenuation-based size metric (water equivalent diameter) is recommended because it is more robust across different anatomic regions. Additionally, it was observed that the regional size metric reported as a single value averaged over a region of interest and the size metric calculated from a single slice/image chosen from the middle of the scan volume are highly correlated for these specific patient models and scan types.

60 APPLIED LIFE SCIENCES↗

SU-D-9A-03: STAMP: Simulator for Texture Analysis in MRI/PET

Purpose: To develop a convenient simulation platform to facilitate PET/MR image analysis with the prospect of gaining a better understanding of the influence of acquisition parameters on PET/MRI textural features. The simulation platform is demonstrated by showing textural variations of a representative case study using different image acquisition parameters. Methods: The simulation platform is composed of MRI simulators JEMRIS and SIMRI to achieve simulations of customized MRI sequences on sample tumor models. The PET simulator GATE is used to get 2D and 3D Monte Carlo acquisitions of voxelized PET sources using a phantom geometry and a customized scanner architecture. The platform incorporates a series of graphical user interfaces written in Matlab. Two GUIs are used to facilitate communication with the simulation executables installed on a computer cluster. A third GUI is used to collect and display the clinical and simulated images, as well as fused PET/MRI images, and perform computation of textural features.To illustrate the capabilities of this platform, one FDG-PET and T1-weighted (T1w) digitized tumor models were generated from clinical images of a soft-tissue sarcoma patient. Numerically simulated MR images were produced using 3 different echo times (TE) and 5 different repetition times (TR). PET 2D images were simulated using an OSEM algorithm with 1 to 32 iterations and a post-reconstruction Gaussian filter of 0, 2, 4 or 6 mm width. Results: STAMP was successfully used to produce numerically simulated FDG-PET and MRI images, and to calculate their corresponding textures. Three typical textures (GLCM-Contrast, GLSZM-ZSV and NGTDM-Coarseness) were found to vary by a range of 45% on average compared to reference scanning conditions in the case of FDG-PET, and by a range of 40% in the case of T1w MRI. Conclusion: We have successfully developed a Matlab-based simulation platform to facilitate PET/MRI texture image analysis for outcome prediction.

60 APPLIED LIFE SCIENCES↗

Regional surrogates for predictive control of digital twins

Digital twins of complex systems must involve a model that is fast, generalizable, and usable for real-time control. For example, high-fidelity nonlinear multiphysics simulations can capture laser-material interactions, but are too slow for optimization or model predictive control (MPC). Reduced-order models, used to accelerate such computation, frequently fail to generalize to unseen inputs or control states. We show theoretically that this failure is intrinsic, i.e., that a learned model is non-unique outside the sampled subspace when its low-rank structure arises from limited excitation and clustered eigenvalues, rather than from a user-imposed truncation alone. Motivated by this result, we propose a control-ready regional surrogate-construction framework for both autonomous and nonautonomous dynamics; it employs Koopman lifting to represent nonlinearities, while preserving spatial locality. We illustrate our approach by constructing a control-ready surrogate for the digital twin of a thermal component of additive-manufacturing process. Our surrogate, localized in space through a von Neumann stencil, is learned from noisy high-fidelity simulations that emulate thermal-camera images collected during the manufacturing. It is linear in thermo-physically augmented states so that MPC reduces to a convex quadratic program. The surrogate requires no online correction, generalizes to unseen scan paths and power profiles of the laser, and is more than three orders of magnitude faster than a finite-difference solver. Furthermore, when the MPC sequence computed on the digital twin is applied to this solver, closed-loop temperature regulation is recovered, showing that the surrogate preserves control-relevant input-output behavior.

Data-driven model↗

Quasiaperiodic grain boundary phases of Σ⁢5 tilt grain boundaries in refractory metals

We report ground-state structures and phase transitions in Σ⁢5⁢[001] tilt grain boundaries (GBs) in body-centered-cubic (bcc) refractory metals Nb, Ta, Mo, and W. Σ⁢5 tilt GBs have been extensively investigated over the past several decades, with their ground-state structure—composed of kite-shaped structural units—previously thought to be well understood. By performing a rigorous GB structure search that optimizes the number of atoms in the boundary core, we predict different quasiaperiodic “split kite” phases analogous to those previously found in GBs in face-centered-cubic metals. Furthermore, our results suggest that complex aperiodic phases of GBs appear to be a general phenomenon, as validated through density functional theory calculations. Moreover, the atoms in the split kite phase demonstrate distinct collective diffusion dynamics. Phase-contrast image simulations of split kites show better agreement with experimental observations, offering an alternative explanation for previous microscopy results and motivating future atomically resolved imaging of the GB structure.

Body-centered cubic↗

Correlation of Injury Simulation with Clinical Assessment of Traumatic Brain Injury

This report contains a summary of our efforts to correlate head injury simulations predicting intracranial fluid cavitation with clinical assessments of brain injury from blunt impact to the head. Magnetic resonance imaging (MRI) data, collected on traumatic brain injury (TBI) subjects by researchers at the MIND Institute of New Mexico, was acquired for the current work. Specific blunt impact TBI case histories were selected from the TBI data for further study and possible correlation with simulation. Both group and single-subject case histories were examined. We found one single-subject case that was particularly suited for correlation with simulation. Diffusion tensor image (DTI) analysis of the TBI subject identified white matter regions within the brain displaying reductions in fractional anisotropy (FA), an indicator of local damage to the white matter axonal structures. Analysis of functional magnetic resonance image (fMRI) data collected on this individual identified localized regions of the brain displaying hypoactivity, another indicator of brain injury. We conducted high fidelity simulations of head impact experienced by the TBI subject using the Sandia head-neck-torso model and the shock physics computer code CTH. Intracranial fluid cavitation predictions were compared with maps of DTI fractional anisotropy and fMRI hypoactivity to assess whether a possible correlation exists. The ultimate goal of this work is to assess whether one can correlate simulation predictions of intracranial fluid cavitation with the brain injured sites identified by the fMRI and DTI analyses. The outcome of this effort is described in this report.

59 BASIC BIOLOGICAL SCIENCES↗

Correlation of Injury Simulation with Clinical Assessment of Traumatic Brain Injury

This report contains a summary of our efforts to correlate head injury simulations predicting intracranial fluid cavitation with clinical assessments of brain injury from blunt impact to the head. Magnetic resonance imaging (MRI) data, collected on traumatic brain injury (TBI) subjects by researchers at the MIND Institute of New Mexico, was acquired for the current work. Specific blunt impact TBI case histories were selected from the TBI data for further study and possible correlation with simulation. Both group and single-subject case histories were examined. We found one single-subject case that was particularly suited for correlation with simulation. Diffusion tensor image (DTI) analysis of the TBI subject identified white matter regions within the brain displaying reductions in fractional anisotropy (FA), an indicator of local damage to the white matter axonal structures. Analysis of functional magnetic resonance image (fMRI) data collected on this individual identified localized regions of the brain displaying hypoactivity, another indicator of brain injury. We conducted high fidelity simulations of head impact experienced by the TBI subject using the Sandia head-neck-torso model and the shock physics computer code CTH. Intracranial fluid cavitation predictions were compared with maps of DTI fractional anisotropy and fMRI hypoactivity to assess whether a possible correlation exists. The ultimate goal of this work is to assess whether one can correlate simulation predictions of intracranial fluid cavitation with the brain injured sites identified by the fMRI and DTI analyses. The outcome of this effort is described in this report.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Image quality comparison between single energy and dual energy CT protocols for hepatic imaging

Purpose: Multi-detector computed tomography (MDCT) enables volumetric scans in a single breath hold and is clinically useful for hepatic imaging. For simple tasks, conventional single energy (SE) computed tomography (CT) images acquired at the optimal tube potential are known to have better quality than dual energy (DE) blended images. However, liver imaging is complex and often requires imaging of both structures containing iodinated contrast media, where atomic number differences are the primary contrast mechanism, and other structures, where density differences are the primary contrast mechanism. Hence it is conceivable that the broad spectrum used in a dual energy acquisition may be an advantage. In this work we are interested in comparing these two imaging strategies at equal-dose and more complex settings. Methods: We developed numerical anthropomorphic phantoms to mimic realistic clinical CT scans for medium size and large size patients. MDCT images based on the defined phantoms were simulated using various SE and DE protocols at pre- and post-contrast stages. For SE CT, images from 60 kVp through 140 with 10 kVp steps were considered; for DE CT, both 80/140 and 100/140 kVp scans were simulated and linearly blended at the optimal weights. To make a fair comparison, the mAs of each scan was adjusted to match the reference radiation dose (120 kVp, 200 mAs for medium size patients and 140 kVp, 400 mAs for large size patients). Contrast-to-noise ratio (CNR) of liver against other soft tissues was used to evaluate and compare the SE and DE protocols, and multiple pre- and post-contrasted liver-tissue pairs were used to define a composite CNR. To help validate the simulation results, we conducted a small clinical study. Eighty-five 120 kVp images and 81 blended 80/140 kVp images were collected and compared through both quantitative image quality analysis and an observer study. Results: In the simulation study, we found that the CNR of pre-contrast SE image mostly increased with increasing kVp while for post-contrast imaging 90 kVp or lower yielded higher CNR images, depending on the differential iodine concentration of each tissue. Similar trends were seen in DE blended CNR and those from SE protocols. In the presence of differential iodine concentration (i.e., post-contrast), the CNR curves maximize at lower kVps (80–120), with the peak shifted rightward for larger patients. The combined pre- and post-contrast composite CNR study demonstrated that an optimal SE protocol has better performance than blended DE images, and the optimal tube potential for SE scan is around 90 kVp for a medium size patients and between 90 and 120 kVp for large size patients (although low kVp imaging requires high x-ray tube power to avoid photon starvation). Also, a tin filter added to the high kVp beam is not only beneficial for material decomposition but it improves the CNR of the DE blended images as well. The dose adjusted CNR of the clinical images also showed the same trend and radiologists favored the SE scans over blended DE images. Conclusions: Our simulation showed that an optimized SE protocol produces up to 5% higher CNR for a range of clinical tasks. The clinical study also suggested 120 kVp SE scans have better image quality than blended DE images. Hence, blended DE images do not have a fundamental CNR advantage over optimized SE images.

60 APPLIED LIFE SCIENCES↗

Simulations of muon imaging with the LANL GMT detector for spent nuclear fuel cask content verification

Atmospheric muons are typically high energy, highly penetrating charged particles. They interact with matter primarily through multiple Coulomb scatterings. Muon scattering intensities can be used to characterize the density and atomic number of the matter that they pass through. Previously, the Los Alamos National Laboratory (LANL) muon tomography team performed muon imaging of the partially filled MC-10 spent nuclear fuel (SNF) cask at Idaho National Laboratory (INL). This experiment demonstrated the feasibility of muon imaging for the verification of spent fuel container contents. That original effort used the mini muon tracker array, consisting of two arrays of drift tubes on either side of the SNF cask. The reconstructed image quality was limited by statistics, largely due to low muon flux at high zenith angles. A LANL led team will perform new measurements with a larger array, the Giant Muon Tracker (GMT), to improve data collection rates and statistics. In this work, simulations were performed with the GMT near the partially filled INL MC-10 cask. For more general fuel diversion detection, a full MC-10 cask and casks with a singular missing fuel bundle were also simulated. To understand minimum measurement times needed for missing bundle identification, 100 000 to millions of tracked muons (corresponding to 1.4 days to several weeks measurement time) were analyzed. Simulated images were then analyzed visually and numerically to explore techniques designed to minimize the collection time needed to identify the diversion of fuel in each scenario.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Characterization of the atomic-level structure of γ-alumina and (111) Pt/γ-alumina interfaces

The atomic-level structure of platinum/γ-alumina interfaces is characterized in a model system of dense γ-alumina embedded with faceted Pt NPs produced by implantation of platinum ions into sapphire followed by thermal annealing in air at 800 °C. Aberration-corrected scanning transmission electron microscopy (STEM) was used to collect atomic-resolution images, which are compared to STEM image simulations of two experimentally-based bulk models of γ-alumina by Smrčok et al. and Zhou and Snyder. A density functional theory (DFT) based model of (111) interfaces with different chemical terminations (O, Al 1 , Al 2 ) of the γ-alumina developed by Oware Sarfo et al. is also compared to experimental STEM data from Pt/γ-alumina interfaces. Further, the Smrčok γ-alumina model provides a better fit than the Zhou structure to the bulk of the γ-alumina. The oxygen-terminated Oware Sarfo model best fits the experimental data and is a very good model close to the interface. However, the fit of the interface model to the experimental data is poorer beyond the third atomic layer in the γ-alumina. This is attributed to compromises required in the design of the model to limit the cell size and computational time for DFT calculations. Understanding the accuracy and limits of the structural models of γ-alumina and Pt/γ-alumina interfaces is important to further the understanding of the structure/property relationships in this system.

36 MATERIALS SCIENCE↗