Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “heat of absorption”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

A Multifaceted Analysis of Chemical-Absorption Heat Pump Technology for Integrated Energy Systems

Integrated Energy Systems (IES) research and development is essential for improving the economic usage of lowcarbon energy sources such as nuclear power, solar, and wind in the U.S. An ideal IES uses various energy sources and delivers energy to the power grid and industry as efficiently as possible. As part of this effort, there are many opportunities to use low-carbon energy for industries requiring process heat for production of many chemicals and fuels [1]. Currently, industries only have the option to burn CO2 emitting fuels or use resistance heaters for this process heat. Using resistance heaters is one way to electrify a process, allowing for low-carbon energy sources to be used, but is an inefficient method unless temperatures exceed 1000?C. Heat pumps have long been used to provide efficient heating or cooling by moving heat instead of generating it. More traditional heat pumps such as vapor compression heat pumps and absorption heat pumps are limited to temperatures below 300?C due to refrigerant and component material limits. However, chemical heat pumps have been investigated as an option for pumping heat at temperatures above 600?C [2], making the heat more applicable to many more chemical and fuel production processes.

11 - NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Improving Reliability, Weight and Cost of Gas-Fired Absorption Heat Pumps

The objective of the project was to identify and verify a viable path for the use of aluminum tubes in evaporators for gas-fired ammonia-water absorption heat pumps (GAHP), via identification of a suitable alloy, coating, inhibitor, process, or combination, for the purpose of achieving weight and cost reduction.

03 NATURAL GAS↗

Pre-Commercial Scale-Up of a Gas-Fired Absorption Heat Pump

The project sought to advance the maturity of SMTI’s 80 kBTU/hr residential space and water heating GAHP from the engineering prototype stage (TRL-7) to pre-production readiness by addressing manufacturing, balance of system design and installation, cost, reliability, and field application questions. As part of this project, the project team has: (1) Matured the design package for a commercially ready product (2) Demonstrated compliance with relevant ANSI standards (3) Completed manufacturing and assembly process specifications (4) Completed total production cost estimates and capital equipment requirements (5) Initiated component and system level reliability assessments (6) Completed a small field demonstration including measured performance, installation requirements and expected costs, and customer/key stakeholder feedback. (7) Completed a Techno-economic analysis for representative applications and climate zones, including justification for utility incentive programs. (8) Completed a market intelligence report. Scope of Work: A multi-faceted project was completed that included: (a) design for manufacturing tasks for both the sealed system and balance of system, (b) development and trial of key manufacturing processes and techniques, (c) evaluation of component and system level reliability, (d) exploration of make/buy decisions including impact on cost and required capital. Additionally, (e) installation and monitoring of a small number of field test units was completed to demonstrate energy savings and collect customer/installer feedback, and (f) a focused market research task was completed to explore potential barriers and improve market introduction plans. These tasks addressed many of the remaining technical risks regarding long-term reliability, verification of manufacturing cost estimates and identification of cost concerns, identify installation and balance of system design criteria necessary to achieve energy savings and installed cost goals, and identify market barriers and strategies prior to product market introduction.

03 NATURAL GAS↗

Heating, ventilation, air conditioning and refrigeration system

A heating, ventilation, air conditioning and refrigeration (HVAC/R) system includes a sorption circuit including a heat absorption heat exchanger in fluid communication with a primary fluid flow source such that a primary fluid flow from is directed therethrough. The heat absorption heat exchanger is configured to exchange thermal energy between the primary fluid flow and a secondary fluid flow. A sorption heat exchanger includes a sorbent material to adsorb or absorb the primary fluid flow, generating thermal energy. The sorption heat exchanger is configured to transfer the generated thermal energy to a tertiary fluid flow. A heat exchange circuit is in fluid communication with the sorption circuit and includes a control valves connected to both the secondary fluid flow and the tertiary fluid flow configured to selectably direct the secondary fluid flow and/or the tertiary fluid flow to a conditioning heat exchanger or an ambient heat exchanger.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Sorption heat pump and control method

A method operates an absorption heat pump system, specifically the flow of hydronic cooling fluid through the condenser during system start-ups, or when the cooling fluid temperature is low. To minimize the time for an absorption heat pump to reach full cooling or heating capacity, it is desirable for the high side pressure to increase as fast as possible, and the low side pressure to decrease as fast as possible. Since the high side pressure is a function of the temperature of the refrigerant exiting the condenser, if the condenser cooling fluid temperature is low, the corresponding high side pressure will be low, which may not permit adequate working fluid flow rates from the high pressure side of the system to the low pressure side.

Garrabrant, Michael A.↗

Effects of Internal and External Heat Sources on Cladding Microstructure and Rupture Performance

In the event of a Loss of Coolant Accident (LOCA), the primary supply of cooling water for a nuclear reactor is lost, leading to a significant pressure differential across the cladding wall. Without adequate cooling, the fuel rods continue to heat as a result of fission reactions. Research at Oak Ridge National Laboratory’s (ORNL’s) Severe Accident Test Station (SATS) is currently focused on evaluating fuel cladding performance using an external infrared lamp as a heat source, whereas legacy testing primarily utilized an internal heating approach. While external heating may better simulate the effect of neighboring fuel rods heating a central rod, it may not accurately represent the internal heat absorption from the fuel during accident transients. The heating dynamics depend greatly on the fuel rod's position within the bundle and the reactor. To fully understand the implications of a LOCA event and assess the influence of internal heating on cladding performance, combined internal heating and pressurization capability was developed at ORNL. Tests were conducted to compare cladding segments heated internally (representing heat from the fuel within the rod) and externally (representing heat from adjacent fuel rods). The findings indicate that both internal and external heating result in comparable rupture temperatures during 5°C/s laboratory LOCA tests and also agree with legacy test data. Axial temperature gradients and internal heat source dispersal were found to significantly impact cladding deformation and rupture geometry. Clear modifications were outlined to further improve the capability with heating rates above 5°C/s.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Effects of Internal and External Heat Sources on Cladding Microstructure and Rupture Performance

In the event of a Loss of Coolant Accident (LOCA), the primary supply of cooling water for a nuclear reactor is lost, leading to a significant pressure differential across the cladding wall. Without adequate cooling, the fuel rods continue to heat as a result of fission reactions. Research at Oak Ridge National Laboratory’s (ORNL’s) Severe Accident Test Station (SATS) is currently focused on evaluating fuel cladding performance using an external infrared lamp as a heat source, whereas legacy testing primarily utilized an internal heating approach. While external heating may better simulate the effect of neighboring fuel rods heating a central rod, it may not accurately represent the internal heat absorption from the fuel during accident transients. The heating dynamics depend greatly on the fuel rod's position within the bundle and the reactor. To fully understand the implications of a LOCA event and assess the influence of internal heating on cladding performance, combined internal heating and pressurization capability was developed at ORNL. Tests were conducted to compare cladding segments heated internally (representing heat from the fuel within the rod) and externally (representing heat from adjacent fuel rods). The findings indicate that both internal and external heating result in comparable rupture temperatures during 5°C/s laboratory LOCA tests and also agree with legacy test data. Axial temperature gradients and internal heat source dispersal were found to significantly impact cladding deformation and rupture geometry. Clear modifications were outlined to further improve the capability with heating rates above 5°C/s.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Investigation of fouling mechanisms for diesel engine exhaust heat recovery

The effect of diesel engine exhaust fouling on heat and mass exchangers for waste heat recovery is investigated. Experiments are conducted for a range of operating conditions relevant to the use of the waste heat from a diesel engine for powering a 2.71 kW capacity absorption heat pump. Thermal resistances of fouling layers as well as their effects on pressure drop are determined, and the underlying mechanisms for deposition and removal are investigated. Fouling layer effects are most severe for the lowest coolant temperatures and 100% generator load. At these conditions, the fouling thermal resistance is approximately 70% of the total resistance, and the ratio of the steady-state pressure drop to the baseline pressure drop is 3.25. Flow induced shear is found to be the primary growth inhibiting mechanism at high exhaust velocities. Findings from this study can guide heat exchanger design for a variety of waste heat recovery systems.

04 OIL SHALES AND TAR SANDS↗

Effect of melting processes on the structure and precipitation of a heavy rainstorm in Beijing

Abstract Beijing and its surrounding areas experienced a torrential rainstorm from July 21 to 22, 2012. Previous studies have shown that melting was the main rainwater source in this process. In this paper, melting conversion processes were set to zero (NPMLT test) to analyze the effect of microphysical processes on the structure and precipitation of the convective system. The results showed that without the melting processes, the wind shear at the 700 hPa level decreased, and the wind field in Beijing and its surrounding areas changed. The cold front system moved faster, and the rainfall amount only reached the low rain level, much lower than that during the actual rainstorm. The hydrometeors sources had apparently changed. Though the latent heat release was large and little latent heat absorption occurred in the NPMLT test, the net latent heat did not affect the development of the convective system, and the precipitation was low. Therefore, microphysical processes greatly influence precipitation and convective system.

Guo, Chunwei↗

The encasulation effect on thermal performance of micro-encapsulated phase change materials during energy absorption

Understanding the performance of the thermal storage materials is required to successfully meet the needs of next generation concentrating solar power projects. This study focuses on the thermal characteristics of the micro-encapsulated phase change material (MEPCM) with metallic core under high temperature. A numerical model was developed and verified to study the transient heat absorption process of MEPCMs made of tin, aluminum and copper core. Convective heat transfer rate, total energy absorption and volumetric energy density were presented. The effect of encapsulation on theses variables was analyzed under various boundary and initial conditions. Its impact on characteristic time variables was discussed. The method presented can be adopted to analyzing both manufacturing and application processes for MEPCMs of various compositions, during which melting and solidification happen. Given certain operating conditions, the results from the model can be referenced to obtain optimal thermal performance of these materials.

Benner, Jingru↗

Heat Exchanger Design Optimization for Mitigation of Diesel Engine Exhaust Fouling

Abstract The design optimization of a diesel exhaust-coupled heat and mass exchanger that drives a 2.71 kW cooling capacity absorption heat pump is presented in this study. Fouling layer thermal resistance and pressure drops from single-tube experiments are used to develop a thermodynamic, heat transfer, and pressure drop model for the exhaust-coupled desorber. A parametric study is performed to select a desorber design that meets system performance while minimizing footprint. Experimental heat duties and pressure drops are within 10% and 3%, respectively, of the model predictions. Thus, large data sets from single-tube experiments with representative geometries are successful in accounting for fouling effects at the component level. Desorber design optimization based on this approach ensures continued heat pump performance after fouling. This study, along with the single-tube experiments, presents a systematic approach to design exhaust-coupled heat exchangers while considering the effects of fouling. These results are applicable for a wide range of waste-heat recovery applications, and this method can be extended to different geometries and operating conditions.

Energy & Fuels↗

Internally cooled membrane-based absorber for dehumidification and water heating: Validated model and simulation study

This report presents a comprehensive model for advanced membrane-based absorber components accounting for three separate fluid streams, one of them providing internal cooling, with complex flow patterns. The model was implemented with various liquid desiccants and their properties (including LiCl, CaCl 2 , and [emim][OMS] ionic liquid [IL]). The model has been validated using data from two laboratory prototype absorbers, one with CaCl 2 as the working fluid and one with an IL as the working fluid. Entropy analysis was further carried out to verify the model and understand effect of internal cooling on the entropy variation of three fluid streams. The developed model and codes are expected to enable detailed configuration optimization and provide in-depth understanding of three-fluid heat and mass exchanger (HMX) performance. The paper also describes parametric studies of the HMX components in utilizing the latent heat removed in space cooling to heat water and numerically explores the unique benefit of its application in a semi-open absorption heat pump water heater. The results show that a single three-fluid HMX has the potential to achieve simultaneous dehumidification and water heating efficiently at cost effectiveness, particularly in hot and humid climates.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Energy demand reduction in the built environment using shallow geothermal integrated energy systems: Part II – Hybrid ground source heat pump for building heating

The research collection aims at finding the various possible opportunities for the effective integration of shallow geothermal energy (SGE) to decrease the energy demand in the built environment and to reduce emission associated with it. The direct utilization of SGE using a ground source heat pump (GSHP) has been reviewed in comprehensive review part I and part II. From the extensive review, we have found that the hybrid GSHP is needed to avoid ground thermal imbalance and peak demand. Hybrid GSHP can adopt various supplemental heat sources and sinks according to the local climatic conditions and the balance of energy demands. The primary focus on the integration of subsystems such as biomass, solar energy (PV, PVT, and collector), phase change material, micro gas turbine, and absorption heat pump with GSHP is presented for heating application. This comprehensive review part III highlights the recent research findings and a potential gap in hybrid GSHP for further research and developments

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Dynamic energy system modeling using hybrid physics-based and machine learning encoder–decoder models

Three model configurations are presented for multi-step time series predictions of the heat absorbed by the water and steam in a thermal power plant. The models predict over horizons of 2, 4, and 6 steps into the future, where each step is a 5-minute increment. The evaluated models are a pure machine learning model, a novel hybrid machine learning and physics-based model, and the hybrid model with an incomplete dataset. The hybrid model deconstructs the machine learning into individual boiler heat absorption units: economizer, water wall, superheater, and reheater. Each configuration uses a gated recurrent unit (GRU) or a GRU-based encoder–decoder as the deep learning architecture. Mean squared error is used to evaluate the models compared to target values. The encoder–decoder architecture is over 11% more accurate than the GRU only models. The hybrid model with the incomplete dataset highlights the importance of the manipulated variables to the system. The hybrid model, compared to the pure machine learning model, is over 10% more accurate on average over 20 iterations of each model. Automatic differentiation is applied to the hybrid model to perform a local sensitivity analysis to identify the most impactful of the 72 manipulated variables on the heat absorbed in the boiler. The models and sensitivity analyses are used in a discussion about optimizing the thermal power plant.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Thermodynamic modeling of MDEA(aq)-NH 3 (aq)-K 2 CO 3 (aq)-CO 2 (aq) using the Extended UNIQUAC model

Here, the development of advanced processes for carbon dioxide capture requires reliable thermodynamic models to ensure accurate process design. This work presents an optimized parameter set of the Extended UNIQUAC model for advanced mixed solvent solutions containing CO 2 -MDEA-NH 3 -K 2 CO 3 in water. The model was parameterized using vapor–liquid equilibrium, pure component saturation pressure, excess enthalpy, heat of absorption, molar heat capacity, apparent molar heat capacity, and solid–liquid equilibrium. These thermal and equilibrium properties cover temperatures between 253.6 K to 600 K and pressures up to 75.6 bar. The current model represents an extension of previous versions that were suitable for modeling aqueous NH 3 and K 2 CO 3 solutions. This parametrization accounts for molecular interactions between MDEA and these two components, which allows for the design of advanced capture processes. This paper demonstrates that the new model parameters are valid within the range of operational conditions typically found in CO 2 capture processes.

42 ENGINEERING↗