Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “hydrogen gas”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Combustion gas properties. Part 3: Hydrogen gas fuel and dry air

A series of computations has been made to produce the equilibrium temperature and gas composition for hydrogen gas fuel and dry air. The computed tables and figures provide combustion gas property data for pressures from 0.5 to 50 atmospheres and equivalence ratios from 0 to 2.0. Only sample tables and figures are provided in this report.

Wear, J. D.↗

Evaporation in equilibrium, in vacuum, and in hydrogen gas

Evaporation experiments were conducted for SiO2 in three different conditions: in equilibrium, in vacuum, and in hydrogen gas. Evaporation rate in vacuum is about two orders of magnitude smaller than that in equilibrium, which is consistent with previous works. The rate in hydrogen gas changes depending on hydrogen pressure. The rate at 10 exp -7 bar of hydrogen pressure is as small as that of free evaporation, but at 10 exp -5 bar of hydrogen pressure it is larger than that in equilibrium. In equilibrium and in vacuum, the evaporation rate is limited by decomposition of SiO2 on the crystal surface, but it is limited by a diffusion process for evaporation in hydrogen gas. Therefore, evaporation rate of minerals in the solar nebula can be shown neither by that in equilibrium nor by that in vacuum. The maximum temperature of the solar nebula at the midplane at 2-3 AU where chondrites are believed to have originated is calculated to be as low as 150 K, 1500 K, or in between them. The temperature is, in any case, not high enough for total evaporation of the interstellar materials. Therefore, evaporation of interstellar materials is one of the most important processes for the origin and fractionation of solid materials. The fundamental process of evaporation of minerals has been intensively studied for these several years. Those experiments were carried out either in equilibrium or in vacuum; however, evaporation in the solar nebula is in hydrogen (and much smaller amount of helium) gas. In order to investigate evaporation rate and compositional (including isotopic) fractionation during evaporation, vaporization experiments for various minerals in various conditions are conducted. At first, SiO2 was adopted for a starting material, because thermochemical data and its nature of congruent vaporization are well known. Experiments were carried out in a vacuum furnace system.

Nagahara, Hiroko↗

Device removes hydrogen gas from enclosed spaces

Hydrogen-oxidant galvanic cell removes small amounts of hydrogen gas continually released from equipment, such as vented silver-zinc batteries, in enclosed compartments where air venting is not feasible. These cells are used in satellite compartments.

Carson, W. N.↗

Automated Hydrogen Gas Leak Detection System

The Gencorp Aerojet Automated Hydrogen Gas Leak Detection System was developed through the cooperation of industry, academia, and the Government. Although the original purpose of the system was to detect leaks in the main engine of the space shuttle while on the launch pad, it also has significant commercial potential in applications for which there are no existing commercial systems. With high sensitivity, the system can detect hydrogen leaks at low concentrations in inert environments. The sensors are integrated with hardware and software to form a complete system. Several of these systems have already been purchased for use on the Ford Motor Company assembly line for natural gas vehicles. This system to detect trace hydrogen gas leaks from pressurized systems consists of a microprocessor-based control unit that operates a network of sensors. The sensors can be deployed around pipes, connectors, flanges, and tanks of pressurized systems where leaks may occur. The control unit monitors the sensors and provides the operator with a visual representation of the magnitude and locations of the leak as a function of time. The system can be customized to fit the user's needs; for example, it can monitor and display the condition of the flanges and fittings associated with the tank of a natural gas vehicle.

Source record↗

A study of the processes in the RF hydrogen gas dissociator

The role of the RF gas dissociator in the hydrogen maser is examined. Based on collisional and plasma transport processes, the performance of the source is investigated. It is found that while the complexity of the collisional processes in the RF dissociator prohibits an easily obtained quantitative expression for the performance of the source, it is nevertheless possible to make general inferences concerning the qualitative performance based on collisional effects. An analytical expression for the efficiency of the source in atom production is obtained based on plasma transport processes. On the basis of this study some recommendations are made for the development of more efficient RF hydrogen gas dissociators for use in masers.

Maleki, L.↗

Development of a hydrogen gas sensor using microfabrication technology

Microfabrication and micromachining technologies are used to produce a hydrogen gas sensor based on a palladium-silver film. The sensor uses a heater that is fabricated by diffusing p-type borones into the substrate, forming a resistance heater. A diode for temperature measurement is produced using p-type boron and n-type phosphor diffused into the substrate. A thickness of the palladium-silver film is approximately 300 arcsec. The hydrogen gas sensor employs the proven palladium-silver diode structure and is surrounded by a phosphor doped resistance heater which can be heated up to a temperature of 250 C. Experimental results show that the sensor is capable of operating over a wide range of hydrogen concentration levels between 0-95 percent without any hysteresis effects.

Liu, Chung-Chiun↗

Purification train produces ultrapure hydrogen gas

Three-stage purification train produces ultrapure hydrogen gas at 1000 psi from K-bottles of high-purity hydrogen. The continuous process incorporates deoxidation and dehydration units and a molecular sieve.

Walter, R. J.↗

Heat and mass transfer rates during flow of dissociated hydrogen gas over graphite surface

To improve upon the performance of chemical rockets, the nuclear reactor has been applied to a rocket propulsion system using hydrogen gas as working fluid and a graphite-composite forming a part of the structure. Under the boundary layer approximation, theoretical predictions of skin friction coefficient, surface heat transfer rate and surface regression rate have been made for laminar/turbulent dissociated hydrogen gas flowing over a flat graphite surface. The external stream is assumed to be frozen. The analysis is restricted to Mach numbers low enough to deal with the situation of only surface-reaction between hydrogen and graphite. Empirical correlations of displacement thickness, local skin friction coefficient, local Nusselt number and local non-dimensional heat transfer rate have been obtained. The magnitude of the surface regression rate is found low enough to ensure the use of graphite as a linear or a component of the system over an extended period without loss of performance.

Nema, V. K.↗

The development of a magnetically enhanced hydrogen gas dissociation

Application of a dc magnetic field on an RF hydrogen gas dissociator led to the development of a more efficient source of atoms for hydrogen masers. The influence of the applied magnetic field on the plasma and some details of the resulting enhancement of the dissociation efficiency are discussed. Ways that this improved efficiency can result in the enhancement of the operation and field life of hydrogen masers, as well as aid the development of spaceborne masers, are considered.

Maleki, L.↗

Magnetically Enhanced Hydrogen Gas Dissociator: a Progress Report

The application of a sensitive hydrogen gas detector led to the observation of a significant increase in the efficiency of atom production of a magnetically enhanced dissociator. An increase of about 7000% in the production of atoms in the hyperfine state desired for maser operation is observed at certain values of the applied magnetic field. A preliminary test of the dissociator in the maser led to an observed increase of 6.18 dB in the maser power.

Lee, G.↗

Laser Raman sensor for measurement of trace-hydrogen gas

A new optical hydrogen sensor based on spontaneous Raman scattering of laser light has been designed and constructed for rugged field use. It provides good sensitivity, rapid response, and the inherent Raman characteristics of linearity and background gas independence of the signal. Efficient light collection and discrimination by using fast optics and a bandpass interference filter compensate for the inefficiency of the Raman-scattering process. A multipass optical cavity with a Herriott-type configuration provides intense illumination from an air-cooled CW gas laser. The observed performance is in good agreement with the theoretical signal and noise level predictions.

Adler-Golden, Steven M.↗