SEARCH · Engineering Papers
Results for “high resolution microscopy”
Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.
Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.
Characterization of Stress Corrosion Cracking Initiation Precursors in Cold-Worked Alloy 690 Using Advanced High-Resolution Microscopy
Although highly cold-worked UNS N06690 has been shown to be susceptible to stress corrosion crack growth in pressurized water reactor primary water, it is unclear whether cold-work promotes stress corrosion crack initiation under constant load test conditions. To evaluate the stress corrosion cracking initiation response, constant load tensile and blunt notch compact tension testing were performed on 21% and 31% cold-worked samples from two thermally treated UNS N06690 materials in 360 °C simulated pressurized water reactor primary water. High-resolution examinations were conducted mid- and post-test to record the evolution of grain boundary precursor damage and intergranular crack nucleation by focused ion beam milling combined with scanning electron microscopy and by transmission electron microscopy. The surface and sub-surface morphology of intergranular cavities, local corrosion and shallow cracks were documented. Nanometer-sized cavities were observed associated with grain boundary carbides in all specimens. The 31% cold-work specimens consistently exhibited shallow intergranular cracks with oxidized crack flanks and a high density of cavities ahead of the oxide front. Three-dimensional distribution of carbides and cavities ahead of the cracked grain boundaries was analyzed to gain mechanistic insights into the processes that lead to crack initiation in highly cold-worked UNS N06690.
Random vs realistic amorphous carbon models for high resolution microscopy and electron diffraction
Amorphous carbon and amorphous materials in general are of particular importance for high resolution electron microscopy, either for bulk materials, generally covered with an amorphous layer when prepared by ion milling techniques, or for nanoscale objects deposited on amorphous substrates. In order to quantify the information of the high resolution images at the atomic scale, a structural modeling of the sample is necessary prior to the calculation of the electron wave function propagation. It is thus essential to be able to reproduce the carbon structure as close as possible to the real one. The approach we propose here is to simulate a realistic carbon from an energetic model based on the tight-binding approximation in order to reproduce the important structural properties of amorphous carbon. At first, we compare this carbon with the carbon obtained by randomly generating the carbon atom positions. In both cases, we discuss the limit thickness of the phase object approximation. In a second step, we show the influence of both carbons models on (i) the contrast of Cu, Ag, and Au single atoms deposited on carbon and (ii) the determination of the long-range order parameter in CoPt bimetallic nanoalloys.
Introduction to special issue of Micron : biological specimen preparation and preservation for high resolution microscopies.
No abstract prepared.
Defect Physics in Photovoltaic Materials Revealed by Combined High-Resolution Microscopy and Density-Functional Theory Calculation
Explore the source record for details and available documents.
Data Report: High-Resolution Microscopy Images of Sediments from Green Canyon Block 955, Gulf of Mexico
We took Leica microscopy images of sediment samples acquired at Holes H002 (4 samples) and H005 (1 sample) during the UT-GOM2-1 Expedition in Green Canyon Block 955, in the northern Gulf of Mexico. A total of 37 images were acquired. The images document a prevalence of spherical conchoidal minerals, cleavage planes typical of feldspar or mica, and black fragmented minerals which stand out from the surrounding matrix. Drilling mud intrusion is thought to contribute to a grey metallic matrix observed across multiple samples.
Apparatus and method to achieve high-resolution microscopy with non-diffracting or refracting radiation
An imaging system employing a coded aperture mask having multiple pinholes is provided. The coded aperture mask is placed at a radiation source to pass the radiation through. The radiation impinges on, and passes through an object, which alters the radiation by absorption and/or scattering. Upon passing through the object, the radiation is detected at a detector plane to form an encoded image, which includes information on the absorption and/or scattering caused by the material and structural attributes of the object. The encoded image is decoded to provide a reconstructed image of the object. Because the coded aperture mask includes multiple pinholes, the radiation intensity is greater than a comparable system employing a single pinhole, thereby enabling a higher resolution. Further, the decoding of the encoded image can be performed to generate multiple images of the object at different distances from the detector plane. Methods and programs for operating the imaging system are also disclosed.
Pushing the limits of high-resolution polymer microscopy using antioxidants
High-resolution transmission electron microscopy (HRTEM) has been transformative to the field of polymer science, enabling the direct imaging of molecular structures. Although some materials have remarkable stability under electron beams, most HRTEM studies are limited by the electron dose the sample can handle. Beam damage of conjugated polymers is not yet fully understood, but it has been suggested that the diffusion of secondary reacting species may play a role. As such, we examine the effect of the addition of antioxidants to a series of solution-processable conjugated polymers as an approach to mitigating beam damage. Characterizing the effects of beam damage by calculating critical dose D c values from the decay of electron diffraction peaks shows that beam damage of conjugated polymers in the TEM can be minimized by using antioxidants at room temperature, even if the antioxidant does not alter or incorporate into polymer crystals. As a consequence, the addition of antioxidants pushes the resolution limit of polymer microscopy, enabling imaging of a 3.6Å lattice spacing in poly[(5,6-difluoro-2,1,3-benzothiadiazol-4,7-diyl)-alt-(3,3"-di(2-octyldodecyl)-2,2';5',2";5",2"-quaterthiophene-5,5"-diyl)] (PffBT4T-2OD).
Overcoming the field-of-view to diameter trade-off in microendoscopy via computational optrode-array microscopy
High-resolution microscopy of deep tissue with large field-of-view (FOV) is critical for elucidating organization of cellular structures in plant biology. Microscopy with an implanted probe offers an effective solution. However, there exists a fundamental trade-off between the FOV and probe diameter arising from aberrations inherent in conventional imaging optics (typically, FOV < 30% of diameter). Here, we demonstrate the use of microfabricated non-imaging probes (optrodes) that when combined with a trained machine-learning algorithm is able to achieve FOV of 1x to 5x the probe diameter. Further increase in FOV is achieved by using multiple optrodes in parallel. With a 1 × 2 optrode array, we demonstrate imaging of fluorescent beads (including 30 FPS video), stained plant stem sections and stained living stems. Our demonstration lays the foundation for fast, high-resolution microscopy with large FOV in deep tissue via microfabricated non-imaging probes and advanced machine learning.
High-resolution magnetic microscopy applications using nitrogen-vacancy centers in diamond
Magnetic microscopy with high spatial resolution helps to solve a variety of technical problems in condensed-matter physics, electrical engineering, biomagnetism, and geomagnetism. In this work we used quantum diamond magnetic microscope (QDMM) setups, which use a dense uniform layer of magnetically-sensitive nitrogen-vacancy (NV) centers in diamond to image an external magnetic field using a fluorescence microscope. We used this technique for imaging few-micron ferromagnetic needles used as a physically unclonable function (PUF) and to passively interrogate electric current paths in a commercial 555 timer integrated circuit (IC). As part of the QDMM development, we also found a way to calculate ion implantation recipes to create diamond samples with dense uniform NV layers at the surface. This work opens the possibility for follow-up experiments with 2D magnetic materials, ion implantation, and electronics characterization and troubleshooting.
Microfabrication of a Chamber for High-Resolution, In Situ Imaging of the Whole Root for Plant–Microbe Interactions
Fabricated ecosystems (EcoFABs) offer an innovative approach to in situ examination of microbial establishment patterns around plant roots using nondestructive, high-resolution microscopy. Previously high-resolution imaging was challenging because the roots were not constrained to a fixed distance from the objective. Here, we describe a new ‘Imaging EcoFAB’ and the use of this device to image the entire root system of growing Brachypodium distachyon at high resolutions (20×, 40×) over a 3-week period. The device is capable of investigating root–microbe interactions of multimember communities. We examined nine strains of Pseudomonas simiae with different fluorescent constructs to B. distachyon and individual cells on root hairs were visible. Succession in the rhizosphere using two different strains of P. simiae was examined, where the second addition was shown to be able to establish in the root tissue. The device was suitable for imaging with different solid media at high magnification, allowing for the imaging of fungal establishment in the rhizosphere. Overall, the Imaging EcoFAB could improve our ability to investigate the spatiotemporal dynamics of the rhizosphere, including studies of fluorescently-tagged, multimember, synthetic communities.
Direct observation of the intergrown {alpha}-phase in {beta}-TmAlB{sub 4} via high-resolution electron microscopy
A TmAlB{sub 4} crystal with a ThMoB{sub 4}-type ({beta}-type) structure phase related to a hexagonal AlB{sub 2}-type structure was studied by electron diffraction and high-resolution electron microscopy. A high-resolution image clearly exhibits an intergrown lamellar structure of a YCrB{sub 4}-type ({alpha}-type) phase in the matrix of the {beta}-type phase in TmAlB{sub 4} crystal. The lamellar structure can be characterized by a tiling of deformed hexagons, which are a common structure unit in the {alpha}-type and {beta}-type structures. The intergrown nanostructure is considered to be attributed to the origin of low temperature anomalies in physical properties.
Leveraging Super High Optical Resolution Microscopy to Probe the Interaction Zone Between Clostridium thermocellum and Biomass
This presentation is about the leveraging super high optical resolution microscopy to probe the interaction zone between clostritium thermocellum and biomass.
High Resolution Electron Microscopy Of Dislocation Ribbons In A CMSX-4 Superalloy single crystal
High-resolution scanning transmission electron microscopy (HR STEM) has been used to study the structure of dislocations in single crystal superalloy samples that have been subjected to conditions that favour the primary creep regime. The study has revealed the detailed structure of extended a 2 h112i dislocations as they shear the 0 precipitates during creep. These dislocations dissociate in a manner that is consistent with the PFMD predictions made and also suggests the importance of the reordering process during their movement. The shearing done by the ah112i dislocationswas also found to distort the/ 0 interface, changing its appearance from linear to a 'saw tooth' pattern. Another important observation was the segregation of alloying element with high atomic mass to the stacking faults to reduce their energies during shear. Numerous a 2 h110i dissociated dislocations were also observed in the channels of the superalloy. The high resolution provided by the STEM imaging enables one to study the high energy faults that are usually di*cult to observe in conventional weak-beam TEM, such as CISF and CESF-1 in the 0 andthe ISF in the, and to make estimates of their energies. Key
High-Resolution Electron Microscopy Investigations of Structure and Morphology of Cadmium Selenide Nanocrystals
The paper presents high-resolution electron microscopy investigations of the structure and morphology of cadmium selenide nanocrystals and nanoplatelets, and nanoplatelets having cadmium selenide core/crown nanostructure. These nanocrystals and nanoplatelets are obtained by the colloid technology and are deposited onto carbon substrates using the Langmuir–Blodgett method. It is shown that two-dimensional structures of nanocrystals and nanoplatelets can be formed on carbon substrates. The quantity specifications of these structures are determined in this paper.
Integration of piezoelectric and electrothermal actuators for high-resolution Atomic Force Microscopy
Not provided.
Final Technical Report for DE-FG02-06ER15835: Chemical Imaging with 100nm Spatial Resolution: Combining High Resolution Flurosecence Microscopy and Ion Mobility Mass Spectrometry
We have combined, in a single instrument, high spatial resolution optical microscopy with the chemical specificity and conformational selectivity of ion mobility mass spectrometry. We discuss the design and construction of this apparatus as well as our efforts in applying this technique to thin films of molecular semiconductor materials.