Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “hollow”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Structural analysis of hollow blades: Torsional stress analysis of hollow fan blades for aircraft jet engines

A torsional stress analysis of hollow fans blades by the finite element method is presented. The fans are considered to be double circular arc blades, hollowed 30 percent, and twisted by a component of the centrifugal force by the rated revolution. The effects of blade hollowing on strength and rigidity are discussed. The effects of reinforcing webs, placed in the hollowed section in varying numbers and locations, on torsional rigidity and the convergence of stresses, are reported. A forecast of the 30 percent hollowing against torsional loadings is discussed.

Ogawa, A.↗

An Impact Crater Origin for the InSight Landing Site at Homestead Hollow, Mars: Implications for Near Surface Stratigraphy, Surface Processes, and Erosion Rates

The InSight mission to Mars landed within Homestead hollow on an Early Amazonian lavaplain. The hollow is a 27‐m‐diameter, 0.3‐m‐deep quasi‐circular depression that shares morphologic and sedimentologic characteristics to degraded impact craters. Unlike the intercrater plains outside of the hollow, the interior lacks cobbles and is dominated by loose sand, granules, and pebbles. Fresher craters near the landing site exhibit meter‐scale bedforms in their ejecta and on their floors due to sediment trapping.The sedimentology of the interior fill of Homestead hollow suggests similar trapping. The hollow falls along amorphologic continuum that requires low rates of rim degradation and fill. Crater degradation rates (rim erosion plus filling) in the landing site decline nonlinearly through time from 10−2to 10−4m/Myr as craters evolve to a hollow‐like form. Rim erosion rates are lower initially, at 10−3m/Myr, but converge with degradation rates to 10−4m/Myr. This implies that while filling plays an important role soon after crater formation, it is limited in later stages. Crater statistics indicate that the bulk of the fill occurred in the first~50 Myr for Homestead hollow. The estimated maximum age of the hollow is ~400 to 700 Myr. This requires near‐zero fill aggradation and long‐term soil stability for the bulk of the crater's history. Fill stability manifests in Homestead hollow as a ~5‐to 10‐cm‐thick duricrust, formed by exchanges of atmospheric water vapor with soil. The estimated degradation in the hollow requires ~2 to 3 m of sedimentary fill beneath the lander.

Maria Elaine Banks↗

Energy efficient engine shroudless, hollow fan blade technology report

The Shroudless, Hollow Fan Blade Technology program was structured to support the design, fabrication, and subsequent evaluation of advanced hollow and shroudless blades for the Energy Efficient Engine fan component. Rockwell International was initially selected to produce hollow airfoil specimens employing the superplastic forming/diffusion bonding (SPF/DB) fabrication technique. Rockwell demonstrated that a titanium hollow structure could be fabricated utilizing SPF/DB manufacturing methods. However, some problems such as sharp internal cavity radii and unsatisfactory secondary bonding of the edge and root details prevented production of the required quantity of fatigue test specimens. Subsequently, TRW was selected to (1) produce hollow airfoil test specimens utilizing a laminate-core/hot isostatic press/diffusion bond approach, and (2) manufacture full-size hollow prototype fan blades utilizing the technology that evolved from the specimen fabrication effort. TRW established elements of blade design and defined laminate-core/hot isostatic press/diffusion bonding fabrication techniques to produce test specimens. This fabrication technology was utilized to produce full size hollow fan blades in which the HIP'ed parts were cambered/twisted/isothermally forged, finish machined, and delivered to Pratt & Whitney Aircraft and NASA for further evaluation.

Michael, C. J.↗

Multiple Hollow Cathode Wear Testing

A hollow cathode-based plasma contactor has been baselined for use on the Space Station to reduce station charging. The plasma contactor provides a low impedance connection to space plasma via a plasma produced by an arc discharge. The hollow cathode of the plasma contactor is a refractory metal tube, through which xenon gas flows, which has a disk-shaped plate with a centered orifice at the downstream end of the tube. Within the cathode, arc attachment occurs primarily on a Type S low work function insert that is next to the orifice plate. This low work function insert is used to reduce cathode operating temperatures and energy requirements and, therefore, achieve increased efficiency and longevity. The operating characteristics and lifetime capabilities of this hollow cathode, however, are greatly reduced by oxygen bearing contaminants in the xenon gas. Furthermore, an optimized activation process, where the cathode is heated prior to ignition by an external heater to drive contaminants such as oxygen and moisture from the insert absorbed during exposure to ambient air, is necessary both for cathode longevity and a simplified power processor. In order to achieve the two year (approximately 17,500 hours) continuous operating lifetime requirement for the plasma contactor, a test program was initiated at NASA Lewis Research Center to demonstrate the extended lifetime capabilities of the hollow cathode. To date, xenon hollow cathodes have demonstrated extended lifetimes with one test having operated in excess of 8000 hours in an ongoing test utilizing contamination control protocols developed by Sarver-Verhey. The objectives of this study were to verify the transportability of the contamination control protocols developed by Sarver-Verhey and to evaluate cathode contamination control procedures, activation processes, and cathode-to-cathode dispersions in operating characteristics with time. These were accomplished by conducting a 2000 hour wear test of four hollow cathodes with different xenon gas purities and activation processes. The following will be presented: a description of the facility and test hardware, testing procedures and operating conditions, a discussion of test results, and conclusions.

Soulas, George C.↗

Continuing life test of a xenon hollow cathode for a space plasma contactor

Implementation of a hollow cathode plasma contactor for charge control on the Space Station has required validation of long-life hollow cathodes. A test series of hollow cathodes and hollow cathode plasma contactors was initiated as part of the plasma contactor development program. An on-going wear-test of a hollow cathode has demonstrated cathode operation in excess of 10,000 hours with small changes in operating parameters. The discharge has experienced 10 shutdowns during the test, all of which were due to test facility failures or expellant replenishment. In all cases, the cathode was re-ignited at approximately 42 volts and resumed typical operation. This test represents the longest demonstrated stable operation of a high current (greater than 1 A) xenon hollow cathode reported to date.

Sarver-Verhey, Timothy R.↗

Extended test of a xenon hollow cathode for a space plasma contactor

Implementation of a hollow cathode plasma contactor for charge control on the Space Station has required validation of long-life hollow cathodes. A test series of hollow cathodes and hollow cathode plasma contactors was initiated as part of the plasma contactor development program. An on-going wear-test of a hollow cathode has demonstrated cathode operation in excess of 4700 hours with small changes in operating parameters. The discharge experienced 4 shutdowns during the test, all of which were due to test facility failures or expellant replenishment. In all cases, the cathode was reignited at approximately 42 volts and resumed typical operation. This test represents the longest demonstrated stable operation of a high current (greater than 1A) xenon hollow cathode reported to date.

Sarver-Verhey, Timothy R.↗

28,000 Hour Xenon Hollow Cathode LifeTest Results

The International Space Station Plasma Contactor System requires a hollow cathode assembly (HCA) with a lifetime of at least 18,000 hours. Critical components of the HCA include the hollow cathode and electron emitter. A series of hollow cathode wear tests was performed which included a life test operated at the maximum current of the HCA. This test sought to verify the hollow cathode design and contamination control protocols. The life test accumulated 27,800 hours of operation before failing to ignite. The hollow cathode exhibited relatively small changes in operating parameters over the course of the test. This life test is the longest duration test of a high current xenon hollow cathode reported to date.

Sarver-Verhey, Timothy R.↗

Hollow Retroreflectors Offer Solid Benefits

A technician who lead a successful team of scientists, engineers, and other technicians in the design, fabrication, and characterization of cryogenic retroreflectors for the NASA Cassini/Composite Infrared Spectrometer (CIRS) mission to Saturn, developed a hollow retroreflector technology while working at NASA Goddard Space Flight Center. With 16 years of NASA experience, the technician teamed up with another NASA colleague and formed PROSystems, Inc., of Sharpsburg, Maryland, to provide the optics community with an alternative source for precision hollow retroreflectors. The company's hollow retroreflectors are front surface glass substrates assembled to provide many advantages over existing hollow retroreflectors and solid glass retroreflectors. Previous to this new technology, some companies chose not to use hollow retroreflectors due to large seam widths and loss of signal. The "tongue and groove" facet design of PROSystems's retroreflector allows for an extremely small seam width of .001 inches. Feedback from users is very positive regarding this characteristic. Most of PROSystems's primary customers mount the hollow retroreflectors in chrome steel balls for laser tracker targets in applications such as automobile manufacturing and spacecraft assembly.

Source record↗

Characterization of Propellant Flow and Bias Required to Initiate an Arc Discharge in a Heaterless Hollow Cathode

Heaterless hollow cathodes provide an opportunity to reduce complexity and improve reliability in electric propulsion systems. While removal of the heater has little effect on steady-state operation of a hollow cathode, it has a considerable effect on the ignition process. To successfully integrate a heaterless hollow cathode into a spaceflight electric propulsion system, it will be necessary to establish definitive requirements for the propellant feed and electrical subsystems so that ignition of a plasma discharge can be achieved reliably. The aim of this research was to form a better understanding of these requirements by performing an investigation of the propellant flow and voltage conditions required for the ignition of a plasma arc discharge. This aim was achieved by performing discharge initiation experiments using both a specially designed experimental apparatus and a functional heaterless hollow cathode assembly. It was demonstrated that there is a distinct difference in the voltage required to initiate a plasma discharge between two common electric propulsion propellants, xenon and krypton, which suggests that the developmental testing of heaterless hollow cathodes needs to be performed with the appropriate propellant gas species. Heaterless hollow cathode ignition experiments showed that the keeper orifice diameter has a strong effect on the voltage required to ignite a plasma discharge at a given propellant mass flow rate, while the effect of keeper-cathode separation distance was only strong at flow rates below 25 sccm (Xe).

Ham, Ryan K.↗

Characterization of a Fixed-Volume Release System for Initiating an Arc Discharge in a Heaterless Hollow Cathode

Heaterless hollow cathodes may provide improved reliability, simplicity, and portability when compared with traditional heater-equipped hollow cathodes, traits which are well suited for low-power Hall-effect thrusters that are currently being developed for small satellite propulsion. Despite the advantages, there are concerns that the ignition process in heaterless hollow cathodes may impose an excessive burden on the propellant feed and/or electrical systems of a small satellite. To address this concern, a fixed-volume release flow protocol, which can be used to temporarily increase the propellant mass flow rate, was developed, modeled, and experimentally evaluated. The new protocol allowed for a heaterless hollow cathode to be ignited reliably with a moderate bias voltage and a minimal electrical power requirement. Specifically, a xenon fed heaterless hollow cathode was ignited with a 375 V bias using 17.3 mg of propellant. Repeating the tests with krypton showed that ignition could be achieved in the same heaterless hollow cathode assembly with a 300 V bias using 13.1 mg of propellant. We judge that a fixed-volume release system could be implemented in a satellite feed system while introducing minimal additional complexity.

Heaterless↗

Characterization of a Fixed-Volume Release System for Initiating an Arc Discharge in a Heaterless Hollow Cathode

Heaterless hollow cathodes may provide improved reliability, simplicity, and portability when compared with traditional heater-equipped hollow cathodes, traits which are well suited for low-power Hall-effect thrusters that are currently being developed for small satellite propulsion. Despite the advantages, there are concerns that the ignition process in heaterless hollow cathodes may impose an excessive burden on the propellant feed and/or electrical systems of a small satellite. To address this concern, a fixed-volume release flow protocol, which can be used to temporarily increase the propellant mass flow rate, was developed, modeled, and experimentally evaluated. The new protocol allowed for a heaterless hollow cathode to be ignited reliably with a moderate bias voltage and a minimal electrical power requirement. Specifically, a xenon fed heaterless hollow cathode was ignited with a 375 V bias using 17.3 mg of propellant. Repeating the tests with krypton showed that ignition could be achieved in the same heaterless hollow cathode assembly with a 300 V bias using 13.1 mg of propellant. We judge that a fixed-volume release system could be implemented in a satellite feed system while introducing minimal additional complexity.

Heaterless↗

Hollow Cathode and Keeper-region Plasma Measurements Using Ultra-fast Miniature Scanning Probes

In order to support the development of comprehensive performance and life models for future deep space missions that will utilize ion thrusters, we have undertaken a study of the plasma structure in hollow cathodes using an new pneumatic scanning probe diagnostic. This device is designed to insert a miniature probe directly into the hollow cathode orifice from either the upstream insert region in the interior of the hollow cathode, or from the downstream keeper-plasma region at the exit of the hollow cathode, to provide complete axial profiles of the discharge plasma parameters. Previous attempts to diagnose this region with probes was Limited by the melting of small probes in the intense discharge near the orifice, or caused significant perturbation of the plasma by probes large enough to survive. Our new probe is extremely compact, and when configured as a single Langmuir probe, the ceramic tube insulator is only 0.5mm in diameter and the current collecting conductor has a total area of 0.002 cm2. A series of current-voltage characteristics are obtained by applying a rapid sawtooth voltage waveform to the probe as it is scanned by the pneumatic actuator into and out of the plasma region, The bellow-sealed pneumatic drive scans the probe 4 cm in the cathode insert region and 10 cm in the anode/keeper plasmas region at average speeds of about 1 mm/msec, and the residence time at the end of the insertion stroke in the densest part of the plasma near the orifice is measured to be only 10 msec. Since the voltage sweep time is fast compared to the motion of the probe, axial profiles of the plasma density, temperature and potential with reasonable spatial resolution are obtained. Measurements of the internal cathode pressures and the axial plasma-parameter profiles for a hollow cathode operating at discharge currents of up to 35 A in xenon will be presented.

plasma generation↗

Flexural fatigue of hollow rolling elements

Hollow cylindrical bars were tested in the rolling-contact fatigue tester to determine the effects of material and outside diameter to inside diameter (OD/ID) ratios of 2.0, 1.6, 1.4, and 1.2 on fatigue failure mode and subsequent failure propagation. The range of applied loads with these OD/ID ratios resulted in maximum tangential tensile stresses ranging from 165 to 655 megapascals (24,000 to 95,000 psi) at the bore surface. Flexural failures of the hollow test bars occurred when this bore stress was 490 megapascals (71,000 psi) or greater with AISI 52100 hollow bars and 338 megapascals (49,000 psi) or greater with AISI M-50 hollow bars. Good correlation was obtained in relating the failures of these hollow bars with flexural failures of drilled balls from previously published full scale bearing tests.

Bamberger, E. N.↗

Effect of wall thickness and material on flexural fatigue of hollow rolling elements

Hollow cylindrical bars were tested in a rolling-contact fatigue tester to determine the effects of material and outside diameter to inside diameter (OD/ID) ratios on fatigue failure mode and subsequent failure propagation. The range of applied loads with OD/ID ratios of 2.0, 1.6, 1.4, and 1.2 resulted in maximum tangential tensile stresses ranging from 165 to 655 MPa at the bore surface. Flexural failures of the hollow test bars occurred when this bore stress was 490 MPa or greater with AISI 52100 hollow bars and 338 MPa or greater with AISI M-50 hollow bars. Good correlation was obtained in relating the failures of these hollow bars with flexural failures of drilled balls from full-scale bearing test published previously.

Bamberger, E. N.↗

Three dimensional simulation of the operation of a hollow cathode electron emitter on the Shuttle orbiter

Several researchers have suggested using hollow cathodes as plasma contactors for electrodynamic tethers, particularly to prevent the shuttle orbiter from charging to large negative potentials. Previous studies have shown that fluid models with anomalous scattering can describe the electron transport in hollow cathode generated plasmas. An improved theory of the hollow cathode plasmas is developed and computational results using the theory are compared with laboratory experiment. Numerical predictions for a hollow cathode plasma source of the type considered for use on the shuttle are presented as are three-dimensional NASCAP/LEO calculations of the emitted ion trajectories and the resulting potentials in the vicinity of the orbiter. The computer calculations show that the hollow cathode plasma source makes vastly superior contact with the ionospheric plasma compared with either an electron gun or passive ion collection by the orbiter.

Davis, V. A.↗