A Secondary Control Framework for Microgrid Interoperability With Vendor-Agnostic Grid-Forming Units: Design, Implementation, and Demonstration via Large-Scale Hardware Setup

The reliable operation of islanded microgrids increasingly depends on secondary controls that restore voltage and frequency to nominal values and ensure accurate active and reactive power sharing. Centralized secondary control architectures achieve high accuracy through global coordination at the cost of single-point failures and limited scalability compared with decentralized/distributed approaches. But a critical gap remains in addressing the interoperability and vendor-agnostic operation of secondary controls in real-world microgrids where heterogeneous diesel generator(s) and grid-forming (GFM) inverter(s) from multiple manufacturers always coexist. Practical and vendor-agnostic interoperability guidelines for the secondary control architecture of microgrids with multiple GFM units have not yet been developed; therefore, this paper proposes an interoperable and vendor-agnostic secondary control framework that operates seamlessly across GFM units from different vendors without relying on proprietary controls and protocols, hardware, or lock-ins. The framework leverages existing communication infrastructures (e.g., Modbus TCP/IP) to enable cost-effective deployment while addressing practical challenges, such as packet loss and quantization errors. Mitigation strategies-including data averaging, situational event-triggered control, and finite-iteration execution-are introduced to enhance reliability under real-world conditions. A generalized modeling and design framework is also presented, supported by robustness analysis to demonstrate independence from vendor-specific implementations. The proposed framework is validated through a large-scale hardware demonstration using a 3-$\phi$, 480-V, 60-Hz, 713-kVA laboratory hardware microgrid involving a heterogeneous diesel generator and multiple GFM inverters, showcasing its effectiveness in achieving stable voltage and frequency restoration and accurate power sharing under practical constraints. The results highlight the framework's potential as a scalable and practical solution for next-generation microgrids requiring openness, standard framework, and interoperability.

24 POWER TRANSMISSION AND DISTRIBUTION

Data Center Power Systems: Architectures, Impact on Grid Reliability, Modeling Considerations, and Megawatt-Scale Hardware Testing [Slides]

This slide deck describes typical power systems of large datacenters along with reliability problems to bulk power systems from large-scale integration of datacenters. The slide deck covers the architecture of datacenter power systems, different power electronic converters used inside datacenters, their operation modes, and R&Dopportunities in maintaining grid stability.

24 POWER TRANSMISSION AND DISTRIBUTION

Rad-hard readout system for Timepix3 Hybrid Pixel Detectors

The Beam Gas Ionisation (BGI) profile monitor, located in the Proton Synchrotron (PS) and Super Proton Synchrotron (SPS) at CERN, requires a radiation-tolerant readout system to transfer data from the challenging accelerator surroundings to the back-end for processing. The system needs to control and acquire data from four Timepix3 Hybrid Pixel Detectors (HPDs) located directly inside the beam pipe, a highly radioactive environment. It must ensure reliability given limited hardware access and preserve signal integrity for the high-speed data (32 channels at 320 MHz). However, due to the unavailability of a suitable rad-hard Timepix3 readout, the Beam Instrumentation PiXeL (BIPXL) readout system was designed to meet these requirements. This system employs radiation-hardened components such as the GBTx and the FEASTMP, both developed at CERN. It will be compatible with forthcoming hybrid pixel detector initiatives in similarly harsh radiation conditions.

47 OTHER INSTRUMENTATION

Toward coherent quantum computation of scattering amplitudes with a measurement-based photonic quantum processor

In recent years, applications of quantum simulation have been developed to study the properties of strongly interacting theories. This has been driven by two factors: on the one hand, needs from theorists to have access to physical observables that are prohibitively difficult to study using classical computing; on the other hand, quantum hardware becoming increasingly reliable and scalable to larger systems. In this work, we discuss the feasibility of using quantum optical simulation for studying scattering observables that are presently inaccessible via lattice QCD and are at the core of the experimental program at Jefferson Laboratory, the future Electron-Ion Collider, and other accelerator facilities. We show that recent progress in measurement-based photonic quantum computing can be leveraged to provide deterministic generation of required exotic gates and implementation in a single photonic quantum processor. Published by the American Physical Society 2024

73 NUCLEAR PHYSICS AND RADIATION PHYSICS

Implementation of high-speed data acquisition at DIII-D

Research at the DIII-D National Fusion Facility in San Diego focuses on short pulse plasma discharges that specialize on various shaping profiles. High-speed data collection is a critical component for the operation of many of DIII-D’s diagnostics and is fundamental for capturing high-resolution data used in experimental data analysis. Differing techniques enable the plasma control system (PCS) to perform complex real-time feedback control on microsecond time scales. This work presents a comprehensive overview of data acquisition, focusing on the hardware and software used in reliable data acquisition at DIII-D. The robust nature of the data acquisition system allows for various techniques to coexist seamlessly. However, as modern systems capable of nanosecond resolution become more common, existing architectures will need to be modified. Here, by addressing the key challenges of high-speed data acquisition, DIII-D is able to provide real-time data used in plasma operation and has the ability to acquire high fidelity data needed for future experimental fusion reactors, such as ITER.

Control

A New Era for Bubble Chamber Technology

Neutrino experiments like DUNE are limited by how well we understand the way neutrinos actually interact with atoms. The best way to fix that is to measure interactions on hydrogen, since a hydrogen nucleus is just a single free proton with largely none of the nuclear effects that heavier targets like argon have. The catch is that no one has built a hydrogen bubble chamber for a neutrino beam since the 1980s, mostly because the old chambers had too low of an active time. MAMBA is a project focused on bringing that technology back but built to cycle continuously at 1 Hz. I spent my summer internship on two of the subsystems that make that kind of speed possible. First, I helped install and test a new solid copper thermal link that replaced the old flexible braided cooling path, and it brought the coldhead down to 21.3 K, right at the target temperature. Second, I built and tested a Raspberry Pi based PLC control system, and across 20,000 trials it answered in a median of 0.64 ms, with only 0.66\% of trials running past 1 ms. Both results point the same direction: that inexpensive, off the shelf hardware can perform fast and reliable enough to eventually run a bubble chamber the way MAMBA needs it to run.

Williams, Nicholas [DuPage Coll.]

Study of the Protection Improvements for a Weak Grid Area With High Inverter-Based Resources (IBRs)

This project designs enhanced protection scheme for the real-world weak grid area with a high penetration of IBRs. As the existing protection schemes are originally designed for traditional synchronous machines, we first evaluate if the protection scheme will continue to operate reliably in systems with high levels of IBRs. Hardware relays are tested using a controller-hardware-in-the-loop setup. PSCAD electromagnetic transient simulation with IBR original equipment manufacturer black-box models is used to perform fault studies and generate COMTRADE data, which are replayed by a real-time digital simulator (RTDS) to feed input to the hardware relays. Three scenarios are analyzed: normal operation, an N-1 contingency, and an IBR-only scenario. The evaluation results reveal the following: 1) the protection scheme remains reliable under normal conditions and N-1 contingencies and 2) in IBR-only scenarios, differential protection (87L) continues to operate reliably, whereas local protection elements, such as distance and directional elements, fail because of the lack of regulated negative sequence current contributed by IBRs. Enhanced protection is designed to address the challenge of lack of negative sequence current from IBRs, including increased restraining factors a2 and k2 to block 32Q or using V instead QV ORDER for ground faults, enhanced mho distance element with voltage and phase angle supervision for L-L faults. The efficacy of enhanced protection logic is validated and proven to work reliably. Additionally, IEEE Std. 2800-2022 negative sequence current compliant GFL and GFM IBRs from another vendor are tested and proven to work reliably without need for enhanced logic. Therefore, this work provides valuable decision-making for utilities facing protection system challenges due to IBRs, either designing enhanced protection scheme or requesting their IBRs being IEEE Std. 2800-2022 compliant to produce regulated negative sequence current for protection relay to make correct decision.

24 POWER TRANSMISSION AND DISTRIBUTION

Evaluating Protection System Performance for a Real-World Weak Grid Area With High Inverter-Based Resources

This paper evaluates an existing protection scheme implemented in a real-world weak grid area with a high penetration of inverter-based resources (IBRs). The study aims to assess the reliability and adequacy of protection schemes originally designed for traditional synchronous machine systems and determine whether they can continue to operate reliably in systems with high levels of IBRs. Hardware relays are tested using a controller-hardware-in-the-loop setup. PSCAD electromagnetic transient simulation with an IBR original equipment manufacturer black-box model is used to perform fault studies and generate COMTRADE data, which are replayed by a realtime digital simulator (RTDS) to feed input to the hardware relays. Three scenarios are analyzed: normal operation, an N-1 contingency, and an IBR-only scenario. The evaluation results reveal the following: 1) the protection scheme remains reliable under normal conditions and N-1 contingencies and 2) in IBRonly scenarios, differential protection (87L) continues to operate reliably, whereas local protection elements, such as distance and directional elements, fail because of the lack of regulated negative sequence current contributed by IBRs. These findings provide utilities with valuable insights for improving their protection systems in high-IBRs.

24 POWER TRANSMISSION AND DISTRIBUTION

Evaluating Protection System Performance for a Real-World Weak Grid Area With High Inverter-Based Resources: Preprint

This paper evaluates an existing protection scheme implemented in a real-world weak grid area with a high penetration of inverter-based resources (IBRs). The study aims to assess the reliability and adequacy of protection schemes originally designed for traditional synchronous machine systems and determine whether they can continue to operate reliably in systems with high levels of IBRs. Hardware relays are tested using a controller-hardware-in-the-loop setup. PSCAD electromagnetic transient simulation with an IBR original equipment manufacturer black-box model is used to perform fault studies and generate COMTRADE data, which are replayed by a real-time digital simulator (RTDS) to feed input to the hardware relays. Three scenarios are analyzed: normal operation, an N-1 contingency, and an IBR-only scenario. The evaluation results reveal the following: 1) the protection scheme remains reliable under normal conditions and N-1 contingencies and 2) in IBR-only scenarios, differential protection (87L) continues to operate reliably, whereas local protection elements, such as distance and directional elements, fail because of the lack of regulated negative sequence current contributed by IBRs. These findings provide utilities with valuable insights for improving their protection systems in high-IBRs.

24 POWER TRANSMISSION AND DISTRIBUTION

Leveraging PHIL for Inverter Functionality Requirement Evaluation to Ensure a Reliable Grid

This presentation showcases NREL's ongoing research on advanced Multi-point Power Hardware-in-the-Loop (PHIL) systems, enabling comprehensive evaluation of interoperability, stability, and wide-area stability in complex power grids. Key features include high-power PHIL capabilities, seamless PHIL Interfaces for effortless Grid-Following (GFL) and Grid-Forming (GFM) mode switching, and advanced multi-domain PHIL/Controller Hardware-in-the-Loop (CHIL) capabilities for evaluating diverse technology mixes, facilitating rigorous testing and validation of emerging power systems for reliable integration, enhanced resilience, and optimal performance.

lab capabilities

A Study on the Impact of Temperature-Dependent Ferroelectric Switching Behavior in 3D Memory Architecture

The flourishing development of neural networks that require exponentially growing amounts of data has presented an elevated demand for memory footprint. To address this, researchers have been exploring hardware accelerators with innovative memory architectures like 3D memory. These 3D memory architectures offer enhanced storage capacity and processing capabilities, at a cost of rising on-chip temperature during operation. Hafnium Zirconium Oxide (HZO) based Ferroelectric Random Access Memory (FeRAM) is a promising nonvolatile memory candidate in neural network hardware accelerators for its outstanding write performance and reliability. However, its implementation in the architecture regarding the temperature-dependent ferroelectric switching behavior has not been well studied. In this work, we study the thermal impacts on polarization switching through experimental devices and simulation results. We conduct the circuit and architecture-level simulations to showcase that one can exploit this temperature rise to reduce FeRAM's write voltage and write energy due to its unique temperature-activated polarization switching mechanisms. As the on-chip temperature increases to 351K (ambient temperature at 300K) due to neural network workloads, the access energy per bit can be reduced by 27.6% when a dynamic write voltage is applied.

36 MATERIALS SCIENCE

Hardware-in-the-Loop Evaluation for Potential High Limit Estimation-Based PV Plant Active Control

This paper validates the efficacy of an artificial intelligence (AI)-based photovoltaic (PV) plant control and optimization approach in enabling PV plants as accountable grid reliability service providers. The validation is performed in a realistic laboratory controller-hardware-in-the-loop environment, leveraging accurate PV plant modeling and standard industrial communication protocols. Through simulations that account for diverse weather conditions and active control scenarios, the results highlight the superior performance of the AI-based solution in comparison to a state-of-the-art reference-control grouping-based approach. Such a finding contributes to mitigating the risk of overcurtailment and uninstructed deviations of active PV plant controls, and offers practical guidance for its field deployment. Furthermore, it establishes a standardized testing framework for comparing various PV active control strategies.

hardware-in-the-loop

TEAMER – Enhanced Flow Measurement for Aquantis Tidal Turbine Test

The AQ10 is a floating, two-bladed, passive yawing tidal turbine developed by Aquantis that has a 10-meterrotor diameter, 160 kW rating, and employs reliable off-the-shelf powertrain and power conversion hardware. Aquantis is planning on-water turbine power performance and loads (blade loading and thrust)testing, where the turbine will be pushed through still water up to 4 knots and placed in a ‘station keeping’ tow in a tidal race up to its rated speed. On-water testing will be conducted using vessels and floating platforms on the sea surface to improve ease of testing and reduce disturbance to the environment. In this TEAMER project, Pacific Northwest National Laboratory (PNNL) will conduct water velocity and turbulence measurements in front of the turbine during on-water testing using acoustic Doppler instrumentation. By measuring both the tidal current flowing past the turbine and the resulting electrical power output, test results will provide a power curve (power vs flow speed) for the turbine up to rated power. Measurements of turbulence and velocity shear in front of the rotor will also provide information to assess the structural response of the rotor blades. With this analysis, Aquantis can use the performance and loads data to validate Tidal Bladed and OpenFAST simulations of the measured operating conditions. Measuring the power performance of a prototype turbine is a valuable step to improving device development and conducting a complete power performance assessment to IEC/TS 62600-200 standards in the future.

16 TIDAL AND WAVE POWER

Performance Evaluation of a Microgrid System with Grid-Forming and Grid-Following Inverters with Diesel Generators: Insights From Hardware Experiments

This paper presents a comprehensive performance evaluation of a microgrid system integrating grid-forming (GFM) inverters, grid-following (GFL) inverters, and a diesel generator, focusing on their interactions and behavior under various dynamic events. The study is conducted using a pure hardware setup comprising two GFM inverters, one GFL inverter, a diesel generator, load banks, a point of common coupling (PCC), and an emulated main grid. The evaluation specifically examines dynamic scenarios, including voltage jumps, phase jumps, rate of change of frequency (ROCOF), synchronization, and islanding operations, which pose critical challenges to system stability. Among all the tests conducted, the overloading and phase jump tests proved to be the most challenging. The capacity of the DC side is crucial for withstanding overloading and grid disturbance tests; otherwise, GFM inverters frequently trip due to DC undervoltage. Throughout all grid disturbance tests, the diesel generator consistently stands out as the most robust and reliable GFM unit in the system. Overall, insights from these hardware experiments shed light on the response characteristics of different generation types during grid disturbances and identify potential stability concerns in such hybrid microgrid systems.

14 SOLAR ENERGY

VECTOR Phase 1 Dataset: CAV Trajectory and Energy Consumption Records

This dataset contains benchmark experimental data from Phase 1 of the VECTOR project, focusing on the energy impact of CAV hardware components. The dataset includes vehicle trajectory data (speed and position) and corresponding energy consumption records collected from a CAV platform equipped with lidar, cameras, onboard computation units, and communication modules. The primary objective is to quantify the baseline energy consumption attributable to sensing and computing systems, independent of any advanced cooperative control strategies. During experiments, the leading vehicle followed a predetermined velocity profile, and the following CAV mirrored this trajectory using a basic car-following control to ensure consistent driving behavior. This setup enables a reliable benchmark for assessing the energy cost introduced by onboard CDA hardware (e.g., lidar and GPU-based processing). The dataset is essential for evaluating energy baselines and supports future comparative studies involving additional cooperative strategies. ![system img](system.png) ![vector img](vector.png)

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI

Automated, reliable, and efficient continental-scale replication of 7.3 petabytes of computational simulation data: A case study

We report on our experiences replicating 7.3 petabytes (PB) of Earth System Grid Federation (ESGF) computational simulation data from Lawrence Livermore National Laboratory (LLNL) in California to Argonne National Laboratory (ANL) in Illinois and Oak Ridge National Laboratory (ORNL) in Tennessee—a task motivated by a need for increased reliability, capacity, and performance. This task presented significant challenges: the need to move 29 million files twice under time pressure from aging storage hardware; a source file system bottleneck limiting throughput to 1.5 GB/s; frequent site maintenance windows; and the need for complete reliability at scale. We addressed these challenges using a simple replication tool that invoked Globus to transfer large bundles of files while tracking progress in a database, dynamically rerouting transfers to work around maintenance periods and file system limitations. Under the covers, Globus organized transfers to make efficient use of the high-speed Energy Sciences network (ESnet) and the data transfer nodes deployed at participating sites, and also addressed security, integrity checking, and recovery from a variety of transient failures. This success demonstrates the considerable benefits that can accrue from the adoption of performant data replication infrastructure. The replication tool is available at https://github.com/esgf2-us/data-replication-tools.

Globus

Supervised Learning-Based Spatial Position Estimation with Vertical Displacement for Hovering UAV Wireless Power Transfer

This study presents a supervised learning-based spatial position estimation approach for wireless power transfer (WPT) systems supporting hovering unmanned aerial vehicle (UAV) charging. Unlike stationary charging scenarios, hovering UAVs introduce continuous lateral misalignment and vertical displacement, leading to variations in magnetic coupling and reduced power transfer efficiency. To address this challenge, the proposed method estimates the relative spatial position of the receiver coil using only electrical measurements obtained at the secondary side. A supervised learning model is trained to map output voltage and current features to spatial coordinates, enabling position awareness without requiring external sensors, vision systems, or communication links. The sensing functionality is inherently integrated into the WPT system, allowing simultaneous power transfer and localization through the same magnetic interface. Experimental validation is conducted on a laboratory-scale prototype under varying lateral offsets and air-gap conditions. In addition, spline-based interpolation is employed to increase spatial data density for training. The results demonstrate that the proposed framework can capture spatial variations associated with both lateral and vertical displacement, providing reliable position estimation under hovering conditions. This work establishes a hardware-efficient, sensorless solution for UAV wireless charging and serves as a baseline for advanced data-driven position estimation methods in dynamic WPT systems.

Asa, Erdem [ORNL] (ORCID:0000000190884812)

Flexible AI Models for Grid Resilience

The rapid growth in size and complexity of artificial intelligence (AI) and machine learning (ML) models has led to increased energy demands, posing a threat to the reliability of the existing power grid. This project addresses the challenge of highly intermittent and energy-intensive inference workloads by (1) developing fidelity-adaptive neural networks capable of dynamic response to grid conditions and (2) integrating these networks with power flow simulations to assess their impact on power grid reliability. We will explore both top-down and bottom-up approaches to create hierarchies of submodels that provide a controlled trade-off between power draw and prediction accuracy. The top-down method utilizes NN pruning to reduce a flagship model into progressively smaller, energy-efficient variants. The bottom-up approach employs geometrically principled weight setting strategies to construct depth-efficient models from the ground up. A real-time hardware-in-the-loop (HIL) platform will be developed to simulate a scaled AC power grid, integrating live AI workload power draw and enabling dynamic model switching in response to grid feedback. This work will provide a novel framework for evaluating the impact of flexible AI/ML workloads on grid performance and establish new methodologies for energy-aware computing in data centers. The outcomes will demonstrate that adaptive AI/ML can play a critical role in improving grid stability while advancing NREL's leadership in energy-efficient computing research.