Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “high current densities”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Development of a high current density, high temperature superconducting cable for pulsed magnets

Abstract A low AC loss Rare Earth Barium Copper Oxide (REBCO) cable, based on the VIPER cable technology has been developed by Commonwealth Fusion Systems for use in high field, REBCO based tokamaks. The new cable is composed of partitioned and transposed copper ‘petals’ shaped to fit together in a circular pattern with each petal containing a REBCO tape stack and insulated from each other to reduce AC losses. A stainless steel jacket adds mechanical robustness—also serving as a vessel for solder impregnation—while a tube runs through the middle for cooling purposes. Additionally, fiber optic sensors are placed under the tape stacks for quench detection. To qualify this design, a series of experiments were conducted as part of the SPARC tokamak Central Solenoid Model Coil program—to retire the risks associated with full scale, fast ramping, high flux HTS Central Solenoid (CS) and Poloidal Field (PF) coils for tokamak fusion power plants and net energy demonstrators. These risk study and risk reduction experiments include (1) AC loss measurement and model validation in the range of ~5 T/s, (2) an IxB electromagnetic loading of over 850 kN/m at the cable level and up to 300 kN/m at the stack level, (3) a transverse compression resilience of over 350 MPa, (4) manufacturability at tokamak relevant speeds and scales, (5) cable to cable joint performance, (6) fiber optic based quench detection speed, accuracy, and feasibility, and (7) overall winding pack integration and magnet assembly. The result is a cable technology, now referred to as PIT VIPER, with AC losses that measure fifteen times lower (at ~5 T/s) than its predecessor technology; a 2% or lower degradation of critical current (Ic) at high IxB electromagnetic loads; no detectable Ic degradation up to 570 MPa of transverse compression on the cable unit cell; end to end magnet manufacturing, consistently producing Ic values within 7% of the model prediction; cable to cable joint resistances at 20 K on the order of ~15 nΩ; and fast, functional quench detection capabilities that do not involve voltage taps. This cable technology will be tested comprehensively in a Central Solenoid Model Coil to prove its readiness for compact, high field tokamak operation.

Sanabria, Charlie (ORCID:0000000150175309)↗

Growth and characterization of high current density, high-speed InAs/AlSb resonant tunneling diodes

InAs/AlSb double-barrier resonant tunneling diodes with peak current densities up to 370,000 A/sq cm and high peak-to-valley current ratios of 3.2 at room temperature have been fabricated. The peak current density is well-explained by a stationary-state transport model with the two-band envelope function approximation. The valley current density predicted by this model is less than the experimental value by a factor that is typical of the discrepancy found in other double-barrier structures. It is concluded that threading dislocations are largely inactive in the resonant tunneling process.

Soderstrom, J. R.↗

Can High Current Density HTS Magnets be Quench Protected Using Methods Used to Protect High Current Density LTS Magnets?

In the 1970s the Lawrence Berkeley Laboratory (LBL) was testing high current density magnets where the EJ 2 limit was up to two orders of magnitude higher than the quench protection methods of the period would permit at the time. LBL was designing a high current density (J) thin solenoid with a large volume and stored energy (E). The accepted EJ 2 limit at the time was ~10 23 J A 2 m -4 . In order to exceed the EJ 2 limit by two orders of magnitude, one had to greatly increase the quench protection voltages (V) and magnet current (I). In 1977, LBL tested four quench protection methods on a 2-meter diameter high current density solenoid with a stored energy of 2 MJ. Three of these quench protection methods worked well, but the fourth didn't appear to work. These methods will be discussed as to whether they can be applied to HTS or MgB 2 high current density magnets.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

High-Current Density Durability of Pt/C and PtCo/C Catalysts at Similar Particle Sizes in PEMFCs

The durability of carbon supported PtCo-alloy based nanoparticle catalysts play a key role in the longevity of proton-exchange membrane fuel cells (PEMFC) in electric vehicle applications. To improve its durability, it is important to understand and mitigate the various factors that cause PtCo-based cathode catalyst layers (CCL) to lose performance over time. These factors include i) electrochemical surface area (ECSA) loss, ii) specific activity loss, iii) H + /O 2 -transport changes and iv) Co 2+ contamination effects. We use a catalyst-specific accelerated stress test (AST) voltage cycling protocol to compare the durability of Pt and PtCo catalysts at similar average nanoparticle size and distribution. Our studies indicate that while Pt and PtCo nanoparticle catalysts suffer from similar magnitudes of electrochemical surface area (ECSA) losses, PtCo catalyst shows a significantly larger cell voltage loss at high current densities upon durability testing. The distinctive factor causing the large cell voltage loss of PtCo catalyst appears to be the secondary effects of the leached Co 2+ cations that contaminate the electrode ionomer. A 1D performance model has been used to quantify the cell voltage losses arising from various factors causing degradation of the membrane electrode assembly (MEA).

08 HYDROGEN↗

Thin Cation-Exchange Layers Enable High-Current-Density Bipolar Membrane Electrolyzers via Improved Water Transport

With suitable water dissociation (WD) catalysts, bipolar membranes (BPMs) can efficiently dissociate water into H + and OH – at the junction between anion- and cation-exchange layers (AEL and CEL, respectively). First, however, water must be transported through the AEL or CEL and thus against the outward flow of hydrated H + and OH – . This is a challenge intrinsic to the BPM architecture and limits operation to current densities typically less than ~0.5 A·cm –2 . Here we explore how water transport affects durability and performance in reference alkaline and acidic membrane electrolyzers, and we use the insight gained to design BPMs with improved water transport. We demonstrate a thin-CEL BPM (2-μm Nafion CEL|~200 nm TiO 2 |~200 nm NiO + ionomer|50 μm Sustainion AEL) which maintains a pH difference of ~14 units between the anode and cathode for current densities of up to 3.4 A·cm –2 with a total water electrolysis voltage of ~4 V and an estimated WD overpotential of ~1.5 V. Finally, such high-current-density operation is crucial for key emerging BPM applications, including in water and carbon-dioxide electrolyzers and in (regenerative) fuel cells.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Comparison between the magnetic and transport critical current densities in high critical current density melt-textured yttrium barium copper-oxide

Using a recently developed pulsed critical current density (Jc) measuring system, the Jc of the high-Jc melt-textured YBa2Cu3O(7-delta) (Y123) bulk samples has been determined. I-V curves with a voltage resolution of 0.5 microV were obtained, and transport Jc's along the a-b plane as high as 7.2 x 10 to the 4th A/sq cm were extracted. These results are comparable to the values obtained magnetically. On the other hand, transport Jc along the c axis were found to be two orders of magnitude smaller, even though the magnetic Jc along the c axis is only about five times smaller than Jc along the a-b plane. It is suggested that for the high-temperature superconducting materials which are highly anisotropic, caution should be taken when using the nontransport magnetic methods to determine Jc.

Gao, L.↗

Periodic Porous 3D Electrodes Mitigate Gas Bubble Traffic during Alkaline Water Electrolysis at High Current Densities

We report alkaline water electrolysis at high current densities is plagued by gas bubble generation and trapping in stochastic porous electrodes (e.g., Ni foams), which causes a significant reduction in the number of electrolyte accessible catalyst active sites. Here, 3D printed Ni (3DPNi) electrodes with highly controlled, periodic structures are reported that suppress gas bubble coalescence, jamming, and trapping and, hence, result in rapid bubble release. The 3DPNi electrodes decorated with carbon-doped NiO achieve a high current density of 1000 mA cm -2 in 1.0 m KOH electrolyte at hydrogen evolution reaction and oxygen evolution reaction overpotentials of 245 and 425 mV, respectively. This work demonstrates a new approach to the deterministic design of 3D electrodes to facilitate rapid bubble transport and release to enhance the total electrode catalytic activity at commercially relevant current densities.

08 HYDROGEN↗

A Hydrogen Iron Flow Battery with High Current Density and Long Cyclability Enabled Through Circular Water Management

The hydrogen‐iron (HyFe) flow cell has great potential for long‐duration energy storage by capitalizing on the advantages of both electrolyzers and flow batteries. However, its operation at high current density (high power) and over continuous cycling testing has yet to be demonstrated. In this article, we discuss our design and demonstration of a water‐management strategy that supports high current and long‐cycling performance of a HyFe flow cell. Water molecules associated with the movement of protons from the iron electrode to the hydrogen electrode are sufficient to hydrate the membrane and electrode at a low current density of 100 mA cm −2 during the charge process. At higher charge current density, more aggressive measures must be taken to counter back‐diffusion driven by the acid concentration gradient between the iron and hydrogen electrodes. Our water‐management approach is based on water vapor feeding in the hydrogen electrode and water evaporation in the iron electrode, thus enabling high current density operation of 300 mA cm −2 .

Yan, Litao↗

A Hydrogen Iron Flow Battery with High Current Density and Long Cyclability Enabled Through Circular Water Management

The hydrogen‐iron (HyFe) flow cell has great potential for long‐duration energy storage by capitalizing on the advantages of both electrolyzers and flow batteries. However, its operation at high current density (high power) and over continuous cycling testing has yet to be demonstrated. In this paper, we discuss our design and demonstration of a water management strategy that supports high current and long cycling performance of a HyFe flow cell. Water molecules associated with the movement of protons from the iron electrode to the hydrogen electrode are sufficient to hydrate the membrane and electrode at a low current density of 100 mA cm −2 during the charge process. At higher charge current density, more aggressive measures must be taken to counter back‐diffusion driven by the acid concentration gradient between the iron and hydrogen electrodes. Our water management approach is based on water vapor feeding in the hydrogen electrode, and water evaporation in the iron electrode, thus enabling the high current density operation of 300 mA cm −2 .

25 ENERGY STORAGE↗

Rapid synthesis of phase-engineered tungsten carbide electrocatalysts via flash joule heating for high-current-density hydrogen evolution

Fabricating durable and high-performance electrocatalysts operating at high current densities for industrial acidic hydrogen evolution remains a daunting challenge. Tailoring the phase composition of electrocatalysts is a promising strategy to harness synergistic effects and improve charge transfer, thereby optimizing their performance. Here, this work presents a fast, green method based on flash joule heating (FJH) to synthesize phase-engineered tungsten carbide electrocatalysts for the acidic hydrogen evolution reaction (HER) at high current densities. Tungsten carbide electrodes with varying FJH treatment durations (3, 10, 30, and 60 s) are fabricated to fine-tune the mixture of tungsten monocarbide (WC) and tungsten semicarbide (W 2 C) phases. Results show that samples with a 30-s treatment (TC-3) exhibit an optimal balance between these phases, leading to a low overpotential of 180.97 and 387 mV at current densities of 10 mA/cm 2 and 4 A/cm 2 , respectively. TC-3 exhibits significantly lower charge transfer resistance compared to the other electrocatalysts, which can be attributed to its optimal phase ratio. Notably, the TC-3 electrocatalyst remains stable for over 9 days at 4 A/cm 2 due to their controlled phases and excellent corrosion-resistant properties. This work highlights a new method to fabricate cost-effective, high-performance tungsten carbide electrocatalysts with well-controlled phase compositions.

Acidic hydrogen evolution reaction↗

High Current Density Cables for Simpler HTS Magnets in Fusion Energy Systems

High current density cables are needed for the engineering design of potentially low cost, simpler geometry high temperature superconducting (HTS) magnets in the promising magnetic configurations as a fusion pilot plant (FPP) option. Significant technology maturation efforts are underway by privately funded startups with the goal to demonstrate mature HTS magnet technology. Test results, however, indicate critical engineering issues remain to be addressed to meet performance goals, and demonstrate HTS coil operation repeatability and reliability. To this end, exploring and enabling multiple viable conductor and cable options is vital. Partnering with a private fusion startup and manufacturers of superconducting strands and cables, Princeton Plasma Physics Laboratory (PPPL) is exploring and seeking to de-risk the aggressive high field approach presently targeted by others. Our main objective is to develop, test and calibrate novel high current density cables for a broad deployment of affordable and reliable coils using Bi-2212 conductors. If successful, such a project will provide technical feasibility for promising FPP configurations including spherical tokamaks (ST) and compact stellarators. Here, we aim at the state-of-the-art Bi-2212 cable technologies toward a current density of 100 A/mm 2 at 16 T and 4.2 K–10 K operation for low cost, simpler geometry toroidal field (TF) coils for compact stellarators developed by fusion startup companies on a timeline consistent with the FPP initiatives and beyond.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Rotation of electrothermal-instability-driven overheating structure due to helically oriented surface magnetic field on a high-current-density aluminum rod

Experiments on the 1-MA, 100-ns-rise-time Mykonos Facility demonstrate rotation of electrothermal instability (ETI)-driven overheating structure on 1.00-mm-diameter, 10-nm-surface roughness, 99.999%-pure aluminum rods, which are pulsed with helically polarized surface magnetic field. Rods are machined to include pairs of 10-micron-scale quasi-hemispherical voids or “engineered defects (ED)” which provide the dominant current density perturbation from which ETI grows most rapidly. Experiments include an axial magnetic field component through the addition of a helically wound return-current electrode or “helical return can (HRC).” For a given HRC design, azimuthal field (B ɵ ) and axial field (B z ) components rise at a prescribed and fixed ratio, driving an increasing magnetic field of constant polarization at the rod's surface; most experiments generated surface magnetic field at a 15-degree field polarization angle (from horizontal) defined as ɸ B = arctan(B z /B ɵ ). ETI-driven emission patterns from individual ED are observed to rotate along ɸ B , while emission patterns from dielectric-coated ED pairs are shown to elongate and preferentially merge along ɸ B , in qualitative agreement with 3D-magnetohydrodynamic simulations. These data strongly support that for a randomized distribution of current density perturbations on a high-current density conductor, nearby perturbations will favorably merge about ɸ B , with the degree of merging increasing with current. Such observations offer fundamental new understanding of the seeding mechanisms of the helical magneto-Rayleigh Taylor (MRT) instabilities observed from axially magnetized magnetically driven imploding liners.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Ultra-stable trimetallic phosphide heterostructure with regulated electronic structure for overall water splitting at high current densities

Developing ultra-stable electrocatalysts for highly efficient overall water splitting at high current density (HCD) is critical for renewable hydrogen/oxygen production in the industry. However, the most active electrocatalysts for large current-driven water splitting are seriously handicapped by insufficient electrical contact kinetics due to the intensive bubble overflow. Herein, we demonstrate the ultra-stable trimetallic phosphides of NiFeP/NiCoP catalysts on a hydrophilic Ni foam skeleton via a corrosion-hydrothermal-phosphating strategy. The optimized NiFeP/NiCoP catalyst stabilizes for 600 h at -1 A cm -2 for hydrogen evolution reaction (HER) and oxygen evolution reaction (OER) in alkaline solution, and it only needs low overpotentials of 237 and 314 mV to drive HER and OER at 1 A cm -2 , respectively. As expected, the optimized NiFeP/NiCoP electrode maintains 1000 h at 0.5 A cm -2 for water splitting, ranking among the top performers among reported catalysts. Such excellent performance could be attributed to the fast electron transfer for electrochemical reactions, the electron-deficient Fe/Ni sites contribute to forming robust metal oxyhydroxide during OER, and electron-rich Co sites facilitate H adsorption during HER. In conclusion, the findings present a highly promising candidate for ultra-stable non-noble metal electrocatalysts, offering a viable option for hydrogen/oxygen supply for fuel cells and metal-air batteries.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Editors’ Choice—Ionomer Side Chain Length and Equivalent Weight Impact on High Current Density Transport Resistances in PEMFC Cathodes

Cell voltage at high current densities (HCD) of an operating proton-exchange membrane fuel cell (PEMFC) suffers from losses due to the local-O 2 and bulk-H + transport resistances in the cathode catalyst layer (CCL). Particularly, the interaction of perfluorosulfonic acid (PFSA) ionomer with the carbon supported platinum catalyst plays a critical role in controlling reactant transport to the active site. In this study, we perform a systematic analysis of the side chain length and equivalent weight (EW) of PFSA ionomers on the CCL transport resistances. Ex situ measurements were carried out to quantify the ionomer characteristics such as the molecular weight, proton conductivity and water uptake. Nanomorphology of ionomers cast as 60–120 nm thin-films is characterized using grazing-incidence X-ray scattering. In situ fuel cell electrochemical diagnostic measurements were carried out to quantify the reactant (H + /O 2 ) transport properties of the CCL. Ionomer EW was found to play a major role with decreasing EW yielding higher proton conductivity and water uptake that led to lower bulk-H + and local-O 2 transport resistances in the CCL. Finally, a 1D-semi-empirical performance model has been developed to quantify the impact of ionomer EW on cell voltage loss factors.

08 HYDROGEN↗

Operando Topography and Mechanical Property Mapping of CO 2 Reduction Gas-Diffusion Electrodes Operating at High Current Densities

Electrochemical atomic force microscopy (EC-AFM) enables measurement of electrode topography and mechanical properties during electrochemical reactions. However, for aqueous-based reactions that make gas products, such as CO 2 reduction and water splitting into CO/H 2 , current densities below 1 mA cm −2 have been necessary to prevent formation of bubbles at the electrode; such bubbles can stick to the AFM probe and prevent further AFM imaging. Here, we demonstrate a novel cell design with a gas-diffusion electrode (GDE) to exhaust the gas products, thereby enabling high current density EC-AFM measurements at 1, 10, and 100 mA cm −2 that are not disturbed by bubble formation at the electrode surface. These experiments revealed a stable morphological structure of Cu catalysts deposited on GDEs during high current density operation. Systematic spatially resolved maps of deformation and adhesion showed no signs of a gas-liquid interface between catalyst particles of the GDE.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Optically Excited Lasing in a Cavity‐Based, High‐Current‐Density Quantum Dot Electroluminescent Device

Abstract Laser diodes based on solution‐processable materials can benefit numerous technologies including integrated electronics and photonics, telecommunications, and medical diagnostics. An attractive system for implementing these devices is colloidal semiconductor quantum dots (QDs). The progress towards a QD laser diode has been hampered by rapid nonradiative Auger decay of optical‐gain‐active multicarrier states, fast device degradation at high current densities required for laser action, and unfavorable competition between optical gain and optical losses in a multicomponent device stack. Here we resolve some of these challenges and demonstrate optically excited lasing from fully functional high‐current density electroluminescent (EL) devices with an integrated optical resonator. This advance has become possible due to excellent optical gain properties of continuously graded QDs and a refined device architecture, which allows for highly efficient light amplification in a thin, EL‐active QD layer.

36 MATERIALS SCIENCE↗

Can a Coating Mitigate Molten Na Dendrite Growth in NaSICON Under High Current Density?

Alkali metals are among the most desirable negative electrodes for long duration energy storage due to their extremely high capacities. Currently, only high-temperature (>250 °C) batteries have successfully used alkali electrodes in commercial applications, due to limitations imposed by solid electrolytes, such as low conductivity at moderate temperatures and susceptibility to dendrites. Toward enabling the next generation of grid-scale, long duration batteries, we aim to develop molten sodium (Na) systems that operate with commercially attractive performance metrics including high current density (>100 mA cm –2 ), low temperature (<200 °C), and long discharge times (>12 h). In this work, we focus on the performance of NaSICON solid electrolytes in sodium symmetric cells at 110 °C. Specifically, we use a tin (Sn) coating on NaSICON to reduce interfacial resistance by a factor of 10, enabling molten Na symmetric cell operation with “discharge” durations up to 23 h at 100 mA cm –2 and 110 °C. Unidirectional galvanostatic testing shows a 70% overpotential reduction, and electrochemical impedance spectroscopy (EIS) highlights the reduction in interfacial resistance due to the Sn coating. Detailed scanning electron microscopy (SEM) and energy-dispersive spectroscopy (EDS) show that Sn-coated NaSICON enables current densities of up to 500 mA cm –2 at 110 °C by suppressing dendrite formation at the plating interface (Mode I). In conclusion, this analysis also provides a mechanistic understanding of dendrite formation at current densities up to 1000 mA cm –2 , highlighting the importance of effective coatings that will enable advanced battery technologies for long-term energy storage.

25 ENERGY STORAGE↗