Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “hybrid two-phase cooling”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

Thin hybrid capillary two-phase cooling system

A novel hybrid two-phase cooling system was developed that integrated a mechanically pumped two-phase loop with a capillary-driven two-phase cooling device. The latter cooling mechanism was based on evaporation/boiling from wick structures made by sintering copper particles on the interior surfaces of a copper cold plate. The cold plate provided cooling to two surfaces and each of them included four heaters in series. The novelty of the developed technology was preventing flooding of the evaporator wicks by isolating the evaporation surface from the pumped liquid flow that fed them. This arrangement allowed for a high liquid feed flow rate much greater than would be allowed by a capillary pumped system while maintaining a low thermal resistance at the evaporation surface. Using this approach, the cooling system removed over 850 W with a low pumping power below 1.0 W while using R245fa as the working fluid. The equivalent heat fluxes exceeded 970 W/cm 2 over areas less than 0.12 cm 2 . The measured thermal resistance was as low as 0.09 K-cm 2 /W. The presented thermal management solution enables an increase in the power of high heat flux electronic devices beyond the state-of-the-art.

42 ENGINEERING↗

Holistic energy analysis method for thermal management architectures of data centers

Modern high-performance computing (HPC) data centers (DCs), particularly those supporting energy-intensive artificial intelligence (AI) workloads, face escalating thermal management challenges that degrade performance through thermal throttling and drive up cooling power consumption and operational costs. To address this challenge, many have developed a wide variety of thermal management solutions (single-phase, two-phase, direct, indirect, hybrid, and more) which attempt to cool HPC DCs effectively while attempting to minimize overall system power consumption. However, the analysis of these solutions and methods to effectively compare one with another is lacking. Overall power usage effectiveness (PUE) and total-power usage effectiveness (TUE) provide a metric to quantify power consumption but fail to identify components in the system which require further optimization. To address this, we propose a holistic analytical framework – the waterfall diagram (WFD) – which leverages a waterfall chart methodology, offering a comprehensive visualization of both the thermal management system loop and heat flow pathways from individual server components to the outdoor ambient. Use of the WFD enables graphical estimations of power efficiency and cooling performance across each component of a DC cooling system and complements Sankey-style energy flow visualizations by additionally resolving stage-wise temperature changes and incremental TUE contributions. The framework is used in conjunction with simulation-based approaches, to conduct a detailed pressure drop and flow distribution analysis aimed at identifying the optimal coolant distribution architecture for a single-phase direct-to-chip water-cooled DC, which serves as the baseline for subsequent WFD analysis. Among the evaluated architectures, the 3 U modular coolant distribution architecture is found to demonstrate the best performance, considering minimal pressure drop and uniform flow distribution. In addition, TUE is calculated for each cooling loop component based on its associated pressure drop and corresponding pumping power, which are integrated into the WFD. This correlation between TUE and local temperature offers immediate insight into the power efficiency and thermal performance contributions of individual components, facilitating further development and optimization. Examples of WFD applications are presented under varying thermal loads and ambient conditions, demonstrating reasonable cooling strategies. Notably, the 3 U modular architecture maintains a consistent chip case temperature of 85°C, achieving a TUE of 1.016 at ambient temperature of 47°C, and a TUE of 1.026 at ambient temperature of 52°C. The WFD methodology provides an efficient, holistic, and streamlined framework for DC thermal management architecture assessment and enables design optimization which is important for addressing the thermal-fluidic energy challenges of current and next-generation DCs.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Development of a Hybrid Single/Two-Phase Capillary-Based Micro-Cooler using Copper Inverse Opals Wick with Silicon 3D Manifold for High-Heat-Flux Cooling Application

Previously, we reported two-phase capillary-based cooling using narrow (200 to 1000 ..mu..m) heater bridge copper inverse opal (CIO) wicks with heat flux level of 1400 Wcm -2 and superheat ~ 10 degrees C. Here, we demonstrate the area scaling of the proposed technology to a large-area micro-cooler for high-heat-flux cooling of microprocessors and power electronics. We developed a hybrid single/two-phase micro-cooler that relies on capillary-wicking in a 25-..mu..m-thick CIO with an open silicon microchannel 3D-manifold for liquid delivery and vapor extraction, achieving a high heat flux ~ 400 Wcm -2 over a heated area of 10 x 10 mm 2 . For a range of inlet water flowrates from 5 to 60 g(min) -1 , we achieved total thermal resistances and vapor qualities of 0.68 cm 2 degrees CW -1 to 0.2 cm 2 degrees CW -1 and 0.55 to 0.12, respectively. The flowrates are 10x smaller than those of conventional single- or two-phase microchannel cooling technology. The corresponding two-phase thermal resistances ranges from 0.05 to 0.02 cm 2 degrees CW -1 with temperature superheat of 8 to 6 degrees C, respectively. While the overall performance of the large-area (10 x 10 mm 2 ) capillary-based micro-cooler degraded compared to the previous demonstration of the technology for a heated area of 5 x 5 mm 2 , however, preliminary CFD modeling indicates that an improved manifold design will be able to achieve comparable performance.

capillary flow↗

Development of a Hybrid Single/Two-Phase Capillary-Based Micro-Cooler Using Copper Inverse Opals Wick with Silicon 3D Manifold for High-Heat-Flux Cooling Application: Preprint

Previously, two-phase capillary-based cooling from narrow (200-1,000 micrometer) heater-bridge copper inverse opal (CIO) wicks with heat flux levels exceeding 1,400 watts per square cm with a low superheat of approximately 10 degrees C was demonstrated. Here, we demonstrate the area scaling of the proposed technology to large-area micro-cooler for the high-heat-flux cooling of microprocessors and power electronics. We developed a hybrid single/two-phase micro-cooler that relies on capillary wicking in 25-micrometer-thick CIOs with an open channel silicon 3D-manifold for liquid delivery and vapor extraction, to achieve a high heat flux of approximately 400 watts per square cm over a heated area of 1 square cm. For the range of inlet water (21 degrees C water temperature) flowrates from 5 to 60 mL per min, we achieved total thermal resistances and vapor qualities of 0.68-0.2 square cm Kelvin per watt and 0.55-0.12, respectively. The high heat flux levels are achieved with flowrates that are 10 times smaller than conventional single- or two-phase microchannel cooling technology. The corresponding two-phase thermal resistances are in the range of 0.05 to 0.02 square cm Kelvin per watt with temperature superheat of 8 to 6 degrees C. While the overall performance of the large-area (10 by 10 square millimeter) capillary-based micro-cooler degraded compared to previous demonstration of the technology for a heated area of 5 by 5 square millimeter, preliminary computational fluid dynamics (CFD) modeling indicates that an improved manifold design will be able to achieve comparable performance.

capillary flow↗

Mass Flow Rate and Isolation Characteristics of Injectors for Use with Self-Pressurizing Oxidizers in Hybrid Rockets

Self-pressurizing rocket propellants are currently gaining popularity in the propulsion community, particularly in hybrid rocket applications. Due to their high vapor pressure, these propellants can be driven out of a storage tank without the need for complicated pressurization systems or turbopumps, greatly minimizing the overall system complexity and mass. Nitrous oxide (N2O) is the most commonly used self pressurizing oxidizer in hybrid rockets because it has a vapor pressure of approximately 730 pounds per square inch (5.03 megapascals) at room temperature and is highly storable. However, it can be difficult to model the feed system with these propellants due to the presence of two-phase flow, especially in the injector. An experimental test apparatus was developed in order to study the performance of nitrous oxide injectors over a wide range of operating conditions. Mass flow rate characterization has been performed to determine the effects of injector geometry and propellant sub-cooling (pressurization). It has been shown that rounded and chamfered inlets provide nearly identical mass flow rate improvement in comparison to square edged orifices. A particular emphasis has been placed on identifying the critical flow regime, where the flow rate is independent of backpressure (similar to choking). For a simple orifice style injector, it has been demonstrated that critical flow occurs when the downstream pressure falls sufficiently below the vapor pressure, ensuring bulk vapor formation within the injector element. It has been proposed to leverage the insensitivity of critical mass flow rate to downstream pressure as a means of preventing the occurrence of feed system coupled combustion instabilities in hybrid rockets utilizing nitrous oxide. Additionally, observations indicate that the existence of two-phase flow can attenuate pressure fluctuations traveling upstream through the injector, providing a degree of isolation between the feed line and downstream pressure disturbances. In consideration of safety, carbon dioxide (CO2) has been used as an analog to nitrous oxide in many of these studies. It has been observed experimentally that carbon dioxide serves as a good analog to nitrous oxide in both the single-phase and two-phase flow regimes.

Oxidizer↗

Capillary-Enhanced Two-Phase Micro-Cooler Using Copper-Inverse-Opal Wick with Silicon Microchannel Manifold for High-Heat-Flux Cooling Application

In this work, we demonstrate a two-phase capillary-fed boiling micro-cooler that consists of a ~ 25-..mu..m-thick copper inverse opal (CIO) porous wicking structure for high-heat-flux boiling and a silicon 3D-manifold for distributed liquid delivery and vapor extraction across a 0.5 cm x 0.5 cm heated area. At low inlet water mass flow rates of 1.5 to 1.9 g(min)-1, the micro-cooler displays nearly two-phase boiling with exit vapor quality ~ 1 and a high critical heat flux (CHF) of 253 to 320 W cm-2 with low superheat of ~ 10 degrees C resulting in a thermal resistance of boiling ~ 0.025 cm2 degrees C W-1 or heat transfer coefficient of 0.4 MW m-2 degrees C-1. For higher flow rates of 5, 10, and 15 g(min)-1, the micro-cooler exhibits a hybrid single-phase and two-phase cooling regime where the contribution of the sensible heat (single-phase) cooling is linearly added to that of the two-phase cooling. For the highest flow rate of 15 g(min)-1, the CHF is increased to ~ 500 W cm-2 resulting in an overall thermal resistance of ~ 0.18 cm2 degrees C W-1. However, the two-phase heat transfer effectiveness, which estimates the utilization level of the inlet mass flow rate for two-phase boiling, is reduced to ~ 0.11. To achieve the best cooling system performances, the micro-cooler must operate entirely within the two-phase boiling regime (exit vapor quality or two-phase heat transfer effectiveness ~ 1). Ideally, the "coolant" should be delivered near its saturation temperature (~ 100 degrees C for water), which provides significant advantages for the energy-efficient operation of data centers and power electronics. We present detailed analysis with Infrared and high speed camera images at various inlet flow rates and heat fluxes to understand complex heat transfer in the micro-cooler. Furthermore, a conjugate thermofluidic simulation model, which incorporates the physics of capillary-fed boiling in a porous copper layer, agrees well with the experimental data.

capillary-enhanced boiling↗

Integration and validation of some modules for modelling of high-speed chemically reactive flows in two-phase gas-droplet mixtures

Three modules are integrated into the built-in OpenFOAM rhoCentralFoam solver towards accurate and efficient modelling of high-speed chemically reactive flows in two-phase gas-droplet mixtures within the OpenFOAM 10.0 framework. The first module is the mixture-averaged diffusion model. The second module is the built-in OpenFOAM Lagrangian solver coupled with optimised droplet drag coefficient and convective heat transfer coefficient sub-models. The last module is a sparse stiff chemistry solver based on dynamic adaptive hybrid integration (AHI-S). The optimised droplet sub-models are first verified in correct implementation for subsequent simulations in this work. Further, they show good accuracy against experimental and analytical data in the modelling of ammonia droplet acceleration and cooling in the flowing and/or low-temperature air. The accuracy and efficiency gains related to the mixture-averaged diffusion model and the AHI-S chemistry solver are examined by simulating 1-D detonation propagation in ammonia droplet-free/laden ammoniaoxygen mixtures. Numerical results of detonation propagation speed, gaseous temperature, density, and species distributions around the induction zone show good agreement with experimental data and analytical solutions. Compared to the built-in OpenFOAM diffusion model, the mixture-averaged diffusion model provides different numerical predictions of pulsating instabilities in detonation propagation. It shows better accuracy in depicting the detonation structure within the droplet-free section attributed to improved multi-component diffusion modelling. Compared to the built-in OpenFOAM solver EulerImplicit (backward Euler), the AHI-S chemistry solver reduces the computational cost by around 50%. It achieves satisfactory accuracy in calculating detonation propagation speed within the droplet-free section with the optimal efficiency when the safety factor, β, equals 0.5.

42 ENGINEERING↗