Engineering PapersSearch

SEARCH · Engineering Papers

Results for “heat exchangers”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Fluid to fluid contact heat exchanger

Heat transfer and pressure drop test results for a fluid to fluid contact heat exchanger are reported. The heat exchanger, fabricated and tested to demonstrate one method of transferring heat between structures in space, had a total contact area of 0.18 sq m. It utilized contact surfaces which were flexible and conformed to the mating contact surfaces upon pressurization of the fluid circulating within the heat exchanger. During proof-of-concept performance tests, the heat exchanger was operated in a typical earth environment. It demonstrated a contact conductance of 3.8 kW/sq m C at contact pressures in the 15 to 70 kPa range.

Clark, W. E.

Two-Phase Bidirectional Heat Exchanger

Heat exchanger transfers heat from one two-phase thermal loop to another. Condenses vapor in one loop while evaporating liquid in other. Transfers heat with very small drops in temperature and pressure, and efficiently joins heat pipes thermally without mixing of their working fluids. Several such heat exchangers used to build long, complex multiloop heat-control systems. Exchanger bidirectional: transfers heat in reverse, condensing on normally evaporating side, and vice versa. Can warm equipment it normally cools, without using auxiliary heater. In reverse transfer, wicks on evaporating side supply liquid continuously by capillary action; reverse-flow pump not needed. Design modified for other working fluids and larger heat-transfer rates.

Kroliczek, Edward

Compact, super heat exchanger

Heat exchanger uses porous media to enhance heat transfer through walls of cooling channels, thereby lowering wall temperature. Porous media within cooling channel increases internal surface area from which heat can be transferred to coolant. Comparison data shows wall has lower temperature and coolant has higher temperature when porous medium is used within heat exchanger. Media can be sintered powedered metal, metal fibers, woven wire layers, or any porous metal having desired permeability and porosity.

Fortini, A.

The water-cryogen heat exchanger

Heat exchanger, using water as heat medium, converts liquid hydrogen to gaseous hydrogen at a very high rate. Possible applications include treatment of liquified natural gas in cities to bring the gas on-line quickly, conversion of liquid oxygen and liquid nitrogen for steel mills, and high volume inert purging.

Bartlit, J. R.

High-Differential-Pressure Heat Exchanger

Heat exchanger accommodates large pressure difference between heat-transfer fluids. Designed so all welded joints inspected with x rays to ensure leak-free operation over many years. Joints between fluids and between each fluid and environment radiographically inspectable. Used in Stirling-cycle engines, including those in proposed nuclear and solar powerplants.

Hylin, Edward C.

Thermal energy storage heat exchanger: Molten salt heat exchanger design for utility power plants

The use of thermal energy storage (TES) in the latent heat of molten salts as a means of conserving fossil fuels and lowering the cost of electric power was evaluated. Public utility systems provided electric power on demand. This demand is generally maximum during late weekday afternoons, with considerably lower overnight and weekend loads. Typically, the average demand is only 60% to 80% of peak load. As peak load increases, the present practice is to purchase power from other grid facilities or to bring older less efficient fossil-fuel plants on line which increase the cost of electric power. The widespread use of oil-fired boilers, gas turbine and diesel equipment to meet peaking loads depletes our oil-based energy resources. Heat exchangers utilizing molten salts can be used to level the energy consumption curve. The study begins with a demand analysis and the consideration of several existing modern fossil-fuel and nuclear power plants for use as models. Salts are evaluated for thermodynamic, economic, corrosive, and safety characteristics. Heat exchanger concepts are explored and heat exchanger designs are conceived. Finally, the economics of TES conversions in existing plants and new construction is analyzed. The study concluded that TES is feasible in electric power generation. Substantial data are presented for TES design, and reference material for further investigation of techniques is included.

Ferarra, A.

"Bottle-Brush" Heat Exchanger

Heat exchanger consists of a metal tube with wires extending inward from wall. Conduction of heat along wires improves heat transfer to gas or other filling. Fluid is heated throughout the cross section of tube. Suggested applications are refrigerators, heat engines, thermal instrumentation, and heat switches.

Tward, E.

A Liquid-Liquid Thermoelectric Heat Exchanger as a Heat Pump for Testing Phase Change Material Heat Exchangers

The primary objective of the Phase Change HX payload on the International Space Station (ISS) is to test and demonstrate the viability and performance of Phase Change Material Heat Exchangers (PCM HX). The system was required to pump a working fluid through a PCM HX to promote the phase change material to freeze and thaw as expected on Orion's Multipurpose Crew Vehicle. Due to limitations on ISS's Internal Thermal Control System, a heat pump was needed on the Phase Change HX payload to help with reducing the working fluid's temperature to below 0degC (32degF). This paper will review the design and development of a TEC based liquid-liquid heat exchanger as a way to vary to fluid temperature for the freeze and thaw phase of the PCM HX. Specifically, the paper will review the design of custom coldplates and sizing for the required heat removal of the HX.

Sheth, Rubik B.

Evaluation of a Passive Heat Exchanger Based Cooling System for Fuel Cell Applications

Fuel cell cooling is conventionally performed with an actively controlled, dedicated coolant loop that exchanges heat with a separate external cooling loop. To simplify this system the concept of directly cooling a fuel cell utilizing a coolant loop with a regenerative heat exchanger to preheat the coolant entering the fuel cell with the coolant exiting the fuel cell was analyzed. The preheating is necessary to minimize the temperature difference across the fuel cell stack. This type of coolant system would minimize the controls needed on the coolant loop and provide a mostly passive means of cooling the fuel cell. The results indicate that an operating temperature of near or greater than 70 C is achievable with a heat exchanger effectiveness of around 90 percent. Of the heat exchanger types evaluated with the same type of fluid on the hot and cold side, a counter flow type heat exchanger would be required which has the possibility of achieving the required effectiveness. The number of heat transfer units required by the heat exchanger would be around 9 or greater. Although the analysis indicates the concept is feasible, the heat exchanger design would need to be developed and optimized for a specific fuel cell operation in order to achieve the high effectiveness value required.

Colozza, Anthony J.

Fluid insulation to prevent ice formation in heat exchangers

Heat transfer surfaces were insulated to maintain air side surface temperature above freezing. Double wall tubes, with annular space between tubes, were filled with static liquid hydrogen. Low thermal conductivity of this hydrogen provided thermal resistance.

Coffinberry, G. A.

Modular Heat Exchanger With Integral Heat Pipe

Modular heat exchanger with integral heat pipe transports heat from source to Stirling engine. Alternative to heat exchangers depending on integrities of thousands of brazed joints, contains only 40 brazed tubes.

Schreiber, Jeffrey G.

Experimental Investigation of Gas-Side Performance of a Compact Finned-Tube Heat Exchanger

Heat-transfer and pressure-drop data were obtained experimentally for the gas side of a liquid-metal to air, compact finned-tube heat exchanger. The heat exchanger was fabricated from 0.185-inch Inconel tubing in an inline array. The fins were made of 310 stainless-steel- clad copper with a total thickness of 0.010 inch, and the fin pitch was 15.3 fins per inch. The liquid used as the heating medium was sodium. The heat-exchanger inlet gas temperature was varied from 5100 to 1260 R by burning JP fuel for airflow rates of 0.4 to 10.5 pounds per second corresponding to an approximate Reynolds number range of 300 to 9000. The sodium inlet temperature was held at 1400 R with the exception of a few runs taken at 1700 and 1960 R. The maximum ratio of surface temperature to air bulk temperature was 1.45. Friction-factor data with heat transfer were best represented by a single line when the density and viscosity of Reynolds number were evaluated at the average film temperature. At the lower Reynolds numbers reported, the friction data with heat transfer plotted slightly above the friction data without heat transfer. The density of the friction factor was calculated at the average bulk temperature. Heat-transfer results of this investigation were correlated by evaluating the physical properties of air (specific heat, viscosity, and thermal conductivity) at the film temperature.

Gedeon, Louis

Microgravity condensing heat exchanger

A heat exchanger having a plurality of heat exchanging aluminum fins with hydrophilic condensing surfaces which are stacked and clamped between two cold plates. The cold plates are aligned radially along a plane extending through the axis of a cylindrical duct and hold the stacked and clamped portions of the heat exchanging fins along the axis of the cylindrical duct. The fins extend outwardly from the clamped portions along approximately radial planes. The spacing between fins is symmetric about the cold plates, and are somewhat more closely spaced as the angle they make with the cold plates approaches 90.degree.. Passageways extend through the fins between vertex spaces which provide capillary storage and communicate with passageways formed in the stacked and clamped portions of the fins, which communicate with water drains connected to a pump externally to the duct. Water with no entrained air is drawn from the capillary spaces.

Thomas, Christopher M.

Initial characterization of a modular heat exchanger with an integral heat pipe

As part of the Civil Space Technology Initiative (CSTI) Advanced Technology program, a conceptual design of the Stirling space engine (SSE) was generated. The overall goal of the CSTI high capacity power element is to develop the technology base needed to meet the long duration, high capacity power requirements for future NASA space missions. The free-piston Stirling engine (FPSE) was chosen as the growth option in the CSTI program. A major goal during the conceptual design of the SSE was to reduce the number of critical joints. One area of concern was the heat exchanger assemblies that typically have the majority of critical joints. The solution proposed in the SSE conceptual design used 40 modular heat exchangers. Each module has its own integral heat pipe to transport heat from the heat source to the engine. A demonstration of the modular concept was undertaken before committing to the detailed design of the SSE heat exchangers. An existing FPSE was modified as a test bed for modular heat exchanger evaluation. The engine incorporated three heat exchanger modules, each having a sodium filled heat pipe. The thermal loading of these modules was intended to be similar to the conditions projected for the SSE modules. The engine was assembled and tests are underway. The design and fabrication of the heat exchanger modules and the engine used for these tests were described. Evaluation of the individual heat pipes before installation in the engine is described. The initial test results with the modules in operation on the engine were presented. Future tests involving the engine were outlined.

Schreiber, Jeffrey G.

Utilization of Micro Tube Heat Exchanger for Next Generation Phase Change Material Heat Exchanger Development

Abstract and not the Final document is attached. Low Lunar orbit presents a unique thermal environment with high planetary and high solar IR requirements. Orion requires a phase change material heat exchanger (PCM HX) to act as a supplemental heat rejection device (SHReD) during this orbit. As a result, Orion currently uses a PCMHX to meet heat rejection demands in low lunar orbit. This PCM HX weighs 145 lbs, a significant amount of weight on the Crew Module Adaptor. To reduce this weight, a new PCM HX and phase change material is being proposed. This new PCM HX, constructed by Mezzo technologies, was originally designed as a water based PCM HX but is now be repurposed for phase change materials with transition temperatures in Orion's set points and different freeze front propagations. Mezzo's PCM HX utilizes micro tubes which greatly increase the overall heat transfer efficiency allowing for a compact design and significant weight savings. A new phase change material is also being proposed which has a higher latent heat of fusion as well as a higher density. This paper investigates the design, testing, and analysis done on the new Mezzo PCM HX as well as the corresponding phase change material.

Foley, Lauren A.