Engineering PapersSearch

SEARCH · Engineering Papers

Results for “hardware-in-the-loop”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Balance of Plant Modeling and Real-Time Hardware-in-the-Loop Integration with the Microreactor Automated Control System

The advent of novel microreactor technology has driven a focused effort to explore safety and efficiency improvements that can be achieved through the use of automated system control. Development of control strategies, especially for initial demonstration, requires an adequate surrogate environment to safely research failure modes and control integration with realistic hardware delay. However, efficiency gains from control strategies are improved when the scope of controller action is expanded to include system-level dynamics such as downstream heat extraction and mass flow. For this reason, a balance-of-plant (BOP) model of a representative microreactor system has been developed using the TRANsient Simulation Framework of Reconfigurable Models library in Modelica. This model captures a reactor and primary NaK coolant loop that represent corresponding system components of the Microreactor Applications Research Validation and EvaLuation (MARVEL) design as well as a secondary coolant loop and heat extraction representative of the Microreactor Agile Non-Nuclear Experimental Test Bed (MAGNET). This model configuration allows for hardware-in-the-loop (HIL) integration with microreactor automated control system (MACS) hardware in real time through a Python-based gRPC client. Real-time simulation of model performance with emulated hardware and communication delay suggests that under independent proportional-integral-derivative control of BOP model drum dynamics and downstream heat extraction, stable power load following is achievable. A slight delay in load following, filtering of high-frequency dynamics, and localized temperature fluctation suggest room for improvement through the development of higher-level control strategies. The simulated coupling of the MAGNET facility lays the groundwork for future digital twin analysis with a coupled MACS-MAGNET HIL demonstration.

McConnell, Jono [ORNL] (ORCID:0000000238984741)

Subscale Hardware-In-The-Loop Results for Hybrid Electric Turbofan Controls Use Cases

NASA is investigating hybrid electric turbine engine systems for commercial transport aircraft due to the potentially significant improvements hybrid electric technology offers in performance, fuel consumption, and operational and design flexibility. Recently, the technology has been tested at full scale in partnership with industry and advanced to Technology Readiness Level 4. This presentation will focus on a recent subscale hardware-in-the-loop test of an open source turbofan engine model developed by NASA. The Advanced Geared Turbofan 30,000 lbf – electrified (AGTF30-e) engine is used as a reference model to demonstrate control system design and use cases for an example mild hybrid electric system with no large-scale energy storage. This model is run in real-time in NASA’s Hybrid Propulsion Emulation Rig (HyPER) and is used to drive an emulation of the turbomachinery system using subscale electric machines. This dynamic scaled shaft emulation interacts with a subscale (<100 kW) hybrid system consisting of electric machines, motor controllers, and a programmable electronic load. Specific use cases demonstrated include the use of Turbine Electrified Energy Management to improve operation during transients, megawatt-scale power extraction from the AGTF30-e, and power transfer between engine spools. Results related to the effectiveness of hybrid systems are qualitatively compared to results from industry testing.

Hybrid

Integrated Hydrogen Energy System Testing/Validation: Cooperative Research and Development Final Report, CRADA Number CRD-21-18272

Through the ARIES platform, this proposed project aims to bridge a gap and utilize the power hardware-in-the-loop (PHIL) and controller hardware-in-the-loop (CHIL) experiments and create open-source interconnection and interoperability information that can aid in faster and cheaper installation and operation of grid forming fuel cell inverters.

08 HYDROGEN

Hybrid Dynamic Modeling of Smart Inverter

This letter proposes a novel hybrid method for assessing grid-connected three-phase converter interfaced resources (CIR) dynamics with the IEEE standard 1547-2018 grid support functions (GSFs), which blends physics and data-driven techniques. First, the letter derives an analytical model of a CIR to represent the internal physics and data-driven model (DDM) using a system identification algorithm to represent the rest of the dynamics, including the GSF. The derived hybrid model combines the analytical model of CIR and DDM, which balances accuracy and flexibility and is compared with the detailed switched model. Furthermore, the efficacy of the proposed approach to represent the advanced CIR dynamics is substantiated by power hardware-in-the-loop experiment data where real measurements from a commercial CIR are used to cross-validate the proposed approach. Furthermore, the results indicate that despite simple, the hybrid model accurately reproduces the dynamics of the detailed CIR model with an acceptable accuracy.

Data-driven model

From observation to replication: machine-learning-driven quantification and replication of fine-scale fish kinematics and behavior

Long-term quantification of fish behavior is essential for aquatic ecology, wildlife telemetry, and biomechanical device development. However, the observation duration required to obtain reliable behavioral and kinematic metrics remains unclear, and few tools exist to physically reproduce natural swimming motion for controlled experimentation. We address these challenges by developing a generalizable framework that models behavioral reliability (Spearman–Brown reliability index) as a function of observation duration and derives metric-specific monitoring thresholds. Using juvenile white sturgeon (Acipenser transmontanus) as a case study, we demonstrate that the minimum duration needed for reliable estimates varies substantially across kinematic features: to exceed a reliability of 0.8, total distance traveled requires 12 days, average curvature (mm?¹) 15 days, tail-beat frequency (Hz) 8 days, and average speed (body length/s) 17 days. We further bridge digital analysis and physical testing by developing a hardware-in-the-loop simulator that reconstructs machine-learning-derived swimming kinematics with high fidelity (correlation coefficient 0.98–0.99, RMSE 1.22–1.27 mm over a 5-minute segment). This platform enables realistic, repeatable motion stimuli for evaluating aquatic sensing technologies and bio-integrated devices under controlled conditions. Together, these contributions provide a scalable approach for designing long-term behavioral studies and a data-driven connection between ecological observation and robotic experimentation.

Hwang, SungJoo

Hydrogen Production System Scaling Using a High-Fidelity Simulation-Optimization Framework

Proton exchange membrane (PEM) electrolyzers are widely used for hydrogen production, yet few validated, high-fidelity tools can reliably guide scale-up. Using measured performance from a 50-hour hardware-in-the-loop pilot test, a physics-based, plant-level model of a 1.25 MW PEM electrolyzer and its balance-of-plant (BoP) subsystems is developed and validated. The model couples electrochemistry and thermal/flow submodels and is calibrated against pilot test data via a genetic algorithm (GA) workflow. Validation yields a mean absolute percentage error (APE) of 0.43% for cell voltage and stack power. Two scale-out strategies are then benchmarked under a common 7-day wind-and-photovoltaic (PV) profile: (i) linear duplication of 1.25 MW blocks and (ii) shared-BoP architectures. Sharing BoP between stacks reduces BoP energy by 27% at 10 MW and 34% at 100 MW (vs. linear duplication) and improves system specific energy consumption (SEC) to 52.9 and 52.6 kWh/kg, respectively (from 54.0 kWh/kg with linear duplication). Partial-load studies (25-100% set-point) show that cumulative hydrogen production remains nearly constant down to 50% load because all cases use the same weekly renewable-energy input. Below 50%, the power cap limits how much energy can be used within 168 h, which reduces hydrogen output. The model further indicates that the practical operating optimum lies between 50% and 85% load, where efficiency gains begin to appear without significant loss in hydrogen output. Moreover, the efficiency gains at lower loads are offset by reduced production. The validated framework supports scenario-based engineering trade-off studies for large configurations (10-100 MW) and for operating policies under variable renewables.

08 HYDROGEN

A Novel Protection Scheme for Unbalanced Faults in Inverter Dominated Networks: A Computationally Efficient Algorithm for Entry-Level Relays

Microgrids are now a common practice in distribution systems to increase resilience and reliability. However, microgrid protection remains a critical challenge, considering its requirement to operate in both grid connected and islanded, and the variability in fault characteristics under each mode of operation. This paper presents unbalanced power (S unb ) based fault detection algorithm, which considers local voltage and current unbalances to determine faults in the system. S unb is a computationally efficient fault detection algorithm that is suitable for implementation in the programmable logic of entry level protective relays. In addition, the difference in current and voltage unbalance (D n ) is used to determine the fault type. The proposed method demonstrates high sensitivity and selectivity for line-to-ground (LG), line-to-line (LL), and double line-to-ground (LLG) faults, representing the most common faults in distribution systems. It also allows relay coordination with upstream and downstream protection devices in both island and grid connected operation, while preserving grading margins. The same pickup and time multiplier settings of a particular relay for both modes of operation eliminates the need for adaptive settings, which rely on communication networks. Validation was performed with a hardware-in-the-loop (HIL) setup using Typhoon HIL real time simulator interfaced with three entry-level, SEL 751 relays. Results confirmed the algorithm’s ability to discriminate fault conditions, and determine the fault type under both operating modes, maintain fast detection times, and ensure proper protection coordination.

fault classification

NeuroCoreX: An Open-Source FPGA-Based Spiking Neural Network Emulator with On-Chip Learning

Spiking Neural Networks (SNNs) are computational models inspired by the event-driven communication and connectivity patterns of biological neural circuits. They enable high energy efficiency and natural support for diverse architectures ranging from layered networks to small-world and graphstructured topologies. In this work, we introduce NeuroCoreX, an open-source, FPGA-based spiking neural network emulator that provides real-time, on-chip learning and flexible network organization. NeuroCoreX supports both feedforward sensory inputs streamed directly from sensors or PCs via UART and recurrent on-chip connectivity, enabling simultaneous processing and learning from external stimuli and internal network dynamics-capabilities rarely available in existing FPGA SNN platforms. The system implements a Leaky Integrate-and-Fire (LIF) neuron model with current-based synapses and supports pair-based STDP learning on both feedforward and recurrent synapses. A lightweight Python interface enables interactive configuration, live monitoring, weight read-back, and experiment control. Importantly, NeuroCoreX is tightly integrated with the SuperNeuroMAT simulator, allowing SNN models to be transferred seamlessly from software to hardware for hardware-in-the-loop development. By combining real-time plasticity, flexible connectivity, and an open-source VHDL implementation, NeuroCoreX provides an extensible and accessible platform for neuromorphic research, algorithm-hardware co-design, and energy-efficient edge intelligence.

Gautam, Ashish [ORNL]

SDN-Based Dynamic Cybersecurity Framework of IEC-61850 Communications in Smart Grid

In recent years, critical infrastructure and power grids have experienced a series of cyber-attacks, leading to temporary, widespread blackouts of considerable magnitude. Since most substations are unmanned and have limited physical security protection, cyber breaches into power grid substations present a risk. Nowadays, the susceptibility of SDN architecture to cyber-attacks has exhibited a notable increase in recent years, as indicated by research findings. This suggests a growing concern regarding the potential for cybersecurity breaches within the SDN framework. In this paper, we propose a hybrid intrusion detection system (IDS)-integrated SDN architecture for detecting and preventing the injection of malicious IEC 61850-based generic object-oriented system event (GOOSE) messages in a digital substation. Additionally, this program locates the fault’s location and, as a form of mitigation, disables a certain port. Furthermore, implementation examples are demonstrated and verified using a hardware-in-the-loop (HIL) testbed that mimics the functioning of a digital substation.

Liu, Chen-Ching [Virginia Tech] (ORCID:00000002894

SDN-Based Smart Cyber Switching (SCS) for Cyber Restoration of a Digital Substation

In recent years, critical infrastructure and power grids have increasingly been targets of cyber-attacks, causing widespread and extended blackouts. Digital substations are particularly vulnerable to such cyber incursions, jeopardizing grid stability. This paper addresses these risks by proposing a cybersecurity framework that leverages software-defined networking (SDN) to bolster the resilience of substations based on the IEC- 61850 standard. The research introduces a strategy involving smart cyber switching (SCS) for mitigation and concurrent intelligent electronic device (CIED) for restoration, ensuring ongoing operational integrity and cybersecurity within a substation. The SCS framework improves the physical network’s behavior (i.e., leveraging commercial SDN capabilities) by incorporating an adaptive port controller (APC) module for dynamic port management and an intrusion detection system (IDS) to detect and counteract malicious IEC-61850-based sampled value (SV) and generic object-oriented system event (GOOSE) messages within the substation’s communication network. The framework’s effectiveness is validated through comprehensive simulations and a hardware-in-the-loop (HIL) testbed, demonstrating its ability to sustain substation operations during cyber-attacks and significantly improve the overall resilience of the power grid.

Liu, Chen-Ching (ORCID:0000000289417958)

Secure Time Synchronization in Power Grids and Network HIL Synchrophasor Testing

Reliable and secure time synchronization underpins the monitoring and control functions of modern power grids. As GPS-based timing infrastructures grow more susceptible to spoofing and jamming, their vulnerabilities pose escalating risks to grid stability. This work investigates a secure, resilient timing framework that can serve as an alternative or redundant source for power grids, with a particular focus on synchrophasorbased applications. A candidate timing system architecture is evaluated to guarantee trustworthy time dissemination, even in degraded conditions. A network hardware-in-the-loop testing of two synchrophasors validates the concepts, demonstrating enhanced timing integrity, improved detection of timing anomalies, and sustained observability during adverse timing events.

Wu, Ori [ORNL] (ORCID:0000000326723410)

Demonstration of Grid Services Using Mixed Grid-Forming and Grid-Following Technologies at the Wheatridge Renewable Energy Facility (Final Technical Report)

This Final Technical Report summarizes the analytical, modeling, and engineering work performed to evaluate grid-forming (GFM) inverter capabilities within a large hybrid renewable energy facility. The project focused on assessing the ability of advanced inverter-based resources to provide essential reliability services through coordinated operation of grid-forming (GFM) and grid-following (GFL) technologies. During Budget Period 1, the project developed a comprehensive framework of GFM performance metrics, including angle support, voltage regulation, frequency response, damping behavior, and current-limiting performance. Extensive electromagnetic transient (EMT) studies and hardware-in-the-loop (HIL) testing were conducted to validate GFM behavior under a range of operating conditions, including weak-grid scenarios, voltage disturbances, and multi-resource interactions. The project also established validated modeling approaches, plant-level control integration strategies, commissioning frameworks, and high-speed measurement infrastructure to support future field demonstration. Although the project concluded prior to field demonstration, the results provide a utility-scale foundation for evaluating, modeling, and deploying grid-forming technologies. The methodologies and tools developed contribute to industry understanding of inverter-based resource behavior and support future power system reliability under increasing renewable penetration.

14 SOLAR ENERGY

Community Resilience Through Rapid Restoration Leveraging Distributed Energy Resources (DERs) and Low-Cost Sensors

Equitable and automated bottoms-up power restoration following an extreme event will be demonstrated at a site in Puerto Rico. To do so, the team will develop enhanced grid situational awareness techniques integrating behind-the-meter (BTM) distributed energy resources (DER) discovery, impedance sweeping based outage boundary detection, and feasible restoration path identification algorithms. Resilience metric will be developed and incorporated along with situational awareness information in a distributed Model Predictive Control (MPC)-based restoration optimization algorithm to control and mobilize grid assets. These algorithms will be validated through power hardware-in-the-loop experiments and ultimately, a site demonstration to show that outage recovery time and total recovered load could be improved by >20% over the baseline.

24 POWER TRANSMISSION AND DISTRIBUTION

Flight Testing

It is considered by the Flight Mechanics Panel of AGARD as vitally important that the NATO flight test community meet regularly so that new techniques for flight test, instrumentation and data analysis and lessons learned from past and on-going programs be disseminated to ensure that safe efficient cost-effective and timely testing is accomplished. There are many new systems being tested or planned for testing in the near future. These include programmable signal processor radars, integrated flight, fire and propulsion control systems, thrust vectoring, low observable technologies, multifunction pilot displays and multisensor integration. Acquisition and processing of large quantities of avionics multiplex data are challenges that must be met. There is a need for greater use of simulators and other hardware-in-the-loop ground test facilities.

Source record

Controls for Electrified Aircraft Propulsion

Advanced electrified aircraft propulsion (EAP) concepts with integrated power, propulsion, and thermal systems require the development of equally sophisticated controllers to fly safe and efficient missions. Hybrid electric aircraft utilize electric machines mechanically coupled to the engine shafts to extract and insert power for a variety of purposes. Additionally, electric machines may drive propulsive fans pulling from a combination of on-board energy storage devices and engine extracted power. NASA’s investment in hybrid electric aircraft hardware-in-the-loop testing enables controls research on representative engine models using a novel emulation and scaling methodology. High-voltage, high-power electrical powertrain presents several technical risks at altitude. High-power requires high efficiency to minimize losses. Superconducting electric machines and power distribution research at NASA has identified key challenges with potential controls solutions. These risks necessitate the development of controllers robust to model uncertainty, disturbances, and fault conditions. System health management and fault detection schemes play an important role in a multi-layer controls approach that utilizes a supervisor which oversees inner loops for the highly coupled power, propulsion, and thermal systems. Such a supervisory controller enables coordinates energy transfer between engines, energy storage devices, electric machines, propulsors, and heat exchangers. Existing methods have shown an improvement in engine operability using the hybrid electric powertrain.

Halle E Buescher

Energy Systems Integration Facility Stewardship Summary: Fiscal Year 2025

A summary of NLR's stewardship of the nationally unique Energy Systems Integration Facility (ESIF) highlighting performance metrics, capability upgrades, and examples of R&D impact. 2025 brought a national focus on energy and ESIF is meeting the moment. All eyes are on data centers and domestic manufacturing and bringing the benefits of artificial intelligence to power system planning and operations. In step with national priorities, ESIF is building out capabilities that advance secure, reliable, and affordable power. ESIF hosted 190 multidisciplinary research projects, 855 high-performance computer users, and collaborated with 81 partners from industry, academia, research, and federal agencies. These research projects resulted in an AI method for detecting high-impedance faults with 90% accuracy, a grid controls demonstration in Connecticut, power quality validation of CorePower's flagship inductor, and a cybersecurity assessment of potential rogue capabilities in digitally connected energy devices. Facility infrastructure improvements enhanced the thermal research network, the SCADA system, the cyber range, power hardware-in-the-loop testing, and more. With support from the U.S Department of Energy (DOE), the ESIF laboratories continue to deliver leading solutions for secure, reliable, and affordable power.

24 POWER TRANSMISSION AND DISTRIBUTION