Filling Data Deserts to Understand Urban Airflow and Heat Mitigation
Presentation of Filling Data Deserts to Understand Urban Airflow and Heat Mitigation at Boston University Biogeoscience Seminar Series in Upton, Boston, MA in Oct 2025
SEARCH · Engineering Papers
Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.
Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.
Presentation of Filling Data Deserts to Understand Urban Airflow and Heat Mitigation at Boston University Biogeoscience Seminar Series in Upton, Boston, MA in Oct 2025
We are living through a “heatshed” moment, a critical turning point in which heat must be rapidly addressed to protect health and livelihoods worldwide. The year 2024 was the hottest on record since global records began in 1850, and the past 10 years were the hottest decade in recorded history. Although extreme heat is the top weather-related killer in the United States, affecting livelihoods and economies, cities and nations dedicate more attention and resources to other climate hazards, such as hurricanes, floods, droughts, and wildfires. In this commentary, we argue that heat resilience must be rapidly advanced through heat mitigation, heat management, and heat governance efforts to ensure thriving communities in the face of an overheating world.
This study evaluates the effectiveness of various urban heat island (UHI) overheating mitigation strategies and their associated impacts on urban cloud dynamics and thermal processes. This study shows cloud-resolving and urban-resolving modeling results estimating the impact of Houston-Galveston heat mitigation scenarios and other resilient strategies contemplated in the Climate Adaptation Plan and Resilient Houston reports. The simulated scenarios include high intensity green rooftops, rooftop photovoltaic solar panels, enhanced urban irrigation, white/cool roofs and roads, and street trees. We contrast the adaptation scenarios against a present baseline case, a no city scenario and a larger and denser city as projected by the Houston-Galveston Area Council for 2045. During the daytime, cooling strategies such as cool roofs, cool roads, and green roofs exhibit superior performance in mitigating urban overheating. At night, enhanced urban irrigation emerges as the most effective cooling intervention. Cooling strategies significantly reduce sensible heat flux partitioning during the day, a process that reduces the uplift of air, suppressing the formation of urban shallow cumulus clouds. The extent of urban cloud mixing ratio is reduced in proportion to the decrease in sensible heating. Under the BEP-Tree scenario, which includes wind effects and evapotranspiration driven by a stomatal conductance model, urban trees demonstrated negligible environmental cooling effects and minimal urban cloud modifications. In contrast, the scenarios with more urban cooling and higher latent heat fluxes led to suppressed urban clouds. The net cooling effect achieved by the heat mitigation strategies is influenced by a combination of indirect processes, including the reduction of downwelling longwave radiation flux, due to reduced cloud presence, while some warming is attributed to a modest increase in shortwave radiation that offsets the cooling benefit. Additionally, reduced heat dissipation, weakened thermal gradients, and diminished vertical mixing over urban areas further moderate the cooling potential. These findings highlight the pivotal role of clouds and moist atmospheric processes in shaping the UHI effect and offer insights for designing more effective urban cooling strategies.
As urbanization and climate change progress, understanding and addressing urban heat becomes a priority for climate adaptation efforts. High temperatures concentrated in the urban core can drive increased risk of heat-related death and illness as well as increased energy demand for cooling. However, modeling the urban microclimate is an ongoing field of research typically burdened by an imprecise description of the built environment, incomplete observational records, significant computational cost, and a lack of high-resolution estimates of the impacts of increasing temperatures. Here, we present computationally efficient machine learning methods that can improve the accuracy of urban temperature estimates when compared to historical reanalysis data. These models are applied to a neighborhood in Los Angeles, and we compare the energy benefits of heat mitigation strategies to the impacts of climate change. We find that cooling demand is likely to increase substantially through midcentury, but engineered high-albedo surfaces could lessen this increase by more than 50 %. The corresponding increase in winter gas heating offsets the summer cooling benefit in the current climate, but total annual energy use from combined heating and cooling with electric heat pumps benefits from the engineered heat mitigation strategies under both current and future climates.
Natural gas flaring results in the waste of significant amounts of valuable domestic energy resources while also producing undesirable environmental impacts. Transforming natural gas into value-added chemicals via direct nonoxidative reactions presents a compelling alternative to flaring. However, traditional thermal reactor systems face challenges due to thermodynamic limitations and poor catalyst stability. Microwave-assisted reactions offer a sustainable, on-demand approach for chemical production from natural gas, suitable for compact, flexible reactor systems at the well-site that can be powered by renewable energy. This method offers a novel, non-traditional approach in catalyst activation and product selectivity compared to a conventional thermal method, potentially leading to faster rates, higher selectivities, and higher conversion efficiencies. Despite these advantages, challenges exist, such as the low microwave-sensitivity of the state-of-the-art zeolite catalyst that is highly active for the methane dehydroaromatization reaction. This presentation will discuss recent research from the National Energy Technology Laboratory concerning microwave-assisted natural gas conversion directly into aromatics. It will address the difficulties with microwave heating of traditional thermochemical catalysts, and the application of Multiphysics modeling to understand temperature and field strength in the reactor, to enhance chemical conversion. The presentation will also cover how heating aids can mitigate heating challenges and transform microwave catalysis into a quasi-thermal kinetic problem. Additionally, catalyst activation and deactivation under microwave conditions will be examined, along with the future outlook and needs for microwave enhanced catalysis applications.
KSTAR has recently undergone an upgrade to use a new tungsten divertor to run experiments in ITER-relevant scenarios. Even with a high melting point of tungsten, it is important to control the heat flux impinging on tungsten divertor targets to minimize sputtering and contamination of the core plasma. Heat flux on the divertor is often controlled by increasing the degree of detachment of scrape-off layer plasma from the target plates. In this work, we have demonstrated successful divertor detachment and heat exhaust dissipation control experiments using two different methods. The first method uses attachment fraction as a control variable which is estimated using ion saturation current measurements from embedded Langmuir probes in the divertor. The second method uses a novel machine-learning-based surrogate model of 2D UEDGE simulation database, DivControlNN. We demonstrated running inference operation of DivControlNN in realtime to estimate heat flux at the divertor and use it as the control variable in a feedback loop with impurity gas flow. We present interesting insights from these experiments including a systematic approach to tuning controllers and discuss future improvements in the control infrastructure and control variables for future burning plasma experiments.
Anthropogenic heat (AH) from buildings contributes to urban overheating, especially during heat waves, yet building retrofit studies usually evaluate energy savings without assessing impacts on AH. This study quantifies how common building retrofit measures affect both building energy use and AH emissions across the City of Los Angeles. Using a bottom-up urban building energy modeling framework coupled with high-resolution local weather from the Weather Research and Forecasting model with Building Effect Parameterization (WRF-BEP), we evaluate eleven retrofit measures and two multi-measure retrofit packages. HVAC and LED lighting retrofits provide the largest city-wide annual site energy savings, while roof coating is most effective for reducing AH. A package optimized for energy savings reduces summer site energy use by about 32% (2.3 TWh), while a package incorporating AH-focused measures reduces the total AH by over 50% (137 PJ) with minimal difference in energy savings. The AH-aware package produces substantially greater urban cooling, reducing mean near-surface air temperature by up to 0.62 ℃ and peak temperature by up to 3.79 ℃. These results show that retrofit strategies selected only for energy savings may overlook major opportunities for urban heat mitigation. The study provides a framework for integrating AH into building retrofit planning and urban heat resilience policy.
Vacant lots are often perceived as contributing to negative socioeconomic and environmental impacts on surrounding communities. However, they also offer opportunities for strategic interventions that promote heat resilience. This study uses a decision-scale congruence analytic approach to examine the correlation between extreme heat and community resilience in the context of vacant lots in the city of Mesa, Arizona. By identifying and analyzing over 1,200 vacant lots, we assessed spatial patterns of Community Resilience Estimates (CRE) for Heat and Body Heat Storage (BHS) to understand their correlation at the unit of analysis of vacant lots, where key decisions are made concerning land use. The results reveal a nonrandom spatial distribution of CRE for Heat and BHS across Mesa’s vacant lots. Vacant lots are disproportionately concentrated in neighborhoods with lower resilience, exacerbating heat exposure. Communities with limited access to cooling infrastructure, tree canopy, and other resources experience lowered heat resilience. A positive correlation between CRE for Heat and BHS shows that areas with higher heat exposure tend to have lower community resilience, reinforcing the need for cooling interventions. This study highlights the potential for converting vacant lots into heat-resilient, community-serving spaces. Using our findings, decision makers can identify priority areas and leverage vacant lots to mitigate heat impacts and foster community resilience.
Extreme heat is a major cause of weather-related deaths in the United States. To address this, a heat vulnerability index (HVI) is crucial for assessing heat risk and identifying vulnerable urban areas and populations, supporting city planning and emergency response. Current HVI studies often use Principal Component Analysis (PCA) on environmental, socioeconomic, and medical data to aggregate vulnerability indicators into a single index. However, these fixed aggregation weights struggle to adapt to different use cases, which may require varying focuses. Moreover, existing tools primarily consider outdoor heat exposure, providing an incomplete picture of actual exposure, as people spend most of their time indoors. Our research introduces an HVI web mapping tool that addresses these gaps in the literature by: (1) allowing flexible weights to adapt to different use cases, and (2) uniquely integrating both outdoor and indoor heat exposure by considering building characteristics for a more comprehensive risk assessment. We demonstrated this tool in two California cities with contrasting climates: Fresno (inland, arid, hot summers) and Oakland (temperate coastal). This HVI mapping tool provides essential decision support for policymakers and stakeholders in both short-term heat mitigation and long-term urban planning for building interventions and infrastructure development.
Extreme heat conditions pose significant indoor survivability challenges for resource-constrained communities, which often lack access to cooling, have poorly insulated homes, and face compounding socioeconomic vulnerabilities. Moreover, concurrent power outages worsen health risks and heat-related illnesses. It is therefore crucial to develop innovative and affordable cooling approaches to protect vulnerable populations. This study assesses the efficacy of “cool rooms”– a designated space within a home equipped with passive and low-power active cooling measures to maintain safe indoor temperatures during extreme heat events and power disruptions. Using a physics-based building energy modeling approach, we evaluate the efficacy of various retrofit packages in maintaining thermal safety within the cool room under recent extreme heat conditions. The results indicate that passive measures can reduce 64% of hours with unmet standard effective temperatures, while the combination of passive and low-power active measures with built-in batteries further cuts this to 86%. Nevertheless, these strategies remain insufficient to maintain indoor thermal safety during extended outages. In contrast, integrating a solar-powered mini-split heat pump, whose technical potential was evaluated in this study, reduces indoor air temperatures below the 28 °C overheating threshold and significantly improves indoor habitability. The localized cool room strategy also offers potential for grid resilience by reducing peak electricity demand by up to 70% compared to whole house cooling during heat waves. The findings can inform the development of actionable heat mitigation plans and retrofit policies for residential communities with relatively low adoption of air conditioning such as warm marine climates.
Agrivoltaics, the integrated land use combining renewable energy production and agriculture, can potentially address key challenges faced by urban communities, including limited access to vacant land, fresh produce, and electricity. However, urban agrivoltaics has rarely been considered a viable solution, primarily due to a lack of experimental systems demonstrating the functionality of urban food production or green spaces alongside solar energy production. To evaluate the potential of solar photovoltaics to help mitigate heat stress on urban agriculture and green spaces in a temperate climate, we examined the microclimatic changes introduced by an urban agrivoltaics system (UrAV) when combined with vegetable crops and turfgrass, respectively. Accordingly, we installed an experimental setup instrumented with environmental sensors to compare full-sun conditions with those of an agrivoltaics system designed for urban environments. We found minimal differences for both land cover types between the control and agrivoltaics sites in air and soil temperature. However, during periods of intensified summer heat, temperatures beneath the panels cooled due to reductions in wind speed and relative humidity, which impeded the movement of hot, moist air and reduced reference evapotranspiration. Further, soil moisture in UrAV was highly spatially heterogeneous, influenced by the layout of the photovoltaic panels and their support structure, which redistributed rainfall and controlled where solar radiation could penetrate and drive evapotranspiration. Overall, our results suggest that PV-induced environmental changes in temperate climates are compatible with cultivating turfgrass or appropriate crops. These findings can help planners and designers integrate agrivoltaics into community gardens, farms, and green spaces in temperate cities.
Domain walls are leading platforms for the development of ultra-low power switching and memory devices due to their potential to be moved, created, and erased in real time and to mitigate heat flux. Interface vs wavelength size effects unfortunately preclude the measurement of phonons by traditional spectroscopic techniques, so it has been challenging to unravel the primary excitations of the lattice and the symmetries that they represent across these functional interfaces. In this work, we employ synchrotron-based near-field infrared nanospectroscopy to image polar domain walls in multiferroic Ni 3 TeO 6 . This is a unique platform because, in addition to hosting polar and chiral domains that are interlocked with one another, Ni 3 TeO 6 displays both charged and neutral interfaces depending upon the direction allowing the development of structure–property relations. From a local structure and a strain point of view, we find charged walls that are twice as wide as neutral walls as well as strong frequency shifts of vibrational modes across the charged walls. The near-field amplitude drops across the walls as well. We discuss these trends in terms of polarization and chirality as well as phonon lifetimes at functional interfaces.
The Large, Uniform Plasma for Ionizing Neutrals (LUPIN) is a radio-frequency (RF) inductively coupled plasma (ICP) chamber for demonstrating plasma performance of an RF ICP positive ion source upgrade for the DIII-D neutral beam injection (NBI) system. LUPIN will be used to investigate ion source physics, including neutral gas dynamics, plasma density uniformity, interactions with Faraday shields, and power coupling to novel RF antenna designs. LUPIN has an RF generator capable of delivering 20 kW of power at 2 MHz, which is coupled into a cylindrical quartz vessel measuring 20 cm in length and 10 cm in radius. This configuration matches the power density requirements for a full-scale ion source. Target hydrogen and deuterium plasma densities exceeding 10 18 m -3 would relate to extracted ion current densities of 2100 A/m 2 for 10s. Vacuum conductance and gas flow calculations predict a maximum achievable neutral gas flow rate of 1675 Pa ⋅ L/s at 5 Pa of He, which mimics the gas flow of the DIII-D NBI system. Designs have been developed for an internal Faraday shield to mitigate heat flux and ion sputtering on the dielectric vessel. Thermomechanical finite element simulations demonstrated the Faraday shield design to be capable of withstanding anticipated heat loads from worst-case operation scenarios. Finally, results of upcoming experimental investigations on LUPIN will guide the design of a full-scale prototype for DIII-D integration.
The National Spherical Torus Experiment Upgrade (NSTX-U) is preparing to resume operation, representing a crucial step toward realizing compact, cost-effective fusion pilot plants. In advance of this, extensive modeling and data analysis have been conducted to advance the physics basis for low-aspect-ratio, high-performance plasma regimes, focusing on three core objectives: confinement and stability, power and particle handling, and steady-state operation. Significant progress has been made in understanding the electron temperature flattening in high-β plasmas, which is shown to be driven by a complex interplay of magnetohydrodynamic instabilities (e.g. non-resonant infernal modes), fast-ion-driven Alfvén eigenmodes, and electron and ion-scale micro-instabilities, particularly Kinetic Ballooning Modes (KBMs), whose destabilization is strongly dependent on parallel magnetic field fluctuations (δB ∥ ). Furthermore, a new gyrokinetic critical pedestal model was developed, accurately predicting pedestal structure by identifying KBMs as the primary stability limit, offering a critical constraint for future high-confinement scenarios. To address the challenge of high heat flux, novel liquid lithium plasma-facing components were modeled. The analysis confirmed that lithium vapor shielding is a self-regulating mechanism for heat mitigation, while also emphasizing that strong main ion parallel flow is essential to minimize core lithium contamination. Finally, progress toward steady-state operation was anchored by developing the required physics basis and control tools. This includes predictive modeling for reversed magnetic shear sustainment, demonstrating that magnetic island-induced bootstrap current reduction is negligible in STs, and advancing real-time control and disruption avoidance capabilities. The development of high-speed surrogate models (e.g. MMMNet) provides computationally efficient tools vital for non-inductive scenario optimization and integrated, low-disruptivity operations planned for NSTX-U.
The Baltimore Social-Environmental Collaborative (BSEC) Urban Integrated Field Laboratory seeks a new paradigm for urban climate research. Motivated by deep uncertainties in urban climate and the future of urban systems, BSEC works collaboratively across institutions and stakeholder groups to co-generate the science needed to advance energy security and resilience to extreme events across the city of Baltimore, Maryland, USA, and to do so in a manner that can inform similar efforts in other cities. BSEC begins with stakeholder priorities (health, affordable energy, etc) and designs observation networks and models to deliver climate science to address them. This takes the form of an iterative collaborative cycle, in which an initial research strategy is repeatedly updated in conversation with community partners, and researchers and stakeholders learn from each other. To date, this cycle has included multiple rounds of collaborative deliberation on urban heat mitigation, in which a multicriteria decision tool has been updated with more community-relevant spatial structure and modified optimization metrics. The guiding objective of this cycle is to inform potential ‘secure and resilient pathways’ for energy and infrastructure. In doing so, BSEC addresses fundamental urban science questions in natural and social sciences. It also tests our ability to integrate this science in a manner that advances participatory decision-making for urban resilience.
This data and code package supports the analysis presented in “Beyond Surface Cooling: Comprehensive Field Assessment of Reflective Pavement Thermal Performance in Phoenix, Arizona” and provides fully reproducible workflows for evaluating the thermal performance of cool pavement treatments in a hot urban environment. The dataset integrates multi-modal field measurements collected across residential and nonresidential settings, including mobile air temperature traverses, stationary air temperature monitoring, residential mean radiant temperature (MRT) measurements, subsurface temperature profiles, and controlled testbed observations. The data package contains raw and processed datasets in comma-separated value (CSV) format, accompanying metadata files describing site characteristics and measurement protocols, and R scripts (.R files) used for data cleaning, time synchronization, spatial and temporal matching, quality control filtering, statistical comparison, and figure generation. All analyses were conducted using R (version ≥ 4.2.0) with commonly available packages (e.g., tidyverse, lubridate, data.table, ggplot2). No proprietary software is required to reproduce results. Field campaigns were designed to quantify the effects of high-reflectance pavement coatings on surface temperature, near-surface air temperature, subsurface heat propagation, and radiative heat exposure. Temporal alignment procedures include standardized timestamp conversion and nearest-neighbor matching of high-frequency sensor measurements to stop-based metadata within defined tolerance windows to ensure comparability across instruments. The workflows generate summary statistics, treatment–control contrasts, depth-dependent thermal gradients, and time-series visualizations used in the associated publication. By integrating mobile, stationary, radiative, and subsurface measurements within a unified and transparent processing framework, this package enables comprehensive evaluation of cool pavement performance across multiple thermal exposure pathways and supports reuse in future urban heat mitigation and climate resilience studies.
Global jet fuel demand is projected to grow to 165 billion gallons by 2050 and there is growing interest in the aviation industry to understand the capabilities of alternative energy carriers. This report considers several potential energy carriers, reviewing their production potential, operational considerations, and economic implications to inform potential next steps in aeronautics research. The following energy carriers (i.e., fuels) were evaluated in this study for future use in aviation: sustainable aviation fuel (SAF) - both biomass-based and power-to-liquids (PtL) - based SAF - cryogenic hydrogen (LH 2 ) - also known as liquid hydrogen - liquefied natural gas (LNG), liquefied ethane (LE), and Jet X. The barriers and opportunities for the evaluated energy carriers vary. SAF is a commercially available drop-in fuel compatible with existing aircraft and infrastructure. SAF is limited by both higher prices and slow commercialization of multiple pathways using different feedstocks necessary to significantly grow supply. Cryogenic fuels, in contrast, have very different thermal, physical, and chemical properties than SAF and Jet A, requiring the construction of new airport storage and dispensing infrastructure and the design of new aircraft energy systems capable of mitigating heat transfer and boil-off. Cryogenic fuels offer an opportunity to diversify aviation fuel carriers from domestic energy relevant for both energy security and resilience. This means cryogenic fuels are more of a longer-term solution for aircraft but are worth exploring for potential future cost savings and emissions benefits. Jet X refers to non-drop-in liquid hydrocarbon fuels in the early stages of investigation seeking favorable properties. There are substantial barriers to non-drop-in liquid aviation fuels that are not compatible with existing aircraft and fuel infrastructure.
Phase-3 testing of the pHB650 cryomodule at the PIP-II Injector Test Facility was conducted to evaluate the effectiveness of heat load mitigations performed after earlier phases of testing and to continue pinpointing any sources of unexpectedly high heat loads.. The programme measured HTTS, LTTS, and 2 K isothermal/non-isothermal loads under "standard", "linac", and "simulated dynamic" operating modes, recording data both inside the cryomodule and across the bayonet can circuits. Thermal-acoustic oscillations were eliminated by replacing the original G10 cooldown-valve stem with a stainless-steel stem fitted with wipers. A newly developed Python script automated acquisition of ACNET data, performed real-time heat-load calculations, and generated plots and tables that were posted to the electronic logbook within minutes, vastly reducing manual effort and accelerating feedback between SRF and cryogenics teams. Analysis showed that JT heat-exchanger effectiveness and temperature stratification in the two-phase and relief piping strongly influence the observed loads and helped isolate sources of excess heat. The campaign demonstrates that rigorous pre-test planning, real-time diagnostics, and automated reporting can improve both accuracy and efficiency, providing a template for future PIP-II cryomodule tests and for implementing targeted heat-load mitigations.