Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “gray-box model”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

Gray-Box Modeling for Distribution Systems With Inverter-Based Resources: Integrating Physics-Based and Data-Driven Approaches

Here, in this paper, we develop a novel gray-box modeling approach for distribution systems with inverter-based resources (IBRs). The proposed gray-box modeling method aims to improve estimation accuracy by taking advantages of both physics-based (white-box) and data-driven (black-box) modeling approaches. To this end, we utilize partial physical knowledge of the system, including the inverters’ structures and control diagrams, as well as the equivalent network model simplified through Kron reduction. The white-box model containing unknown parameters is then constructed with mathematical equations and an optimization-based method is subsequently employed to identify these unknown parameters within the white-box model. Next, the graybox modeling framework is then constructed by embedding the output variables of the white-box model into the input vector of a black-box model (represented using a neural network). Finally, the black-box section is trained using the collected input-output datasets and the gray-box model is then obtained. Furthermore, case studies demonstrate that our gray-box modeling approach effectively improves estimation accuracy compared to purely physics-based or data-driven methods.

42 ENGINEERING↗

Gray-Box Modeling for Distribution Systems with Inverter-Based Resources

In this paper, we develop a novel gray-box modeling approach for distribution systems with inverter-based resources (IBRs). The proposed gray-box modeling method aims to improve estimation accuracy by taking advantages of both physics-based (white-box) and data-driven (black-box) modeling approaches. To this end, the gray-box modeling framework is constructed by encoding prior physical knowledge of the system into a whitebox model and then embedding the output variables of the white-box model into the input vector of a black-box model. Especially, the white-box modeling component is constructed alongside the equivalent network model simplified with Kron reduction. Furthermore, case studies demonstrate that our graybox modeling approach effectively improves estimation accuracy compared to purely physics-based or data-driven methods.

Zhang, Junhui↗

Gray-Box Fault Models and Applications for Low-Carbon Emission CO 2 Refrigeration Systems

CO 2 refrigeration systems have attracted more attentions in recent years because of their zero-carbon emission advantages compared with traditional refrigerants. These systems are widely used in certain commercial buildings such as supermarkets. However, very limited energy studies have been done for such refrigeration systems under faults. This study investigated five common faults for supermarket transcritical CO 2 refrigeration systems with display cases. The following major tasks were implemented for this study. (1) Five fault models (gray-box format) regarding the power consumption and supply air temperature were proposed for low- and high-temperature display cases, respectively. The models cover: ice accumulation on evaporator coil, evaporator fan partial failure, expansion valve failure, display door open, and condenser blockage. (2) These fault models were calibrated with field tests, and the modeling accuracies were in good agreement with measurement datasets. (3) The proposed fault models demonstrated more than 90% of fault detection for Fault Detection and Diagnostics (FDD) purposes for both field measurement and simulated data.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Development, calibration, and validation of a novel gray-box energy model for residential split air conditioners

Energy models for vapor compression refrigeration in residential air conditioners have been developed through white-box, gray-box, and black-box methods in decades. However, existing white-box and gray-box models require complicated equations with detailed geometries while black-box models require substantial experimental data. Further, this paper aims to develop and validate a simple gray-box steady-state energy model without the need for detailed geometries, which can accurately predict the cooling capacity and electrical power input based on outdoor and indoor air conditions, and supply airflow rates. First three state variables, including the evaporation and condensation temperatures, and refrigerant mass flowrate, are applied to develop the energy model and are solved by three physical equations, including the energy conservations at the evaporator and condenser, and the refrigerant volume-mass flow correlation of the compressor. Secondly, seven performance property functions related to three state variables and three physical equations are identified and calibrated by simple temperature and power measurements. Finally, field experiments are conducted on a residential air conditioner to calibrate these performance property functions and validate the developed model. The validated results reveal the model can accurately predict the cooling capacity and electrical power input, with the normalized root mean square errors of 2.3% and 0.87% respectively.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Machine learning-enhanced hybrid modeling approach for better identification of a building thermal network model and improved prediction

The gray-box modeling approach, which uses a semi-physical thermal network model, has been widely used in building prediction applications, such as model predictive control (MPC). However, unmeasured disturbances, such as occupants, lighting, and in/exfiltration loads, make it challenging to apply this approach to practical buildings. In this word, we propose a hybrid modeling approach that integrates the gray-box model with a model for unmeasured disturbance. After reviewing several system identification approaches, we systematically designed the unmeasured disturbance model with a model selection process based on statistical tests to make it robust. We generated data based on the building model calibrated by real operational data and then trained the hybrid model for two different weather conditions. The hybrid model approach demonstrates an RMSE reduction of approximately 0.2–0.9 °C and 0.3–2 °C on 1-day ahead temperature prediction compared to the Conventional approach for mild (Berkeley, CA) and cold (Chicago, IL) climates, respectively. In addition, this approach was applied to experimental data obtained from the laboratory building to be used for the MPC application, showing superior prediction performances.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

A hierarchical gray-box dynamic modeling methodology for direct-expansion cooling systems to support control stability analysis; Méthodologie de modélisation dynamique hiérarchique de type boîte grise pour les systèmes de refroidissement à détente directe afin de soutenir l'analyse de stabilité de la commande

In this paper, a gray-box dynamic modeling approach for direct-expansion cooling systems is presented. The overall approach incorporates a multi-stage training procedure that consists of 1) identification of component sub-models from quasi-steady-state performance data, 2) system model integration with estimation of refrigerant charge and 3) fine tuning of thermal capacitances of the evaporator and condenser to capture the system dynamic responses. Compared to traditional physics-based models, the proposed modeling approach has advantages including reduced engineering efforts in the model development phase, improved computational efficiency and enhanced prediction accuracy. The modeling method was validated using a 3-ton variable-speed heat pump and proved to be capable of accurately predicting the system transient behaviors over a wide range of operating conditions. The established dynamic model was then applied for control stability analysis, with a specific goal of determining a proper control execution time step. The case study results showed that the stable control execution time step could change significantly, from 3 sec to 19 sec, as the operating conditions and control settings vary, and a proper selection of the execution time step is critical to ensure stable and reliable operations.

42 ENGINEERING↗

Grey-box Fault Models and Applications for Low Carbon Emission CO2 Refrigeration System

CO2 refrigeration systems have attracted more attentions in recent years because of their zero-carbon emission advantages compared with traditional refrigerants. These systems are widely used in certain commercial buildings such as supermarkets. However, very limited energy studies have been done for such refrigeration systems under faults. Furthermore, this study investigated five common faults for supermarket transcritical CO2 refrigeration systems with display cases. The following major tasks were implemented for this study. (1) Five fault models (gray-box format) regarding the power consumption and supply air temperature were proposed for low- and high-temperature display cases, respectively. The models cover: ice accumulation on evaporator coil, evaporator fan partial failure, expansion valve failure, display door open, and condenser blockage. (2) These fault models were calibrated with field tests, and the modeling accuracies were in good agreement with measurement datasets. (3) The proposed fault models demonstrated more than 90% of fault detection for Fault Detection and Diagnostics (FDD) purposes for both field measurement and simulated data.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

zPerf: A Statistical Gray-Box Approach to Performance Modeling and Extrapolation for Scientific Lossy Compression

With the scaling up of simulation-based scientific discovery on high-performance computing systems, the disparity between compute and I/O has increased, forcing domain scientists to save only a small amount of simulation data to persistent storage. This can result in the loss of essential physics fields that are needed for data analysis. While error-bounded lossy compression has made tremendous progress in bridging the gap between compute and I/O, the lack of understanding of compression performance remains a key hurdle to its wide adoption. Here, in this work, we present zPerf, a statistical gray-box performance modeling approach for scientific lossy compression. Our contributions are threefold: 1) We develop zPerf to estimate the performance of lossy compression techniques, based on in-depth understanding and statistical modeling for data features and core compression metrics; 2) We demonstrate the in-detailed implementation of zPerf using two case studies, where we derive the performance modeling for SZ and ZFP, two leading lossy compressors; 3) We evaluate the effectiveness of zPerf on real-world datasets across various domains. Based on the evaluation, we demonstrate the efficacy of the zPerf performance model; 4) We further discuss three case studies where zPerf is applied to extrapolate the compression ratio of SZ and ZFP with alternative encoding schemes as well as ZFP with an alternative transform scheme. Through the case studies, we demonstrate the potential of zPerf for exploring the design space of lossy compression, which has hardly been studied in the literature.

97 MATHEMATICS AND COMPUTING↗

Performance Evaluation of Gray-box and Machine Learning Models of a Thermal Energy Storage System with Active Insulation

An interior partition wall integrated with active thermal storage and a dynamic insulation system was built and then installed in an office building in Oak Ridge, Tennessee, TN. This smart wall, termed the Empower Wall, was equipped with embedded pipes in the building envelope core component and an additional pipe network enclosing rigid insulation to switch on and off the active insulation dynamically. The performance of the wall's contribution to cooling load reduction under different parameters has been investigated in previous publications. Aiming to be deployed into model predictive control and other optimization methods, simplified and reliable models for the developed wall and the room accommodating it are required. They are needed to characterize the properties and thermal response of both Empower Wall and building envelope, which form an essential component for accurate indoor temperature or cooling/heating demand prediction. In this study, simplified gray-box and regression models as well as machine learning model were developed and the performance of them were compared and analyzed.

Cui, Borui↗

A novel implicit hybrid machine learning model and its application for reinforcement learning

A novel methodology to develop implicit hybrid models is presented. PyTorch is used to integrate physics-based equations with machine learning models. Automatic differentiation of the hybrid model is leveraged to solve the implicit equations. Iterative solving enables gradient based updates to the machine learning model. The novel methodology is compared to an explicit hybrid approach on a continuously stirred tank reactor (CSTR). The novel method results in a lower modelling error. Both hybrid models effectively train with noisy data. To test the implicit hybrid model, it is employed as a reinforcement learning (RL) training model. The RL algorithm trained on the hybrid model outperforms real time optimization of the CSTR and performs nearly as well as RL trained directly on the CSTR and a traditional gradient based approach. Training RL directly on the CSTR requires over 60,000 system interactions compared to 6000 historical data points for hybrid model development.

42 ENGINEERING↗

Automated fault detection of residential air-conditioning systems using thermostat drive cycles

Residential air conditioning equipment comprises a significant portion of the total energy consumption of a home. Unfortunately, air-conditioning systems can be susceptible to faulty operation either from installation errors or faults that accrue over the equipment’s lifetime. This paper presents a novel automated fault detection algorithm for residential air-conditioning systems that can alert the homeowner of the presence of these faults. The proposed algorithm utilizes only the home’s thermostat and outside air temperature to perform automated fault detection over the course of the equipment’s lifetime, including immediately after installation. The algorithm uses an extended Kalman filter approach to identify a three-resistor, two-capacitor (3R2C) electrical equivalent thermodynamic model. The identified 3R2C model is used to predict cooling times during a testing period comprising of a series of thermostat drive-cycle experiments. We tested the algorithm on an EnergyPlus™ model of a typical residential building in Orlando, Florida. Duct faults, indoor airflow faults, and refrigerant undercharge faults were introduced into the building model one at a time. The algorithm was able to accurately determine duct-leak faults, 40% airflow faults, 40% undercharge faults, and no-fault cases with an accuracy of 70%, 77%, 82%, and 87%, respectively.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Sensitivity analysis of an automated fault detection algorithm for residential air-conditioning systems

The state of the art of fault detection and diagnosis (FDD) for residential air-conditioning systems is expensive and not yet amenable to widespread implementation. FDD for homes can significantly reduce utility costs, and increase the lifespan of the equipment. The cost barriers currently, however, make FDD for homes economically unviable for large scale implementation. In prior work, we offered a solution to reduce FDD costs by proposing an automated fault detection algorithm to serve as a screening step before more expensive FDD tests can be conducted. The algorithm uses only the home thermostat and local weather information to identify thermodynamic parameters and detect high-impact air-conditioning faults, including those that occur during equipment installation. We had tested the algorithm on a single EnergyPlus™ model of a home in Orlando, Florida. The thermodynamic parameter identification process is highly nonconvex involving several local optimal solutions. In this paper we propose a novel method to select the best model for fault detection from among the list of local optimal solutions to make the algorithm more robust to homes of different construction, without which the fault detection process would be infeasible. Another unique contribution of the paper is implementing the solution on real-world data. We also bring the algorithm closer to market by testing it on real-world data. We implement the algorithm on data obtained from experiments conducted by the Florida Solar Energy Center (FSEC) on a laboratory home equipped with a heat pump where faults were intentionally added for a period of seven months. The algorithm successfully detected an undercharge fault with 70.6% accuracy, concurrent duct leakage and undercharge faults with 85.2% accuracy, and duct leakage faults with 69.1% accuracy. A sensitivity analysis is also performed on EnergyPlus models of nine types of homes that vary in construction to demonstrate the robustness of the algorithm. Finally, the algorithm achieves an average accuracy of 71% for no-fault condition, 77% for 40% undercharge fault, and 76% for duct-leak fault.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Machine learning-enhanced MPC for demand flexibility in small commercial buildings: An experimental study

Small- and medium-sized commercial buildings (SMCBs) represent the majority of U.S. commercial building stock and a significant share of peak electricity demand, yet they often lack centralized building automation systems, representing a significant untapped resource for urban energy management. This infrastructure gap makes advanced control implementation challenging, limiting the potential for widespread demand flexibility. Model Predictive Control (MPC) has shown strong potential for load shifting, peak demand reduction, and cost savings, but its effectiveness is hindered by unmeasured disturbances such as internal heat gains. This paper presents a Hybrid MPC framework that integrates a physics-based gray-box building thermal model, identified using a lumped disturbance (LD) approach, with a machine learning (ML) model for forecasting unmeasured disturbances. The hybrid approach is designed for buildings with multiple individually controlled heat pump and thermostat pairs, common in SMCBs, and aims to optimize coordinated scheduling of multiple heat pumps under dynamic electricity pricing while respecting comfort constraints. The methodology is validated through both simulations of case study buildings and experimental studies at a highly-instrumented test facility. Simulation results show that the Hybrid MPC achieves substantial load shifting and peak demand reduction, approaching the performance of an ideal MPC with perfect disturbance knowledge, and outperforming a conventional MPC without disturbance forecasting. In experiments, the Hybrid MPC reduced daily HVAC energy costs by 8.7%, peak-price time load (load shifting) by 41.7%, and peak demand by 29.2% compared to baseline control, demonstrating comparable benefits to the 11.6% cost savings, 42.9% load shifting, and 23.2% peak reduction of the ideal MPC. These results demonstrate that the proposed hybrid modeling approach can significantly improve MPC performance in real-world SMCB applications without requiring additional disturbance measurements.

Demand Flexibility↗

Learning effective stochastic differential equations from microscopic simulations: Linking stochastic numerics to deep learning

We identify effective stochastic differential equations (SDEs) for coarse observables of fine-grained particle- or agent-based simulations; these SDEs then provide useful coarse surrogate models of the fine scale dynamics. We approximate the drift and diffusivity functions in these effective SDEs through neural networks, which can be thought of as effective stochastic ResNets. The loss function is inspired by, and embodies, the structure of established stochastic numerical integrators (here, Euler–Maruyama and Milstein); our approximations can thus benefit from backward error analysis of these underlying numerical schemes. They also lend themselves naturally to “physics-informed” gray-box identification when approximate coarse models, such as mean field equations, are available. Existing numerical integration schemes for Langevin-type equations and for stochastic partial differential equations can also be used for training; we demonstrate this on a stochastically forced oscillator and the stochastic wave equation. Our approach does not require long trajectories, works on scattered snapshot data, and is designed to naturally handle different time steps per snapshot. We consider both the case where the coarse collective observables are known in advance, as well as the case where they must be found in a data-driven manner.

97 MATHEMATICS AND COMPUTING↗

Canonical and noncanonical Hamiltonian operator inference

Here, a method for the nonintrusive and structure-preserving model reduction of canonical and noncanonical Hamiltonian systems is presented. Based on the idea of operator inference, this technique is provably convergent and reduces to a straightforward linear solve given snapshot data and gray-box knowledge of the system Hamiltonian. Examples involving several hyperbolic partial differential equations show that the proposed method yields reduced models which, in addition to being accurate and stable with respect to the addition of basis modes, preserve conserved quantities well outside the range of their training data.

97 MATHEMATICS AND COMPUTING↗

Performance analysis and comparison of data-driven models for predicting indoor temperature in multi-zone commercial buildings

Building thermal models, which characterize the properties of a building’s envelope and thermal mass, are essential for accurate indoor temperature and cooling/heating demand prediction. Because of their flexibility and ease of use, data-driven models are increasingly used. Here, this study compared and analyzed the performance of gray-box (resistance-capacitance) and black-box (recurrent neural network) models for predicting indoor air temperature in a real multi-zone commercial building. The developed resistance-capacitance model served as a benchmark model for which full sets of temporal data and building information were used as inputs. The recurrent neural network models were trained and tested assuming various available types and amounts of temporal data and known building physical information to investigate the effects of data and information availability. Feature importance analysis was conducted to select the key variables for different prediction targets under different scenarios. This research provides guidance in selecting an appropriate building thermal response modeling method based on the measured data availability, building physical information, and application.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗