Engineering PapersSearch

SEARCH · Engineering Papers

Results for “hyperpolarization”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Efficient 15 N hyperpolarization of [ 15 N 3 ]metronidazole antibiotic via spin-relayed pulsed SABRE-SHEATH

Signal Amplification by Reversible Exchange in SHield Enables Alignment Transfer to Heteronuclei (SABRE-SHEATH) is an NMR hyperpolarization technique that relies of the simultaneous exchange of parahydrogen and a to-be-hyperpolarized molecule on the metal center of a polarization-transfer catalyst in a microtesla magnetic field. Until recently, this method has been understood to perform hyperpolarization by establishing level anti-crossings between the nuclear spins of the parahydrogen derived hydrides (acting as a source of hyperpolarization) and those of the substrate. Recently, the application of highly non-intuitive pulse sequences (comprising pulses of microtesla DC fields) was predicted to hyperpolarize nuclear spins more efficiently than the canonical (static-field) SABRE-SHEATH approach. Here we show that by employing a basic “on-off” pulse sequence of rectangular microtesla pulses, it is possible to improve the hyperpolarization efficiency for SABRE-SHEATH of [ 15 N 3 ]metronidazole, an FDA-approved antibiotic (in non-enriched and non-hyperpolarized form) and potential hypoxia sensing molecule. Specifically, we demonstrate that 15N polarization of 18.5 % can be obtained in 80 s of parahydrogen bubbling parahydrogen through a solution containing 20 mM [ 15 N 3 ]metronidazole. In practice, (1.32 ± 0.14)-fold improvements in P 15N was obtained with the pulsed method described here compared to static field technique variant. These results show that pulsed SABRE-SHEATH was successfully applied to 15 N-labeled biologically relevant molecule. Moreover, we also demonstrate that although the pulsed SABRE-SHEATH sequence was designed for polarization transfer from parahydrogen derived hydrides to the metronidazole’s 15 N catalyst-binding site, all three 15 N sites of [ 15 N 3 ]metronidazole attained the hyperpolarized state. This spin-relayed polarization transfer becomes possible due to the 15 N relay network established by their spin-spin J-couplings. The feasibility of the spin-relayed polarization transfer is demonstrated here for the first time for pulsed SABRE-SHEATH (as opposed to the static-field SABRE-SHEATH reported previously) and it paves the way to broad applicability of the technique.

Hyperpolarization

Carbon‐13 Hyperpolarization of α‐Ketocarboxylates with Parahydrogen in Reversible Exchange

Abstract Signal Amplification by Reversible Exchange (SABRE) is a relatively simple and fast hyperpolarization technique that has been used to hyperpolarize the α‐ketocarboxylate pyruvate, a central metabolite and the leading hyperpolarized MRI contrast agent. In this work, we show that SABRE can readily be extended to hyperpolarize 13 C nuclei at natural abundance on many other α‐ketocarboxylates. Hyperpolarization is observed and optimized on pyruvate (P 13C =17 %) and 2‐oxobutyrate (P 13C =25 %) with alkyl chains in the R‐group, oxaloacetate (P 13C =11 %) and alpha‐ketoglutarate (P 13C =13 %) with carboxylate moieties in the R group, and phenylpyruvate (P 13C =2 %) and phenylglyoxylate (P 13C =2 %) with phenyl rings in the R‐group. New catalytically active SABRE binding motifs of the substrates to the hyperpolarization transfer catalyst – particularly for oxaloacetate – are observed. We experimentally explore the connection between temperature and exchange rates for all of these SABRE systems and develop a theoretical kinetic model, which is used to fit the hyperpolarization build‐up and decay during SABRE activity.

McBride, Stephen J. [Department of Chemistry North

Robust Rapid Cellular Metabolite Sensing Using Benchtop NMR and SABRE-Hyperpolarized [1- 13 C]Pyruvate

Hyperpolarized NMR has emerged as a powerful analytical technique to significantly enhance targeted NMR signals, improving the sensitivity for investigations of unique chemical and biological dynamics. Here, we demonstrate the use of a hyperpolarization strategy based on Signal Amplification By Reversible Exchange (SABRE) to generate highly reproducible doses of a hyperpolarized [1- 13 C]pyruvate probe for benchtop characterization of yeast metabolism. This method allows rapid, scalable, and benchtop preparation of biocompatible hyperpolarized solutions suitable for live-cell experiments. We show that this production can be dove-tailed into a modular, compact workflow to characterize real-time metabolism in cell cultures, using Saccharomyces cerevisiae (Baker’s yeast) as a model organism. With high temporal resolution, we show that this method can resolve the conversion of hyperpolarized [1- 13 C]pyruvate into oxidative decarboxylation products CO 2 and bicarbonate. This conversion exhibits sustained and detectable metabolic activity for over 300 s after introduction of the agent to the cells. We model the metabolite kinetics to show decarboxylation activity and derive estimates of the pH over time from the CO 2 and bicarbonate (carbonic acid buffer system) equilibrium to probe changes in the cellular environment during active metabolism. These results highlight the utility of benchtop SABRE-hyperpolarized [1- 13 C]pyruvate as a scalable, specific probe for metabolic phenotyping of living cells using compact, low-cost instrumentation well-suited for future high-throughput applications across microbial engineering, drug response profiling, and dynamic metabolic screening.

fungi

Coherent Control over Nuclear Hyperpolarization Using an Optically Initializable Chromophore-Radical System

Chromophore radicals (CR) are emerging as important components for molecular quantum information science (QIS), especially in the context of quantum sensing. Here, we demonstrate that the optically hyperpolarized electrons in a 1,6,7,12-tetrakis(4-tert-butylphenoxy)-perylene-3,4,9,10-bis(dicarboximide) (tpPDI) covalently linked to a partially deuterated 1,3-bis(diphenylene)-d 16 -2-phenylallyl radical (BDPA-d 16 ) can be coherently manipulated via pulsed dynamic nuclear polarization (DNP) methods to transfer polarization to nuclear spins and back. Under light illumination at 85 K, electron hyperpolarization in BDPA is enhanced 2.1- to 2.4-fold over thermal polarization and lasts for more than 100 ms. By applying nuclear orientation via electron spin-locking (NOVEL) DNP, this optically amplified electron hyperpolarization was successfully transferred to a 1 H nuclear spin within the CR system and efficiently returned to the electron spin for readout via reverse-NOVEL. The NOVEL transfer efficiency of 65% amounts to a 688-fold nuclear spin hyperpolarization of the target nuclear spin, considering the 2.1-fold electron spin hyperpolarization. This reversible coherent manipulation of hyperpolarization transfer highlights the utility of CR systems to initialize and read out nuclear spin states in a disordered matrix at moderate cryogenic temperatures. Coupled with CRs’ environmental compatibility, tunability, and precise state initialization, these results highlight the promising role of nuclear spins in CRs for QIS applications, including quantum sensing and memory.

charge transfer

Signal-to-noise ratio comparison of encoding methods for hyperpolarized noble gas MRI

Some non-Fourier encoding methods such as wavelet and direct encoding use spatially localized bases. The spatial localization feature of these methods enables optimized encoding for improved spatial and temporal resolution during dynamically adaptive MR imaging. These spatially localized bases, however, have inherently reduced image signal-to-noise ratio compared with Fourier or Hadamad encoding for proton imaging. Hyperpolarized noble gases, on the other hand, have quite different MR properties compared to proton, primarily the nonrenewability of the signal. It could be expected, therefore, that the characteristics of image SNR with respect to encoding method will also be very different from hyperpolarized noble gas MRI compared to proton MRI. In this article, hyperpolarized noble gas image SNRs of different encoding methods are compared theoretically using a matrix description of the encoding process. It is shown that image SNR for hyperpolarized noble gas imaging is maximized for any orthonormal encoding method. Methods are then proposed for designing RF pulses to achieve normalized encoding profiles using Fourier, Hadamard, wavelet, and direct encoding methods for hyperpolarized noble gases. Theoretical results are confirmed with hyperpolarized noble gas MRI experiments. Copyright 2001 Academic Press.

Non-NASA Center

Ultra-low field 13 C MRI of hyperpolarized pyruvate

Medicine is evolving beyond therapy largely predicated on anatomical information and towards incorporating patient-specific molecular biomarkers of disease for more accurate diagnosis and effective treatment. The complementary combination of hyperpolarization by spin-lock induced crossing signal amplification by reversible exchange (SLIC SABRE) and low field magnetic resonance imaging (MRI) can enable accessible metabolic imaging to advance personalized medicine. Hyperpolarized 13 C-enriched pyruvate has demonstrated promise for imaging metabolism in cancer, heart disease and neurodegenerative disorders; however, broader clinical adoption awaits validated clinical indications, and is further constrained by the cost and limited availability of current hyperpolarization technology. Parahydrogen-based polarization techniques, paired with low-cost high-performance MRI at millitesla fields, offer a means of broadening the reach of metabolic imaging. Here we show results demonstrating in situ hyperpolarization of pyruvate at 6.5 mT by SLIC SABRE, followed by immediate readout without field cycling or sample shuttling. We achieve 13 C signal enhancements several million times above thermal equilibrium at 6.5 mT, corresponding to polarization levels of approximately 3%. Leveraging this enhancement, we perform 13 C MRI and acquire NMR spectra with resolution sufficient to distinguish chemical shifts between pyruvate isotopomers. These results show a viable pathway towards accessible metabolic imaging with hyperpolarized 13 C MRI at ultra-low field.

Medical and clinical diagnostics

Scalable Hyperpolarized MRI Enabled by Ace‐SABRE of [1‐ 13 C]Pyruvate

Abstract Hyperpolarized (HP) MRI using [1– 13 C]pyruvate is emerging as a promising molecular imaging approach. Among hyperpolarization methods, Signal Amplification By Reversible Exchange (SABRE) is attractive because SABRE polarizes the substrates directly in room‐temperature solutions avoiding complex hardware. Most SABRE experiments have historically been performed in methanol, a relatively toxic and difficult‐to‐remove solvent. Here we demonstrate the use of a 80/20 acetone/water (A/W) solvent system (Ace‐SABRE) to provide hyperpolarized [1– 13 C]pyruvate with up to 17% polarization, then implement a solvent processing protocol to achieve injectable solutions retaining 74% of the initial polarization, and lastly we demonstrate HP in vivo spectroscopy and imaging using the Ace‐SABRE platform to showcase metabolic tracking in a hepatocellular carcinoma (HCC) tumor as well as HP‐MRI, both in direct comparison to dissolution dynamic nuclear polarization (d‐DNP) experiments. The Ace‐SABRE technique promises faster adoption of SABRE hyperpolarization in biological experiments, overall lowering the barriers to entry for HP‐NMR and HP‐MRI.

Chemistry

Hyperpolarized (129)Xe T (1) in oxygenated and deoxygenated blood

The viability of the new technique of hyperpolarized (129)Xe MRI (HypX-MRI) for imaging organs other than the lungs depends on whether the spin-lattice relaxation time, T(1), of (129)Xe is sufficiently long in the blood. In previous experiments by the authors, the T(1) was found to be strongly dependent upon the oxygenation of the blood, with T(1) increasing from about 3 s in deoxygenated samples to about 10 s in oxygenated samples. Contrarily, Tseng et al. (J. Magn. Reson. 1997; 126: 79-86) reported extremely long T(1) values deduced from an indirect experiment in which hyperpolarized (129)Xe was used to create a 'blood-foam'. They found that oxygenation decreased T(1). Pivotal to their experiment is the continual and rapid exchange of hyperpolarized (129)Xe between the gas phase (within blood-foam bubbles) and the dissolved phase (in the skin of the bubbles); this necessitated a complicated analysis to extract the T(1) of (129)Xe in blood. In the present study, the experimental design minimizes gas exchange after the initial bolus of hyperpolarized (129)Xe has been bubbled through the sample. This study confirms that oxygenation increases the T(1) of (129)Xe in blood, from about 4 s in freshly drawn venous blood, to about 13 s in blood oxygenated to arterial levels, and also shifts the red blood cell resonance to higher frequency. Copyright 2000 John Wiley & Sons, Ltd. Abbreviations used BOLD blood oxygen level dependent NOE nuclear overhouses effect PO(2) oxygen partial pressure RBC red blood cells RF radio frequency SNR signal-to-noise ratio.

NASA Discipline Life Support Systems

SABRE-SHEATH hyperpolarized 15 N 2 -imidazole for Zn 2+ sensing

Zinc ions are essential for numerous biological functions and activities. Accordingly, Zn 2+ sensors are crucial in biomedical research to understand the role of Zn 2+ in health and disease. Here, we demonstrated the viability of SABRE-SHEATH hyperpolarized 15 N 2 -imidazole, providing an NMR signal enhancement of 45 700 fold (p = 2.15%), as a probe for Zn 2+ sensing by monitoring the Zn-imidazole interaction using NMR and extracted a LOD of 1.3 mM. This study is one of the first demonstrations of SABRE-SHEATH hyperpolarized 15 N as a sensor of other non-hyperpolarized species, which promises chemical sensing without penetration-depth limitations.

Hyperpolarization

Machine Learning-Guided Optimization of SABRE Hyperpolarization for α-Ketoglutarate in Acetone–Water

Signal amplification by reversible exchange (SABRE) is a hyperpolarization method that polarizes target nuclei of metabolites quickly and efficiently. Recent SABRE advances, including Ace-SABRE, yield biocompatible, aqueous solutions of hyperpolarized markers for metabolic monitoring. Building on recent advancements, expanding the substrate scope of Ace-SABRE is desirable. However, SABRE polarization is sensitive to many different parameters; therefore, traditional optimization approaches are experimentally time-consuming. In this proof-of-concept application of machine learning (ML), Bayesian optimization (BO) is used for four important input parameters to model the complex SABRE dynamics while saving experimental time. The presented ML model also provides chemical insights that enable predictions of sample compositions for increased polarization levels. In this paper, we transition from an original average free polarization of p = ∼0.90% to a maximum observed free polarization of p = ∼6.6% for 1- 13 C alpha-ketoglutarate (AKG) with 13 C at natural abundance, utilizing both direct outputs as well as chemical insights revealed by the ML model.

Catalysts

Distal airways in humans: dynamic hyperpolarized 3He MR imaging--feasibility

Dynamic hyperpolarized helium 3 (3He) magnetic resonance (MR) imaging of the human airways is achieved by using a fast gradient-echo pulse sequence during inhalation. The resulting dynamic images show differential contrast enhancement of both distal airways and the lung periphery, unlike static hyperpolarized 3He MR images on which only the lung periphery is seen. With this technique, up to seventh-generation airway branching can be visualized. Copyright RSNA, 2003.

NASA Discipline Life Sciences Technologies

Physiological response of rats to delivery of helium and xenon: implications for hyperpolarized noble gas imaging

The physiological effects of various hyperpolarized helium and xenon MRI-compatible breathing protocols were investigated in 17 Sprague-Dawley rats, by continuous monitoring of blood oxygen saturation, heart rate, EKG, temperature and endotracheal pressure. The protocols included alternating breaths of pure noble gas and oxygen, continuous breaths of pure noble gas, breath-holds of pure noble gas for varying durations, and helium breath-holds preceded by two helium rinses. Alternate-breath protocols up to 128 breaths caused a decrease in oxygen saturation level of less than 5% for either helium or xenon, whereas 16 continuous-breaths caused a 31.5% +/- 2.3% decrease in oxygen saturation for helium and a 30.7% +/- 1. 3% decrease for xenon. Breath-hold protocols up to 25 s did not cause the oxygen saturation to fall below 90% for either of the noble gases. Oxygen saturation values below 90% are considered pathological. At 30 s of breath-hold, the blood oxygen saturation dropped precipitously to 82% +/- 0.6% for helium, and to 76.5% +/- 7. 4% for xenon. Breath-holds longer than 10 s preceded by pre-rinses caused oxygen saturation to drop below 90%. These findings demonstrate the need for standardized noble gas inhalation procedures that have been carefully tested, and for continuous physiological monitoring to ensure the safety of the subject. We find short breath-hold and alternate-breath protocols to be safe procedures for use in hyperpolarized noble gas MRI experiments. Copyright 2000 John Wiley & Sons, Ltd.

NASA Discipline Life Sciences Technologies

J -Resolved Molecular Fingerprinting by Parahydrogen Hyperpolarized Low-Field NMR

A J-resolved spectroscopy that depends on homonuclear scalar coupling in the strong-coupling regime and heteronuclear coupling in the weak regime expands complex peak patterns to a second axis. Hyperpolarization by Signal Amplification by Reversible Exchange (SABRE) enables the spectroscopy at a low magnetic field of 0.82 mT. Overlapping peaks of molecules such as 3-fluoropyridine and 3,5-difluoropyridine are resolved. Density matrix simulations of the 1 H and 19 F spins indicate a strong dependence on the signs and values of the J-coupling constants, including the homonuclear couplings that are not directly observable. The best matching peak positions and intensities predict coupling constants, including couplings between chemically equivalent nuclear spins, ranging in magnitude from 0.4 to 9.0 Hz for the two molecules. Simulations of other spin systems show unique patterns for molecules containing 1 H and 19 F or 13 C. The dependence of the J-resolved peak patterns on all coupling constants in a spin system presents a new modality for portable and inexpensive identification of molecules.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH

MRI of the lung gas-space at very low-field using hyperpolarized noble gases

In hyperpolarized (HP) noble-gas magnetic resonance imaging, large nuclear spin polarizations, about 100,000 times that ordinarily obtainable at thermal equilibrium, are created in 3He and 129Xe. The enhanced signal that results can be employed in high-resolution MRI studies of void spaces such as in the lungs. In HP gas MRI the signal-to-noise ratio (SNR) depends only weakly on the static magnetic field (B(0)), making very low-field (VLF) MRI possible; indeed, it is possible to contemplate portable MRI using light-weight solenoids or permanent magnets. This article reports the first in vivo VLF MR images of the lungs in humans and in rats, obtained at a field of only 15 millitesla (150 Gauss).

NASA Discipline Life Sciences Technologies