Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “hardware-in-loop (HIL)”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

Demonstrating Distribution System Resiliency through Grid-Edge Microgrids, on a Multi-Site Networked Hardware-in-Loop Platform

With the increasing penetration of Distributed Energy Resources (DERs) at the grid-edge, power systems include more energy storage, remote switches, relays, voltage regulators, and other intelligent electronic devices (IED). Effective control of these grid-edge devices by using Advanced Distribution Management Systems (ADMS) can yield substantial improvements to the resiliency and power quality of distribution systems. In this paper, improvements to the resiliency of a distribution system are demonstrated using a multi-site evaluation environment consisting of a real-time Hardware-in-Loop (HIL) setup in which DERs and other IEDs are modeled; and an ADMS which monitors and is able to control the distribution system assets. The HIL model and the ADMS are located 2400 km away, with communication between the sites enabled by a data manager using Distributed Network Protocol 3 (DNP3), demonstrating the system's capabilities even over long distances. After a simulated transmission system failure in the HIL demonstration setup, DERs and other devices are operated to restore critical loads and node voltage profile (to within the 'nominal +/-5%' band) in the distribution system.

ADMS↗

Cybersecurity Assessment in DER-rich Distribution Operations: Criticality Levels and Impact Analysis

The integration of distributed energy resources (DERs) in distribution networks has become a pivotal strategy for achieving decarbonization, enhancing grid resilience, and optimizing grid efficiency. Remote monitoring and control op- erations of such resources rely on a network of sensors and communication infrastructure, exposing the system to potential cyber threats. Therefore, as the deployment of DERs increases, ensuring secure monitoring and control becomes an imperative challenge. This paper utilizes real-time feeder models, which are instrumental in developing cybersecurity testbeds tailored for hardware-in-loop (HIL) systems. These models enable users to simulate cyber attacks in a real-world environment and analyze the power distribution operations during vulnerabilities. Furthermore, we discuss several practical sets of grid parameters to identify critical levels of DERs and evaluate various scenarios that simulate cyber threats on sensitive DERs. The modified IEEE 123-bus model is used as the test case for demonstrating the proposed scenarios. The findings from this study provide valuable insights into the vulnerabilities and potential consequences of cyber attacks on DERs, allowing for better mitigation strategies and improved cyber resilience in future distribution networks.

Maharjan, Manisha↗

Multi-Convertor Configurable Simulator for Dynamic Radioisotope Power Systems

This paper presents the multi-convertor configurable simulator (MCCS) that can emulate piston/displacer dynamics and power outputs of various types of free-piston Stirling convertors developed at NASA GRC, including Technical Demonstration Convertor (TDC), Advanced Stirling Convertor (ASC), Flexure Isotope Stirling Convertor (FISC), Sunpower Robust Stirling Convertor (SRSC), and P2A. The MCCS can emulate up to four convertors, instead of two convertors in state-of-the-art Stirling simulators, and the maximum power output for each convertor is 1kW. Furthermore, hardware and software changes required to switch between convertors are minimized for easy conversion. A hardware-in-loop (HIL) system is used to easily switch between convertors by updating linearized modeling parameters in software. Also, switched-mode AC power supplies are used to generate wide ranges of voltage and current to emulate different types of Stirling convertors without replacing AC power supplies. Finally, the inductors emulating the linear alternator, which is the only hardware change needed for conversion, are modularized in alternator boxes to enable easy replacement of the inductors. These two features—easy conversion and capability of emulating up to four 1kW-convertors—will enable the validation tests of multi-convertor controller (MCC) concepts that are being developed by APL, the Dynamic Radioisotope Power System (DRPS) generator, and other controller developments for current and future DRPS flight projects. Finally, the MCCS is configured to demonstrate emulation of four FISCs and the outputs of the MCCS are compared with experimental data from the actual FISC.

Free-Piston Stirling Convertor Controller↗

Distributed Energy Management for Networked Microgrids with Hardware-in-the-Loop Validation

For the cooperative operation of networked microgrids, a distributed energy management considering network operational objectives and constraints is proposed in this work. Considering various ownership and privacy requirements of microgrids, utility directly interfaced distributed energy resources (DERs) and demand response, a distributed optimization is proposed for obtaining optimal network operational objectives with constraints satisfied through iteratively updated price signals. The alternating direction method of multipliers (ADMM) algorithm is utilized to solve the formulated distributed optimization. The proposed distributed energy management provides microgrids, utility-directly interfaced DERs and responsive demands the opportunity of contributing to better network operational objectives while preserving their privacy and autonomy. Results of numerical simulation using a networked microgrids system consisting of several microgrids, utility directly interfaced DERs and responsive demands validate the soundness and accuracy of the proposed distributed energy management. The proposed method is further tested on a practical two-microgrid system located in Adjuntas, Puerto Rico, and the applicability of the proposed strategy is validated through hardware-in-the-loop (HIL) testing.

24 POWER TRANSMISSION AND DISTRIBUTION↗