Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “hanging droplets”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

A Fiber Optic Probe for Monitoring Protein Aggregation, Nucleation, and Crystallization

Protein crystals are experimentally grown in hanging drops in microgravity experiments on-board the Space Shuttle orbiter. The technique of dynamic light scattering (DLS) can be used to monitor crystal growth process in hanging droplets (approx. 30 (L)) in microgravity experiments, but elaborate instrumentation and optical alignment problems have made in-situ applications difficult. In this paper we demonstrate that such experiments are now feasible. We apply a newly developed fiber optic probe to various earth and space (micro- gravity) bound protein crystallization system configurations to test its capability. These include conventional batch (cuvette or capillary) systems, hanging drop method in a six-pack hanging drop vapor diffusion apparatus (HDVDA), a modified HDVDA for temperature- induced nucleation and aggregation studies, and a newly envisioned dynamically controlled vapor diffusion system (DCVDS) configuration. Our compact system exploits the principles of DLS and offers a fast (within a few seconds) means of quantitatively and non-invasively monitoring the various growth stages of protein crystallization. In addition to DLS capability, the probe can also be used for performing single-angle static light scattering measurements. It utilizes extremely low levels of laser power (approx. few (W)) without a need of having any optical alignment and vibration isolation. The compact probe is also equipped with a miniaturized microscope for visualization of macroscopic protein crystals. This new optical diagnostic system opens up enormous opportunity for exploring new ways to grow good quality crystals suitable for x-ray crystallographic analysis and may help develop a concrete scientific basis for understanding the process of crystallization.

Ansari, Rafat R.↗

High-Voltage Droplet Dispenser Developed

Various techniques have been applied to deploying individual droplets for many applications, such as the study of the combustion of liquid fuels. Isolated droplet studies are useful in that they allow phenomena to be studied under well-controlled and simplified conditions. A high-voltage droplet dispenser has been developed that is extremely effective in dispensing a wide range of droplets. The dispenser is quite unique in that it utilizes a droplet bias voltage, as well as an ionization pulse, to release the droplet. The droplet is deployed from the end of a needle. A flat-tipped, stainless steel needle attached to a syringe dispenses a known value of liquid that hangs on the needle tip. Somewhat below the droplet is an annular ring electrode. A bias voltage, followed by a voltage pulse, is applied to attract the droplet sufficiently to pull it off the needle. The droplet and needle are oppositely charged relative to the annular electrode. The needle is negatively charged, and the annular ring is positively charged.

Eichenberg, Dennis J.↗

A Simple Thermoelectric Droplet Generator

A new design for a droplet generator capable of producing single droplets is presented. The design relies on thermoelectric heating to vaporize water at the interface between a droplet and a blunt syringe tip. While other designs require careful tuning to produce drops of varying size, this technique enables the simple creation of droplets of any size within a range. The design is of simple construction and can be completed with off-the-shelf components, and relies on resistive heating to vaporize water at or near the droplet-nozzle interface and release the droplets. We demonstrated that the design can be used to produce droplets as small as 110 µm or as large as 2 mm. Drop size is limited by the geometry of the nozzle since water must wet the tip of the nozzle and hang under gravity. Our experiments showed that released droplets have relatively small disturbances introduced by the release mechanism when compared to competing techniques. These disturbances were intermittently observed as the voltage, pulse width, and drop size were changed, and optimal settings were determined for the smallest drop sizes produced.

Andrew Work↗

Experimental and theoretical analysis of the rate of solvent equilibration in the hanging drop method of protein crystal growth

The principles of the hanging-drop method of crystal growth are discussed, and the rate of water evaporation in a water droplet (containing protein, buffer, and a precipitating agent) suspended above a well containing a double concentration of precipitating agent is investigated theoretically. It is shown that, on earth, the rate of evaporation may be determined from diffusion theory and the colligative properties of solutions. The parameters affecting the rate of evaporation include the temperature, the vapor pressure of water, the ionization constant of the salt, the volume of the drop, the contact angle between the droplet and the coverslip, the number of moles of salt in the droplet, the number of moles of water and salt in the well, the molar volumes of water and salt, the distance from the droplet to the well, and the coefficient of diffusion of water vapor through air. To test the theoretical equations, hanging-drop experiments were conducted using various reagent concentrations in 25-microliter droplets and measuring the evaporation times at 4 C and 25 C. The results showed good agreement with the theory.

Fowlis, William W.↗

High-Voltage Droplet Dispenser

An apparatus that is extremely effective in dispensing a wide range of droplets has been developed. This droplet dispenser is unique in that it utilizes a droplet bias voltage, as well as an ionization pulse, to release a droplet. Apparatuses that deploy individual droplets have been used in many applications, including, notably, study of combustion of liquid fuels. Experiments on isolated droplets are useful in that they enable the study of droplet phenomena under well-controlled and simplified conditions. In this apparatus, a syringe dispenses a known value of liquid, which emerges from, and hangs onto, the outer end of a flat-tipped, stainless steel needle. Somewhat below the needle tip and droplet is a ring electrode. A bias high voltage, followed by a high-voltage pulse, is applied so as to attract the droplet sufficiently to pull it off the needle. The voltages are such that the droplet and needle are negatively charged and the ring electrode is positively charged.

Eichenberg, Dennis J.↗

Human serum albumin crystals and method of preparation

Human serum albumin (HSA) crystals are provided in the form of tetragonal plates having the space groups P42(sub 1)2, the crystals being grown to sizes in excess of 0.5 mm in two dimensions and a thickness of 0.1 mm. Growth of the crystals is carried out by a hanging drop method wherein a precipitant solution containing polyethylene glycol (PEG) and a phosphate buffer is mixed with an HSA solution, and a droplet of mixed solution is suspended over a well of precipitant solution. Crystals grow to the desired size in 3 to 7 days. Concentration of reagents, pH and other parameters are controlled within prescribed limits. The resulting crystals exhibit a size and quality such as to allow performance of x ray diffraction studies and enable the conduct of drug binding studies as well as genetic engineering studies.

Carter, Daniel C.↗

Sizing of colloidal particle and protein molecules in a hanging fluid drop

We report non-invasive particle size measurements of polystyrene latex colloidal particles and bovine serum albumin (BSA) protein molecules suspended in tiny hanging fluid drops of 30 micro-Liter volume using a newly designed fiber optic probe. The probe is based upon the principles of the technique of dynamic light scattering (DLS). The motivation for this work comes from growing protein crystals in outer space. Protein crystals have been grown previously in hanging drops in microgravity experiments on-board the space shuttle orbiter. However, obtaining quantitative information on nucleation and growth of the protein crystals in real time has always been a desired goal, but hitherto not achieved. Several protein researchers have shown interest in using DLS to monitor crystal growth process in a droplet, but elaborate instrumentation and optical alignment problems have made in-situ applications difficult. We demonstrate that such an experiment is now possible. Our system offers fast (5 seconds) determination of particle size, utilize safe levels of very low laser power (less than or equal to 0.2 mW), a small scattering volume (approximately 2 x 10(exp -5) cu mm) and high spatial coherence (Beta) values. This is a major step forward when compared to currently available DLS systems.

Ansari, Rafat R.↗

A UAV-Based Fog Collector Design for Fine-Scale Aerobiological Sampling

Airborne microbes are found throughout the troposphere and into the stratosphere. Knowing how the activity of airborne microorganisms can alter water, carbon, and other geochemical cycles is vital to a full understanding of local and global ecosystems. Just as on the land or in the ocean, atmospheric regions vary in habitability; the underlying geochemical, climatic, and ecological dynamics must be characterized at different scales to be effectively modeled. Most aerobiological studies have focused on a high level: 'How high are airborne microbes found?' and 'How far can they travel?' Most fog and cloud water studies collect from stationary ground stations (point) or along flight transects (1D). To complement and provide context for this data, we have designed a UAV-based modified fog and cloud water collector to retrieve 4D-resolved samples for biological and chemical analysis.Our design uses a passive impacting collector hanging from a rigid rod suspended between two multi-rotor UAVs. The suspension design reduces the effect of turbulence and potential for contamination from the UAV downwash. The UAVs are currently modeled in a leader-follower configuration, taking advantage of recent advances in modular UAVs, UAV swarming, and flight planning.The collector itself is a hydrophobic mesh. Materials including Tyvek, PTFE, nylon, and polypropylene monofilament fabricated via laser cutting, CNC knife, or 3D printing were characterized for droplet collection efficiency using a benchtop atomizer and particle counter. Because the meshes can be easily and inexpensively fabricated, a set can be pre-sterilized and brought to the field for 'hot swapping' to decrease cross-contamination between flight sessions or use as negative controls.An onboard sensor and logging system records the time and location of each sample; when combined with flight tracking data, the samples can be resolved into a 4D volumetric map of the fog bank. Collected samples can be returned to the lab for a variety of analyses. Based on a review of existing flight studies, we have identified ion chromatography, metagenomic sequencing, cell staining and quantification, and ATP quantification as high-priority assays for implementation. Support for specific toxicology assays, such as methylmercury quantification, is also planned.

Design↗

A UAV-Based Fog Collector Design for Fine-Scale Aerobiological Sampling

Airborne microbes are found throughout the troposphere and into the stratosphere. Knowing how the activity of airborne microorganisms can alter water, carbon, and other geochemical cycles is vital to a full understanding of local and global ecosystems. Just as on the land or in the ocean, atmospheric regions vary in habitability; the underlying geochemical, climatic, and ecological dynamics must be characterized at different scales to be effectively modeled. Most aerobiological studies have focused on a high level: 'How high are airborne microbes found?' and 'How far can they travel?' Most fog and cloud water studies collect from stationary ground stations (point) or along flight transects (1D). To complement and provide context for this data, we have designed a UAV-based modified fog and cloud water collector to retrieve 4D-resolved samples for biological and chemical analysis.Our design uses a passive impacting collector hanging from a rigid rod suspended between two multi-rotor UAVs (Unmanned Aerial Vehicles). The suspension design reduces the effect of turbulence and potential for contamination from the UAV downwash. The UAVs are currently modeled in a leader-follower configuration, taking advantage of recent advances in modular UAVs, UAV swarming, and flight planning.The collector itself is a hydrophobic mesh. Materials including Tyvek, PTFE, nylon, and polypropylene monofilament fabricated via laser cutting, CNC knife, or 3D printing were characterized for droplet collection efficiency using a benchtop atomizer and particle counter. Because the meshes can be easily and inexpensively fabricated, a set can be pre-sterilized and brought to the field for 'hot swapping' to decrease cross-contamination between flight sessions or use as negative controls.An onboard sensor and logging system records the time and location of each sample; when combined with flight tracking data, the samples can be resolved into a 4D volumetric map of the fog bank. Collected samples can be returned to the lab for a variety of analyses. Based on a review of existing flight studies, we have identified ion chromatography, metagenomic sequencing, cell staining and quantification, and ATP quantification as high-priority assays for implementation. Support for specific toxicology assays, such as methyl-mercury quantification, is also planned.

Design↗