Heat Generation versus Heat Dissipation Maps for Batteries (Battery Safety Maps) [SWR-21-27]

NREL's Battery Safety Map (Heat Generation versus Heat Dissipation Maps for Batteries) generates a response surface that is grouped into regions where the battery is deemed safe from the propagation of thermal runaway, those where an engineering solution would render the battery safe, and finally instances where thermal runaway is inevitable. The demarcation for the different regions is provided by specifications or constraints imposed by the end user. NREL's Battery Safety Map is a user-defined subroutine that sweeps through a set of parameters describing the operating conditions and short-circuit scenarios for battery safety simulations. For each run, the electrochemical-thermal model implementing reaction kinetics and gas generation are run to evaluate the amount of heat generated. A thermal model then captures the amount of heat dissipation based on boundary conditions defined (e.g., forced convection, constant temperature at the surface, etc.). Based on the rate of heat transfer and the amount of heat generated, each run is classified into "safe," "mitigation possible," or "unsafe" zones. These categories are defined based on constraints or tolerance specifications provided by the end user.

Santhanagopalan, Shriram↗

Understanding the heat generation mechanisms and the interplay between joule heat and entropy effects as a function of state of charge in lithium-ion batteries

The thermal performance of lithium-ion battery cells is critical for ensuring their safe and reliable operation across various applications. In this study, we employed an isothermal calorimetry method to investigate the heat generation of commercial 18650 lithium-ion battery fresh cells during charge and discharge at different current rates, ranging from 0.05C to 0.5C, and across various temperatures: 20 °C, 30 °C, 40 °C, and 50 °C. Our findings revealed a direct correlation between heat generation and current rates, indicating that higher current rates lead to increased heat generation within the cells. Conversely, we observed that heat generation remained relatively stable as the temperature rose, suggesting that temperature changes within this range may not significantly impact the heat generation of fresh cells during typical operations. Furthermore, our study explored irreversible heat generation, which depends on the applied current and overpotential, using the galvanostatic intermittent titration technique at 0.05C–0.5C and 30 °C. Additionally, electrochemical impedance spectroscopy was performed on the same cells during charge and discharge at 20 °C, 30 °C, and 40 °C to analyze cell impedance. Finally, our results indicated a consistent dependence of impedance on the state of charge and depth of discharge, with a significant increase in impedance observed at the end of the discharge process.

25 ENERGY STORAGE↗

Effects of the Spin Heat Accumulation on the Heat Generation in a Quantum Dot Coupled to Leads

Heat generation by a spin-polarized current in a single-level quantum dot (QD) subjected to spin heat accumulation (SHA), which denotes the spin-dependent electron temperature, is studied by using the nonequilibrium Green’s function technique. The heat generation originates from the energy exchange between the conduction electrons and the phonon reservoir coupled to the QD. Due to the SHA, the spin-up and spin-down heat generations are opposite in sign, and each has a maximum when the QD level is aligned to the chemical potentials of the leads, where the electric current is zero. Under a magnetic field, the maxima of the spin-up and spin-down heat generations are shifted to different dot level regimes. Now total negative heat generation emerges, indicating that the electron absorbs heat from the phonon reservoir to the dot. By tuning the dot levels and the system temperature, the magnitude of the negative heat generation can be enhanced accompanied by weakened electric current, an ideal condition for the realization of nanorefrigerator.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

Effect of Temperature and FEC on Silicon Anode Heat Generation Measured by Isothermal Microcalorimetry

Isothermal microcalorimetry (IMC) was used to better understand parasitic reactions and heat generation from Si electrodes in the first 10 cycles using Li/Si half cells. Heat generation from cell polarization (ohmic heat), entropy changes (reversible heat), and parasitic reactions (parasitic heat) are separated and quantified. The effect of temperature and fluoroethylene carbonate (FEC) as an electrolyte additive are also explored. Our results show that at the C/10 cycling rate used here, ohmic heat makes the largest contribution to overall heat generation while reversible heat is the smallest. Ohmic heat generation increases with cycle number due to increasing internal resistance, though the effect is smaller for cells with FEC. Interestingly, capacity-normalized parasitic heat generation is largely unaffected by changes in temperature despite differing reaction kinetics. We show that this is caused by a decrease in average parasitic reaction enthalpy as temperature is increased. Further, cells with FEC display higher average parasitic reaction enthalpy than cells without. The average parasitic reaction enthalpies for all the Si electrodes we tested were lower than previously reported values for graphite, indicating that the SEI formed on Si is less stable.

25 ENERGY STORAGE↗

Heat generation by electronic current in a quantum dot spin-valve

Electric-current-induced heat generation in an interacting single-level quantum dot connected to ferromagnetic leads with noncollinear magnetizations is theoretically investigated. We find that when the two leads' spin polarization rates are identical and much smaller than unit, the magnitude of the heat generation is almost monotonously enhanced as the angle between the leads' magnetic moments is varied from zero to π, while the magnitude of the electric current is continuously suppressed. Moreover, the properties of the heat generation depend on the lead's spin polarization rate in different ways when the angle is varied. If at least one of the leads' spin polarization rate approaches to unit, the spin-valve effect of the heat generation is identical to that of the electric current. Now the previously found negative differential of the heat generation disappears when the angle approaches to π. As compared to the current, the heat generation is more sensitive to the system's asymmetry when one of the electrodes is half-metallic in noncollinear configurations.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Heat generation in electric double layer capacitors with neat and diluted ionic liquid electrolytes under large potential window between 5 and 80 °C

Here, this study investigates the effect of temperature on the heat generation and the associated electrochemical phenomena occurring in IL-based EDLCs. The EDLCs consisted of two identical activated carbon electrodes with neat Pyr14TFSI or Pyr14TFSI diluted in propylene carbonate (PC) as electrolytes. The instantaneous heat generation rate at each electrode was measured by isothermal calorimetry between 5 and 80 °C under constant current cycling and potential window of 2.5 V. First, the instantaneous heat generation rate was similar at each electrode in neat IL. However, it was smaller at the negative electrode in diluted IL and featured endothermic dips growing with increasing temperature > 40 °C due to overscreening effects, ion desolvation, and/or decomposition of PC. The irreversible heat generation was similar in each half-cell and decreased with increasing temperature due to the reduction in internal resistance, particularly with neat IL. The irreversible heat generation exceeded Joule heating in all cases, especially at high temperature and low current. This was attributed to ion desorption and charge redistribution in the porous electrodes. Finally, the reversible heat generation for both electrolytes was larger at the positive than at the negative electrode due to the difference in anion and cation sizes.

25 ENERGY STORAGE↗

Numerical and experimental investigation of melting with internal heat generation within cylindrical enclosures

There have been significant efforts by the heat transfer community to investigate the melting phenomenon of materials. These efforts have included the analytical development of equations to represent melting, numerical development of computer codes to assist in modeling the phenomena, and collection of experimental data. The understanding of the melting phenomenon has application in several areas of interest, for example, the melting of a Phase Change Material (PCM) used as a thermal storage medium as well as the melting of the fuel bundle in a nuclear power plant during an accident scenario. The objective of this research is two-fold. First a numerical investigation, using computational fluid dynamics (CFD), of melting with internal heat generation for a vertical cylindrical geometry is presented. Second, to the best of authors knowledge, there are very limited number of engineering experimental results available for the case of melting with Internal Heat Generation (IHG). An experiment was performed to produce such data using resistive, or Joule, heating as the IHG mechanism. The numerical results are compared against the experimental results and showed favorable correlation. Uncertainties in the numerical and experimental analysis are discussed. Based on the numerical and experimental analysis, recommendations are made for future work.

99 GENERAL AND MISCELLANEOUS↗

Thermal management challenges in lithium-ion batteries: understanding heat generation mechanisms

This paper investigates heat generation in commercial 18 650 lithium-ion battery cells and the thermal management challenges from their high energy density and electrochemical processes. Thermal effects can degrade performance, accelerate aging, and increase thermal runaway risk. Using isothermal calorimetry and EIS, the study emphasizes optimizing thermal behavior to improve battery efficiency, safety, and durability.

25 ENERGY STORAGE↗

Impact of the High Flux Isotope Reactor HEU to LEU Fuel Conversion on Cold Source Nuclear Heat Generation Rates

Under the sponsorship of the US Department of Energy National Nuclear Security Administration, staff members at the Oak Ridge National Laboratory have been conducting studies to determine whether the High Flux Isotope Reactor (HFIR) can be converted from high enriched uranium (HEU) fuel to low enriched uranium (LEU) fuel. As part of these ongoing studies, an assessment of the impact that the HEU to LEU fuel conversion has on the nuclear heat generation rates in regions of the HFIR cold source system and its moderator vessel was performed and is documented in this report. Silicon production rates in the cold source aluminum regions and few-group neutron fluxes in the cold source moderator were also estimated. Neutronics calculations were performed with the Monte Carlo N-Particle code to determine the nuclear heat generation rates in regions of the HFIR cold source and its vessel for the HEU core operating at a full reactor power (FP) of 85 MW(t) and the reference LEU core operating at an FP of 100 MW(t). Calculations were performed with beginning-of-cycle (BOC) and end-of-cycle (EOC) conditions to bound typical irradiation conditions. Average specific BOC heat generation rates of 12.76 and 12.92 W/g, respectively, were calculated for the hemispherical region of the cold source liquid hydrogen (LH2) for the HEU and LEU cores, and EOC heat generation rates of 13.25 and 12.86 W/g, respectively, were calculated for the HEU and LEU cores. Thus, the greatest heat generation rates were calculated for the EOC HEU core, and it is concluded that the conversion from HEU to LEU fuel and the resulting increase of FP from 85 MW to 100 MW will not impact the ability of the heat removal equipment to remove the heat deposited in the cold source system. Silicon production rates in the cold source aluminum regions are estimated to be about 12.0% greater at BOC and 2.7% greater at EOC for the LEU core in comparison to the HEU core. Silicon is aluminum s major transmutation product and affects mechanical properties of aluminum including density, neutron irradiation hardening, swelling, and loss of ductility. Because slightly greater quantities of silicon will be produced in the cold source moderator vessel for the LEU core, these effects will be slightly greater for the LEU core than for the HEU core. Three-group (thermal, epithermal, and fast) neutron flux results tallied in the cold source LH2 hemisphere show greater values for the LEU core under both BOC and EOC conditions. The thermal neutron flux in the LH2 hemisphere for the LEU core is about 12.4% greater at BOC and 2.7% greater at EOC than for the HEU core. Therefore, cold neutron scattering will not be adversely affected and the 4 12 neutrons conveyed to the cold neutron guide hall for research applications will be enhanced.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Development of understanding of disposability of high-heat-generating wastes in the UK - 15359

The inventory of radioactive wastes planned for geological disposal in the UK is diverse. This inventory includes a range of high-heat-generating wastes and potentially some other nuclear materials (some spent fuel, uranium and plutonium) that are subject to government policy decisions and therefore may be declared as wastes for geological disposal in the future. To ensure that safe disposal solutions can be developed, it will be necessary to understand the influence of this heat on engineered barrier systems for the range of generic disposal concepts being considered in the UK. Furthermore, waste producers need to develop packaging solutions for these materials that take account of any thermal constraints. For these reasons, RWM has established the High-heat-generating Wastes Project (Project Ankhiale), a dedicated project to enhance understanding of the factors affecting geological disposal of high-heat-generating wastes with a view to supporting future decision making and concept selection. The project has been established around a multi-disciplinary Integrated Project Team (IPT), comprising members of RWM, Amec Foster Wheeler and external experts, to provide a comprehensive approach across a range of technical disciplines. Phase 2 of the project, which comprises a series of specific technical activities, commenced in March 2013 and, since then, progress has been made across the following five broad categories: - Compilation of the inventory of UK high-heat-generating wastes;- Waste package performance work; - Development of a better understanding of thermal constraints for different buffer materials; - Exploration of the range of disposal parameters using a thermal dimensioning modelling tool; and - Concept engineering design work. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Thermal analysis to determine acceptable package loading and spatial configurations of high-heat-generating wastes - 15411

The inventory of radioactive materials planned for geological disposal in the UK is diverse. This inventory includes a range of high-heat-generating wastes and other radioactive materials not currently declared as waste including some spent nuclear fuel and separated uranium and plutonium. To ensure that safe disposal solutions can be developed, it will be necessary to understand the influence of this heat on engineered barrier systems for the range of generic disposal concepts being considered in the UK. For these reasons, Radioactive Waste Management Limited has established a dedicated project to enhance understanding of the factors affecting geological disposal of high-heat-generating wastes with a view to supporting future decision making and concept selection. One of the priority areas to be addressed within the High-heat-generating Waste Project (Project Ankhiale) concerns the effect of heat on the engineered barrier systems. The core focus of the work is to identify the thermal constraints on specific outline conceptual designs, building upon the findings of other work activities aimed at understanding the influence of heat on buffer materials. The constraints on the design relate to important features of the engineered barrier system and parameters such as waste package loading, package dimensions and package spacing. Work is underway to identify an acceptable range of designs and parameters for waste package disposal concepts and layout of the GDF. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Superior electrochemical performance and reduced heat generation in 3D printed vs. 2D tape-casted NMC622 electrodes

This study compares the charge storage mechanisms, thermodynamics behavior, ion transport, and heat generation in NMC622 electrodes fabricated using a novel 3D printing process and the conventional 2D tape casting process. First, potentiometric entropy measurements revealed that the charge storage mechanisms for both types of electrodes consisted of lithium deintercalation in a homogeneous solid solution of NMC622 followed by a transition from a hexagonal (H1) phase to another hexagonal (H2) phase through a monoclinic (M) phase. Both types of electrodes had similar thermodynamics behavior with overlapping entropic potential profiles. Furthermore, operando isothermal calorimetry at high C-rates indicated that the 3D printed electrodes featured larger specific capacity and better rate performance than the 2D tape-casted electrodes. The better performance of 3D printed electrodes was attributed to their larger electrode/electrolyte interfacial surface area and electrical conductivity as well as their faster lithium ion transport. As a result, the instantaneous heat generation rates were smaller in 3D printed electrodes than in 2D tape-casted electrodes, thus resulting in lower overall specific electrical energy and thermal energy dissipation per unit charge stored. Overall, additive manufacturing techniques offer great potential in producing electrodes with superior electrochemical performance and reduced heat generation for fast charging batteries.

25 ENERGY STORAGE↗

Environmental and Economic Assessment of Portable Systems: Production of Wood-Briquettes and Torrefied-Briquettes to Generate Heat and Electricity

This study assessed the environmental impacts and economic feasibility of generating heat using wood-briquettes (WBs), and heat and electricity using torrefied-wood-briquettes (TWBs). WBs and TWBs were manufactured from forest residues using portable systems and delivered to either residential consumers or power plants in the United States. An integrated cradle-to-grave life-cycle assessment (LCA) and techno-economic analysis (TEA) approach was used to quantify environmental impacts and minimum-selling prices (MSPs) of heat and electricity, respectively. Results illustrated that 82% and 59% of the cradle-to-grave global warming (GW) impact of producing heat resulted from the feedstock preparation in WBs and torrefaction in TWBs, respectively. About 46–54% of total cost in the production of heat were from labor and capital costs only. The GW impact of electricity production with TWBs was dominated by the torrefaction process (48% contribution). Capital cost (50%) was a major contributor to the total cost of electricity production using TWBs. The GW impacts of producing heat were 7–37 gCO₂eq/MJ for WBs, and 14–51 gCO₂eq/MJ for TWBs, whereas producing electricity using TWBs was 146–443 gCO₂eq/kWhe. MSPs of generating heat from WBs and TWBs were €1.09–€1.73 and €1.60–€2.26/MJ, respectively, whereas the MSP of electricity from TWBs was €20–€25/kWhe. Considering carbon and pile-burn credits, MSPs of heat and electricity were reduced by 60–90% compared to the base-case.

Sahoo, Kamalakanta (ORCID:0000000277635296)↗

An Improved Energy Deposition Model in MPACT and Explicit Heat Generation Coupling with CTF

The default energy deposition model in the CASL neutronics code MPACT assumes all fission energy is deposited locally in fuel rods. Furthermore, equilibrium delayed energy release is assumed for both steady-state and transient calculations. These approximations limit the accurate representation of the heat generation distribution in space and its variations over time, which are essential for power distribution and thermal-hydraulic coupling calculations. In this paper, an improved energy deposition model is presented in both the spatial and time domains. Spatially, the energy deposition through fission, neutron capture, and slowing-down reactions are explicitly modeled to account for the heat generation from all regions of a reactor core, and a gamma smearing scheme is developed that utilizes the gamma sources from neutron fission and capture. In the time domain, the delayed energy release is modeled by solving an additional equation of delayed heat emitters, similar to the equation of delayed neutron precursors.To allow the explicit heat generation coupling, the interfaces between MPACT and CTF were updated to transfer separate heat sources for different material regions (fuel, clad, moderator and guide tube). The results show that the distributions of the energy deposition between MPACT and MCNP agree very well for various 2-D assembly and quarter-core problems without TH feedback. The MPACT/CTF coupled calculation for the hot full power quarter-core case exhibited a reduced peak pin power by 2.3% and a reduced peak fuel centerline temperature by 17 K when using the explicit energy deposition and heat transfer. The new model also shows a maximum 100 pcm keff effect on assembly depletion problems and an increased overall energy release by 7% in a PWR reactivity-initiated accident (RIA) problem.

Liu, Yuxuan↗

Improved method for calculating the radiation heat generation in the BOR-60 reactor

The results of theoretical and experimental studies aimed at determining the radiation heat generation in the BOR-60 reactor reveal the drawbacks of the computational methods used at present. An algorithm that is free from these drawbacks and allows one to determine the radiation heat generation computationally is proposed.

74 ATOMIC AND MOLECULAR PHYSICS↗

Direct Quantification of Heat Generation Due to Inelastic Scattering of Electrons Using a Nanocalorimeter

Transmission electron microscopy (TEM) is arguably the most important tool for atomic-scale material characterization. A significant portion of the energy of transmitted electrons is transferred to the material under study through inelastic scattering, causing inadvertent damage via ionization, radiolysis, and heating. In particular, heat generation complicates TEM observations as the local temperature can affect material properties. Here, the heat generation due to electron irradiation is quantified using both top-down and bottom-up approaches: direct temperature measurements using nanowatt calorimeters as well as the quantification of energy loss due to inelastic scattering events using electron energy loss spectroscopy. Combining both techniques, a microscopic model is developed for beam-induced heating and to identify the primary electron-to-heat conversion mechanism to be associated with valence electrons. Building on these results, the model provides guidelines to estimate temperature rise for general materials with reasonable accuracy. This study extends the ability to quantify thermal impact on materials down to the atomic scale.

42 ENGINEERING↗

Temperature-dependent Battery Performance of a Na 3 V 2 (PO 4 ) 2 F 3 @MWCNT Cathode and In-situ Heat Generation on Cycling

Excellent structural stability, high operating voltage, and high capacity have made Na 3 V 2 (PO 4 ) 2 F 3 a promising cathode material for sodium-ion batteries. However, high-temperature battery performances and heat generation measurements have not been systematically reported yet. Carbon-coated Na 3 V 2 (PO 4 ) 2 F 3 @MWCNT (multi-walled carbon nanotube) samples are fabricated by a hydrothermal-assisted sol-gel method and the electrochemical performances are evaluated at three different temperatures (25, 45, and 55 °C). Furthermore, the well-crystallized Na 3 V 2 (PO 4 ) 2 F 3 @MWCNT samples exhibit good cycling stability at both low and high temperatures; they deliver an initial discharge capacity of 120–125 mAhg -1 at a 1 C rate with a retention of 53 % capacity after 1,400 cycles with 99 % columbic efficiency. The half-cell delivers a capacity of 100 mAhg -1 even at a high rate of 10 C at room temperature. Furthermore, the Na 3 V 2 (PO 4 ) 2 F 3 @MWCNT samples show good long-term durability; the capacity loss is an average of 0.05 % per cycle at a 1 C rate at 55 °C. Additionally, ionic diffusivity and charge transfer resistance are evaluated as functions of state of charge, and they explain the high electrochemical performance of the Na 3 V 2 (PO 4 ) 2 F 3 @MWCNT samples. In-situ heat generation measurements reveal reversible results upon cycling owing to the high structural stability of the material. Excellent electrochemical performances are also demonstrated in the full-cell configuration with hard carbon as well as antimony Sb/C anodes.

25 ENERGY STORAGE↗