Depth and substrate dependence of heat dissipation in GaN p-n diodes bonded to AlN, diamond, and SiC
Explore the source record for details and available documents.
SEARCH · Engineering Papers
Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.
Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.
Explore the source record for details and available documents.
Explore the source record for details and available documents.
The growing use of artificial intelligence has led to heavy thermal loads and high heat dissipation rates in data centers. Conventional air-cooled technologies are not able to fulfill these requirements. To overcome these challenges, two-phase immersion cooling (2PIC) has emerged as one of the leading technologies for high power-density chips. 2PIC increases the heat dissipation rate and efficiency of the system while reducing the footprint of the cooling equipment. A fluid with adequate dielectric properties, a suitable normal boiling temperature to maintain chip temperatures, and good material compatibility, is desired for 2PIC system. In this study, the pool boiling heat transfer of a new developmental dielectric fluid, Opteon™ 2P50, was experimentally investigated. The heat transfer coefficients at various heat fluxes (20–150 kW/m 2 ) and the critical heat flux were measured using a smooth aluminum surface. Compared with HFE-7100, Opteon™ 2P50 shows higher heat transfer coefficient (up to 59% higher) and a slightly lower value of critical heat flux (around 5.9% lower). The modified Cooper correlation with the optimized leading constant resulted in reliable prediction accuracy with a 5.3% mean absolute error percentage. Overall, these results indicate that the new dielectric fluid provides similar thermal performance to some legacy fluids.
Semiconductor nanocrystals (NCs) offer actualized and prospective utility in optoelectronic technologies, yet key aspects of their thermal and vibrational behaviors remain unresolved. Compared with bulk crystals, heat dissipation involving NCs can differ substantially owing to pervasiveness of interfacial scattering, phonon confinement, and relaxed phonon momentum selection rules, as well as influences of ligands. Here, in addition to transient absorption, we use femtosecond stimulated Raman spectroscopy to track nonequilibrium optical-phonon dynamics in InP NCs capped with myristic acid ligands and compare the same particles coated with a ZnS shell. We identify distinct phonon decay pathways in ligand-capped versus ZnS-shelled NCs. Increasing the excitation density and introducing the ZnS shell measurably modify optical-phonon lifetimes, whereas phonon formation times remain largely unchanged. In addition, we observe phonon mode softening in ligand-capped nanocrystals, consistent with lattice expansion. Together, these results demonstrate that core–shell structures can strongly govern nanocrystal thermal dissipation pathways and should be considered a key design parameter for optoelectronic operation.
Climate change is reshaping ecosystems, driving plants to adapt through leaf-trait plasticity that reflects strategies for growth and water use. Predicting biomass production and intrinsic water use efficiency (iWUE) remains challenging because of genetic, taxonomic, and environmental variability. Here, we used eastern cottonwood and Populus hybrids as a model system to test whether easily measurable leaf traits can serve as reliable predictors of performance, and whether adding stomatal and biochemical traits improves predictive power. Across two field sites in Mississippi, leaf mass per area (LMA), biomass production, iWUE, leaf area, and foliar nitrogen ( N %) differed significantly among taxa and sites, while other traits were conserved. Factorial analysis of mixed data (FAMD) revealed distinct clustering of taxa and sites, indicating coordinated variation among leaf and stomatal traits. Pairwise correlations highlighted fundamental trade-offs, with biomass positively related to LMA and petiole length but negatively associated with iWUE, N %, and carbon isotopic ratios (δ 13 C). Leaf temperature and leaf angle varied among taxa and were significantly correlated with LMA and petiole length, suggesting mechanisms of heat dissipation and leaf movability that link simple traits to gas exchange and productivity. Weighted multiple linear regression models explained 80%–91% of variation in biomass production and iWUE. Models using only LMA, petiole length, and stomatal metrics performed nearly as well as those incorporating N %, and δ 13 C, with complex traits adding approximately 10% explanatory power. These results demonstrate that simple morphological traits capture integrated functional trade-offs, while complex traits refine predictions. This tiered approach provides an efficient framework for selecting high-yielding, water-efficient genotypes of Populus and other hardwood species, offering practical pathways to enhance carbon uptake and iWUE under climate change.
To model the temperature evolution of optically thin astrophysical environments at MHD scales, radiative and collisional cooling rates are typically either pretabulated or fit into a functional form and then input into MHD codes as a radiative loss function. Thermal balance requires estimates of the analogous heating rates, which are harder to calculate, and due to uncertainties in the underlying dissipative heating processes these rates are often simply parameterized. The resulting net cooling function defines an equilibrium curve that varies with density and temperature. Such cooling functions can make the gas prone to thermal instability (TI), which will cause departures from equilibrium. There has been no systematic study of thermally unstable parameter space for nonequilibrium states. Motivated by our recent finding that there is a related linear instability, catastrophic cooling instability, that can dominate over TI, here we carry out such a study. We show that Balbus instability criteria for TI can be used to define a critical cooling rate, Λ c , that permits a nonequilibrium analysis of cooling functions through the mapping of TI zones. We furthermore illustrate how thermal conduction modifies the shape of TI zones. Upon applying a Λ c -based stability analysis to coronal loop simulations, we find that loops undergoing periodic episodes of coronal rain formation are linearly unstable to catastrophic cooling instability, while TI is stabilized by thermal conduction.
Thermal comfort during space flight is discussed. Heat production of man during space flight and wear loss as a mean of dissipating heat are described. Water cooled garments are also considered, along with tolerance for extreme heat and body heat storage. Models of human temperature regulation are presented in the form of documented FORTRAN programs.
To model the temperature evolution of optically thin astrophysical environments at MHD scales, radiative and collisional cooling rates are typically either pretabulated or fit into a functional form and then input into MHD codes as a radiative loss function. Thermal balance requires estimates of the analogous heating rates, which are harder to calculate, and due to uncertainties in the underlying dissipative heating processes these rates are often simply parameterized. The resulting net cooling function defines an equilibrium curve that varies with density and temperature. Such cooling functions can make the gas prone to thermal instability (TI), which will cause departures from equilibrium. There has been no systematic study of thermally unstable parameter space for nonequilibrium states. Motivated by our recent finding that there is a related linear instability, catastrophic cooling instability, that can dominate over TI, here we carry out such a study. We show that Balbus instability criteria for TI can be used to define a critical cooling rate, Λc, that permits a nonequilibrium analysis of cooling functions through the mapping of TI zones. We furthermore illustrate how thermal conduction modifies the shape of TI zones. Upon applying a Λc-based stability analysis to coronal loop simulations, we find that loops undergoing periodic episodes of coronal rain formation are linearly unstable to catastrophic cooling instability, while TI is stabilized by thermal conduction.
NASA seeks to demonstrate a path for achieving safe, high power, and high performing Li-ion battery designs for the purpose of establishing design guidelines for our aeronautic and spacecraft applications. Safe means passively resistant to thermal runaway propagation of any single cell catastrophic thermal runaway. High power means capable of 3C continuous discharge without overheating. High performing means achieving > 160 Wh/kg, 200 Wh/L. The biggest challenge has been balancing a high flux light weight path for cell heat dissipation during the high rate discharge that minimizes thermal gradients between cells and also protects adjacent cells from the heat load of thermal runaway cell. Our solution includes an oscillating heat pipe spine that contacts every 18650 cell in the pack and careful cell design selection to maximize the range of initial temperatures conditions where the battery can safely complete the 3C discharge.
Ultrafast and nanoscale heat conduction demands a unified theoretical framework that rigorously bridges macroscopic transport equations with microscopic material properties derived from statistical physics. Existing empirical generalizations of Fourier's law often lack a solid microscopic foundation, failing to connect observed non-Fourier behavior with underlying atomic-scale mechanisms. In this work, we present a time-domain theory of transient heat conduction rooted in Zwanzig's statistical theory of irreversible processes. Central to this framework is the time-domain transport function $\overleftrightarrow{𝑍}$(𝑡) defined through equilibrium time-correlation functions of heat fluxes. This function generalizes the conventional concept of steady-state thermal conductivity, governing the transition of conduction dynamics from onset second sound type wave propagation at finite speeds to diffusion-dominated behavior across broad temporal and spatial scales. Unlike phonon hydrodynamic models that rely on mesoscopic constructs such as phonon drift velocity, our approach provides a quantitative and microscopic description of intrinsic memory effects in transient heat fluxes and applies universally to bulk materials at any temperature or length scale. By integrating atomistic-scale first-principles calculations with continuum-level macroscopic equations, this framework offers a robust foundation for numerical simulations of transient temperature fields. Furthermore, it facilitates the interpretation and design of transient thermal grating experiments using nanometer-scale heat sources and ultrafast laser systems in the extreme ultraviolet and x-ray wavelength ranges, advancing our understanding of heat dissipation dynamics.
Clothes drying is among the most power-intensive household end uses, and vapor compression-based clothes dryers offer substantial energy cost savings compared with conventional electric heater dryers. However, parasitic heat losses along the air path, that is, heat loss at the upstream of the drum, inside the drum, and at downstream of the drum, remain rarely quantified, but can strongly affect overall performance according to experiments. Here, this study enhances a vapor compression simulation model by integrating a validated drum model using a dimensionless heat-and-mass-transfer effectiveness correlation derived from 63 drying tests in the literature to form a quasi-steady dryer simulation model. The model is validated against laboratory measurements of a baseline dryer. The impact of heat losses is simulated at three locations and explored through 16 heat loss cases spanning two loads (2 and 5 kg), two airflow rates, and multiple loss distributions. For a 5 kg wet load, eliminating pre-drum and in-drum losses reduces total energy use by up to 34–35% and shortens drying time by 27–38% compared with the baseline. At a 2 kg wet load, introducing post-drum heat loss lowers energy costs by up to 23% and reduces operation time by up to 57% compared with the baseline. The results demonstrate that the impact of heat loss is location dependent. Vapor compression dryers should minimize pre-drum and in-drum losses while potentially exploiting post-drum heat dissipation to enhance the drying rate and energy cost savings.
Rapid growth in artificial intelligence and data center workloads demands high-performance liquid cooling to manage increasing chip power. This study presents two metal-additive-manufactured cold plates with sinusoidal fins, constant-amplitude wavy fins and linearly variable-amplitude wavy fins and compares them against metal-additive-manufactured straight fins using experiments conducted at 1 kW heat dissipation as well as high-fidelity 3D conjugate computational fluid dynamic simulations. The cold plates were printed in AlSi10Mg material and underwent design using a Python-automated workflow prior to manufacture and testing. The experiments show that wavy fins reduce the normalized thermal resistance by 35 to 45 % at water flow rates from 1 to 4 LPM. At a fixed 20 kPa pressure drop, the variable-waviness design lowered peak surface temperature by 9 °C and thermal resistance by 51 %, while edge-channel maldistribution in the constant wavy fin design limited gains. A thermal resistance breakdown revealed that 55–63 % of the total thermal resistance in wavy designs comes from base heat conduction, 27–33 % from fin heat conduction, and 9–13 % from fin heat convection, indicating the need to address conduction bottlenecks. Parametric sweeps identify a 3 mm fin pitch as optimal, and that horizontal inlet/outlet manifolds further reduce pressure drop by 30–60 % and thermal resistance by 9–16 % relative to vertical inlet-outlet manifolds. The results yield comprehensive guidelines for fin geometry, manifold alignment, material selection and additive-manufacturing constraints to realize high-performance liquid-cooled cold plates for power-dense electronics.
For batteries to function effectively all active material must be accessible requiring both electron and ion transport to each particle. A common approach to generating the needed conductive network is the addition of carbon to create a composite electrode. An alternative approach is the electrochemically induced formation of conductive reaction products where the electrochemically generated materials are in intimate contact with the active material contributing to effective connection of each active particle. Furthermore, this study probes silver vanadium oxide (Ag 2 V 4 O 11 , SVO), carbon monofluoride (CF x ), and hybrid SVO/CF x electrodes in lithium batteries. Ex situ XRD identifies Ag 0 as a reduction product from SVO and LiF from CF x that can be followed as a function of depth-of-discharge (DOD). Spatially-resolved operando energy dispersive x-ray diffraction reveals that the presence of SVO alleviates reaction heterogeneity in the electrodes which are electron transfer limited in the absence of sufficient Ag 0 . Synchrotron X-ray tomography on discharged cathodes reveals the distribution of silver particles where the particles are more closely spaced near the current collector indicating multiple nucleation sites for their formation. Finally, operando isothermal microcalorimetry is used to determine the heat dissipation of the parent and hybrid battery types. Using material enthalpy potentials, we determine the current distribution between the two active materials for the discharging hybrid cathode adding further insight to the diffraction analysis. Taken together, these results provide a comprehensive understanding of hybrid SVO/CF x cathodes and give guidance on optimal compositions that balance power and energy density considerations.
We study single Cu-on-Cu impacts relevant to cold spray deposition and quantitatively analyze the metadynamic recrystallization (mDRX) that takes place after the impact by virtue of lingering impact adiabatic heat. Unlike prior studies, the current full 3D tomographic analysis of the mDRX volume shows that mDRX is extremely common in such impacts, although it is often missed when examining 2D sections. We also report an unexpected trend: there is a “sour spot” for mDRX at velocities about 20–40 % above the velocity for particle adhesion. This non-monotonic trend is contrary to the expectations based on increasing adiabatic heating with velocity. With a schematic model, we show that the trend can be explained on the basis of heat transfer: cooling of the heat-affected region is limited by transport through the bonded regions at the particle-substrate interface. Thus, bonding has a prominent role in the heat dissipation process and the best bonded particles most rapidly bulk quench, avoiding mDRX. Here, the developed semi-empirical model aligns with the experimental findings and may help inform microstructural evolution during cold spray and post-spray processing.
Accident Tolerant Fuels (ATFs) are designed to increase coping time following an accident scenario while preserving or improving current steady state reactor operational performance. A potential ATF concept is SiC-SiC composite claddings. Fuel performance simulations were conducted on a SiC-SiC based cladding concept utilizing a multilayered approach for improved performance. This cladding concept referred to as the Duplex concept is a duplex structure composed of a monolithic SiC layer placed on the outside of a SiC-SiC composite. A liquid metal is added to fuel-cladding gap for improved heat dissipation from the fuel. The monolithic SiC layer is used to improve the coolant corrosion characteristics and protect the SiC-SiC composite layer from exposure to the coolant. The fuel performance code BISON was used to conduct fuel performance simulations on the cladding concepts. Comparisons are made with a current prototypic fuel rod design (UO 2 fuel enclosed in Zircaloy-4 cladding). Representative steady-state cases were considered for normal power and two cycle power histories. Additionally, a PCI ramp case was simulated to analyze potential anticipated operational occurrences. Transient response during a Loss of Coolant Accident and a Reactivity Initiated Accident were also simulated. This computational study demonstrated that for normal operating conditions, the SiC concept cladding performed as well as the baseline for the standard power cases evaluated. The ramping evaluations indicate potential fracturing of the SiC-SiC composite of the composite cladding compared to the Zircaloy-4 cladding due to the temperature gradient and the subsequent differential thermal conductivity degradation and swelling across the composite thickness. In conclusion, the rod fails early at low enthalpy for RIA but survives a LOCA with minimal material loss due to high temperature steam corrosion.
This study evaluates the effectiveness of various urban heat island (UHI) overheating mitigation strategies and their associated impacts on urban cloud dynamics and thermal processes. This study shows cloud-resolving and urban-resolving modeling results estimating the impact of Houston-Galveston heat mitigation scenarios and other resilient strategies contemplated in the Climate Adaptation Plan and Resilient Houston reports. The simulated scenarios include high intensity green rooftops, rooftop photovoltaic solar panels, enhanced urban irrigation, white/cool roofs and roads, and street trees. We contrast the adaptation scenarios against a present baseline case, a no city scenario and a larger and denser city as projected by the Houston-Galveston Area Council for 2045. During the daytime, cooling strategies such as cool roofs, cool roads, and green roofs exhibit superior performance in mitigating urban overheating. At night, enhanced urban irrigation emerges as the most effective cooling intervention. Cooling strategies significantly reduce sensible heat flux partitioning during the day, a process that reduces the uplift of air, suppressing the formation of urban shallow cumulus clouds. The extent of urban cloud mixing ratio is reduced in proportion to the decrease in sensible heating. Under the BEP-Tree scenario, which includes wind effects and evapotranspiration driven by a stomatal conductance model, urban trees demonstrated negligible environmental cooling effects and minimal urban cloud modifications. In contrast, the scenarios with more urban cooling and higher latent heat fluxes led to suppressed urban clouds. The net cooling effect achieved by the heat mitigation strategies is influenced by a combination of indirect processes, including the reduction of downwelling longwave radiation flux, due to reduced cloud presence, while some warming is attributed to a modest increase in shortwave radiation that offsets the cooling benefit. Additionally, reduced heat dissipation, weakened thermal gradients, and diminished vertical mixing over urban areas further moderate the cooling potential. These findings highlight the pivotal role of clouds and moist atmospheric processes in shaping the UHI effect and offer insights for designing more effective urban cooling strategies.
In one of the leading theories for the origin of the solar wind, photospheric motions launch Alfvén waves (AWs) that propagate along open magnetic-field lines through the solar atmosphere and into the solar wind. The radial variation in the Alfvén speed causes some of the AWs to reflect, and counter-propagating AWs subsequently interact to produce Alfveńic turbulence, in which AW energy cascades from long wavelengths to short wavelengths and dissipates, heating the plasma. In this paper we develop a one-dimensional two-fluid solar-wind model that includes Alfvénic turbulence, proton temperature anisotropy and a novel method for apportioning the turbulent heating rate between parallel proton heating, perpendicular proton heating and electron heating. We employ a turbulence model that accounts for recent observations from NASA’s Parker Solar Probe, which find that AW fluctuations in the near-Sun solar wind are intermittent and less anisotropic than in previous models of anisotropic magnetohydrodynamic turbulence. Our solar-wind model reproduces a wide range of remote observations of the corona and in-situ measurements of the solar wind, and our turbulent heating model consists of analytic equations that could be usefully incorporated into other solar-wind models and numerical models of more distant astrophysical plasmas.
The generation and dissipation of heat in nanocrystals upon optical excitation is a process which may either limit or enhance their performance in certain applications. Using transient absorption spectroscopy, we tracked the flow of heat from plasmonic tin-doped indium oxide (ITO) nanocrystals to surface adsorbed perylenediimide (PDI) molecules upon excitation of the ITO near-infrared plasmon resonance. Here, we rationalize the derivative line shapes observed in the transient absorption bleach features are the result of thermal transfer from the ITO core to surface ligands based on temperature-dependent static absorption studies of the PDI molecules adsorbed on plasmonic ITO. Through a series of pump power dependent measurements, we demonstrate that the PDI heating time is largely fluence independent at the powers measured, while the overall recovery time increases. Elucidating thermal transfer rates at the nanocrystal and organic ligand interface is key for applications such as plasmon mediated photocatalysis, where heating may obfuscate hot carrier transfer processes.