Material Plasma Exposure eXperiment (MPEX) High Heat Flux Bellows for Component Alignment in High Microwave Environment

The Material Plasma Exposure eXperiment (MPEX) device is a linear plasma device developed to perform plasma material interaction experiments under the conditions prototypic of a fusion reactor divertor. MPEX has multiple systems that must be precisely aligned to the plasma axis, including an electron cyclotron heating system that emits up to 400 kW of microwave power into the vacuum vessel. Five distinct systems require precise alignment on the MPEX device, thus requiring four bellows, all of which are adjacent to the plasma at a relatively high heat flux of approximately 47 kW/m2 and microwave power regions. The MPEX high heat flux bellows (HHFB) is designed to deliver 6 degrees of freedom positioning. The HHFB includes titanium–zirconium–molybdenum (TZM) inserts that are brazed into a Glidcop AL-15 body using a high-temperature braze alloy, thus blocking direct line of sight to an edge-welded bellows from the plasma and microwave screen to block microwaves from the bellows. Further, a custom ConFlat knife edge is machined into the Glidcop AL-15, so the vacuum flanges do not need a braze or weld joint on the vacuum interface. Fingerstock or copper mesh is used to restrict microwave power from entering the interstitial space between the water-cooled Glidcop AL-15 body and edge-welded bellows. Glidcop AL-15 was selected as the material of choice for the water-cooled body because it can maintain mechanical integrity at elevated temperatures, and it also allows for a high-temperature braze. TZM was selected for its machinability and compatibility with vacuum and plasma requirements. A test article is also being considered for a similarly shaped component, the MPEX limiter, that will demonstrate the integrity of the braze joint under high thermal load. Results from this testing will be extrapolated to deduce the lifetime and integrity of the HHFB design.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

SiC Microchannel Heat Sinks for High Heat Flux Dissipation of 1 kW/cm 2

Thermal management has become a major barrier in the development of high-power micro-devices. Microchannel heat sinks (MCHS) are a promising method to dissipate high heat fluxes from high power density devices. Reducing the thermal resistance will reduce the temperature increase of the electronic device, allowing for higher powers to be achieved while maintaining a safe operating temperature. This paper reports on the use of silicon carbide (Sic) microchannels to dissipate high heat fluxes up to 1 kW/cm 2 over a footprint of 0.25 cm 2 . The use of high aspect ratio and decreased hydraulic diameter channels has allowed for very low thermal resistances to be achieved at higher heat duties compared to previous studies. The experiments performed resulted in heater temperatures of less than 60 °C and thermal resistances as low as 0.024 cm 2 . ° $C$/W between the heater surface and fluid inlet temperature. In conclusion, the demonstrated thermal performance of the SiC MCHS is an encouraging means for dissipating heat from high power density microelectronic devices.

42 ENGINEERING↗

Material Plasma Exposure eXperiment High Heat Flux Microwave Absorber Design, Manufacture, and Articles Test

The Material Plasma Exposure eXperiment (MPEX) at Oak Ridge National Laboratory is in the final design phase. MPEX will be capable of exposing neutron-irradiated materials to plasmas for the study of plasma-material interaction. This facility will provide information about the complex effects of plasmas on materials and contribute to examining new materials that can withstand high heat fluxes and high ion fluences for future fusion devices. MPEX plasma is heated by 70-GHz or 105-GHz electron Bernstein wave/electron cyclotron heating (ECH), and the high-frequency microwaves are prone to scattering microwave power, which can have detrimental effects, especially on diagnostic components. A large portion of the injected ECH power is expected to be absorbed by plasma, but the remainder requires that microwave absorbers be placed immediately upstream and downstream of the ECH launcher to minimize stray microwaves leaving the ECH region. These microwaves can inadvertently heat components that cannot be shielded or otherwise protected. The microwave absorber design is based on an array of pyramid-shaped ceramic tiles brazed to a water-cooled explosion-bonded heat sink and a stainless steel plate to produce one tile module. Computational fluid dynamics and structural analyses were performed to optimize and validate the design. Multiple test coupons were produced to validate the process for brazing the two different tile materials to the Glidcop AL-15 baseplate. The articles were tested to evaluate the reliability and thermal performance through exposure to an electron beam with a heat flux of up to 1.5 MW/m2. Nondestructive testing was performed before and after testing to identify voids or separations that may have been introduced by the high heat flux. This paper discusses the details of high heat flux microwave absorber design, manufacturing details and associated challenges, and test results, demonstrating the effectiveness of the proposed design.

Hussain, Aftab↗

Thermo-Mechanical Distortion of Tungsten-Coated Steel During High Heat Flux Testing Using Plasma Arc Lamps

An experimental setup and a test section were designed and fabricated for high heat flux testing (HHFT) of neutron-irradiated specimens using water-wall plasma arc lamps. Because of the radiological considerations and limitations of reactor irradiation, the size of the test articles was limited to disks less than 10 mm in diameter. The specimen was clamped onto an actively cooled block, and clamping allowed the insertion of several thermocouples on the back surface of the specimen through a copper (Cu) block. Five vacuum plasma sprayed tungsten (W)–coated F82H steel specimens were subjected to HHFT. Surface profilometry measurements, which were conducted after HHFT, revealed central bowing of the top W surface. This type of residual distortion occurred for all of the specimens, and the larger the specimens were, the larger was the distortion.In an attempt to understand specimen distortion and address the science questions related to the testing of subsize specimens during HHFT, a simplified thermo-mechanical model was developed. By using a measured temperature in the Cu as an isothermal boundary condition, the model eliminated the need for coupling cooling fluid flow models with stress models, greatly simplifying the analysis. The main variable in the proposed model is hC, i.e., the thermal contact conductance between the F82H and the Cu washer. Inelastic properties, including hardening properties, were considered for F82H steel and Cu. Numerical simulation results demonstrated a buildup of residual deformation during HHFT and a very complex state of stress and deformation during typical heat flux (HF) cycling. Additionally, hoop stress evolution during a high heat flux cycle reveals that F82H at an interface with W would be mainly in compression during HF application and experienced a transition to a tension state during cooldown. Also, specimen distortion evolves during each HF cycle, as the specimen bows downward during HF application and upward during the cooldown period between HF cycles. The final specimen distortion, i.e., upward bowing of the specimen center, was qualitatively predicted for hC values of 4000 to 5000 W/(m 2 ·K). This hC range of values, for which bulging is obtained, is at the lower spectrum of the range of values for hC, consistent with the low thermal contact conductance expected from the unpolished F82H surface.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

MPEX High Heat Flux Plasma Dump Design, Manufacture, and Articles Test

Here, the Material Plasma Exposure eXperiment (MPEX) device is a steady-state linear plasma device currently in the final design phase at the Oak Ridge National Laboratory. This device will reach ion fluences up to 10 31 m -2 and will be used to expose neutron-irradiated materials to divertor-relevant plasmas and to study the effects of plasma-material interactions. These studies will elucidate the complex effects of plasmas with divertor candidate materials capable of withstanding high heat flux and high fluences for next-generation fusion devices. Bidirectional plasma will be generated using a high-power (200 kW) helicon source. Plasma will be confined by superconducting magnets. The last plasma-facing component on the upstream side of the MPEX device is the dump, which has been designed to intercept plasma and energetic particles. The dump will have a total heat load of 9.2 kW. A copper alloy (Glidcop AL-15) was selected for use in the water-cooled flange design because of its high thermal conductivity, its retaining strength at elevated temperatures, and its ability to be used in the high-temperature braze joints used in this application. Titanium-zirconium-molybdenum (TZM) tiles are brazed to the Glidcop AL-15 flange using high-temperature braze alloy. External water-cooling channels are used on the dump flange to prevent water leakage inside the vacuum space. This article discusses the details of the high heat flux dump design, including the computational fluid dynamics (CFD) and structural analyses performed to validate the design to meet the operational requirements of the MPEX device.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Design and Analysis of High Heat Flux Plasma-Facing Components for NSTX Upgrade

The National Spherical Tokamak Experiment (NSTX) upgrade (NSTX-U) requirements lead to enhanced heat loads on plasma-facing components (PFCs) especially in the divertor regions, where normal heat flux density can reach up to 8 MW/m 2 . For these high heat flux (HHF) regions, the PFCs were redesigned, to use castellations which relieved the thermal stresses associated with high incident heat flux. Another design feature of HHF PFCs is the absence of front face mounting holes which create localized areas of high temperature and thermal stress concentrations. Optimized shaping of the front face of the HHF PFCs eliminates regions where the front face is perpendicular to the heat flux direction during normal helicity operation and spreads the heat load. A unique mechanism was designed to connect PFC tiles to the NSTX-U center stack casing using locking features accessible from the low heat flux regions. Isotropic graphite was selected as the HHF PFC tile material. Initial tile design parameters were accessed using analytical expressions for pulsed heat flux loading. A working prototype of the locking mechanism was created during the initial stages of the design to prove the concept performance. This article presents an overview of the divertor HHF PFC design and the results of the thermal and structural analyses performed using ANSYS software. The results of the analyses cover normal operating conditions and disruptions which impose electromagnetic (EM) loads from eddy and halo currents. The 3-D, transient, nonlinear analyses took into account the temperature-dependent properties of the materials, friction interfaces between the parts, and variable electric properties of the parts and interfaces. The results confirm that the HHF PFC tiles remain within the allowable limits for the loads defined by the NSTX-U Recovery Project. In addition, tolerance stack up analyses were performed to ensure tile performance in the worst possible assembly configuration. Finally, the design process was completed successfully, and the NSTX HHF PFC tiles are currently in the production phase.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Development of a Hybrid Single/Two-Phase Capillary-Based Micro-Cooler Using Copper Inverse Opals Wick with Silicon 3D Manifold for High-Heat-Flux Cooling Application: Preprint

Previously, two-phase capillary-based cooling from narrow (200-1,000 micrometer) heater-bridge copper inverse opal (CIO) wicks with heat flux levels exceeding 1,400 watts per square cm with a low superheat of approximately 10 degrees C was demonstrated. Here, we demonstrate the area scaling of the proposed technology to large-area micro-cooler for the high-heat-flux cooling of microprocessors and power electronics. We developed a hybrid single/two-phase micro-cooler that relies on capillary wicking in 25-micrometer-thick CIOs with an open channel silicon 3D-manifold for liquid delivery and vapor extraction, to achieve a high heat flux of approximately 400 watts per square cm over a heated area of 1 square cm. For the range of inlet water (21 degrees C water temperature) flowrates from 5 to 60 mL per min, we achieved total thermal resistances and vapor qualities of 0.68-0.2 square cm Kelvin per watt and 0.55-0.12, respectively. The high heat flux levels are achieved with flowrates that are 10 times smaller than conventional single- or two-phase microchannel cooling technology. The corresponding two-phase thermal resistances are in the range of 0.05 to 0.02 square cm Kelvin per watt with temperature superheat of 8 to 6 degrees C. While the overall performance of the large-area (10 by 10 square millimeter) capillary-based micro-cooler degraded compared to previous demonstration of the technology for a heated area of 5 by 5 square millimeter, preliminary computational fluid dynamics (CFD) modeling indicates that an improved manifold design will be able to achieve comparable performance.

capillary flow↗

Design, fabrication, and testing of a water-cooled tungsten-foam high-heat flux plasma-facing module

Here, we present a comprehensive study detailing the design, fabrication and testing a new modular “finger” component, featuring a hexagonal tungsten foam armor tile bonded to the top surface of the water-cooled finger unit. The mechanical, thermal, and particle transport properties of the tungsten foam armor were determined for a wide range of porosity and cell size, and then combined in an equivalent solid material with “effective” properties suitable for large-scale simulations. A series of 3-D multiphysics simulations for coupled thermal and mechanical behavior of the “finger” module are used to optimize the design before fabrication. The simulation results show that, for the expected experimental conditions, a safe range of heat flux and foam porosity is possible for both water-cooling and helium-cooling. Based on these multiphysics simulations, an optimum finger cooling module has been fabricated at Ultramet, Inc. A series of experiments were designed to study the thermomechanical performance of the “finger” unit under steady-state and transient thermal loading at surface heat flux up to 16 MW/m 2 in the High Energy Flux Test facility (HEFTY) at UCLA. Testing conditions included low-power, steady-state plasma exposure at 6 MW/m 2 , followed by severe high heat flux cycles at 16 MW/m 2 . Results of these tests are explained through comparisons with multiphysics simulations. To eliminate the effects of thermomechanical damage carried out on a module on its thermo-mechanical response on a subsequent test, three different yet identically designed and fabricated finger modules were tested. The results show that the current design is capable of cooling the walls of fusion devices at surface heat flux up to 6 MW/m 2 without failure, and that the failure heat flux limit is below 16 MW/m 2 .

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Development of a Hybrid Single/Two-Phase Capillary-Based Micro-Cooler using Copper Inverse Opals Wick with Silicon 3D Manifold for High-Heat-Flux Cooling Application

Previously, we reported two-phase capillary-based cooling using narrow (200 to 1000 ..mu..m) heater bridge copper inverse opal (CIO) wicks with heat flux level of 1400 Wcm -2 and superheat ~ 10 degrees C. Here, we demonstrate the area scaling of the proposed technology to a large-area micro-cooler for high-heat-flux cooling of microprocessors and power electronics. We developed a hybrid single/two-phase micro-cooler that relies on capillary-wicking in a 25-..mu..m-thick CIO with an open silicon microchannel 3D-manifold for liquid delivery and vapor extraction, achieving a high heat flux ~ 400 Wcm -2 over a heated area of 10 x 10 mm 2 . For a range of inlet water flowrates from 5 to 60 g(min) -1 , we achieved total thermal resistances and vapor qualities of 0.68 cm 2 degrees CW -1 to 0.2 cm 2 degrees CW -1 and 0.55 to 0.12, respectively. The flowrates are 10x smaller than those of conventional single- or two-phase microchannel cooling technology. The corresponding two-phase thermal resistances ranges from 0.05 to 0.02 cm 2 degrees CW -1 with temperature superheat of 8 to 6 degrees C, respectively. While the overall performance of the large-area (10 x 10 mm 2 ) capillary-based micro-cooler degraded compared to the previous demonstration of the technology for a heated area of 5 x 5 mm 2 , however, preliminary CFD modeling indicates that an improved manifold design will be able to achieve comparable performance.

capillary flow↗

Plasma-arc lamp high heat flux cycling exposure of neutron irradiated tungsten materials

Thick plate, unalloyed W was neutron irradiated in the High Flux Isotope Reactor (HFIR) at 550 °C to a fast fluence of 1.24 × 10 25 n m -2 E > 0.1 MeV (~0.24 dpa). Unirradiated and irradiated specimens of the material were high heat flux (HHF) tested in the Plasma Arc Lamp (PAL) facility. The PAL uses a high-power photon source to provide a broad and even heat distribution on the sample surface. To simulate on/off cycling of normal operating plasma, the samples were exposed to approximately 800 cycles at 4.73 MW m -2 absorbed heat flux (incident heat fluxes of 10.95 MW m -2 ). Additionally, after PAL exposure, slight changes were observed on the surfaces of the samples with SEM. The samples showed some annealing in the near surface polished region, but they were all below the damage threshold for cracking or other destructive features. The PAL has a large parameter space for future testing. The use of the HFIR and PAL to sequentially expose neutron irradiated samples to HHF will be a powerful tool for understanding materials behavior in a fusion-like environment.

36 MATERIALS SCIENCE↗

Capillary-Enhanced Two-Phase Micro-Cooler Using Copper-Inverse-Opal Wick with Silicon Microchannel Manifold for High-Heat-Flux Cooling Application

In this work, we demonstrate a two-phase capillary-fed boiling micro-cooler that consists of a ~ 25-..mu..m-thick copper inverse opal (CIO) porous wicking structure for high-heat-flux boiling and a silicon 3D-manifold for distributed liquid delivery and vapor extraction across a 0.5 cm x 0.5 cm heated area. At low inlet water mass flow rates of 1.5 to 1.9 g(min)-1, the micro-cooler displays nearly two-phase boiling with exit vapor quality ~ 1 and a high critical heat flux (CHF) of 253 to 320 W cm-2 with low superheat of ~ 10 degrees C resulting in a thermal resistance of boiling ~ 0.025 cm2 degrees C W-1 or heat transfer coefficient of 0.4 MW m-2 degrees C-1. For higher flow rates of 5, 10, and 15 g(min)-1, the micro-cooler exhibits a hybrid single-phase and two-phase cooling regime where the contribution of the sensible heat (single-phase) cooling is linearly added to that of the two-phase cooling. For the highest flow rate of 15 g(min)-1, the CHF is increased to ~ 500 W cm-2 resulting in an overall thermal resistance of ~ 0.18 cm2 degrees C W-1. However, the two-phase heat transfer effectiveness, which estimates the utilization level of the inlet mass flow rate for two-phase boiling, is reduced to ~ 0.11. To achieve the best cooling system performances, the micro-cooler must operate entirely within the two-phase boiling regime (exit vapor quality or two-phase heat transfer effectiveness ~ 1). Ideally, the "coolant" should be delivered near its saturation temperature (~ 100 degrees C for water), which provides significant advantages for the energy-efficient operation of data centers and power electronics. We present detailed analysis with Infrared and high speed camera images at various inlet flow rates and heat fluxes to understand complex heat transfer in the micro-cooler. Furthermore, a conjugate thermofluidic simulation model, which incorporates the physics of capillary-fed boiling in a porous copper layer, agrees well with the experimental data.

capillary-enhanced boiling↗

High Heat Flux Testing of Castellated Graphite Plasma- Facing Components

As part of the recovery project of the National Spherical Tokamak Experiment–Upgrade (NSTX-U), the divertor plasma-facing components (PFCs) were redesigned to handle significantly higher heat fluxes and longer pulse lengths than NSTX. The design process resulted in a castellated, graphite PFC tile. To verify the thermal performance of this design, dedicated electron beam, high heat flux (HHF) testing was carried out on a de-optimized mock-up PFC target. These tests demonstrated that the tile design is itself robust to large, localized thermal gradients. No mechanical damage to the mock-up was observed during HHF testing, though the actual PFC tile mechanical tie-down was not tested. Rather, when the surface temperature exceeded the sublimation temperature of graphite, carbon blooms from the mock-up tile surface were observed. Finally, this resulted in 1 to 2 mm of surface material ablating from the mock-up after repeated, highly localized electron beam exposures.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Review of Thermal Contact Resistance of Flexible Graphite Materials for Thermal Interfaces in High Heat Flux Applications

In this report the data is reviewed on thermal contact conductance (TCC) and/or thermal contact resistance (TCR) at material interfaces which employs flexible graphite (FG) materials as thermal interface materials (TIM). FG materials are often used as TIM due to their conforming nature. While the overall TCR can be estimated straightforward from measured data, the interface TCR is much more difficult to obtain. The report also discusses the interfacial thermal contact conductance between FG-tungsten and FG-Glidcop-Al15, which are envisioned for high-heat flux applications.

36 MATERIALS SCIENCE↗

Development of Readily Available & Robust High Heat Flux Gardon Gauges

Concentrated solar power (CSP) technologies deliver concentrated solar energy as a heat source to industrial processes, power generation cycles, and chemical cycles. CSP systems require accurate and reliable high flux measurements, and next generation CSP systems will require flux measurement up to 1000 W/cm2. Existing flux measurement devices do not comprehensively meet the flux rating, cycle life, cost, and lead-time needs of stakeholders, necessitating the development of an improved flux sensor. In this study, Sandia National Laboratories (SNL) partnered with Hukseflux Thermal Sensors to develop a low-cost, short lead-time, and robust flux sensor rated to 250 W/cm2. Three prototype circular foil gauge designs were assessed for performance at the National Solar Thermal Test Facility (NSTTF) at SNL. Each gauge design measured flux up to 250 W/cm2 with <5% measurement error. Following baseline error quantification, gauges were exposed to flux above 500 W/cm2 to assess gauge failure mechanisms. Gauges physically survived >500 W/cm2 flux exposure, but measurement error was found to increase after foil coatings reached 400 °C. The results of this study suggest that coating optical properties change at excessive temperatures and that foil coating temperature, rather than heat flux level, dictates the acceptable gauge measurement range.

McLaughlin, Luke (ORCID:0000000303711310)↗

Film condensation with high heat fluxes and scaled experiments using pure steam for reactor containment cooling

Condensation tests were performed using a newly developed test facility for scaling the passive containment cooling system (PCCS) to a small modular reactor (SMR). The PCCS of the SMR plays a pivotal role in ensuring greater safety, reliability, and compactness than what is afforded by traditional reactors. Therefore, a well-designed PCCS is essential to SMRs. However, previous studies and test data were unsuitable for scaling, due to high variation in the test geometry and operating conditions. This study intends to close this research gap by using a novel designed scaled test facility consisting of vertical condensing test sections featuring 1-, 2-, and 4-inch-diameter condensing tubes with annular water cooling, and by applying superheated and saturated steam with different steam mass flow ranges of 5–25 g/s. Further, the primary test data, including axial temperatures, mass flow rates, and pressures, were used in conjunction with a standard data reduction method to estimate critical parameters such as heat fluxes, heat transfer coefficients, and condensation rates. These scaled test data would support improving empirical correlations and validating condensation models to identify scaling distortion for SMR PCCSs.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Morphological and nanomechanical changes in tungsten in high heat flux conditions

Abstract Morphological and nanomechanical alteration of tungsten in extreme environments, like those in edge localized modes in nuclear fusion environments, up to 46.3 GWm −2 heat fluxes were experimentally simulated using electrothermal plasma. Surface and subsurface damage to the tungsten is seen mainly in the form of pore formation, cracks, and resolidified melt instabilities. Mirco voids, rosette-type microfeatures, core-shell structure, particle enrichment, and submicron channels all manifest in the damaged subsurface. The formation of voids in the subsurface was determined to originate from the ductile fracture of hot tungsten by plastic flow but not developed to cracking. The voids were preferentially settled in grain boundaries, interfaces. The directionality of elongated voids and grains is biased to the heat flow vector or plasma pathway, which is the likely consequence of the thermally driven grain growth and sliding in the high-temperature conditions. The presence of a border between the transient layer and heat-affected zone is observed and attributed to plasma shock and thermal spallation of fractural tungsten at high temperature. Plasma peening-like hardening effects in tungsten were observed in the range of 22.7–46.3 GWm −2 but least in the case of the lowest heat flux, 12.5 GWm −2 .