Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “high field sensitivity”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Acoustic Sensing Fiber Coupled with Highly Magnetostrictive Ribbon for Small-Scale Magnetic-Field Detection

Fiber-optic sensing has shown promising development for use in detecting magnetic fields for downhole and biomedical applications. Coupling existing fiber-based strain sensors with highly magnetostrictive materials allows for a new method of magnetic characterization capable of distributed and high-sensitivity field measurements. This study investigates the strain response of the highly magnetostrictive alloys Metglas® 2605SC and Vitrovac® 7600 T70 using Fiber Bragg Grating (FBG) acoustic sensors and an applied AC magnetic field. Sentek Instrument’s picoDAS interrogated the distributed FBG sensors set atop a ribbon of magnetostrictive material, and the corresponding strain response transferred to the fiber was analyzed. Using the Vitrovac® ribbon, a minimal detectable field amplitude of 60 nT was achieved. Using Metglas®, an even better sensitivity was demonstrated, where detected field amplitudes as low as 3 nT were measured via the strain response imparted to the FBG sensor. Distributed FBG sensors are readily available commercially, easily integrated into existing interrogation systems, and require no bonding to the magnetostrictive material for field detection. The simple sensor configuration with nanotesla-level sensitivity lends itself as a promising means of magnetic characterization and demonstrates the potential of fiber-optic acoustic sensors for distributed measurements.

Dejneka, Zach (ORCID:0000000179415708)↗

Cross-polarized common-path temporal interferometry for high-sensitivity strong-field ionization measurements

Absolute density measurements of low-ionization-degree or low-density plasmas ionized by lasers are very important for understanding strong-field physics, atmospheric propagation of intense laser pulses, Lidar etc. A cross-polarized common-path temporal interferometer using balanced detection was developed for measuring plasma density with a sensitivity of ∼0.6 mrad, equivalent to a plasma density-length product of ∼2.6 × 10 13 cm −2 if using an 800 nm probe laser. By using this interferometer, we have investigated strong-field ionization yield versus intensity for various noble gases (Ar, Kr, and Xe) using 800 nm, 55 fs laser pulses with both linear (LP) and circular (CP) polarization. The experimental results were compared to the theoretical models of Ammosov-Delone-Krainov (ADK) and Perelomov-Popov-Terent’ev (PPT). We find that the measured phase change induced by plasma formation can be explained by the ADK theory in the adiabatic tunneling ionization regime, while PPT model can be applied to all different regimes. We have also measured the photoionization and fractional photodissociation of molecular (MO) hydrogen. By comparing our experimental results with PPT and MO-PPT models, we have determined the likely ionization pathways when using three different pump laser wavelengths of 800 nm, 400 nm, and 267 nm.

47 OTHER INSTRUMENTATION↗

Nanoscale covariance magnetometry with diamond quantum sensors

Nitrogen vacancy (NV) centers in diamond are atom-scale defects that can be used to sense magnetic fields with high sensitivity and spatial resolution. Typically, the magnetic field is measured by averaging sequential measurements of single NV centers, or by spatial averaging over ensembles of many NV centers, which provides mean values that contain no nonlocal information about the relationship between two points separated in space or time. In this work, we propose and implement a sensing modality whereby two or more NV centers are measured simultaneously, and we extract temporal and spatial correlations in their signals that would otherwise be inaccessible. We demonstrate measurements of correlated applied noise using spin-to-charge readout of two NV centers and implement a spectral reconstruction protocol for disentangling local and nonlocal noise sources.

47 OTHER INSTRUMENTATION↗

Engineering new limits to magnetostriction through metastability in iron-gallium alloys

Magnetostrictive materials transduce magnetic and mechanical energies and when combined with piezoelectric elements, evoke magnetoelectric transduction for high-sensitivity magnetic field sensors and energy-efficient beyond-CMOS technologies. The dearth of ductile, rare-earth-free materials with high magnetostrictive coefficients motivates the discovery of superior materials. Fe 1- x Ga x alloys are amongst the highest performing rare-earth-free magnetostrictive materials; however, magnetostriction becomes sharply suppressed beyond x = 19% due to the formation of a parasitic ordered intermetallic phase. Here, we harness epitaxy to extend the stability of the BCC Fe 1- x Ga x alloy to gallium compositions as high as x = 30% and in so doing dramatically boost the magnetostriction by as much as 10x relative to the bulk and 2x larger than canonical rare-earth based magnetostrictors. A Fe 1- x Ga x - [Pb(Mg 1/3 Nb 2/3 )O 3 ] 0.7 -[PbTiO 3 ] 0.3 (PMN-PT) composite magnetoelectric shows robust 90° electrical switching of magnetic anisotropy and a converse magnetoelectric coefficient of 2.0 × 10 -5 s m -1 . When optimally scaled, this high coefficient implies stable switching at ~80 aJ per bit.

36 MATERIALS SCIENCE↗

Detection and imaging of electric fields, using polarized neutrons

A method and corresponding apparatus are provided for measuring neutron spin precession in an electric field with high sensitivity suitable for practical applications in non-destructive testing, imaging, and the like. Production of a neutron beam with a polarization vector P is followed by transmitting the spin-polarized neutron beam through a sample region in which there is a target generating an electric field, polarization-analyzing the transmitted neutron beam with an analyzing direction orthogonal to P, detecting an intensity of the polarization-analyzed neutron beam; and mapping the detected neutron-beam intensity to a field-strength value for the target electric field.

Jau, Yuan-Yu↗

Lorentz electron ptychography for imaging magnetic textures beyond the diffraction limit

Nanoscale spin textures, especially magnetic skyrmions, have attracted intense interest as candidate high-density and power-efficient information carriers for spintronic devices. Facilitating a deeper understanding of sub-100 nm to atomic-scale spin textures requires more advanced magnetic imaging techniques. Here, we demonstrate a Lorentz electron ptychography (LEP) method which can enable high-resolution, high-sensitivity magnetic field imaging for widely-available electron microscopes. The resolution of LEP is not limited by the usual diffraction limit of the lens optics, but instead is determined by the maximum scattering angle at which a statistically meaningful dose can still be recorded – this can be an improvement of up to 2 to 6 times depending on the allowable dose. Using FeGe as a model system, we realize a more accurate magnetic field measurement of skyrmions with an improved spatial resolution and sensitivity by also correcting the probe damping effects from the imaging optics via LEP. This allows us to directly resolve subtle internal structures of magnetic skyrmions near the skyrmion cores, boundaries, and dislocations in an FeGe single crystal. Our study establishes a quantitative, high-resolution magnetic microscopy technique that can reveal the nanoscale spin textures, especially magnetization discontinuities and topological defects in nanomagnets. In conclusion, the technique’s high dose efficiency should also make it well-suited for the exploration of magnetic textures in electron radiation-sensitive materials such as organic or molecular magnets.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

Broadband Ultra-Sensitive Adiabatic Magnetometer

We introduce a new ultra-sensitive adiabatic magnetometer that has a broad bandwidth and can operate in the presence of magnetic fields and gradients. It follows conceptually typical implementations of atomic magnetometers based on alkali-metal vapor cells and lasers for optical pumping and optical Faraday effect detection, while its unique feature is a measurement of an oscillating magnetic field along the probe beam direction at frequencies lower than the resonant frequency, proportional to a static magnetic field along the pump beam direction. The bandwidth of the adiabatic magnetometer scales as the strength of the field along the pump beam. From our theoretical studies it is expected that the adiabatic magnetometer can reach 1 fT sensitivity with a bandwidth of 10 kHz, which any type of atomic magnetometers cannot achieve. Among anticipated various applications of this adiabatic magnetometer are biomagnetic sensing, nuclear magnetic resonance detection, and alkali-metal density measurements. In conclusion, we experimentally conducted alkali-metal density measurements, as an example of applications.

adiabatic magnetometer↗

DNA-assembled superconducting 3D nanoscale architectures

Studies of nanoscale superconducting structures have revealed various physical phenomena and led to the development of a wide range of applications. Most of these studies concentrated on one- and two-dimensional structures due to the lack of approaches for creation of fully engineered three-dimensional (3D) nanostructures. Here, we present a ‘bottom-up’ method to create 3D superconducting nanostructures with prescribed multiscale organization using DNA-based self-assembly methods. We assemble 3D DNA superlattices from octahedral DNA frames with incorporated nanoparticles, through connecting frames at their vertices, which result in cubic superlattices with a 48 nm unit cell. The superconductive superlattice is formed by converting a DNA superlattice first into highly-structured 3D silica scaffold, to turn it from a soft and liquid-environment dependent macromolecular construction into a solid structure, following by its coating with superconducting niobium (Nb). Through low-temperature electrical characterization we demonstrate that this process creates 3D arrays of Josephson junctions. This approach may be utilized in development of a variety of applications such as 3D Superconducting Quantum interference Devices (SQUIDs) for measurement of the magnetic field vector, highly sensitive Superconducting Quantum Interference Filters (SQIFs), and parametric amplifiers for quantum information systems.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

Quantum Sensed Electron Spin Resonance Discovery Platform (Final Report)

The properties of materials can change dramatically at the nanoscale new and useful properties can emerge. An example is found in the paramagnetism in iron oxide magnetic nanoparticles. Using magnetically sensitive nitrogen-vacancy centers in diamond, we developed a platform to study electron spin resonance of nanoscale materials. To implement the platform, diamond substrates were prepared with nitrogen vacancy centers near the surface. Nanoparticles were placed on the surface using a drop casting technique. Using optical and microwave pulsing techniques, we demonstrated T1 relaxometry and double electron-electron resonance techniques for measuring the local electron spin resonance. The diamond NV platform developed in this project provides a combination of good magnetic field sensitivity and high spatial resolution and will be used for future investigations of nanomaterials and quantum materials.

36 MATERIALS SCIENCE↗

Surface Roughness Effects from Additive Manufacturing in High Efficiency Gas Turbine Combustion Systems

In the past, clean combustion systems were characterized by high system development costs due to growing complexity and escalating manufacturing costs from conventional manufacturing processes. As a result, high efficiency concepts are difficult to design and more difficult to be cost-effectively manufactured. In recent years, with the introduction of additive manufacturing (AM) technologies, the rapid prototyping and mass production processes of clean combustion systems are promising to be significantly simplified with significant reduction in terms of engine manufacturing cost and engine energy cost. Compared with conventional manufacturing built parts, the AM process enabled a simpler design to be adopted for the nozzle, reducing the number of required braze and weld joints from twenty-five to just five. The resulting nozzle was 25% lighter and five times more durable and contributed to a 15% reduction in fuel burn in comparison with the previous model produced. Applying these improvements to a fleet of 5,000 turbofan engines at 150 kN thrust would result in fuel cost savings of $ \$ $6B annually (at $ \$ $5/gallon Jet-A fuel price, 700 gallon/hour fuel consumption rate, and 2,300 operational hours per year), and reduce CO2 emissions by more than 25 million tons per year. These advances support core Department of Energy (DOE) missions in energy efficiency, improving productivity, and environmental sustainability. Maximizing the benefit of these new capabilities will require high prediction capability of high speed turbulent flow with wall modeled Large Eddy Simulation (LES). GE Aviation maintains that advanced simulation technology and supercomputing is required in order to provide the appropriate boundary conditions to realize the maximum potential of AM and Ceramic Matrix Composite to reduce cooling flow, a first order penalty on the Brayton cycle. The algorithm developed using the ANSYS/Fluent software would provide the foundation for entirely new avenues of research and development with potential multi-billion dollar impact to the US economy, and significant reduction in carbon based emissions across the aerospace and power generation industries. The formulation of this iWLES (integral wall model for LES) is generic and allows to capture the changes in flow dynamics that have a significant impact on the wall bounded flow characteristics, such as swirler effective area, bulk swirl number, local pressure distribution, exit velocity profile, and turbulence kinetic energy profile. A periodic channel flow with rough flat plate is simulated using LES (Wall-Adapting Local Eddy-viscosity) model to verify the implementation of iWLES in the Fluent User Defined Function (UDF). As the flow fields are highly sensitive due to surface roughness of the wall bounded flows in the combustion systems, there is significant potential to conduct further LES studies focusing on the turbulence boundary layer interaction. Accurately capturing near wall physics will elucidate the impact of rough surfaces on combustor flow and aero-thermal interactions.

42 ENGINEERING↗

Surface Roughness Effects from Additive Manufacturing in High Efficiency Gas Turbine Combustion Systems

In the past, clean combustion systems were characterized by high system development costs due to growing complexity and escalating manufacturing costs from conventional manufacturing processes. As a result, high efficiency concepts are difficult to design and more difficult to be cost-effectively manufactured. In recent years, with the introduction of additive manufacturing (AM) technologies, the rapid prototyping and mass production processes of clean combustion systems are promising to be significantly simplified with significant reduction in terms of engine manufacturing cost and engine energy cost. Compared with conventional manufacturing built parts, the AM process enabled a simpler design to be adopted for the nozzle, reducing the number of required braze and weld joints from twenty-five to just five. The resulting nozzle was 25% lighter and five times more durable and contributed to a 15% reduction in fuel burn in comparison with the previous model produced. Applying these improvements to a fleet of 5,000 turbofan engines at 150 kN thrust would result in fuel cost savings of $6B annually (at $5/gallon Jet-A fuel price, 700 gallon/hour fuel consumption rate, and 2,300 operational hours per year),and reduce CO2 emissions by more than 25 million tons per year. These advances support core Department of Energy (DOE)missions in energy efficiency, improving productivity, and environmental sustainability. Maximizing the benefit of these new capabilities will require high prediction capability of high speed turbulent flow with wall modeled Large Eddy Simulation (LES). GE Aviation maintains that advanced simulation technology and supercomputing is required in order to provide the appropriate boundary conditions to realize the maximum potential of AM and Ceramic Matrix Composite to reduce cooling flow, a first order penalty on the Brayton cycle. The algorithm developed using the ANSYS/Fluent software would provide the foundation for entirely new avenues of research and development with potential multi-billion dollar impact to the US economy, and significant reduction in carbon based emissions across the aerospace and power generation industries. The formulation of this iWLES (integral wall model for LES) is generic and allows to capture the changes in flow dynamics that have a significant impact on the wall bounded flow characteristics, such as swirler effective area, bulk swirl number, local pressure distribution, exit velocity profile, and turbulence kinetic energy profile. A periodic channel flow with rough flat plate is simulated using LES (Wall-Adapting Local Eddy-viscosity) model to verify the implementation of iWLES in the Fluent User Defined Function (UDF). As the flow fields are highly sensitive due to surface roughness of the wall bounded flows in the combustion systems, there is significant potential to conduct further LES studies focusing on the turbulence boundary layer interaction. Accurately capturing near wall physics will elucidate the impact of rough surfaces on combustor flow and aero-thermal interactions.

99 GENERAL AND MISCELLANEOUS↗

High-resolution ultra-low field magnetic resonance imaging with a high-sensitivity sensing coil

We present high-resolution magnetic resonance imaging (MRI) at ultra-low field (ULF) with a proton Larmor frequency of around 120 kHz. The key element is a specially designed high-sensitivity sensing coil in the shape of a solenoid with a few millimeter gap between windings to decrease the proximity effect and, hence, increase the coil’s quality ([Formula: see text]) factor and sensitivity. External noise is strongly suppressed by enclosing the sensing coil in a copper cylindrical shield, large enough not to negatively affect the coil’s [Formula: see text] factor and sensitivity, measured to be 217 and 0.47 fT/Hz[Formula: see text], respectively. To enhance small polarization of proton spins at ULF, a strong pulsed 0.1 T prepolarization field is applied, making the signal-to-noise ratio (SNR) of ULF MRI sufficient for high-quality imaging in a short time. We demonstrate ULF MRI of a copper sulfate solution phantom with a resolution of [Formula: see text] and SNR of 10. The acquisition time is 6.3 min without averaging. The sensing coil size in the current realization can accommodate imaging objects of 9 cm in size, sufficient for hand, and it can be further increased for human head imaging in the future. Since the in-plane resolution of [Formula: see text] is typical in anatomical medical imaging, this ULF MRI method can be an alternative low-cost, rapid, portable method for anatomical medical imaging of the human body or animals. This ULF MRI method can supplement other MRI methods, especially when such methods are restricted due to high cost, portability requirement, imaging artifacts, and other factors.

59 BASIC BIOLOGICAL SCIENCES↗

Sensitivity of magnetic islands in permanent magnet stellarators using the gradient and Hessian methods

Stellarator plasmas are known to be very sensitive to perturbations in the magnetic field. The permanent magnet stellarator was in part developed as a solution to high machining tolerances placed on the shape properties of electromagnetic coils in traditional stellarators. However, as a consequence of this high sensitivity to the field structure, sensitivities of permanent magnet stellarator plasmas to perturbations of permanent magnet properties must necessarily be well-understood. The gradient and Hessian matrix methods have been previously demonstrated to be useful sensitivity analysis methods for modular coils. We apply these two methods to the study of island width sensitivities in both the MUSE and PM4STELL permanent magnet stellarator projects. These sensitivity methods were used to determine the relative impacts of permanent magnet parameter perturbations on island widths in the vacuum field approximation of both stellarator equilibria. The square of resonant magnetic field perturbation is used here as a proxy for island width. In particular, gradients of magnetizations of individual magnets were examined in MUSE, as well as gradients of magnet group displacements informed by device design. Three different forms of permanent magnet magnetization perturbations are investigated for MUSE, and the flux surface response to perturbations is demonstrated. The Hessian matrix method is applied to PM4STELL, illustrating the sensitivity of dominant island widths to displacements of toroidal wedge structures. These methods allow for selective direction of experimental resources toward regions of heightened sensitivity, while constraints on less impactful permanent magnet parameters can be relaxed.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Repeatability and sensitivity characterization of the far-field high-energy diffraction microscopy instrument at the Advanced Photon Source

In the last two decades, far-field high-energy diffraction microscopy (FF-HEDM) and similar non-destructive techniques have been actively developed at synchrotron light sources around the world. As these techniques (and associated analysis tools) are becoming more available for the general users of these light sources, it is important and timely to characterize their performance and capabilities. In this work, the FF-HEDM instrument implemented at the 1-ID-E endstation of the Advanced Photon Source (APS) is summarized. The set of measurements conducted to characterize the instrument's repeatability and sensitivity to changes in grain orientation and position are also described. When an appropriate grain matching method is used, the FF-HEDM instrument's repeatability is approximately 5 µm in translation, 0.02° in rotation, and 2 × 10 −4 in strain; the instrument sensitivity is approximately 5 µm in translation and 0.05° in rotation.

3DXRD↗

Dispersion-Engineered Deep Sub-Wavelength Plasmonic Metasurfaces for Broadband Seira Applications

Surface enhanced infrared absorption (SEIRA) spectroscopy is a powerful tool in which plasmonically enhanced electromagnetic fields provide high-sensitivity molecular detection. Most SEIRA platforms operate at a single resonant frequency, which must be tuned to match that of the target molecule, and commonly rely on time-consuming lithographic techniques. This study presents a high-throughput and cost-effective plasmonic metasurface for broadband, tunable, and strong infrared signal enhancement. The platform is built upon the principle of dispersion-engineered plasmonic Fabry–Pérot (FP) nanocavity arrays. It offers 1) tight squeezing of infrared (IR) photons into deep sub-wavelength nano-volumes and 2) spectrally tunable near-field enhancements of up to ≈10 6 , two to three orders of magnitude higher than most optical metasurface systems. By coupling multilayer nano-thin film deposition and nanoskiving fabrication techniques, the dispersive FP metasurfaces can be rapidly and reproducibly constructed in a scalable and lithography-free manner. Using IR spectroscopy, the selective and sensitive label-free detection of a molecular monolayer is achieved at a range of frequencies. An enhancement factor of nearly 10 5 is measured at the carbonyl (C = O) vibrational marker band of the molecule. The confluence of high field enhancement, broadband plasmonic response, and facile fabrication makes this metasurface a promising platform for SEIRA spectroscopy.

36 MATERIALS SCIENCE↗

A new generation of direct X-ray detectors for medical and synchrotron imaging applications

Abstract Large-area X-ray imaging is one of the most widely used imaging modalities that spans several scientific and technological fields. Currently, the direct X-ray conversion materials that are being commercially used for large-area (> 8 cm × 4 cm without tiling) flat panel applications, such as amorphous selenium (a-Se), have usable sensitivities of up to only 30 keV. Although there have been many promising candidates (such as polycrystalline HgI 2 and CdTe), none of the semiconductors were able to assuage the requirement for high energy (> 40 keV) large-area X-ray imaging applications due to inadequate cost, manufacturability, and long-term performance metrics. In this study, we successfully demonstrate the potential of the hybrid Methylammonium lead iodide (MAPbI 3 ) perovskite-based semiconductor detectors in satisfying all the requirements for its successful commercialization in synchrotron and medical imaging. This new generation of hybrid detectors demonstrates low dark current under electric fields needed for high sensitivity X-ray imaging applications. The detectors have a linear response to X-ray energy and applied bias, no polarization effects at a moderate bias, and signal stability over long usage durations. Also, these detectors have demonstrated a stable detection response under BNL’s National Synchrotron Light Source II (NSLS-II) 70 keV monochromatic synchrotron beamline.

47 OTHER INSTRUMENTATION↗

Synthesis of nanodiamonds encapsulated by zeolitic imidazole framework-8 for quantum sensing applications

Nitrogen vacancy (NV)-containing nanodiamonds are widely used in quantum sensing applications due to their high sensitivity to magnetic fields, relatively low cost, and ability to be initialized, manipulated, and read out at room temperature. Quantum sensing techniques such as optically detected magnetic resonance (ODMR) and spin relaxometry have exploited the sensitivity of the NV nanodiamonds to magnetic fields to detect a range of analytes, such as pH, metal ions, and biomolecules. However, diversifying the sensing targets accessible by NV diamond quantum sensors typically requires careful engineering of the diamond surface chemistry with stimuli-responsive functional groups. Here, a simple protocol for coating NV nanodiamonds with the zeolitic imidazole framework 8 (ZIF-8), a widely used metal-organic framework, is presented. ZIF-8 is a highly porous material that has been used as a selective sensor for gasses, metal ions, and other analytes. The material is well-characterized by x-ray diffraction, transmission electron microscopy, scanning electron microscopy, x-ray photoelectron spectroscopy, and luminescence spectroscopy. Encapsulation of NV nanodiamonds with a porous scaffold such as ZIF-8 provides a promising method for improving the selectivity for the quantum sensing of various analytes. Importantly, the ZIF-8 coating does not impact the luminescence properties of the NV diamond, which is a key readout in ODMR and spin relaxometry sensing approaches. Indeed, the ODMR spectra with and without the ZIF-8 shell is nearly identical. Moreover, the ZIF-8 coating increases the longitudinal spin relaxation time of the NV nanodiamond by a factor of 4 relative to aggregated diamond, a desirable outcome for spin relaxation-based quantum sensing. Metal-organic framework composites with nanodiamonds thus are an exciting strategy for enhancing NV nanodiamond performance in applications such as quantum sensing and quantum-enhanced nuclear magnetic resonance spectroscopy.

nitrogen vacancy nanodiamond↗