Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “homeowners”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

An inexpensive economical solar heating system for homes

A low-cost solar home heating system to supplement existing warm-air heating systems is described. The report is written in three parts: (1) a brief background on solar heating, (2) experience with a demonstration system, and (3) information for the homeowner who wishes to construct such a system. Instructions are given for a solar heating installation in which the homeowner supplies all labor necessary to install off-the-shelf components estimated to cost $2,000. These components, which include solar collector, heat exchanger, water pump, storage tank, piping, and controls to make the system completely automatic, are available at local lumber yards, hardware stores, and plumbing supply stores, and are relatively simple to install. Manufacturers and prices of each component used and a rough cost analysis based on these prices are included. This report also gives performance data obtained from a demonstration system which was built and tested at the Langley Research Center.

Allred, J. W.↗

Tech House

The members of the Swain family- Dr. Charles "Bill" Swain, wife Elaine, daughter Carol, 17, son "Chuck", 12, and dog Susie have an interesting assignment. They are active participants in an important NASA research program involving the application of space-age technology to home construction. b' Transplanted Floridians, the Swains now reside in NASA's Tech House, lo~atedat Langley Research Center, Hampton, Virginia. Their job is to use and help evaluate the variety of advanced technology systems in Tech House. A contemporary three-bedroom home, Tech House incorporates NASA technology, the latest commercial building techniques and other innovations, all designed to reduce energy and water consumption and to provide new levels of comfort, convenience, security and fire safety. Tech House equipment performed well in initial tests, but a house is not a home until it has people. That's where the Swains come in. NASA wants to see how the various systems work under actual living conditions, to confirm the effectiveness of the innovations or to determine necessary modifications for improvement. The Swains are occupying the house for a year, during which NASA engineers are computer monitoring the equipment and assembling a record of day-to-day performance. . Tech House is a laboratory rather than a mass production prototype, but its many benefits may influence home design and construction. In a period of sharply rising utility costs, widespread adoption of Tech House features could provide large-scale savings to homeowners and potentially enormous national benefit in resources conservation. Most innovations are aerospace spinoffs: Some of the equipment is now commercially available; other systems are expected to be in production within a few years. Around 1980, a Tech House-type of home could be built for $45-50,000 (1 976 dollars). It is estimated that the homeowner would save well over $20,000 (again 1976 dollars) in utility costs over the average mortgage span of 20 years.

Source record↗

Solar Schematic

The home shown at right is specially designed to accommodate solar heating units; it has roof planes in four directions, allowing placement of solar collectors for best exposure to the sun. Plans (bottom) and complete working blueprints for the solar-heated house are being marketed by Home Building Plan Service, Portland, Oregon. The company also offers an inexpensive schematic (center) showing how a homeowner only moderately skilled in the use of tools can build his own solar energy system, applicable to new or existing structures. The schematic is based upon the design of a low-cost solar home heating system built and tested by NASA's Langley Research Center; used to supplement a warm-air heating system, it can save the homeowner about 40 percent of his annual heating bill for a modest investment in materials and components. Home Building Plan Service saved considerable research time by obtaining a NASA technical report which details the Langley work. The resulting schematic includes construction plans and simplified explanations of solar heat collection, collectors and other components, passive heat factors, domestic hot water supply and how to work with local heating engineers.

Source record↗

Aerial thermal scanner data for monitoring rooftop temperatures

Four Nebraska communities and one South Dakota community were surveyed. Thermal scanner data were converted to a film format and the resultant imagery was successfully employed to monitor rooftop temperatures. The program places emphasis on heat losses resulting from inadequate home insulation, offers CENGAS customers the opportunity to observe a thermogram of their rooftop, and assists homeowners in evaluating insulation needs.

Bjorkland, J.↗

A report on the use of thermal scanner data in an operational program for monitoring apparent rooftop temperatures

CENGAS, a division of Central Telephone and Utilities Corporation in cooperation with the Remote Sensing Institute, South Dakota State University, is using airborne thermal scanner data to monitor relative rooftop temperatures. Four Nebraska communities and one South Dakota community were surveyed by the Remote Sensing Institute for CENGAS. Thermal scanner data were converted to a film format and the resultant imagery has been successfully employed by CENGAS. The program places emphasis on heat losses resulting from inadequate home insulation, offers CENGAS customers the opportunity to observe a thermogram of their rooftop, and assists homeowners in evaluating insulation needs.

Bjorklund, J.↗

Window-mounted auxiliary solar heater

System uses hot-air collectors, no thermal storage, and fan with thermostat switches. At cost of heating efficiency, unit could be manufactured and sold at price allowing immediate entry to market as auxiliary heating system. Its simplicity allows homeowner installation, and maintenance is minimal.

Anthony, K. G.↗

Retrofit energy conservation in residential buildings in southern California

The common energy conservation techniques (ECTs) that can be retrofit-installed into residential buildings are surveyed. The quantity of saved energy for heating and cooling attributable to each ECT is evaluated for three common modes of heating: natural gas heating at 60/therm; heating via heat pump at $1.20/therm; and electric resistance heating at $2.40/therm. In every case, a life cycle cost comparison is made between the long term revenue due to energy conservation and a safe and conventional alternative investment that might be available to the prudent homeowner. The comparison between investment in an ECT and the alternative investment is brought into perspective using the life cycle payback period and an economic Figure of Merit (FOM). The FOM allows for relative ranking between candidate ECTs. Because the entire spectrum of winter heating climates in California is surveyed, the decision maker can determine whether or not a considered ECT is recommended in a given climate, and under what conditions an ECT investment becomes attractive.

Turner, R. H.↗

Tool Carrier

Tool organizer accommodates a selection of hand tools on a waist or thigh belt or alternately on wall, work bench, or car trunk mountings. Tool caddy is widely used by industrial maintenance personnel, TV technicians, mechanics, artists, draftsmen, hobbyists and homeowners. Its innovative feature is rows of flexible vinyl "fingers" like the bristles of a hairbrush which mesh together to hold the tool securely in place yet allow easy insertion or withdrawal. Product is no longer commercially available.

Source record↗

The Watt Count System

The Watt Count System combines aerospace and computer technology, an engineering systems design approach and the environmental control expertise of a group of engineers who worked on Apollo. First step of the system is a computerized energy consumption analysis based on plans for a new home. Company calculates heating and cooling loads and customizes the most energy efficient system for the particular structure analyzed. A quality control engineer assures that insulation and ducting are installed to specifications. Analysis and design techniques are so accurate that company is able to give homeowner a two-year guarantee that the home's energy consumption will not exceed the kilowatt hour level determined by the computer in step one. In an annual energy performance comparison, a Watt Count home used 45 percent less energy than a conventionally equipped home.

Source record↗

Creating Gridded Fire Probability Maps using NASA Data

Fire is a nationally and globally significant process that strongly affects human–dominated and wild landscapes. Even though fire can be devastating, wildland fire is a natural and integral force on our landscapes, providing value by decreasing fuels at the Wildland Urban Interface (WUI) to promote safe communities. However, uncontained wildfires can devastate communities, threaten our health, and result in substantial economic losses. There has been greater than a $50B increase in wildfire insurance claims from 2017-2021, which has been exacerbated by climate change. Our partners at Kettle reinsurance are focused on building a smarter reinsurance model for protecting today’s globalized world from the catastrophic effects of climate change. Our objective is to develop the world's first grid-based wildfire probability product using multiple sources of satellite data to determine whether a ‘conflagration' (fire larger than 999+ acres) has ‘breached’ a grid cell. This will substantially decrease the time it takes for homeowners to receive payouts, from over a year to a couple months. Working with our partners at Kettle reinsurance, we use multiple satellites and ancillary data to weigh the likelihood of fire, based on a number of sources that verify a fire burning in a grid cell and the level of confidence in the data source. For example, Sentinel-2 vegetation-change indices have a higher level of confidence than VIIRS (Visible Infrared Imaging Radiometer Suite) active-fire detection data; and VIIRS active-fire detection data have a higher-level of confidence than MODIS (Moderate Resolution Imaging Spectroradiometer) active-fire detection data. The first iteration has been developed for responding to wildfires in California, with the possibility to expand nationwide and globally.

Emily Gargulinski↗

Creating IR-verified Gridded Fire Burn Maps using Public NASA and Satellite Data

Even though fire can be devastating, wildland fire is a natural and integral force on our landscapes, providing value by decreasing fuels at the Wildland Urban Interface (WUI) to promote safe communities. However, uncontained wildfires can devastate communities, threaten our health, and result in substantial economic losses. There has been greater than a $50B increase in wildfire insurance claims from 2017-2021, which has been exacerbated by climate change. Our partners at Kettle reinsurance are focused on building a smarter reinsurance model for protecting today’s globalized world from the catastrophic effects of climate change. Our objective is to develop a high-confidence grid-based wildfire burn product using multiple sources of satellite data to determine whether a ‘conflagration' (fire larger than 999+ acres) has ‘breached’ a grid cell. This product will substantially decrease the time it takes for homeowners to receive payouts, from over a year to a couple months. Working with our partners at Kettle reinsurance, we use VIIRS (Visible Infrared Imaging Radiometer Suite) 375 m fire detections and Sentinel-2 10 m satellite imagery to create a 20-m gridded fire burn product. Our process is based on the level of confidence in the data source and takes into account vegetation change throughout the life of the fire. For example, Sentinel-2 vegetation-change indices have a higher level of confidence when congruent with VIIRS active-fire detection data, rather than VIIRS detections alone. We have also verified our fire burn product against MODIS/ASTER Airborne Simulator (MASTER) Infrared (IR) data from the Fire Influence on Regional to Global Environments Experiment - Air Quality (FIREX-AQ) 2019 campaign, with 88% overall agreement. The first iteration has been developed for responding to wildfires in California, with the possibility to expand nationwide and globally.

Emily Gargulinski↗