Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “hardware in the loop”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Demonstrating Distribution System Resiliency through Grid-Edge Microgrids, on a Multi-Site Networked Hardware-in-Loop Platform

With the increasing penetration of Distributed Energy Resources (DERs) at the grid-edge, power systems include more energy storage, remote switches, relays, voltage regulators, and other intelligent electronic devices (IED). Effective control of these grid-edge devices by using Advanced Distribution Management Systems (ADMS) can yield substantial improvements to the resiliency and power quality of distribution systems. In this paper, improvements to the resiliency of a distribution system are demonstrated using a multi-site evaluation environment consisting of a real-time Hardware-in-Loop (HIL) setup in which DERs and other IEDs are modeled; and an ADMS which monitors and is able to control the distribution system assets. The HIL model and the ADMS are located 2400 km away, with communication between the sites enabled by a data manager using Distributed Network Protocol 3 (DNP3), demonstrating the system's capabilities even over long distances. After a simulated transmission system failure in the HIL demonstration setup, DERs and other devices are operated to restore critical loads and node voltage profile (to within the 'nominal +/-5%' band) in the distribution system.

ADMS↗

Use of Power Hardware-in-the-Loop and Controller Hardware-in-the-Loop to De-Risk the Use Of Grid-Forming Fuel Cell Inverters in Microgrids

Microgrids continue to proliferate, particularly those that rely on inverter-based resources as the microgrid's voltage and frequency leader. Hardware-in-the-loop simulations can de-risk microgrid deployments, and therefore we need power-hardware-in-the-loop (PHIL) interfaces for grid-forming (GFM) inverters to enable simulations of seamless transitions between islanded and grid-connected operation. Such interfaces are particularly challenging when the inverters need to switch modes, i.e., between grid-following (GFL) and GFM as the microgrid transitions between grid-connected and islanded operation. This presentation shows the use of PHIL interfaces for such microgrids and the preliminary experimental results.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Hardware-in-Loop Modules for Testing Automated Ventilator Controllers

Automated ventilator controllers have the potential to simplify oxygen and carbon dioxide management for trauma. In the pre-hospital or military medicine environment, trauma care can be required for prolonged periods by personnel with limited ventilator management training. As such, there is a need for closed-loop control systems that can adapt ventilator management to a complex, ever-changing medical environment. Here, we present a novel hardware-in-loop test platform for the independent troubleshooting and evaluation of oxygen and carbon dioxide automated ventilator management capabilities. The oxygen management system provides an analogue blood oxygen signal that is responsive to the fraction of inspired oxygen and the peak inspiratory pressure ventilator settings. A tested oxygenation controller successfully reached the target oxygen saturation within 5 min. The carbon dioxide removal system integrates with commercial ventilator technology and mimics carbon dioxide generation, lung compliance, and airway resistance while providing an end-tidal carbon dioxide level that is responsive to changes in the tidal volume and respiratory rate settings. A test mechanical ventilator controller was able to regulate EtCO2 regardless of the starting value within 10 min. This highlights the system’s functionality and provides proof-of-concept demonstrations for how the hardware-in-loop test platforms can be used for evaluating closed-loop controller technologies.

Berard, David (ORCID:0000000322863846)↗

Computational capacity in hydrodynamic real-time hybrid simulation applied to simulate the dynamic response of floating offshore wind turbines

Real-time hybrid simulation (RTHS) mitigates similitude distortions in model-scale tests of floating offshore wind turbines (FOWTs) by coupling physical experiments with numerical models in real time. The coupling requires faster-than-real-time numerical computations to satisfy temporal similitude with the physical experiment, presenting a bottleneck for using more complex numerical models in RTHS. This paper presents a hydrodynamic-RTHS (hydro-RTHS) framework for FOWTs that simulates the hydrodynamics physically and the aerodynamics numerically with sensor feedback from the physical testing. The framework adapts the three-loop hardware architecture to leverage greater computational resources and mitigate strict temporal requirements, enabling more computationally demanding numerical analyses in hydro-RTHS. The three-loop hardware architecture integrates multiple machines, each dedicated to either numerical analysis or RTHS controls, with a rate-transition algorithm to synchronize the tasks executed across the different machine processors. Virtual and physical tests verified and validated the hydro-RTHS framework, respectively. The ”virtual” tests, which approximates the physical domain numerically, verified the RTHS framework with respect to a numerical full-scale complete FOWT model simulated in the open-source software, OpenFAST. The virtual tests were able to maintain comparable control signals while enabling greater computational resources for the numerical calculations. Real-world physical tests demonstrated that the hydro-RTHS framework computes aerodynamic forces similar to the complete OpenFAST model, validating the hydro-RTHS framework using the three-loop hardware architecture. Findings show that the hydro-RTHS framework with the three-loop hardware architecture is computationally efficient, with reserve capacity to simulate more complex problems due to the customized software, hardware, and rate-transition algorithm.

17 WIND ENERGY↗

Power-Hardware-in-the-Loop Interfaces for Inverter-Based Microgrid Experiments Including Transitions

Microgrids continue to proliferate, particularly those that rely on inverter-based resources as the microgrid's voltage and frequency leader. Hardware-in-the-loop simulations can de-risk microgrid deployments, and therefore we need power-hardware-in-the-loop (PHIL) interfaces for grid-forming (GFM) inverters to enable simulations of seamless transitions between islanded and grid-connected operation. Such interfaces are particularly challenging when the inverters need to switch modes, i.e., between grid-following (GFL) and GFM as the microgrid transitions between grid-connected and islanded operation. This paper presents two PHIL interfaces for such microgrids and the preliminary experimental results.

experiments↗

Modeling and Feedback Compensator Design for Power-Hardware-in-the-Loop System for Medium-Voltage Grid-Connected Power Converters

Hardware-in-the-loop (HIL) evaluation is a method in which the test subject is split into a physical part and a simulated part, and these parts are connected with interfaces to form a combined physical-numerical system. Power-hardware-in-the-loop (PHIL) systems, where actual hardware is connected to a real-time model, can exhibit issues of instability, inaccuracy and errors when operating in a closed-loop. The challenges of generating a PHIL setup are that, first, because of the limited dynamic response of the different parts of the system, the test results might be inaccurate, and, second, because of the high frequency noise introduced by the sensors to the closed-loop system, it can be difficult to design a compensator for the real-time emulator response, while stabilizing the closed-loop system at the same time. In this paper, different parts of a PHIL system are characterized, and the feedback compensator system design is proposed for the stable operation of the closed-loop PHIL system. The issues as observed in a PHIL system without any compensator are demonstrated using experimental results, and the effectiveness of a first order phase lead compensator is validated.

compensator design↗

Using Hardware-In-The-Loop Methodology to Develop Test Systems

Hardware in the Loop (HIL) testing methodologies have become widespread in industry. Typically, they focus on developing control algorithms for systems such as autonomous vehicles or aircraft. An oft overlooked aspect of product development is the design and fabrication of a test system for validating that the product meets requirements. Abstractly, a test system differs little from a control system—testers provide signals to the unit, monitor feedback, and base decisions on the results. While the time scales may differ, the functionalities are conceptually similar. Viewed in this light, it becomes natural to extend HIL approaches to tester development. By replacing a physical unit with a proxy model deployed to a real-time or pseudo real-time target, test systems can be developed in parallel with the design and fabrication of a first production unit. This saves considerable time in the life cycle from conceptual design to realized product. This manuscript demonstrates the process flow using a capacitive discharge unit as an exemplar.

42 ENGINEERING↗

PBE-HIL (Powering the Blue Economy Hardware-in-the-Loop models) [SWR-25-37]

Powering the Blue Economy Hardware-in-the-Loop models (PBE-HIL) is a repository of Power Hardware-in-the-loop models developed for typical Powering the Blue Economy market loads and power requirements. The HIL models were developed to be as generic and functional as possible, meaning that the user can easily configure these models to represent their unique PBE design. These PBE load and power requirement HIL models can then be used to inform marine energy converter (MEC) and power electronics design, as well as be used in laboratory testing using HIL equipment, leading to improved understanding of MEC performance and lower risk prior to open-water MEC deployment.

Labuschagne, Hannes [National Renewable Energy Lab↗

Grid impact analysis using controller-hardware-in-the-loop for high-power vehicle charging stations

A controller-hardware-in-the-loop (CHIL) architecture for the evaluation of grid impacts arising from high-power vehicle charging stations is presented in this paper. Unlike simulation-based studies, the proposed method can be used to capture the interactions of the grid and the charging load along with charger controllers in real time. The proposed method can be used to evaluate the impact of charging load on the grid in terms of voltage variations and line congestion. The proposed CHIL platform allows for de-risking the vehicle charging station deployment by simulating the complex interactions among all the components of a vehicle charging station - i.e., the grid, vehicle, and charger controller - in a realistic manner before using the charging station in a grid. Further, the proposed CHIL approach can be used to evaluate the voltage regulation causalities of the vehicle charging station. Experimental results are presented in the paper to illustrate the applicability of the proposed method in a laboratory environment.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Novel Power-Hardware-in-the-Loop Interface Method for Grid-Forming Inverter Systems

Power-hardware-in-the-loop (PHIL) simulations of grid-forming (GFM) inverter systems facilitate the testing of drastic scenarios, such as on-grid to off-grid transitions and islanded microgrid operations without a stiff grid. To the authors’ best knowledge, most studies in the literature focus on PHIL simulations for grid-following inverter systems. Only a few studies focus on GFM inverters, and those are challenging and problematic, especially for high-power applications. This article proposes a novel PHIL simulation platform that enables interfacing high-power GFM inverter systems. The paper proposes the concept of a virtual GFM inverter as a part of the proposed PHIL interface. This addition of a virtual GFM inverter in the PHIL interface expands the conventional ideal transformer model (ITM) method and enables it to overcome the issues of instability of existing ITM methods. In the validation stage, a PHIL experiment is conducted on a three-phase, 480-V, 125-kVA GFM inverter system with the proposed interfacing method. The results corroborate that the proposed PHIL simulation method performs well and is stable for GFM inverter systems.

droop control↗

BENEFIT with Northeastern University: HVAC Hardware-in-the-Loop Experimental Testing of a Heat Pump and Air Conditioner

This dataset includes HVAC Hardware-in-the-Loop (HIL) experimental results for a single stage, SEER 16, HSPF 9.5, 3-ton single-speed air source heat pump with 15 kW of backup auxiliary heating tested in both cooling and heating mode, and a two stage, SEER 21, 2-ton central air conditioner tested in cooling mode for a set of outdoor temperatures and indoor setpoint temperatures. In addition to these tests, experimental tests focused on the operation of auxiliary heating for the heat pump for winter condition were also conducted. The laboratory experiments for transient testing of the heat pump and air conditioner were conducted using the two HIL systems in the Systems Performance Laboratory (SPL) at NREL’s Energy Systems Integration Facility (ESIF). Further information on laboratory design and capabilities of the SPL along with the architecture of HVAC HIL system can be found in: Sparn, B. F. 2018. Laboratory Resources and Techniques to Evaluate Smart Home Technology (No. NREL/CP-5500-71696). National Renewable Energy Laboratory (NREL), Golden, CO (United States). https://www.nrel.gov/docs/fy18osti/71696.pdf and the experimental setup and validation of HVAC HIL platform can be found in: Ramaraj, S. and Sparn, B. 2022. Validation of HVAC Hardware-In-the-Loop Simulation for Advanced Control Strategies in Smart Homes (No. NREL/CP-5500-82562). National Renewable Energy Lab (NREL), Golden, CO (United States). https://www.nrel.gov/docs/fy22osti/82562.pdf. These experimental results can be used to validate how we currently model the cycling behavior of heat pumps and air conditioners. Additionally, many demand response programs implement heat pump and air conditioner control by changing the thermostat set point – these data may also be used to verify our models for heat pump and air conditioner demand response control are implemented correctly. The Test_Matrix file describes all the indoor and outdoor test conditions for heat pump and air conditioner and the file names of data sets include information about the test conditions. A wide range of outdoor air temperatures were chosen to accommodate summer and winter conditions. In addition to operating the HVAC equipment with different outdoor temperatures, we also operate the system with different indoor temperature set points to represent different grid signals or different operating conditions. For cooling conditions, the baseline set point is 72°F. To represent Load Up signals, the setpoint is changed to 68°F. The Load Shed set point is 76°F. For heating conditions, the baseline set point was assumed to be 68°F. The Load add set point is 72°F and the Load shed set point is 64°F. The starting indoor temperature for cooling conditions was set ~2°F above the indoor setpoint temperature so that the equipment turned on quickly. Similarly, the initial indoor temperature was set ~2°F lower than setpoint for heating mode tests to ensure that heating began quickly. The return air temperature was assumed to be equal to the indoor setpoint temperature in all cases. The experimental data are sampled at 1-second intervals. The data from ecobee thermostat at 5-minute interval are resampled and added to the corresponding file. The content of each data set is as follows: • T_Return (C): Measured return air temperature [C] • T_Return_SP (C): Return air temperature setpoint from E+ model, sent to HIL [C] • T_Supply (C): Measured supply air temperature at evaporator outlet [C] • T_Outdoor (C): Measured outdoor air temperature [C] • T_Outdoor_SP (C): Outdoor air temperature setpoint from weather file, sent to HIL [C] • T_Indoor (C): Measured indoor air temperature [C] • T_Indoor_SP (C): Indoor air temperature setpoint from E+ model, sent to HIL [C] • Outdoor Unit Power (W): Measured power of the outdoor unit [W] • Indoor Unit Power (W): Measured power of the indoor unit [W] • Evaporator Airflow Rate (CFM): Measured evaporator or indoor unit airflow rate sent to E+ model [CFM] • Cooling/Heating Capacity (kW): Calculated cooling/heating capacity sent to E+ model [kW] • T_SP_Thermostat (C): Thermostat cooling/heating setpoint temperature [C] • T_Indoor_Thermostat (C): Thermostat indoor air temperature [C]

24 POWER TRANSMISSION AND DISTRIBUTION↗

A Novel Power-Hardware-in-the-Loop Interface Method for Grid-forming Inverter Systems: Preprint

Power Hardware-in-the-Loop (PHIL) simulation of grid-forming (GFM) inverter systems facilitates the testing of drastic scenarios like on-grid to off-grid transition, islanded microgrid operation without stiff grid etc. To the authors best knowledge, most of studies in literature are focused on PHIL simulation for grid-following inverter systems and only few studies are focused on GFM inverters and those are challenging and problematic especially for high-power applications. In this article, a novel PHIL simulation platform is proposed that enables interfacing of high-power GFM inverter systems. It proposes the concept of a virtual GFM inverter as a part of the proposed PHIL interface for GFM inverter. This addition of virtual GFM inverter in the PHIL interface expands the conventional Ideal Transformer Model (ITM) method and enables it to overcome the issues of instability of existing ITM methods. In the validation stage, a PHIL experiment is conducted on a 3-phase 480 V, 125 kVA GFM inverter system with proposed interfacing method. The results corroborates the fact that the proposed PHIL simulation method performs well and stable for GFM inverter system.

grid-forming inverters↗

A full-scope, high-fidelity simulator-based hardware-in-the-loop testbed for comprehensive nuclear power plant cybersecurity research

Nuclear power plant (NPP) cybersecurity research often relies on hardware-in-the-loop (HIL) testbeds that integrate real hardware components into simulated environments. These testbeds allow researchers to identify vulnerabilities, evaluate attack impacts, and test security measures in a controlled setting. Furthermore, previous HIL testbeds lacked fidelity to accurately represent real nuclear systems, limiting the scope of cybersecurity analysis. This study presents the creation of a HIL testbed, devised upon a full-scope, high-fidelity NPP simulator, to facilitate realistic and comprehensive cybersecurity research. To demonstrate its capabilities, the control logic for the steam generator water level was migrated from the simulator to an external programmable logic controller. As a practical application of the developed testbed, supply chain attack scenarios were simulated by injecting malicious code into the controller logic, and the effects of manipulating sensor inputs and control commands were observed. While this HIL testbed provides more detailed simulations, enhanced realism, and wider applicability compared to other options utilizing a less complex simulator, it is also more intricate and costly. For this reason, we include a detailed comparison with some alternative architectures to aid fellow researchers and practitioners in the selection of a suitable HIL architecture based on specific research objectives.

47 OTHER INSTRUMENTATION↗

Stability and Fidelity of Power-Hardware-in-the-Loop Using NREL's CGI

The presentation focuses on dynamic analysis of power hardware-in-the-loop (PHIL) experiments using National Renewable Energy Laboratory Flatirons Campus' grid simulator - 7MVA Controllable Grid Interface (CGI). A control diagram of typical PHIL experiment is described, and transfer functions of critical components are explained. An impedance-based definition of PHIL experiment bandwidth is defined using open loop transfer functions of the system. Further an example resistive divider circuit is introduced that is used to explain implication of PHIL on accuracy of simulation by comparing measured results against ideal expected signals. At the end the real-life PHIL simulation using Maui power system model is described showing various oscillation modes observed and discussing the meaning of these in context of dynamic bandwidth of simulation.

grid simulator↗

A Power-Hardware-in-the-Loop (PHIL) Evaluation of Service Restoration With Networked Microgrids

This paper describes the power-hardware-in-the- loop (PHIL) evaluation of the feasibility of service restoration solutions determined by the PowerModelsONM.jl tool. This tool incorporates microgrids and the networking of microgrids into its determination of an optimal service restoration solution. The paper presents PHIL simulation results for a case study based on a real distribution feeder with multiple microgrids, showcas- ing the effectiveness of networked microgrids in aiding system restoration after an outage. The study leverages high-fidelity, real- time electromagnetic transient models to ensure accuracy in the simulation results. This work is the final output from the Resilient Operation of Networked Microgrids (RONM) project funded by the U.S. Department of Energy Office of Electricity Microgrid Program and led by Los Alamos National Laboratory. RONM focused on the application of PowerModelsONM.jl to enhance the resilience of distribution systems.

fault location isolation and service restoration (↗

Intelligent Hierarchical Resilient Operation of Distribution Systems: Implementation and Validation in a Power Hardware-in-the-Loop Simulation Testbed

This paper reports on the structure of a power hardware-in-the-loop (PHIL) simulation testbed that implements, tests, and validates a novel AI-based hierarchical resilient operation model for distribution systems. The testbed implements the central and distributed controllers of the hierarchical resilient operation model and integrates a Digital Real-Time Simulator (DRTS), protective relays, a Real-Time Automation Controller (RTAC), a Software Defined Network (SDN) switch, and a battery energy storage (BES) system. The testbed provides comprehensive real-time visualization and monitoring capability as an advanced situational awareness and operator interface solution. The IEEE 33-node system is used as a test case to test and validate the operation of the model in normal operation and recovery operation after major outages in a fully automated fashion.

Ganjkhani, Mehdi↗

Power Hardware-in-the-Loop Interfaces for Inverter-Based Microgrid Experiments Including Transitions: Preprint

Microgrids continue to proliferate, particularly those that rely on inverter-based resources as the microgrid's voltage and frequency leader. Hardware-in-the-loop (HIL) simulations can de-risk microgrid deployments, and therefore we need power-hardware-in-the-loop (PHIL) interfaces for grid-forming (GFM) inverters to enable simulations of seamless transitions between islanded and grid-connected operation. Such microgrid interfaces are particularly challenging to model when the inverters need to switch modes, i.e., between grid-following (GFL) and GFM as the microgrid transitions between grid-connected and islanded operation. This paper presents two PHIL interfaces for such microgrids and the preliminary experimental results: One interface is suitable for those who have access to a power amplifier that can operate as a controllable current source, and the other is for those who need a solution that uses a voltage-mode power amplifier.

battery energy storage system↗

The SODA Approach: Leveraging High-Level Synthesis for Hardware/Software Co-design and Hardware Specialization: Invited

Novel "converged" applications combine phases of scientific simulation with data analysis and machine learning. Each computational phase can benefit from specialized accelerators. However, algorithms evolve so quickly that mapping them on existing accelerators is suboptimal or even impossible. This paper presents the SODA (Software Defined Accelerators) framework, a modular, multi-level, open-source, no-human-in-the-loop, hardware synthesizer that enables end-to-end generation of specialized accelerators. SODA is composed of SODA-Opt, a high-level frontend developed in MLIR that interfaces with domain-specific programming frameworks and allows performing system level design, and Bambu, a state-of-the-art high-level synthesis engine that can target different device technologies. The framework implements design space exploration as compiler optimization passes. We show how the modular, yet tight, integration of the high-level optimizer and lower-level HLS tools enables the generation of accelerators optimized for the computational patterns of converged applications. We then discuss some of the research opportunities that such a framework allows, including system-level design, profile driven optimization, and supporting new optimization metrics.

Bohm Agostini, Nicolas↗