Field Performance of R-1234yf Heat Pump Water Heaters

Heat pump water heaters (HPWH) provide a resource for increasing water heating efficiency in U.S. residences. Electric HPWHs have traditionally utilized R-134a as the refrigerant in the vapor-compression cycle; however, this refrigerant is undesirable long-term due to its high global warming potential. For HPWHs, low global warming potential refrigerants such as R-1234yf may offer comparable performance, but the evaluation of these systems has been limited to laboratory settings. This study provides field evaluations of off-the-shelf HPWHs that had their factory R-134a refrigerant replaced with an optimized charge of R-1234yf. The field evaluation consisted of R-1234yf HPWHs at two occupied field sites and two unoccupied, simulated lab homes. At the two residential field sites with occupants, the R-1234yf HPWHs operated issue-free for the 18-month field trial, and the home occupants perceived no change in HPWH performance relative to their prior R-134a HPWHs. At the lab homes, under simulated hot water draws, the average daily operating efficiency of the R-1234yf HPWH was within 2% of the baseline R-134a HPWHs.

42 ENGINEERING↗

Decarbonization Technology Snapshot: Heat Pump Water Heaters

Heat pump water heaters use electricity to move heat from one place to another instead of generating heat directly. In many cases they replace gas-fired water heaters and are significantly more energy efficient, reducing on-site Scope 1 emissions and often resulting in reduced total emissions.

building decarbonization↗

Thermodynamic analysis of a two-stage binary-fluid ejector heat pump water heater

Ejector heat pump water heaters (EHPWHs) could significantly increase the thermal efficiency of domestic water heating and reduce greenhouse gas emissions. This study addresses two major technical barriers to using EHPWHs in domestic water heating—low heating cycle coefficient of performance (COP) and low condensation temperatures—using binary fluid pairs as a working fluid in a two-stage ejector system. A comprehensive, geometry-free model of binary-fluid ejectors was built and validated to predict the entrainment ratios of binary-fluid ejectors. A thermodynamic model of a two-stage binary-fluid ejector EHPWH was built to predict the heating cycle COP of EHPWHs. The performance of the EHPWH was theoretically evaluated using HFE7000 and Novec649 as primary fluids and R600 and R1234ze(Z) as secondary fluids. HFE7000/R600 gave the highest heating cycle COP (i.e., 1.356) in producing domestic hot water at 60.0 °C. An optimum evaporation temperature of the primary fluid was identified for the maximum effective entrainment ratio and effective pressure lift ratio of two-stage ejectors. Here, the effective entrainment ratio of the two-stage ejector dominated the heating cycle COP of the EHPWH. Primary fluids with lower latent heats of evaporation and/or secondary fluids with higher latent heats of evaporation yielded higher heating cycle COPs of EHPWHs.

42 ENGINEERING↗

Performance Evaluation of Drain Water Heat Recovery Exchangers for Heat Pump Water Heaters

Water heating constitutes approximately 18% of energy consumption and is the second largest energy expenses in United States homes. Heat pump water heaters (HPWHs) are energy efficient technologies with lower carbon footprints as compared to conventional water heating technologies, such as gas and electrical resistance heaters. The performance of water-source HPWHs can be improved by recovering heat from blackwater using drain heat recovery heat exchangers. Depending on water draw patterns of single family and multifamily residences, the operation and heat transfer performance of these heat exchangers are highly transient. This paper examines the thermo-hydraulic performance of a drain heat recovery heat exchanger during its transient and steady-state operations. The heat recovery performance of the exchanger was evaluated at different inlet temperatures and flow rates ranging from 9°C to 36°C and 0.03 kg/s to 0.28 kg/s, respectively. The obtained effectiveness varies from 45%–85% depending on the operating conditions. The test facility, steady-state and transient experimental procedures are reported in detail. Further, the effect of operating conditions on the effectiveness is discussed. The experimental approach and results of the study will provide insights into the transient operation of drain recovery heat exchangers as well as, guide sizing for various steady state conditions.

Krishnan, Easwaran↗

A Simulation Study of 120V Heat Pump Water Heaters

A 120 V heat pump water heater (HPWH) is a direct plug-in option to replace gas water heater (WH) without needing expensive electric panel upgrade to 220 V. To enable the smooth transition, the HPWH should provide comparable water heating capacity as the gas WH. WH capacities are rated in the form of first hour rating (FHR). Typical home gas WHs have FHRs > 65 gallon with a 40-gallon water tank. It imposes a major challenge on 120V HPWHs. Most 120V circuits in US can provide 1,800 to 2,400W, not adequate to drive electric resistance heat to boost FHRs. Thus, all the heat needs to come from the heat pump with its top power below 1500 Watts, which is constraint by the installation footprint. This study uses a hardware based, HPWH design model, i.e. the DOE/ORNL Heat Pump Design Model to design a 120V unit with a brazed plate condenser, fin-and-tube evaporator and an adequately sized compressor. To maximize the FHR, multiple strategies were simulated, including use of a mixing valve, overheating the tank temperature to 140F, a new sensing method for quicker response, and an innovative water circulation path. We also simulated 24-hour unform energy factors (UEF) to show the tradeoff between the capacity and operation efficiency. Additionally, we evaluated the impact of insulation thickness on FHR and UEF, to seek further footprint reduction or stretch the tank volume.

Shen, Bo↗

Field Study of 120-volt Heat Pump Water Heaters in the Big Easy

To meet long-term goals for reducing carbon emissions and lessen the impacts of climate change, the U.S. plans to decarbonize its building stock, which includes the replacement of fossil fuel-burning end uses with energy efficient electric alternatives. As part of this strategy, the replacement of fossil fuel water heaters with heat pump water heaters (HPWH) has the potential to avoid substantial carbon emissions. An estimated 10-15 million single-family homes with fossil fuel water heaters do not have the electrical panel capacity to install a 240-volt, 30-amp HPWH. For these homes, a technology recently introduced to the market, the 120-volt plug-in HPWH, can provide energy efficient electrification of water heating without an expensive panel and wiring retrofit. This paper presents the results of an ongoing 120-volt HPWH field study conducted in 17 homes in New Orleans, LA. Key installation scenarios are profiled for retrofitting from gas-fired water heaters to 120-volt HPWHs, accounting for space, air volume, air temperature, condensate drainage, and electrical. Each HPWH had its surrounding air temperature, relative humidity, inlet and outlet water temperature, flow, and energy consumption monitored. Using these data, hot water delivery and energy efficiency performance were analyzed based on home characteristics. Hot water run outs were investigated to understand how hot water usage, inlet water temperature, and surrounding air temperature impact the HPWH’s ability to meet load. From these results, best practices for 120-volt HPWH siting, sizing, and installation were developed. In addition, results are explored further to add insight for electrification policies and product development.

heat pump water heater, 120-volt, Residential buil↗

Peak Reduction Using Mode Adjustment of Heat Pump Water Heaters in a Residential Neighborhood

Building electrification is putting pressure on distribution grid worldwide. Peak reduction is an important concern that can help reduce the growing stress and allow to defer investments in new capacity. Water heaters represent a convenient way of reducing peak because they are less dependent on weather, and their storage volume allows for asynchronous water heating and hot water use. Previous empirical studies investigated the ability of water heaters to reduce peak through the adjustment of the temperature setpoint. However, not all equipment vendors offer this option. This study aims at understanding the feasibility of peak reduction with an alternative configuration available in the market - by adjusting the device mode rather than temperature setpoint. The peak reduction methodology is tested in an occupied 46-townhome neighborhood located in Atlanta, GA. We find that peak shifting is possible with the adjustable mode approach, with the change in the peak load by 30-60%.

demand response↗

Scaling Up: Demonstrating Risk Reduction and Cost Compression for Commercial Heat Pump Water Heaters - CRADA 625 (Abstract)

Commercial heat pump water heater (CHPWH) systems significantly decarbonize the commercial and multifamily sectors by eliminating the reliance on gas-fired water heating. CHPWH systems are also well suited to include load shift controls that enable load-up and shed commands for supporting grid reliability and time-of-use pricing structure. However, they have not had wide adoption due to factors including price, complexity, and perceived risk. Although CHPWHs have been available in the US for decades, they have not made significant market gains in part because the systems have required significant and costly engineering design expertise and proved lackluster performance. Successful widespread market adoption requires a different approach; a shift from the current custom specialized expertise project design and installation to a repeatable approach that requires little specialized knowledge or expertise and can deliver persistent performance. Using this type of holistic systems approach requires effectively integrating four CHPWH system key components: primary air-to-water heat pumps; primary thermal storage tanks, a temperature maintenance system, and a control system which has capabilities to manage the primary heat pump cycles, any back-up, supplemental, or temperature maintenance heating, alarms, and grid connectivity allowing for demand response (DR), and/or load shifting. The project team has developed and will implement a suite of tools to support faster, less expensive, and more reliable field installations of CHPWH technology and with the resulting data used to further improve the tool set. These tools include: (1) A tool for optimizing system size and costs. (2) A tool that predicts annual energy use and overall system efficiency. (3) The Advanced Water Heater Specification (AWHS 8.0) defining the components of a full CHPWH system addressing performance requirements by climate zone. (4) The Qualified Products List: (QPL) of approved products that meet the specifications requirements. (5) Training materials including online on-demand modules, instructor-led training, and virtual interactive video tours of CHPWH installations in multifamily buildings. Demonstration site identification in low-income buildings in underserved communities is currently underway. Preliminarily, the team anticipates having three demonstrations in the Pacific Northwest and three in the Northeast for a total of six sites. After the demonstration sites are finalized, and M&V instrumentation installations are complete, the team will gather performance data and confirm whether the CHPWH systems perform as predicted and use the data to improve the existing tools.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

The Empirical Effect of Fleet Optimization on Synchronization and Rebound Effects in Heat Pump Water Heaters

Demand response is a growing concept in light of the internet of things and an increasing need for grid flexibility. Water heaters are one of the preferred devices for providing demand response for grid services and peak management due to their capability to store energy. The efficient use of water heaters for demand response requires consideration of the associated load effects such as synchronization of device schedules and rebound effect. These effects present a significant challenge. Despite the importance of the mentioned effects for water heater queuing and scheduling, there has been no effort to quantify and empirically validate their impact. This study attempts to address this gap by offering two methods - Ward clustering and Euclidean K-means - to evaluate the extent of synchronization in a fleet of 42 water heaters in Atlanta, GA. Using the aforementioned methods on the measured data, we find evidence of convergence of water heater loads as a result of optimization compared to an idle period and analyzed their impact.

demand response↗

Parametric Studies of Heat Pump Water Heater Using Low GWP Refrigerants

A storage heat pump water heater (HPWH) comprises a vapor compression system and a hot water tank. It can lead to more than 70% energy saving, compared with electric resistance heating. HPWH usually uses a wrapped-tank coil as the water heater. The wrapped coil has a strong interaction with the water tank and impose a new challenge for the engineering design and simulation study. Based on the US DOE/ORNL Heat Pump Design Model (HPDM), i.e., a public-domain, component-based thermal system modelling platform, a segment-to-segment wrapped-tank coil model coupled with a one-dimensional stratified water tank model were developed, which facilitates modeling and design HPWHs having various configurations and components. Additionally, the hardware-based design model was used to evaluate refrigerants having lower global warming potentials to replace R-134a, including R-1234yf, R-1234ze, R-290, R-513A and R-450A, when effects of compressor size, refrigerant charge on 24-hour uniform energy factor (UEF) and first-hour rating (FHR) were investigated.In the drop-in replacements, R-1234ze achieved the best UEF, and R-290 resulted in the lowest UEF. When downsizing the compressor to maximize the UEFs, the UEFs of R-134a, R-290, R1234yf, R-450A and R-513A ascended to the range of 4.4 to 4.53, with R-513A having the highest UEF. The R-1234ze ended up having the lowest UEF of 4.27. Refrigerants having larger volumetric vaporization heat led to higher FHRs if using the fixed-size compressor, that R-290 resulted in the highest FHR.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Experimental results of embedded phase change material capsules for increasing the performance of a wrapped heat pump water heater

Herein, to enhance the capacity of heat pump water heaters (HPWHs), high energy density phase change material (PCM) was used in two experimentally tested HPWH prototypes. Preliminary findings showed that in the PCM, stored thermal potential energy could be effectively converted into sensible heat in the water over a slight temperature difference, with the goal of increasing the capacity of hot water above a desired cut-off temperature. This exchange of energy results in an increased amount of hot water necessary for mixing at the location utilized by the consumer. It was also found that for a wrapped HPWH, there was an average increase of 27.7% in the capacity when 7.6 L of novel PCM filled spherical capsules were added to a 22.7 L tank downstream of the HPWH. In the second design (Beta), PCM capsules were immersed into the tank with a cylindrical geometry, and the UEF was increased by 5.5% over the baseline HPWH test result. As for the Beta design, heat loss was reduced significantly compared to a typical HPWH and the Alpha design. Food-grade PCMs were selected as appropriate. The novel encapsulation design increased the effective conductivity inside the capsule by adding metal fins.

42 ENGINEERING↗

Charge Reduction and Performance Analysis of a Heat Pump Water Heater Using R290 as a Refrigerant—A Field Study

Heat pump water heaters (HPWHs) are a proven technology for water heating that has been commercialized. The adoption of HPWHs for domestic and commercial water heating is growing rapidly because of their superior performance compared with alternative water heating methods. Whereas most existing systems use R-134a as a working refrigerant, R290 has gained major attention owing to its superior thermodynamic properties. The goal of the current study is to assess the performance of residential HPWH with R290 as a direct refrigerant replacement for R134a. Two units of a 50 gal HPWH were used in this experimental study. A baseline unit contained R134a refrigerant, and a prototype unit contained R290 refrigerant. The prototype unit was developed through the modification of a commercially available HPWH unit to achieve a low charge of R290 refrigerant. Another major modification was the replacement of the baseline compressor with a compressor designed for R290. Tests were conducted in a field environment (a research and demonstration house) using programmed drawn profiles daily. The prototype that reduced the charge by 43–47% provided displayed performance comparable to the baseline unit regarding first-hour rating (FHR) and the uniform energy factor (UEF).

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Scaling Up: Demonstrating Risk Reduction and Cost Compression for Commercial Heat Pump Water Heaters (CRADA 625) (Final Report)

This report is a final deliverable for project 81966: Scaling Up: Demonstrating Risk Reduction and Cost Compression for Commercial Heat Pump Water Heaters (CRADA 625) Commercial heat pump water heater (CHPWH) systems can significantly improve the energy efficiency of service water heating (SWH), aka domestic hot water (DHW), in commercial and multifamily buildings but have not yet achieved widespread adoption due to pricing, complexity, and perceived risk factors. The goal of this project – Scaling Up: Demonstrating Risk Reduction and Cost Compression for Commercial HPWHs (Scaling Up) – was to demonstrate and validate a holistic systems approach for CHPWHs that de-risks the technology, creating a reliable, cost-effective, and repeatable approach to CHPWH deployment.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Detailed Evaluation of Electric Demand Load Shifting Potential of Heat Pump Water Heaters

Future utilities will emphasize home appliances to reduce greenhouse gas emissions while providing electric load shifting and demand profile management. Heat pump water heaters (HPWH) have demonstrated the ability to cut water heating energy by more than 65% compared with conventional electric resistance waters (ERWH). Laboratory research was conducted on the load shifting potential of grid-connected heat pump water heaters (HPWH), compared to ERWHs. Testing applied different CTA-2045 command designs. Highly-controlled laboratory experiments were conducted on one ERWH and four HPWHs, including a prototype incorporating the new CTA-2045-B protocol feature allowing ‘advanced’ load up above the tank setpoint. The prototype unit with the B-protocol increased tank temperature by 15oF (8.3C) under the advanced load up providing an increase of 1.8 kWh of storage for a 50-gallon (189 liter) tank. The prototype includes a built-in mixing valve to meet anti-scalding codes. With the load-shaping ability of CTA-2045-B, utilities might be able to store excess renewable energy in connected tanks when renewable wind and solar resource production is high. Tests were performed under baseline conditions (no load shift) and under several load-shifting schemes, including load up and advanced load up, ahead of shed commands. Grid-connected HPWHs reduced peak demand by as much as 0.5 kW, depending on tank volume, time of day, control scheme, and draw profile.

heat pump water heater, Demand flexibility, load s↗

Factors Influencing Grid-connected Heat Pump Water Heater Performance in the Southeast U.S.

Grid-connected heat pump water heaters (HPWH) can shift electrical load while minimizing impacts to hot water availability for occupants. This capability provides a flexible grid resource to utilities seeking to manage peak loads Such load control also can feasibly improve renewable utilization within the utility electric production mix, for instance using off-peak generation during periods with high renewable energy generation. It also offers lower electric bills to customers through increased energy efficiency of HPWH and cuts greenhouse gas emissions. In particular, the Southeast U.S. due to its high penetration of electric water heating presents a promising opportunity for grid-connected HPWHs. This paper builds upon the results of an extensive HPWH load shifting field study conducted in 51 occupied homes in Florida using EcoPort technology (Butzbaugh et al, 2022). In 2022, only an initial evaluation was available. Here, long term load results are available as well as examination of various control strategies and influences. Analysis is conducted for HPWH energy use and load shifting performance based on home occupancy (i.e., low and high) and water heater location (i.e., conditioned and unconditioned) across different temperature profiles. An unexpected outcome of this analysis was the poor performance of HPWHs located in conditioned spaces, possibly because of inadequate air volume from improper installation. We did find higher demand reductions from 2-hour load ups and slightly improved for critical peak signals in the afternoon control periods. As expected, higher occupancy households showed great load reductions.

Fenaughty, Karen↗

Field Measurement of Central CO2 Heat Pump Water Heater for Multifamily Retrofit

Domestic hot water heating of multifamily buildings accounts for a substantial portion of the energy load of existing buildings. This load is made up of both the energy required to produce hot water and the energy needed to maintain the temperature of the heated water within a building’s distribution piping so that heat can be promptly delivered to building occupants as needed. Properly designed heat pump water heater (HPWH) systems have the ability to improve efficiency in both water heating and temperature control operations. Further, CO2 heat pump technology reflects a shift away from traditional refrigerants and toward refrigerants with low global warming potential (GWP). In this paper’s case study, a design consisting of multiple CO2 heat pump water heaters (commonly used in single-family homes) with a novel “swing tank” was proposed to meet the demand for domestic hot water heating and recirculation loop temperature maintenance. The proposed design was applied to the retrofit of a 60-unit, low-rise, multi-family building located in the Pacific Northwest of the United States. The purpose of this paper is to verify the performance of the system including the proposed “swing tank” in a centralized SHW system using CO2 HPWH. It also provides practical information and lessons learned from the retrofit project. Long-term monitoring data showed that the system had a coefficient of performance (COP) of three or greater and provided an average of 20 gallons of hot water per day per apartment. The results of this work indicate that residential-scale CO2 HPWH equipment and a “swing tank” design can efficiently provide domestic hot water heating and temperature maintenance for mid-sized multifamily buildings.

Banks, Adria↗

Performance evaluation of a wrapped around condenser for heat pump water heater applications

In this report, accurate performance evaluation of a wrapped-around condenser for heat pump water heaters (WHPWH) is critical since the COP of the system depends heavily on thermal stratification and condenser design. An analytical, quasi-steady state heat balance method has been developed to determine the optimal spacing between adjacent channels, tube diameter, tube shape, and total refrigerant charge amount for the condenser. The heat transfer rate is compared among three approaches: the refrigerant thermodynamic model, the condenser-wrap fin model, and the analytical natural convection model on the inside of the tank for the three regions based on the refrigerant phase (e.g., super-heated, saturated, or subcooled). The heat transfer rate was predicted by a combination of slug-plug and annular flow for a D-shaped helical tube. Experimental data were used as boundary conditions for validating the model. The rate of heat transfer based on tube shape and tank wall temperatures was compared by CFD analysis. Parametric analysis indicates a tradeoff between refrigerant mass, pressure drop, tube diameter, and tube length to maximize the heat transfer rate. The model suggests the saturated region length can be extended by 400%, and the condenser pressure drop can be reduced by 23% with an optimal spacing pattern.

42 ENGINEERING↗

Model-based Co-Simulation of Heat Pump Water Heater with Phase Change Materials Thermal Energy Storage

The study analysis the behavior of a new developed heat pump water heater technology which integrates a phase change materials storage with a standard heat pump water heater to maximize the performance parameters of the Unified Energy Factor (UEF) and First Hour Rating (FHR). A model-based control development co-simulation platform is developed to include equipment models, such as heat pump, standard water tank, phase change materials storage tank, and integrate them with control model to support controls design, analysis, verification, and validation. Simulation results are compared with lab test results to validate the accuracy of developed co-simulation platform

Sun, Jian↗