A radiation tolerant clock generator for the CMS endcap timing layer readout chip

Here, we present the test results of a low jitter Phase Locked Loop (PLL) prototype chip for the CMS Endcap Timing Layer readout chip (ETROC). This chip is based on the improved version of a clock synthesis circuit named ljCDR from the Low Power Gigabit Transceiver (lpGBT) project. The ljCDR is tested in its PLL mode. An automatic frequency calibration (AFC) block with the Triple Modular Redundancy (TMR) register is developed for the LC-oscillator calibration. The chip was manufactured in a 65 nm CMOS process with 10 metal layers. The chip has been extensively tested, including Total Ionizing Dose (TID) testing up to 300 Mrad and Single Event Upset (SEU) testing with heavy ions possessing a Linear Energy Transfer (LET) from 1.3 to 62.5 MeV × cm 2 /mg.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

The ETROC2 as the Final Version for CMS Endcap Timing Layer (ETL) Upgrade

The ETROC (Endcap Timing Readout Chip) is being developed for the LGAD-based CMS Endcap Timing Layer (ETL) at HL-LHC. The ETL on each side of the interaction region will be instrumented with a two-disk system of MIP-sensitive LGAD (Low Gain Avalanche Diodes) silicon devices, read out by ETROCs for precision timing measurement with down to ~30 ps timing resolution per track. The ETROC is designed to handle a 16 x 16 pixel cell matrix, with each pixel being 1.3 mm x 1.3 mm to match the LGAD sensor pixel size. The front-end design for preamplifier and discriminator has been specifically optimized for the reduced LGAD signals, with enough flexibilities to meet the ETL specific needs for time resolution, power budget and radiation profile. The ETROC chip is implemented in a commercial 65nm CMOS process. Each channel consists of a preamplifier, a discriminator, a TDC used for TOA (Time Of Arrival) and TOT (Time Over Threshold) measurements, and a memory for data storage and readout. An in-pixel auto threshold calibration is included, along with a self-testing pattern generator. The TOT is used for time-walk correction of the TOA measurement. The detailed hit information (TOA and TOT) from each cell will be read out from a local circular buffer after each Level-1 Accept (about 1 MHz). In addition, a charge injection circuit is implemented to allow for testing and calibration. For more detailed monitoring of the signal pulses, waveform sampling circuits are included for one pixel. The clock distribution is based on a 16x16 H-tree design with a shielding structure to alleviate potential interference. The global peripheral circuits include a PLL, a phase shifter, an I2C slave controller, a fast control block, a global readout, and a data driver along with an efuse and temperature sensor. The ETROC builds event data frames for each L1A selected event and is also capable of providing L1 trigger information for user-defined delayed hits. The main design challenge is how to extract precision timing information from the small LGAD signals in the presence of high irradiation fluence, while keeping the power consumption and digital activity low. The ETL design goal for the time resolution of 50 ps per hit is required to achieve a 35 ps arrival time measurement for a MIP particle, which has its track registered in two ETL disk layers. The LGAD contribution is known to be about 30 ps, this means that the jitter from the ETROC has to be kept below 40 ps. The ETROC2 is the first full size full functionality prototype design fully compatible with the final chip specifications for CMS ETL and now becomes the final version. The ETROC2 chips have been extensively tested. We will present here new testing results including the bump bonding yield improvement study, the time walk correction (TWC) generality study with one pixel TWC applying to all pixels, the final SEU testing using both heavy ion and proton beam, more beam test studies including different sensors, and readiness for the ETROC2 production for CMS ETL upgrade.

Liu, Tiehui [Fermilab] (ORCID:0009000765225605)↗

ETROC2 as the Final Version for CMS MTD Endcap Timing Layer (ETL) Upgrade

The ETROC2 is the first full-size full-functionality prototype design fully compatible with the final chip specifications for CMS ETL. The ETROC2 chips have been extensively tested and the results have been presented at IEEE NSS MIC RTSD 2024. We will present here new results including the bump bonding yield improvement study, the time walk correction (TWC) generality study with single pixel TWC applied to all pixels, the final SEU testing results using both heavy ion and proton beam, more beam test studies including different sensors and irradiated sensors, and readiness for the ETROC2 production for CMS ETL upgrade.

Liu, Tie Hui [Fermilab] (ORCID:0009000765225605)↗

The Single Event Error (SEE) test and analysis of the CMS Endcap Timing Layer readout chip

The ETROC2, the first full size and full functionality prototype chip for the CMS Endcap Timing Layer readout, is strategically designed to meet the SEE immunity requirements of detector operation with the low power constraint. The triplicated periphery and pixel I2C configuration registers are designed with self-correction feature. The pixel readout control is centralized in the global readout and fully triplicated. The pixel readout is not triplicated, instead protected with power-efficient one-bit correction Hamming code. The TMR protection of the on-pixel threshold calibration can be turned off allowing the detection of the beam spot during the beam test by checking the bit-flips of the internal memory cells. In the initial proton beam test in January 2024, the chip readout process did not hang throughout the tests. The Hamming code correction strategy works because the error corrected TDC data were observed in the data frames. The error-injection simulation is performed to analy ze the small number of bit-flips in the configuration registers. We also performed SEE testing with a heavy ion beam in April and the data analysis is ongoing. The detailed design on the SEE immunity and the testing as well as simulation results will be presented, including follow-up SEE testing results in May and June 2024.

Gong, Datao↗

Model emulation and closure tests for (3+1)D relativistic heavy-ion collisions

In nuclear and particle physics, reconciling sophisticated simulations with experimental data is vital for understanding complex systems like the Quark Gluon Plasma (QGP) generated in heavy ion collisions. However, computational demands pose challenges, motivating using Gaussian Process emulators for efficient parameter extraction via Bayesian calibration. We conduct a comparative analysis of Gaussian Process emulators in heavy-ion physics to identify the most adept emulator for parameter extraction with minimal uncertainty. Furthermore, our study contributes to advancing computational techniques in heavy-ion physics, enhancing our ability to interpret experimental data and understand QGP properties.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Extending deterministic transport capabilities for very-high and ultra-high energy electron beams

Focused Very-High Energy Electron (VHEE, 50–300 MeV) and Ultra-High Energy Electron (UHEE, > 300 MeV) beams can accurately target both large and deeply seated human tumors with high sparing properties, while avoiding the spatial requirements and cost of proton and heavy ion facilities. Advanced testing phases are underway at the CLEAR facilities at CERN (Switzerland), NLCTA at Stanford (USA), and SPARC at INFN (Italy), aiming to accelerate the transition to clinical application. Currently, Monte Carlo (MC) transport is the sole paradigm supporting preclinical trials and imminent clinical deployment. In this paper, we propose an alternative: the first extension of the nuclear-reactor deterministic chain Njoy-Dragon for VHEE and UHEE applications. We have extended the Boltzmann-Fokker-Planck (BFP) multigroup formalism and validated it using standard radio-oncology benchmarks, complex assemblies with a wide range of atomic numbers, and comprehensive irradiation of the entire periodic table. We report that 99% of water voxels exhibit a BFP-MC deviation below 2% for electron energies under 1.5 GeV. Additionally, we demonstrate that at least 97% of voxels of bone, lung, adipose tissue, muscle, soft tissue, tumor, steel, and aluminum meet the same criterion between 50 MeV and 1.5 GeV. For water, the thorax, and the breast intra-operative benchmark, typical average BFP-MC deviations of 0.3% and 0.4% were observed at 300 MeV and 1 GeV, respectively. By irradiating the entire periodic table, we observed similar performance between lithium (Z = 3) and cerium (Z = 58). Deficiencies observed between praseodymium (Z = 59) and einsteinium (Z = 99) have been reported, analyzed, and quantified, offering critical insights for the ongoing development of the Evaluated Nuclear Data File mode in NJOY.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

A prototype scintillator real‐time beam monitor for ultra‐high dose rate radiotherapy

Background: FLASH Radiotherapy (RT) is an emergent cancer RT modality where an entire therapeutic dose is delivered at more than 1000 times higher dose rate than conventional RT. For clinical trials to be conducted safely, a precise and fast beam monitor that can generate out-of-tolerance beam interrupts is required. This paper describes the overall concept and provides results from a prototype ultra-fast, scintillator-based beam monitor for both proton and electron beam FLASH applications. Purpose: A FLASH Beam Scintillator Monitor (FBSM) is being developed that employs a novel proprietary scintillator material. The FBSM has capabilities that conventional RT detector technologies are unable to simultaneously provide: (1) large area coverage; (2) a low mass profile; (3) a linear response over a broad dynamic range; (4) radiation hardness; (5) real-time analysis to provide an IEC-compliant fast beam-interrupt signal based on true two-dimensional beam imaging, radiation dosimetry and excellent spatial resolution. Methods: The FBSM uses a proprietary low mass, less than 0.5 mm water equivalent, non-hygroscopic, radiation tolerant scintillator material (designated HM: hybrid material) that is viewed by high frame rate CMOS cameras. Folded optics using mirrors enable a thin monitor profile of ∼10 cm. A field programmable gate array (FPGA) data acquisition system generates real-time analysis on a time scale appropriate to the FLASH RT beam modality: 100–1000 Hz for pulsed electrons and 10–20 kHz for quasi-continuous scanning proton pencil beams. An ion beam monitor served as the initial development platform for this work and was tested in low energy heavy-ion beams ( 86 Kr +26 and protons). A prototype FBSM was fabricated and then tested in various radiation beams that included FLASH level dose per pulse electron beams, and a hospital RT clinic with electron beams. Results: Results presented in this report include image quality, response linearity, radiation hardness, spatial resolution, and real-time data processing. Furthermore, the HM scintillator was found to be highly radiation damage resistant. It exhibited a small 0.025%/kGy signal decrease from a 216 kGy cumulative dose resulting from continuous exposure for 15 min at a FLASH compatible dose rate of 237 Gy/s. Measurements of the signal amplitude versus beam fluence demonstrate linear response of the FBSM at FLASH compatible dose rates of >40 Gy/s. Comparison with commercial Gafchromic film indicates that the FBSM produces a high resolution 2D beam image and can reproduce a nearly identical beam profile, including primary beam tails. The spatial resolution was measured at 35–40 µm. Tests of the firmware beta version show successful operation at 20 000 Hz frame rate or 50 µs/frame, where the real-time analysis of the beam parameters is achieved in less than 1 µs. Conclusions: The FBSM is designed to provide real-time beam profile monitoring over a large active area without significantly degrading the beam quality. A prototype device has been staged in particle beams at currents of single particles up to FLASH level dose rates, using both continuous ion beams and pulsed electron beams. Using a novel scintillator, beam profiling has been demonstrated for currents extending from single particles to 10 nA currents. Radiation damage is minimal and even under FLASH conditions would require ≥50 kGy of accumulated exposure in a single spot to result in a 1% decrease in signal output. Beam imaging is comparable to radiochromic films, and provides immediate images without hours of processing. Real-time data processing, taking less than 50 µs (combined data transfer and analysis times), has been implemented in firmware for 20 kHz frame rates for continuous proton beams.

2D beam imaging↗

A heavy-ion production channel of 149 Tb via 63 Cu bombardment of 89 Y

We report the radionuclide 149 Tb (t 1/2 = 4.1 h) is a potential theranostic isotope which can simultaneously be used for targeted-alpha-particle therapy and positron-emission tomography. Feasibility experiments were performed to test a near-symmetric heavy-ion reaction of 63 Cu bombardment on monoisotopic 89 Y. The indirect reaction was studied to avoid isomer production. Offline gamma spectroscopy was used to quantify thick-target physical yields and experimental results show modest agreement to the fusion-evaporation code PACE4. A near-symmetric fission yield was also observed.

149Tb↗

Coupled Boltzmann transport equations of heavy quarks and quarkonia in quark-gluon plasma

We develop a framework of coupled transport equations for open heavy flavor and quarkonium states, in order to describe their transport inside the quark-gluon plasma. Our framework is capable of studying simultaneously both open and hidden heavy flavor observables in heavy-ion collision experiments and can account for both, uncorrelated and correlated recombination. Our recombination implementation depends on real-time open heavy quark and antiquark distributions. We carry out consistency tests to show how the interplay among open heavy flavor transport, quarkonium dissociation and recombination drives the system to equilibrium. We then apply our framework to study bottomonium production in heavy-ion collisions. We include Υ(1S), Υ(2S), Υ(3S), χb (1P) and χb (2P) in the framework and take feed-down contributions during the hadronic gas stage into account. Cold nuclear matter effects are included by using nuclear parton distribution functions for the initial primordial heavy flavor production. A calibrated 2 + 1 dimensional viscous hydrodynamics is used to describe the bulk QCD medium. We calculate both the nuclear modification factor R AA of all bottomonia states and the azimuthal angular anisotropy coefficient v 2 of the Υ(1S) state and find that our results agree reasonably with experimental measurements. Our calculations indicate that correlated cross-talk recombination is an important production mechanism of bottomonium in current heavy-ion experiments. The importance of correlated recombination can be tested experimentally by measuring the ratio of R AA ( χb (1P)) and R AA (Υ(2S)).

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Bridging nuclear physics across energy scales: from neutrinoless double-beta decay to high-energy heavy-ion collisions

This paper exemplifies how connecting methods at disparate energy scales can illuminate fundamental questions. By demonstrating that nuclear wave function properties governing rare decay processes also influence collective behavior at extreme temperatures and densities, the authors have opened a new pathway for constraining physics beyond the Standard Model. With multiple ton-scale 0νββ experiments under construction, any method reducing NME uncertainties will directly impact our ability to interpret discoveries or constrain neutrino properties. The general principle—that collective phenomena in high-energy collisions can illuminate subtle features of many-body correlations in the colliding nuclei—may find applications across nuclear and particle physics. Furthermore, this intersection of nuclear structure theory, heavy-ion physics, and fundamental symmetry tests represents fertile ground for future discoveries in modern physics.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Investigating the coalescence-inspired sum rule for light nuclei and hypernuclei in heavy-ion collisions

A data-driven idea is presented to test if light nuclei and hypernuclei obey the coalescence-inspired sum rule, i.e., to test if the flow of a light nucleus or hypernucleus is the summed flow of each of its constituents. Here, the mass difference and charge difference among the constituents of light nuclei and hypernuclei are treated appropriately. The idea is applied to the available data for $\sqrt{^sNN}$ = 3 GeV fixed-target Au + Au collisions at the Relativistic Heavy Ion Collider (RHIC), published by the STAR Collaboration. It is found that the sum rule for light nuclei is approximately valid near midrapidity (-0.3 < $\mathcal{y}$ < 0), but there is a clear violation of the sum rule at large rapidity ($\mathcal{y}$ < -0.3). Further, the Jet AA Microscopic Transport Model (JAM), with baryonic mean-field plus nucleon coalescence, generates a similar pattern as obtained from the experimental data. In the present approach, the rapidity dependence of directed flow of the hypernuclei $^3_Λ$⁢H and $^4_Λ$H is predicted in a model-independent way for $\sqrt{^sNN}$ = 3 GeV Au + Au collisions, which will be explored by ongoing and future measurements from STAR.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Testing the impact of electromagnetic fields on the directed flow of constituent quarks in heavy-ion collisions

It has been proposed that strong electromagnetic fields produced in the early stages of heavy-ion collisions can lead to splitting of the rapidity-odd directed flow of positive and negative hadrons. For light hadrons, the interpretation of such measurements is complicated by the low magnitude of directed flow as well as by ambiguities arising from transported quarks. To overcome these complications, we propose measurements using only hadrons carrying produced quarks (u¯, d¯, s s¯ ). Here, we discuss how to identify the kinematics where such hadrons are produced via the coalescence mechanism and therefore their flow is the sum of the flow of their constituent quarks. With this sum rule verified for certain combinations of hadrons, the expected systematic violation of this rule with increasing electric charge can be measured, which could be a consequence of the electromagnetic fields produced in the collisions. Our approach can be tested with the high statistics data from Phase II of the Beam Energy Scan program at the Relativistic Heavy Ion Collider.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Measurement of electrons from open heavy-flavor hadron decays in Au+Au collisions at $ \sqrt{s_{\textrm{NN}}} $ = 200 GeV with the STAR detector

We report a new measurement of the production of electrons from open heavy-flavor hadron decays (HFEs) at mid-rapidity (|y| < 0.7) in Au+Au collisions at $ \sqrt{s_{\textrm{NN}}} $ = 200 GeV. Invariant yields of HFEs are measured for the transverse momentum range of 3.5 < p T < 9 GeV/c in various configurations of the collision geometry. The HFE yields in head-on Au+Au collisions are suppressed by approximately a factor of 2 compared to that in p + p collisions scaled by the average number of binary collisions, indicating strong interactions between heavy quarks and the hot and dense medium created in heavy-ion collisions. Comparison of these results with models provides additional tests of theoretical calculations of heavy quark energy loss in the quark-gluon plasma.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Bridging microscale to macroscale mechanical property measurements and predication of performance limitation for FeCrAl alloys under extreme reactor applications

Microscale mechanical testing has greatly benefited nuclear materials studies in at least two aspects: one is its feasibility to integrate with SEM and TEM microscopes for in situ atomic scale or microscale structural characterization to reveal fundamental details, and the other is its significance in development of accelerator-based ion irradiation technique as a surrogate method to simulate neutron damage. Ion irradiation is able to reach damage creation at a level at least three orders of magnitudes higher than test reactors. However, limited ion penetration depths, which are about a few microns for MeVs heavy ions and 10s microns for MeV light ions, make microscale mechanical tests a necessity. But, there is a great challenge to bridge microscale tests to macroscale tests because a bulk specimen of irradiated nuclear materials for high dose applications cannot be obtained in laboratory.

36 MATERIALS SCIENCE↗

Bridging microscale to macroscale mechanical property measurements and predication of performance limitation for FeCrAl alloys under extreme reactor applications

Microscale mechanical testing has greatly benefited nuclear materials studies in at least two aspects: one is its feasibility to integrate with SEM and TEM microscopes for in situ atomic scale or microscale structural characterization to reveal fundamental details, and the other is its significance in development of accelerator-based ion irradiation technique as a surrogate method to simulate neutron damage. Ion irradiation is able to reach damage creation at a level at least three orders of magnitudes higher than test reactors. However, limited ion penetration depths, which are about a few microns for MeVs heavy ions and 10s microns for MeV light ions, make microscale mechanical tests a necessity. But, there is a great challenge to bridge microscale tests to macroscale tests because a bulk specimen of irradiated nuclear materials for high dose applications cannot be obtained in laboratory.

36 MATERIALS SCIENCE↗