SEARCH · Engineering Papers
Results for “heat transfer coefficients prediction”
Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.
Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.
Modelling the ejection of primary aerosols during the fast pyrolysis of biomass anisotropic particles
A model for the fast pyrolysis of anisotropic biomass particles is presented which considers bubbling dynamics within the liquid intermediate phase (metaplast) and aerosol ejection from this phase. The model employs the population balance equation and the method of moments to estimate the production rate and resultant size distribution of aerosol ejections, incorporating a detailed CRECK reaction mechanism, and considers the effect of anisotropic biomass microstructure on the intraparticle transport of mass and energy. Here, this study investigates the impact of particle size, heating rate (heat transfer coefficient), and lignocellulosic composition on aerosol ejection. The model predicts that, at high heating rates (convective heat transfer coefficient of 359 W/m 2 .K), aerosols can contribute over 20% to the heavy fraction yield in bio-oil for small particles (1 mm diameter, 4 mm length). The model can predict aerosol size distribution and surface area, indicating an average size of 20 μm for bubbles and 5 μm for aerosols during increased bubble production and aerosol ejection rates. These findings are consistent with prior experimental results and provide essential information for future modeling of extra-particle reactions of the aerosols as they progress through the reactor.
Exploring the Feasibility of INCONEL® ALLOY 740H® for Power Plant Headers: Integrating Machine Learning with Computational Fluid Dynamics (CFD)
This keynote presentation explores the behavior of headers—essential components of pipeline systems—using ANSYS simulation software and machine learning techniques. The study aims to predict the thermal and mechanical performance of headers under diverse conditions through both steady-state and transient simulations. We investigate critical parameters such as heat transfer coefficient, fluid velocity, and temperature to optimize header design. Conducted as part of a DOE project led by NCAT in collaboration with UNC Charlotte, this research encompasses multiple key topics. The initial section focuses on the behavior of header systems under steady-state conditions using ANSYS simulation. It underscores the importance of headers in industrial infrastructure, especially in the energy sector, and examines the implications of material selection and flow direction on heat transfer dynamics. Methodologically, we employ Computational Fluid Dynamics (CFD) analysis through ANSYS, detailing the development of models, material properties, geometry specifications, boundary conditions, and meshing strategies. Our simulations explore various operational parameters, including temperature and mass flow rates, crucial for predicting heat transfer coefficients and enhancing header design. Results from the study include parametric investigations into mesh sensitivity, viscosity model evaluations, and the effects of heat transfer locations, all validated against theoretical calculations. We conclude with insights on mesh optimization, the suitability of viscosity models, and recommendations for future research aimed at improving header system efficiency and sustainability in industrial applications.
Prototype Modeling for a Light-Trapping Planar-Cavity Enclosed Particle Solar Receiver
Concentrating solar thermal (CST) systems present a promising avenue for affordable and reliable energy production. Solar receivers are key components that determine the efficiency and longevity of these systems. Particle-based solar receivers have emerged as a compelling alternative to traditional technologies, offering several advantages that address limitations in current CST systems. This is especially true as next-generation CST technologies target applications including electricity generation, thermochemical processes, and industrial process heat, many of which necessitate higher operating temperatures than current commercial molten salt systems. Molten-salt thermal energy storage (TES) systems, commonly used in CSP, face challenges related to freezing and corrosion. Particle-based TES systems, in contrast, do not experience these issues, as particles are stable at high temperatures, exceeding 1000 degrees Celsius. This capability allows for a wider range of applications, including those requiring higher temperatures for industrial processes and efficient electricity generation. A novel innovation in particle-based solar receiver technology is the light-trapping planar cavity receiver (LTPCR) configuration developed by NREL. The LTPCR design consists of small cavity-like structures using opaque planar surfaces, enabling efficient capture and absorption of solar energy. A high incident flux concentration at the cavity aperture is absorbed on the receiver walls, and subsequently transferred to particles on the inside of cavities. The particles flow through the system, forming a fluidized bed inside of the receiver panels, effectively capturing the absorbed solar heat. Air is used as a fluidizing medium in this process to enhance particle heat transfer and mixing. The effectiveness of this design lies in its ability to manage solar flux conditions and ensure high solar-to-thermal receiver efficiency. A 100-kW prototype is currently being tested at the King Saud University in Saudi Arabia to assess the receiver performance. A range of modeling analyses for the optical, thermal, and mechanical effects were conducted to assess the performance of the receiver under on-sun conditions. The solar flux resulting from the KSU heliostat field was modeled using NREL SolTrace software and produced up to 600 kW/m2 at the receiver aperture. The solar flux absorbed on the receiver walls was then used within a computational fluid dynamics (CFD) model to predict wall temperature distributions along with radiation and convection loss. A two-phase CFD model was developed for the fluidized bed of silica sand inside the receiver panels to predict local wall-to-particle heat transfer coefficients, particle temperature distributions, and outlet temperature of the particles. We have also conducted analyses to understand the thermomechanical behavior of these innovative enclosed light-trapping solar receivers optimized for particle heating. We used finite element analysis (FEA) to predict the receiver's performance using temperature distributions obtained from CFD and based on the resulting stress profiles, evaluated creep-fatigue damage with a goal of achieving a 30-year service life. Analysis showed a significant impact of the particle-to-wall heat transfer coefficients (HTCs) on receiver performance, with higher HTCs resulting in reduced stress and increased lifespan. For instance, when using Inconel 740H, increasing the HTC from 800 W/m2 K to 1400 W/m2 K increased the creep life from 4,000 hours to over 100,000 hours. This highlights the importance of understanding and optimizing heat transfer in the design of high-efficiency receivers.
EVALUATION OF OPERATION TEMPERATURES UNDER NATURAL CONVECTION HELIUM FLOW IN A CONFINED CAVITY
The Spallation Neutron Source (SNS) is a high-power accelerator-based pulsed neutron source led by Oak Ridge National Laboratory (ORNL) to achieve high fluxes of neutrons for scientific experiments. Active and passive cooling of the systems and parts forming the SNS have been considered to warrant the safe operation of the facility. The diverse cooling systems make use of conjugated heat transfer mechanisms to provide a stable operation temperature for all components in the machine. Thermal power deposited into stainless-steel piping lines due to particle radiation may reach values of up to 1.2 W/cc in the regions located closer to the center of the lower IRP. These energy deposition levels, in not actively cooled components, such as the transfer-line-outer-vacuum-layer may increase the temperature of the component beyond design requirement limitations. The evaluation of the operation temperatures for the former components relies in the assumption that a low-pressure helium atmosphere provides enough heat removal capacity based on natural convection phenomena. In this work, the evaluation of steady state temperatures in components such as the CMS transfer lines has been evaluated using computational fluid dynamics (CFD), analytical correlations and experimental measurements. The companion experiments were conducted in a closed helium system at pressures varying from 1.1 to 1.5 bar. A copper rod was affixed horizontally between viewing windows and heated at constant power, and measurements were made of both the rod temperature and ambient temperature via a system fiberoptic distributed temperature sensors and RTDs. It was found that the measured heat transfer coefficients agree well with the predictions of Churchill and Chu correlations across the range of cases considered. Additionally, the ambient helium volume above the rod was imaged via background oriented schlieren (BOS), and these data was used to determine the line-averaged density gradients in this region. These gradients were compared to simulation data to validate the predictions of natural convection simulations.
Flow reversal benchmark of a one-sided heated narrow rectangular channel with CATHARE and RELAP5
Flow reversal in narrow coolant channels can be a crucial phenomenon for the safety of research reactors with a downward nominal flow direction. During a loss of forced flow accident, the downward flow stagnates briefly before transitioning into an upward natural circulation flow. The fuel may be damaged if dryout occurs and threshold fuel and/or cladding temperatures are exceeded. A comprehensive study is provided for flow reversal in narrow rectangular channels by examining experimental data and conducting software model analyses. The literature on flow reversal was reviewed, and selected experimental datasets were used to benchmark against CATHARE and RELAP5 models and also compare the code calculations with each other. The experimental data comes from flow reversal tests conducted with a narrow rectangular channel with one-sided heating. The results were compared with experimental data for successful flow reversal tests and predicted dryout power for dryout conditions. Also, the study examined the effects of the pump coastdown period, inlet liquid temperature, system pressure, and localized pressure drops. The experimental results showed that shorter coastdown periods, reduced pressure drops, and lower coolant inlet temperatures increased the dryout power. However, the system pressure did not noticeably affect the results. The simulation results showed that both CATHARE and RELAP5 agreed with experimental data, capturing the trends of the experimental results. Slight differences between each code calculation, as well as the predicted and measured dryout powers, were attributed to experimental uncertainties and the modeling of physical phenomena such as wall nucleation, interfacial heat transfer, drag coefficients, and critical heat flux. Overall, this study provides an understanding of flow reversal and the prediction capabilities of thermal-hydraulics software models. In conclusion, a future study of the flow reversal benchmark of a narrow rectangular channel with two-sided heating may provide additional valuable insights.
Toward Verification of RANS Simulations of the T-Tube Modular Divertor Using Large Eddy Simulations of Impinging Turbulent Plane Jets
Turbulent impinging jets have been proposed to cool high heat flux plasma-facing components such as the solid tungsten target plates of the divertor in long-pulse magnetic fusion energy reactors. In particular, the T-tube modular divertor, originally developed by the ARIES Team, consists of two concentric cylindrical tubes where helium flows through a slot in the inner tube, forming an approximately planar jet that impinges upon and cools the inner surface of the pressure boundary (namely, the outer tube) and the ~15-cm 2 plasma-facing W target. The objective of this work is to demonstrate that large eddy simulations (LESs) accurately simulate the thermal transport in canonical flows that comprise the cooling flow in the T-tube, as well as validate temperatures from LES with experimental measurements in a simplified T-tube geometry. Wall‑resolved LESs, validated by experimental data and verified by direct numerical simulations (DNSs), provide benchmark data for two canonical flows in the T‑tube, namely, planar impinging and wall jets, for Reynolds numbers Re B = 4 × 10 3 to 2 × 10 4 . Our LES results are within 4% to 12% root-mean-square error (RMSE) of surface Nusselt number distributions (Nu) from experiments and DNSs. The validated LES results are then used as the ground truth to evaluate four Reynolds‑averaged Navier-Stokes (RANS) turbulence closures, namely, the k‑ω SST, realizable k‑ε, GEKO, and γ‑SST models. The k‑ω SST model has the best overall performance in terms of heat transfer, giving surface Nu within 12% RMSE of the LES results for high‑ReB impinging jets and reduced overprediction in the wall‑jet region. The GEKO model with default constants has the next best performance, providing slightly better Nu predictions for low ReB impinging jets (versus k-ω SST) but worse overall performance over the full range of ReB studied here. The realizable k‑ε turbulence model significantly overestimates turbulence near the stagnation point, while the γ‑SST model suppresses near‑wall production, biasing the simulations toward simulating laminar surface heat transfer. Simulations of the simplified T‑tube show that LES and RANS simulations with the k‑ω SST model give nearly identical average heat transfer coefficients (HTCs) over the impingement surface. The realizable k‑ε model predicts significantly lower wall temperatures due to overestimation of HTC in the outlet flow.
Structural uncertainty assessment for fire-engulfed objects in crosswind: Establishing credibility for a multiphysics wall-modeled large-eddy simulation paradigm
A structural uncertainty validation study for a large-scale, fire-engulfed, elevated object subjected to crosswind is presented to establish the credibility of a high-fidelity, low-Mach, turbulent reacting flow wall-modeled large-eddy simulation (WMLES) approach that includes multiphysics coupling to participating media radiation and conjugate heat transfer. To establish that WMLES can accurately predict surface quantities including drag and pressure coefficient in the low-Mach crosswind regime, a foundational elevated isothermal cylinder validation case is presented at a similar gap-to-diameter ratio of 0.25, spanning the subcritical to supercritical drag regime (Re 𝐷 = 1.1 × 10 5 and 4.3 × 10 5 , respectively). Here, this study exercised both static and dynamic coefficient LES (Smagorinsky and 𝑘 sgs ) with both local and exchange-based velocity sampling. Results showcase that the drag crisis (or the sudden drop in drag coefficient at increased Re 𝐷 ) is well captured when using an exchange-based dynamic coefficient WMLES methodology, while noting lack of mesh convergence and overall drag and pressure coefficient predictively when using a static coefficient, local velocity sampling WMLES. For the 𝒪(10) m JP-8 liquid pool fire crosswind validation study presented, two experimental crosswind configurations (2 m/s and 9.5 m/s) are showcased for a fire-engulfed mock fuselage roughly 4 m in diameter. Using the best model-form practices identified in the isothermal study, dynamic coefficient 𝑘 sgs exchange-based WMLES fire validation findings demonstrate accurate peak irradiation and skin temperature predictions as a function of crosswind magnitude. Excessive yaw in the low-crosswind fuselage configuration, consistent with experimental findings, captured a significant predicted asymmetry in flame attachment and heat flux toward the downwind cylindrical cap—indicative of axial vortex structures transporting the flame along the upper and lower fuselage leeward surface. All fire mesh resolution simulations captured the experimental finding that as crosswind increased, predicted flame shape and peak irradiation magnitude onto the fuselage transitioned from a windward to a leeward cylinder location due to the migration of the upper- to lower-shear fuel/air mixing layer thereby demonstrating the novelty, significance, and credibility of this high-fidelity WMLES reacting flow framework.
Background-Oriented Schlieren Velocimetry of Helium Coolant Flow in Additively Manufactured Channels
High-pressure helium gas cooling is an attractive solution for thermal management of the fusion blanket first wall, as this coolant is chemically and neutronically inert and separable from hydrogenic species. However, due to the low thermal mass of helium, geometric optimization of these channels is required to provide sufficient cooling at manageable flow rates and pumping burdens. Increasingly, analysis and optimization of these coolant channels rely on computational fluid dynamics (CFD) simulations, and these require relevant experimental data for turbulence model validation. Toward this end, a high-pressure helium gas flow visualization system has been employed to image the flow of helium in flow channels with one-sided heating, mimicking the blanket first wall environment. Flow of helium at 4 MPa pressure and flow rates up to 68 g/s (Reynolds number 57 000) is supplied to rectangular channel test sections, with uniform heating applied to the bottom wall of the channel at heat fluxes varied between roughly 50 and 130 kW/m2. A high-speed camera is used to image index of refraction (IOR) gradients in the fluid via background-oriented schlieren (BOS), and temperature and pressure instrumentation are used to characterize thermal-hydraulic performance of each channel. Cross correlation of time-resolved BOS images is then used to calculate time-averaged 2-D helium velocity fields. Flow in additively manufactured (AM) channels is examined in this manner, including both featureless channels and those containing baffling as a heat transfer enhancement. The flow distribution seen in the featureless case differs significantly from that seen in prior simulations, whereas the flow in the baffled case shows the predicted behavior of flow forced along the heated wall. This augmented flow distribution is seen to increase the heat transfer coefficient in the baffled test section. Here, strategies are discussed for ongoing and future validation of these simulations, with the aim of model deployment for blanket cooling design and optimization.
Heat transfer and visual observation of pool boiling of next-generation low-pressure refrigerant: R1336mzz(Z)
R1336mzz(Z) is a non-flammable and non-toxic hydrofluoroolefin (HFO), which is a potential alternative working fluid for multiple applications such as centrifugal chillers, industrial high temperature heat pumps, and Organic Rankine Cycles. Pool boiling is one of the primary heat transfer modes in shell-and-tube evaporators, and there is limited data for R1336mzz(Z) due to its recent introduction. This study investigated the pool boiling characteristics of R1336mzz(Z) using a closed-loop apparatus. Heat transfer coefficients on a smooth aluminum surface were measured at various heat fluxes with a heating block, and the results were compared to predictions from various correlations. Additionally, a high-speed camera was employed to visualize and analyze the pool boiling behavior of this next-generation low-pressure refrigerant.
Predicting roughness effects in additively manufactured coolant channels with helical enhancements
Additive manufacturing (AM) is a promising technique for fabrication of complex geometries such as those expected to be utilized in the blanket, first wall, and divertor. In the case of cooling, metallic AM may be exploited to embed geometric enhancements (ribs, rifling, etc.) to improve cooling performance. However, due to the roughness of these unfinished internal AM surfaces, prediction of thermal hydraulic performance in such channels is difficult. In this work, we consider a methodology for predicting pressure drop and heat transfer in AM channels containing helical enhancements (e.g. helical ribs, twisted tapes) that allows the incorporation of roughness data through conventional pipe flow correlations. This methodology is tested using experimental friction factor and heat transfer coefficient data from high-pressure helium coolant flow measurements in AM stainless steel tubes fabricated by laser powder bed fusion. Both a featureless AM tube and one containing helical ribs were considered alongside a conventionally manufactured smooth tube. The AM surface roughness is obtained by profilometry and used to predict an equivalent sand-grain roughness, with this equivalent roughness confirmed through AM featureless tube measurements. Under the proposed methodology, this roughness information is incorporated into predictions of friction factor and Nusselt number for the rifled tube. Furthermore, these predictions agree well with experimental data across a large range of Reynolds numbers, encouraging the use of this methodology for thermal hydraulic analysis of similar systems and design of future coolant channel geometries.
A comprehensive numerical investigation on spray models for Direct-Injection Spark-Ignition engines
Gasoline direct-injection spark-ignition (DISI) engines generate a large portion of their unburned hydrocarbon (UHC) and soot emissions during the cold-start phase. A predictive computational fluid dynamics (CFD) modeling framework can be used to understand the physical processes that characterize fuel spray evolution and fuel-film formation at cold start conditions, which can help to reduce engine-out particulate emissions. This study systematically evaluated spray submodels and developed a set of simulation best practices for physical-numerical submodels with the goal of enabling accurate simulations of liquid spray behavior in a DISI engine. Three comprehensive experimental datasets containing free-spray projected liquid volume (PLV), liquid volume fraction (LVF), and near-field X-ray radiography data were used to validate the simulation results and evaluate the spray submodels. Systematic analysis delved into injected parcel distribution, droplet collision, spray breakup, and evaporation via a detailed assessment of the relevant spray submodels. Moreover, the effects of turbulence models and the initial turbulent flow properties on the liquid spray evolution were examined. Based on extensive calibration efforts, a set of simulation best practices for the free spray was developed and validated against the PLV/LVF data. Simulation results indicated that the uniform distribution for parcel initialization, coupled with appropriate droplet collision submodels, provides an improved spray morphology compared to the cluster distribution. The findings also underscored the importance of calibrating the Kelvin-Helmholtz Rayleigh-Taylor (KH-RT) breakup model constants and droplet heat transfer coefficient scaling factor to achieve favorable agreement regarding measured liquid penetration and spray widths. In conclusion, this study marks a substantial stride towards accurately predicting fuel film evolution and soot formation within DISI engine performance.
A Finite Element Method for Compressible and Turbulent Multiphase Flow Instabilities with Heat Transfer
We present a new finite element framework for modeling compressible, turbulent multiphase flows with heat transfer. For two-fluid systems with a free surface, the Volume of Fluid (VOF) method is implemented without the need for interface reconstruction, while turbulence is resolved using a dynamic Vreman large eddy simulation (LES) model. Unlike most two-phase VOF studies, which neglect heat transfer, the present approach incorporates energy transport equations within the VOF formulation to account for heat exchange, an effect particularly important in turbulent flows. Conjugate heat transfer is often challenging in finite volume methods, which require explicit specification of heat fluxes at the solid–fluid interface, limiting accuracy and predictive capability. By contrast, the finite element formulation does not require heat flux inputs, allowing more accurate and robust simulation of heat transfer between solids and fluids. The method is demonstrated through three representative cases. First, a two-fluid instability with a single-mode perturbation is simulated and validated against analytical growth rates. Second, conjugate heat transfer is examined in a high-temperature flow over a cold metal cylinder, with validation performed both quantitatively—via pressure coefficient comparisons with experimental data—and qualitatively using vector field topology. Finally, compressible spray injection and breakup are modeled, demonstrating the ability of the framework to capture interfacial dynamics and atomization under turbulent, high-speed conditions. In the compressible spray injection and breakup case, the results indicate that the finite element formulation achieved higher predictive accuracy and robustness than the finite-volume method. With the same mesh resolution, the FEM reduced the root mean square error (RMSE) and mean absolute percentage error (MAPE) from 6.96 mm and 26.0% (for the FVM) to 4.85 mm and 12.7%, respectively, demonstrating improved accuracy and robustness in capturing interfacial dynamics and heat transfer. The study also introduced vector field topology to visualize and interpret coherent flow structures and instabilities, offering insights beyond conventional scalar-field analyses.
High-temperature seals for supercritical carbon-dioxide (sCO 2 ) turbines (Final Report)
This is the final report for project DE-FE0031924 titled “High-temperature seals for supercritical carbon-dioxide (sCO 2 ) turbines.” The report provides a summary of the entire project efforts from October 2020 through December 2024 including the high-temperature commercial dry gas seal (DGS) tests and thermal modeling of Task 2, as well as the high-temperature, large-diameter seal design and high-temperature tests of large-diameter seals in Task 3. A key outcome of Task 2 was the testing completion of specially instrumented commercial DGS in the GE-SwRI Apollo sCO 2 compressor (27,000 rpm). Test data from the DGS showed elevated temperatures upwards of 350 o F, which are close to the higher operating temperature limit of the DGS. The temperature measurements provide insight into the expected thermal loads on DGS operating in high-speed sCO 2 compressor and provided test data for validation of an in-house thermal model of the compressor/seal. Under Task 2.0, this report also presents the development of a steady-state conjugate heat-transfer model of the DGS operating in the sCO 2 compressor – a first of its kind model for modeling heat transfer of sCO 2 in an actual operating compressor. The findings of the thermal model show a reasonable match between temperature predictions of the model and the measured temperature data, also pointing out the validity of the approach and assumptions made in modeling the flows, heat transfer coefficients and windage modeling in the rig. Under Task 3.0, this report presents the preliminary design of a large-diameter hybrid face seal (14 inch and 26-inch diameter) for field testing in a land-based GE turbine. The preliminary seal design effort presented in this report under project DE-FE0031924 builds on the development and successful laboratory testing for such large diameter hybrid face seal under the prior DE-FE0024007 project. Key aspects of seal fluid analyses with CFD, mechanical design considerations and assembly considerations in a land-based turbine are presented. Finally, under Task 3.0, this report also presents the continued high-temperature testing of the 14-inch diameter hybrid face seal developed previously under the DE-FE0024007 program. Specifically, test data demonstrating successful non-contact seal operation and seal effective leakage of 0.001-inch with seal inlet temperatures above 700 o F are presented in this report. Successful hybrid seal operation in a laboratory environment for a large diameter (14-inch) seal at temperatures above 700 o F is a major technological milestone for this technology.
Pool boiling heat transfer evaluation of next-generation dielectric fluid: Opteon™ 2P50
The growing use of artificial intelligence has led to heavy thermal loads and high heat dissipation rates in data centers. Conventional air-cooled technologies are not able to fulfill these requirements. To overcome these challenges, two-phase immersion cooling (2PIC) has emerged as one of the leading technologies for high power-density chips. 2PIC increases the heat dissipation rate and efficiency of the system while reducing the footprint of the cooling equipment. A fluid with adequate dielectric properties, a suitable normal boiling temperature to maintain chip temperatures, and good material compatibility, is desired for 2PIC system. In this study, the pool boiling heat transfer of a new developmental dielectric fluid, Opteon™ 2P50, was experimentally investigated. The heat transfer coefficients at various heat fluxes (20–150 kW/m 2 ) and the critical heat flux were measured using a smooth aluminum surface. Compared with HFE-7100, Opteon™ 2P50 shows higher heat transfer coefficient (up to 59% higher) and a slightly lower value of critical heat flux (around 5.9% lower). The modified Cooper correlation with the optimized leading constant resulted in reliable prediction accuracy with a 5.3% mean absolute error percentage. Overall, these results indicate that the new dielectric fluid provides similar thermal performance to some legacy fluids.
Optimization of Triply Periodic Minimal Surface Heat Exchanger to Achieve Compactness, High Efficiency, and Low-Pressure Drop
With advancements in additive manufacturing (AM) techniques, high-quality triply periodic minimal surface (TPMS) structures can now be produced. TPMS walled heat exchangers (HX) hold significant potential for industrial applications and are receiving increasing attention. This paper explores the impact of various TPMS design variables on flow and thermal performance to optimize TPMS heat exchangers for compactness, high efficiency, and low pressure drop. The design variables examined include the type of TPMS lattice, unit cell size, wall thickness, aspect ratio, TPMS orientation, and equivalent thickness. The study reveals that the flow and heat transfer performance of TPMS structures are significantly affected by these design variables. For the Gyroid, Diamond, and SplitP lattices, performance is nearly identical when the surface-to-volume ratio is kept constant. The average velocity of the fluid in the TPMS HX should be 0.3 m/s. The corresponding Re is between 300~800. Thin wall thickness, small equivalent thickness, and flat lattice configurations can significantly reduce pressure drop while maintaining the overall heat transfer coefficient. Additionally, the angle between the flow direction and TPMS orientation can increase pressure drop. Three aluminum heat exchangers were successfully printed using an AM machine, and testing results are comparable with theoretical prediction.
Improving the modeling of near-wall interphase heat transfer in porous media models of Pebble Bed Reactors
Here, this work aims to improve capabilities for modeling localized effects in porous media models of Pebble Bed Reactors. The wall-channeling effect is the primary local phenomenon of interest in a PBR, where the presence of the reflector wall disrupts the pebble packing, causing the pebbles near the wall to pack less efficiently and creating large void regions. Accurate modeling of the near-wall region is important as it will affect core bypass flow and temperature predictions. Porous media models are commonly used for design scoping and plant-level simulations of PBRs. Although these models have some capabilities to model the near-wall region, the correlations that are available in porous media codes are often inaccurate when a multi-region model is used to discretize the near-wall region. This work employs a high-to-low analysis to study the accuracy of available interphase heat transfer closures. NekRS, a spectral element computational fluid dynamics code, is used to perform Large Eddy Simulations. These LES simulation results are compared to porous media model results from the Pronghorn porous media code. The friction term of the KTA drag closure is first improved, reducing the error in the prediction of the near-wall velocity from over 50% to less than 5%. This is combined with improvements to the form term from previous works to produce a drag closure that is capable of accurately modeling the wall-channeling effect across a variety of flow conditions. The Nusselt number predictions of several heat transfer correlations are compared to the high-fidelity results where it is found that the KTA heat transfer correlation is capable of accurately predicting the local Nusselt numbers that were determined in the high-fidelity simulation. Comparison of the radial solid temperature profiles, however, reveal discrepancies between NekRS and Pronghorn. It is discovered that the implementation of the interphase heat transfer coefficient that exists in many current porous media codes is not valid when local porosities are modeled. Instead, it is suggested that the interphase heat transfer coefficient should be dependent on the local porosity, the Nusselt number, and the local solid surface-to-volume ratio. Implementation of this change produces improvement in the agreement between the results obtained by NekRS and Pronghorn while using the KTA heat transfer correlation.
Evaluation and development of flow condensation correlations using the data from low GWP refrigerants in an axial micro-fin aluminum tube
To mitigate global warming, the world is transitioning to refrigerants with low global warming potential (GWP). Supporting this shift requires a model that can accurately predict the heat transfer and pressure drop of new refrigerants, crucial for designing efficient heat exchangers. Existing models, however, are largely based on currently deployed refrigerants and primarily developed for unexpanded micro-fin tubes with spiral angles of 6° to 30°. Their applicability to new refrigerants, especially in expanded micro-fin tubes, is uncertain. This study assesses the performance of four well-known condensation models for six emerging refrigerants—R-32, R-454B, R-454C, R-455A, R-1234yf, and R-1234ze(E)—against experimental data. Initially, the Han and Lee (2005) model shows the best prediction accuracy with a mean absolute deviation (MAD) of 22.1 %. To enhance the accuracy of heat transfer models for new refrigerants and geometries with large temperature glides, two approaches are proposed. Here, the first approach applies a simple correction factor, reducing the MAD of the Cavallini et al. (2009) model from 68.2 % to 15.4 %. The second approach uses the variable metric method for minimization, fitting new constants to the data. This optimization results in the Kedzierski and Goncalves (1997) model achieving the highest accuracy, with a MAD of 13.1 %. For pressure drop models, the Cavallini et al. (1997) model is the most accurate with a MAD of 6.4 %, followed by the Haraguchi et al. (1993) model with a MAD of 9.4 %. Due to its simplicity, the Haraguchi et al. (1993) model is a practical option for predicting frictional pressure drop.